﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc	parents
1475	23 Apr 19:50 Transmitter Power Measurements	ryaya		"08:20 HV ON
08:29 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +1.8 dBm
Line voltage and power: 4050 VAC, 290 KW
09:00 Driver 4 plate failure 
09:15 interlock error at PA 2
09:20 HV OFF
11:45 HV ON
12:30 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +1.6 dBm/ +4.7 dBm
Tx4 +2.0 dBm
Line voltage and power: 4020 VAC, 300 KW 
14:20 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.0 dBm/ +5.2 dBm
Tx4 +2.2 dBm
Line voltage and power: 4020 VAC, 300 KW 
15:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +1.6 dBm/ +4.8 dBm
Tx4 +1.9 dBm
Line voltage and power: 4010 VAC, 300 KW 
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 300 KW
16:30 HV OFF
16:50 HV ON (DR 3 TX Imaging ON)
17:15 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
DR3 -8.2 dBm
Line voltage and power: 4040 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.1 dBm
Tx4 +2.2 dBm
DR3 -8.2 dBm
Line voltage and power: 4080 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3 dBm
Tx4 +2.3 dBm
DR3 -8.0 dBm
Line voltage and power: 4100 VAC, 300 KW"	Transmitters	new	normal	2014_04_ISR+Imaging	ISR					