17:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2 dBm/ +5.2 dBm
Tx4 +1.9 dBm
Line voltage and power: 4070 VAC, 310 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2 dBm
Tx4 +1.9 dBm
D3 -8.0 dBm
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.4 dBm
Tx4 +2.0 dBm
D3 -6.4 dBm
Line voltage and power: 4080 VAC, 315 KW