﻿__group__	ticket	summary	component	version	type	owner	status	created	_changetime	_description	_reporter
Milestone 2015_01 MST+ISR+EEJ	2076	03 Feb 17:00 Operation Resume	ISR	Others	General		new	2015-02-03T17:39:39-05:00	2015-02-03T17:39:39-05:00		avaldez
Milestone 2015_01 MST+ISR+EEJ	2073	09 Jan 20:00 Transmitter power measurements	ISR		Transmitters		new	2015-01-09T20:22:07-05:00	2015-01-09T20:22:07-05:00	"08:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 290 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 290 KW
'''09:31 Crowbar'''
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
'''10:38 Crowbar'''
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 295 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 295 KW
20:00 HV OFF
20:15 HV OFF"	vquesada
Milestone 2015_01 MST+ISR+EEJ	2072	09 Jan 20:00 Operation resume	ISR		General	AValdez	new	2015-01-09T19:56:11-05:00	2015-01-09T19:56:11-05:00	"Person in Charge: A. Valdez.
Experiment: MST-ISR-EEJ
1) 08:00 - 20:00
2) Operation Hours: 11:56 minutes
3) Operation incomplete:00:04 minutes
4) Reasons:
Problem at TX system 
-9:32
-10:37"	avaldez
Milestone 2015_01 MST+ISR+EEJ	2071	09 Jan 19:32 Spark gaps adjustement	ISR		Spark Gaps	AValdez	new	2015-01-09T19:51:57-05:00	2015-02-03T16:21:38-05:00	"09 Jan 07:49 Spark gaps adjustment.
09 Jan 11:40 Spark gaps adjustment.
09 Jan 14:00 Spark gaps adjustment.
09 Jan 16:00 Spark gaps adjustment.
09 Jan 19:00 Spark gaps adjustment.
"	avaldez
Milestone 2015_01 MST+ISR+EEJ	2070	09 Jan  10:37 Transmitter fall	ISR		Transmitters	AValdez	new	2015-01-09T19:48:52-05:00	2015-02-03T16:20:57-05:00	Transmitter Fall. At 10:39 transmitter works OK.	avaldez
Milestone 2015_01 MST+ISR+EEJ	2069	09 Jan 09:32 Transmitter fall	ISR		Transmitters	AValdez	new	2015-01-09T19:48:17-05:00	2015-02-03T16:24:27-05:00	Transmitter Fall. At 09:34  transmitter works OK.	avaldez
Milestone 2015_01 MST+ISR+EEJ	2068	09 Jan 08:00 Operation resume	ISR		General	P. Condor	new	2015-01-09T08:09:59-05:00	2015-01-09T08:09:59-05:00	"Person in Charge: P. Condor.
Experiment: MST-ISR-EEJ
1) 20:00 - 08:00
2) Operation Hours: 12
3) Operation incomplete:  
4) Reasons:"	pcondor
Milestone 2015_01 MST+ISR+EEJ	2067	09 Jan 07:00 Transmitter Power Measuremen	ISR		Transmitters		new	2015-01-09T07:58:51-05:00	2015-01-09T07:58:51-05:00	"
01/08/2015
20:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 295 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 295 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 295 KW
23:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4100 VAC, 295 KW

01/09/2015
00:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4100 VAC, 295 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4100 VAC, 295 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 295 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.7 dBm
 Line voltage and power: 4050 VAC, 290 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.7 dBm
 Line voltage and power: 4050 VAC, 290 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.7 dBm
 Line voltage and power: 4050 VAC, 290 KW



"	rtadeo
Milestone 2015_01 MST+ISR+EEJ	2066	09 Jan 04:46 Spark gaps adjustment	ISR		Spark Gaps	W. Rojas	new	2015-01-09T06:51:12-05:00	2015-01-09T08:11:47-05:00	"08 Jan 21:55 Spark gaps adjustment
09 Jan 01:34 Spark gaps adjustment
09 Jan 04:46 Spark gaps adjustment
09 Jan 07:49 Spark gaps adjustment"	pcondor
Milestone 2015_01 MST+ISR+EEJ	2065	08 Jan 23:59 Figures of rtis and spectras	ISR		Process/Analysis Program	P. Condor	new	2015-01-09T03:53:30-05:00	2015-01-09T03:53:30-05:00	Figures of rtis and spectras of MST ISR EEJ.	pcondor
Milestone 2015_01 MST+ISR+EEJ	2063	08 Jan 07:59 Operation resume	ISR		General	I. Manay	new	2015-01-08T08:01:23-05:00	2015-01-08T08:10:03-05:00	"Experiment: MST-ISR-EEJ
1) 20:00 - 08:00
2) Operation Hours: 10 h 25 minutes
3) Operation incomplete: 1 h 35 minutes
4) Reasons:
-Transmitters were off."	imanay
