Opened 11 years ago

Last modified 11 years ago

#1035 new Transmitters

25 Set 19:45 Lectura de potencias

Reported by: ryaya Owned by:
Priority: normal Milestone: 2013_09_1 ISR+Imaging
Component: ISR+Imaging Version:
Keywords: Cc:
Parent Tickets:

Description

08:00
TX1 8 KW
TX2 10 KW
TX3 15 KW
Línea: 3900 VAC - 300 KW

09:00 Ajuste de sintonía PA 3
TX1 8 KW
TX2 10 KW
TX3 19 KW
Línea: 3950 VAC - 310 KW

10:00
TX1 6 KW <> 1.2 dBm
TX2 9 KW <> 4.7 dBm
TX3 117 KW <> 5.2 dBm
Línea: 3880 VAC - 300 KW

11:00
TX1 8 KW
TX2 10 KW
TX3 18 KW
Línea: 3860 VAC - 300 KW

12:00
TX1 8 KW
TX2 11 KW
TX3 20 KW
Línea: 4000 VAC - 320 KW

13:30 Se activa ventilador principal 2
TX1 7 KW <> 1.2 dBm
TX2 9 KW <> 4.7 dBm
TX3 17 KW <> 5 dBm

14:00
TX1 8 KW
TX2 10 KW
TX3 18 KW
Línea: 3880 VAC - 310 KW

15:00
TX1 8 KW <> 1.2 dBm
TX2 9 KW <> 4.7 dBm
TX3 17 KW <> 5 dBm

16:00
TX1 8 KW
TX2 10 KW
TX3 18 KW
Línea: 3850 VAC - 310 KW

16:45 Se activa Driver 4 (Imagenes)

17:00
TX1 7 KW
TX2 6 KW
TX3 17 KW
D4 -8.2 dBm

18:00
TX1 7 KW <> 1.2 dBm
TX2 6 KW <> 1.1 dBm
TX3 18 KW <> 5 dBm
D4 -8.2 dBm
Línea: 3880 VAC - 310 KW

19:00
TX1 8 KW
TX2 7 KW
TX3 20 KW
D4 -7.8 dBm



Subtickets (add)

Change History (2)

comment:1 Changed 11 years ago by rabad

  • Milestone set to 2013_09 ISR+Imaging

comment:2 Changed 11 years ago by rabad

  • Component changed from ISR to ISR+Imaging
Note: See TracTickets for help on using tickets.