Opened 11 years ago
Last modified 11 years ago
#1154 new Transmitters
07 Ene 2014 19:55 Resumen TX
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2014_01 MST-ISR + EEJ |
Component: | ISR | Version: | |
Keywords: | Cc: | ||
Parent Tickets: |
Description
07:00 LV ON
07:15 HV ON
07:40
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea:4000 Vac, 280 Kw
08:05 RF OFF (sistema de adquisición)
09:28 Falla fuente SCREEN PA 1
09:33 Falla fuente SCREEN PA 1
10:20
Tx1: +3.9 dBm
Tx4: +3.6 dBm
11:50
Tx1: +4.0 dBm
Tx4: +3.7 dBm
Voltaje de linea:3900 Vac, 290 Kw
13:10 RF OFF, HV OFF (ruido en canales de Rx)
13:40 HV ON
13:50 Falla fuente SCREEN PA1
13:57 FAlla fuente SCREEN PA1
14:15
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea:3880 Vac, 290 Kw
14:40 Falla fuente SCREEN PA1
15:00
Tx1: +3.9 dBm
Tx4: +3.8 dBm
Voltaje de linea:3850 Vac, 290 Kw
16:00
Tx1: +3.9 dBm
Tx4: +3.8 dBm
Voltaje de linea:3850 Vac, 290 Kw
17:00
Tx1: +4.0 dBm
Tx4: +3.9 dBm
Voltaje de linea:3900 Vac, 300 Kw
18:00 Falla fuente SCREEN PA1
18:01
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea:3900 Vac, 290 Kw
18:20 Falla ventilador izquierdo, solo se usa ventilador derecho
19:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
19:20 Falla fuente SCREEN PA1
Subtickets (add)
Change History (2)
comment:1 Changed 11 years ago by ryaya
- Summary changed from 07 Ene 19:55 Resumen TX to 07 Ene 19:55 2014 Resumen TX
comment:2 Changed 11 years ago by ryaya
- Summary changed from 07 Ene 19:55 2014 Resumen TX to 07 Ene 2014 19:55 Resumen TX