Milestone 2015_01 MST+ISR+EEJ	2062	07 Jan 23:05 Transmitter fall	ISR		Transmitters		new	2015-01-08T07:55:57-05:00	2015-02-03T16:11:44-05:00	"07/01/2015
23:05 High variation in the power line - failure of the TX4 source screen
"	rtadeo
Milestone 2015_01 MST+ISR+EEJ	2061	08 Jan 07:00 Transmitter power measurements	ISR		Transmitters		new	2015-01-08T07:53:34-05:00	2015-01-08T07:53:34-05:00	"
2015_01 MST+ISR+EEJ  
01/07/2015
20:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
23:05 High variation in the power line - failure of the TX4 source screen

01/08/2015
00:55 transmitter ON
00:55 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4100 VAC, 290 KW
01:00 source fails screen TX1
02:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4100 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4100 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4100 VAC, 290 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 290 KW







 
"	rtadeo
Milestone 2015_01 MST+ISR+EEJ	2060	08 Jan 06:07 Spark gaps adjustment	ISR		Spark Gaps	W. Rojas	new	2015-01-08T06:39:23-05:00	2015-01-08T06:39:23-05:00	"07 Jan 22:20 Spark gaps adjustment.
08 Jan 03:00 Spark gaps adjustment.
08 Jan 06:07 Spark gaps adjustment."	imanay
Milestone 2015_01 MST+ISR+EEJ	2059	08 Jan 01:00 Transmitters dropped	ISR		Transmitters	I. Manay	new	2015-01-08T02:41:27-05:00	2015-01-08T02:41:27-05:00		imanay
Milestone 2015_01 MST+ISR+EEJ	2058	08 Jan 00:50 Problem with transmitters	ISR		Transmitters	I. Manay	new	2015-01-08T02:34:42-05:00	2015-02-03T16:09:43-05:00	"Transmitters failed because line voltage dropped. Protection circuit of screen power supply also failed and a diode bridge at the screen source was damaged. This component was changed.
Transmitters were off 1:35 From 23:15 to 00:50."	imanay
Milestone 2015_01 MST+ISR+EEJ	2057	07 Jan 23:59 Experiment plots	ISR		Plot	I. Manay	new	2015-01-08T02:14:08-05:00	2015-01-08T02:14:08-05:00		imanay
Milestone 2015_01 MST+ISR+EEJ	2056	07 Jan 20:00 Operation resume	ISR		General		new	2015-01-07T20:00:53-05:00	2015-01-07T20:00:53-05:00	"Experiment: MST-ISR-EEJ
1) 08:00 - 20:00
2) Operation Hours: 11:55
3) Operation incomplete: 00:05
4) Reasons:
-Replacement of Hard drive, the computer had to be rebooted."	joscanoa
Milestone 2015_01 MST+ISR+EEJ	2055	07 Jan 19:06 Spark gaps adjustment	ISR		Spark Gaps		new	2015-01-07T19:55:09-05:00	2015-01-07T19:55:09-05:00	"07 Jan 11:09 Spark gaps adjustment
07 Jan 15:23 Spark gaps adjustment
07 Jan 19:06 Spark gaps adjustment"	joscanoa
Milestone 2015_01 MST+ISR+EEJ	2054	07 Jan 19:25 Transmitter power measurements	ISR		Transmitters		new	2015-01-07T19:43:32-05:00	2015-01-07T19:43:32-05:00	"09:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.8 dBm
Line voltage and power: 4060 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.7 dBm
Line voltage and power: 4050 VAC, 280 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4080 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4070 VAC, 280 KW
14:02 Problem detected at PA 1 screen power supply 
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.7 dBm
Tx4 +3.6 dBm
Line voltage and power: 4000 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.7 dBm
Tx4 +3.8 dBm
Line voltage and power: 4040 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4060 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +3.9 dBm
Line voltage and power: 4100 VAC, 290 KW"	ryaya
Milestone 2015_01 MST+ISR+EEJ	2053	07 Jan 17:00 Hard Drive replacement	ISR		Acquisition system		new	2015-01-07T17:53:35-05:00	2015-01-07T17:53:35-05:00	The hard drive was full and was replaced with an empty one	joscanoa
Milestone 2015_01 MST+ISR+EEJ	2052	07 Jan 14:15 Interference of Digisonde mode Day (5 am) corrected by filter	ISR		Reception		new	2015-01-07T17:51:43-05:00	2015-01-07T17:51:43-05:00	A filter was placed at the Digisonde to correct the inferference	joscanoa
Milestone 2015_01 MST+ISR+EEJ	2051	07 Jan 05:12 Interference of Digisonde mode Day (5 am)	ISR		Reception		new	2015-01-07T17:47:42-05:00	2015-01-07T17:47:42-05:00	Periodical interference with Digisonde mode Day, which started at 5 am.	joscanoa
Milestone 2015_01 MST+ISR+EEJ	2050	06 Jan 20:00  Operation resume	ISR		General	AValdez	new	2015-01-07T08:05:49-05:00	2015-01-07T08:05:49-05:00	"Person in Charge: Alexander Valdez
Experiment: MST-ISR-EEJ
1) 07:00 - 20:00
2) Operation Hours: 12:40
3) Operation incomplete: 00:20 
4) Reasons:
-A problem on the main PLC program caused an interrupt on the cooling system and turned off the transmitters. This problem could be caused by a malfunction on the PLC system or a transient voltage on the control system.
"	avaldez
Milestone 2015_01 MST+ISR+EEJ	2049	07 Jan 07:59 Operation resume	ISR		General	P. Condor	new	2015-01-07T07:58:38-05:00	2015-01-07T07:58:38-05:00	"Person in Charge: P. Condor
Experiment: MST-ISR-EEJ
1) 20:00 - 08:00
2) Operation Hours: 12
3) Operation incomplete: 0
4) Reasons:"	pcondor
Milestone 2015_01 MST+ISR+EEJ	2048	07 Jan 07:00 Spark gaps adjustment	ISR		Spark Gaps	A. Huamani	new	2015-01-07T07:56:02-05:00	2015-01-07T07:56:02-05:00	"06 Jan 23:00 Spark gaps adjustment
07 Jan 03:00 Spark gaps adjustment
07 Jan 07:00 Spark gaps adjustment"	pcondor
Milestone 2015_01 MST+ISR+EEJ	2047	07 Jan 07:00 Transmitter Power Measurements	ISR		Transmitters		new	2015-01-07T07:16:52-05:00	2015-01-07T07:16:52-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4000 VAC, 295 KW.
01:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4000 VAC, 295 KW.
02:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
03:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
04:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
05:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
06:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
07:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW."	vquesada
Milestone 2015_01 MST+ISR+EEJ	2046	06 Jan 23:59 Plots rtis and spectras	ISR		Process/Analysis Program	P. Condor	new	2015-01-07T01:20:08-05:00	2015-01-07T01:20:08-05:00	Plots rtis and spectras of Mst, ISR and EEJ.	pcondor
Milestone 2015_01 MST+ISR+EEJ	2045	06 Jan 23:00 Transmitter Power Measurements	ISR		Transmitters		new	2015-01-06T23:18:35-05:00	2015-01-06T23:18:35-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
21:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4090 VAC, 295 KW.
22:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4000 VAC, 295 KW.
23:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4000 VAC, 295 KW."	vquesada
Milestone 2015_01 MST+ISR+EEJ	2044	06 Jan 17:40 Digisonde  turned on	ISR		Antennas	AValdez	new	2015-01-06T19:39:55-05:00	2015-01-06T19:39:55-05:00		avaldez
Milestone 2015_01 MST+ISR+EEJ	2043	16 Jan 19:20 Transmitter power measurements	ISR		Transmitters		new	2015-01-06T19:38:10-05:00	2015-01-06T19:38:10-05:00	"06:40 LV ON
06:50 HV ON
07:06 CROWBAR Main plate voltage failure
08:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4070 VAC, 280 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4020 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 280 KW
11:57 Problem on PLC system causes an interruption on transmitter system, a system restarting was required
12:30 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 280 KW
12:40 CROWBAR main plate voltage failure
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4050 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4030 VAC, 280 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4080 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4100 VAC, 290 KW"	ryaya
Milestone 2015_01 MST+ISR+EEJ	2042	06 Jan 15:20 VIPIR turned on	ISR		Antennas	AValdez	new	2015-01-06T19:37:17-05:00	2015-01-06T19:37:17-05:00	"Vipir Turned on
1012.5km each 5min."	avaldez
Milestone 2015_01 MST+ISR+EEJ	2041	06 Jan 19:15   Spark gaps adjustment	ISR		Spark Gaps	AValdez	new	2015-01-06T19:34:25-05:00	2015-01-06T19:34:25-05:00	"06 Dec 07:10 Spark gaps adjustment.
