Opened 11 years ago

Last modified 11 years ago

#1037 new Transmitters

26 Set 19:45 Lectura de Potencias

Reported by: vquesada Owned by:
Priority: normal Milestone: 2013_09_1 ISR+Imaging
Component: ISR+Imaging Version:
Keywords: Cc:
Parent Tickets:

Description

08:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.0 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
09:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.0 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
09:59 a 10:15 Falla interloock de Tx1 por que deja de funcinar ventilador de filamento
10:00
TX1 8 KW <> 1.3 dBm
TX2 10 KW <> 5.0 dBm
TX3 18 KW <> 5.0 dBm
Línea: 3900 VAC - 310 Kw
10:28 y 10:45 Cae fuente de screen PA Tx1
11:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.3 dBm
TX3 19 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
12:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.0 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
13:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.3 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw