Opened 11 years ago
#1475 new Transmitters
23 Apr 19:50 Transmitter Power Measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_04_ISR+Imaging |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description ΒΆ
08:20 HV ON
08:29 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +1.8 dBm
Line voltage and power: 4050 VAC, 290 KW
09:00 Driver 4 plate failure
09:15 interlock error at PA 2
09:20 HV OFF
11:45 HV ON
12:30 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +1.6 dBm/ +4.7 dBm
Tx4 +2.0 dBm
Line voltage and power: 4020 VAC, 300 KW
14:20 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.0 dBm/ +5.2 dBm
Tx4 +2.2 dBm
Line voltage and power: 4020 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +1.6 dBm/ +4.8 dBm
Tx4 +1.9 dBm
Line voltage and power: 4010 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 300 KW
16:30 HV OFF
16:50 HV ON (DR 3 TX Imaging ON)
17:15 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
DR3 -8.2 dBm
Line voltage and power: 4040 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.1 dBm
Tx4 +2.2 dBm
DR3 -8.2 dBm
Line voltage and power: 4080 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3 dBm
Tx4 +2.3 dBm
DR3 -8.0 dBm
Line voltage and power: 4100 VAC, 300 KW