06 Dec 11:16 Spark gaps adjustment.
06 Dec 15:25 Spark gaps adjustment.
06 Dec 19:13 Spark gaps adjustment."	avaldez
Milestone 2015_01 MST+ISR+EEJ	2040	06 Jan 11:57 Problem on transmitter system	ISR		Transmitters		new	2015-01-06T13:06:19-05:00	2015-01-06T13:06:19-05:00	A problem on the main PLC program caused an interrupt on the cooling system and  turned off the transmitters. This problem could be caused by a malfunction on the PLC system or a transient voltage on the control system.	ryaya
Milestone 2015_01 MST+ISR+EEJ	2039	06 Jan 07:05  Start of the experiment	ISR		Start experiment	AValdez	new	2015-01-06T07:33:50-05:00	2015-01-06T07:33:50-05:00	"Attenuations used at the reception lines.
MST-ISR-EEJ
CHA : 0dB
CHB : 0dB
CHC : 0dB
CHD : 0dB"	avaldez
Milestone 2015_01 MST+ISR+EEJ	2038	05 Jan 12:22 Antena VSWR	ISR		Antennas	ryanque	new	2015-01-05T12:40:40-05:00	2015-01-05T12:40:40-05:00	"Antenna:
S Up 1.04
S Dn 1.06
E Dn 1.05
E Up 1.05
N Up 1.05
N Dn 1.08
W Dn 1.02
W Up 1.06"	ryanque
Milestone 2015_01 MST+ISR+EEJ	2037	05 Jan 12:20 Log created	ISR		Start experiment	ryanque	new	2015-01-05T12:38:30-05:00	2015-01-05T12:38:30-05:00	"The log for the campaign MST-ISR-EEJ has been created

L. User: P. Condor, I. Manay

"	ryanque
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2075	03 Feb 17 :00 Operation resume	ISR	JRO Staff	General	avaldez	new	2015-02-03T17:34:45-05:00	2015-02-03T17:34:45-05:00		avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2036	22 Dec  07:59 Operation resume	ISR		General	AValdez	new	2014-12-22T07:25:47-05:00	2014-12-22T07:25:47-05:00	"
Person in Charge: Alexander Valdez
Experiment: EW_Drifts-Faraday-Imaging
1) 20:00 - 08:00
2) Operation Hours: 11 h 49 minutes.
3) Operation incomplete: 11 minutes.
4) Reasons:
-Desynchronization of Faraday. (10 minutes)
-Transmitter fall ( 1 minutes)


"	avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2035	22 Dec 07:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-12-22T07:18:22-05:00	2014-12-22T07:18:22-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
D3 -5.7 dBm
Line voltage and power: 4050 VAC, 295 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
D3 -5.7 dBm
Line voltage and power: 4050 VAC, 295 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.3 dBm
D3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.3 dBm
D3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.3 dBm
Tx4 +2.4 dBm
D3 -5.7 dBm
Line voltage and power: 4100 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.3 dBm
Tx4 +2.4 dBm
D3 -5.7 dBm
Line voltage and power: 4100 VAC, 300 KW"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2034	22 Dec 07:06 Spark gaps adjustment	ISR		Spark Gaps	A.Huamani	new	2014-12-22T07:16:44-05:00	2014-12-22T07:16:44-05:00	"21 Dec 22:00 Spark gaps adjustment.
22 Dec 01:19 Spark gaps adjustment.
22 Dec 04:00 Spark gaps adjustment.
22 Dec 07:00 Spark gaps adjustment."	avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2033	22 Dec 06:18 Transmitter fall	ISR		Transmitters	AValdez	new	2014-12-22T06:32:43-05:00	2014-12-22T06:32:43-05:00	Transmitter Fall. At 06:18transmitter works OK.	avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2032	22 Dec 05:22 Desynchronization of Faraday	ISR		Acquisition system	AValdez	new	2014-12-22T06:14:03-05:00	2014-12-22T06:14:03-05:00		avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2031	21 Dec 23:59 Plot of experiments	ISR		Plot	AValdez	new	2014-12-22T04:13:59-05:00	2014-12-22T04:13:59-05:00		avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2030	21 Dec 23:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-12-21T23:10:57-05:00	2014-12-21T23:10:57-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm
Tx4 +2.4 dBm
D3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm
Tx4 +2.4 dBm
D3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2029	21 Dec 19:59 Operation resume	ISR+Imaging		General	I. Manay	new	2014-12-21T19:43:01-05:00	2014-12-21T19:43:01-05:00	"Person in Charge: I. Manay
Experiment: EW_Drifts-Faraday-Imaging
1) 08:00 - 20:00
2) Operation Hours: 11 h 39 minutes.
