Opened 11 years ago
Last modified 11 years ago
#1432 new Transmitters
02 Apr 19:50 Transmitter Power measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_03 ISCOD HLStormtime |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
09:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.7 dBm
Voltage line and power: 3900 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.0 dBm
2 +1.2 dBm/ +4.4 dBm
4 +1.4 dBm
Voltage line and power: 3850 VAC, 270 KW
11:00 TX Power sample (-70 dB coupling)
1 +5.1 dBm
2 +1.2 dBm/ +4.5 dBm
4 +1.4 dBm
Voltage line and power: 3860 VAC, 270 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +1.8 dBm/ +5.0 dBm
4 +2.0 dBm
Voltage line and power: 3950 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.6 dBm
Voltage line and power: 3850 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.6 dBm
Voltage line and power: 3850 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +1.5 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3890 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +1.5 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3890 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +1.6 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3900 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
1 +6.0 dBm
2 +1.8 dBm/ +5.0 dBm
4 +2.0 dBm
Voltage line and power: 3920 VAC, 300 KW
Subtickets (add)
Change History (1)
comment:1 Changed 11 years ago by imanay
- Summary changed from 2 Apr 19:50 Transmitter Power measurements to 02 Apr 19:50 Transmitter Power measurements