3) Operation incomplete: 21 minutes.
4) Reasons:
-Electrical problems affected transmitters. (15 minutes)
-Computer halted. (3 minutes)
-Transmitters dropped. (3 minutes)"	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2028	21 Dec 19:23 Spark gaps adjustment	ISR+Imaging		Spark Gaps	A. Belleza	new	2014-12-21T19:35:58-05:00	2014-12-21T19:35:58-05:00	"21 Dec 10:15 Spark gaps adjustment.
21 Dec 13:19 Spark gaps adjustment.
21 Dec 16:25 Spark gaps adjustment.
21 Dec 19:23 Spark gaps adjustment."	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2027	21 Dec 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-12-21T19:34:54-05:00	2014-12-21T19:37:05-05:00	"09:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4070 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.2 dBm
Voltage line and power: 4080 VAC, 300 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.1 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4100 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.9 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4080 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4090 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4090 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.9 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4020 VAC, 290 KW
16:08 Problem at main voltage source causes the systemo goes off for some minutes.
17:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4030 VAC, 300 KW
17:40 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm
4 +2.3 dBm
D3 -5.6 dBm
Voltage line and power: 4020 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm
4 +2.4 dBm
D3 -5.6 dBm
Voltage line and power: 4030 VAC, 290 KW"	ryaya
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2026	21 Dec 18:45 Transmitters went up	ISR+Imaging		Transmitters	I. Manay	new	2014-12-21T19:29:02-05:00	2014-12-21T19:29:02-05:00	They went up after a drop of 3 minutes.	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2025	21 Dec 17:52 Imaging experiment is started	ISR+Imaging		Acquisition system	I. Manay	new	2014-12-21T19:22:34-05:00	2014-12-21T19:22:34-05:00		imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2024	21 Dec 08:11 faraday experiment was restarted	ISR+Imaging		Acquisition system	I. Manay	new	2014-12-21T19:12:42-05:00	2014-12-21T19:12:42-05:00	"The pc of the Faraday experiment(Radar) was restarted, because it halted. The acquisition program was also restarted.
Data was not saved from 8:08 to 8:11."	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2023	21 Dec 16:08 Problem at TX system	ISR+Imaging		Transmitters		new	2014-12-21T16:44:59-05:00	2014-12-21T19:22:13-05:00	"A problem on the main voltage power source (4160 VAC) causes a malfunction on the control system. The main control fuse blows up and all the system goes off. A system restart was required.
Transmitters were down from 16:05 to 16:20."	ryaya
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2022	21 Dec 07:30 Transmitter power measurements	ISR+Imaging		Transmitters		new	2014-12-21T07:46:31-05:00	2014-12-21T07:46:31-05:00	"12/20/2014
20:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm
 Tx4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 290 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm
 Tx4 +2.5 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 290 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm
 Tx4 +2.5 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm
 Tx4 +2.5 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 290 KW
12/21/2014
00:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm
 Tx4 +2.5 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 290 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm
 Tx4 +2.5 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4080 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm
 Tx4 +2.2 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4080 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm
 Tx4 +2.2 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4080 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm
 Tx4 +2.2 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4080 VAC, 290 KW
04:30 Imaging OFF
05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm / +5.5 dBm
 Tx4 +2.4 dBm
 Dr3 OFF
 Voltage line and power: 4080 VAC, 290 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.2 dBm / +5.6 dBm
 Tx4 +2.6 dBm
 Dr3 OFF
 Voltage line and power: 4100 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.2 dBm / +5.6 dBm
 Tx4 +2.6 dBm
 Dr3 OFF
 Voltage line and power: 4100 VAC, 300 KW






"	rtadeo
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2021	21 Dec 07:59 Operation resume	ISR		General	P. Condor	new	2014-12-21T07:17:53-05:00	2014-12-21T07:17:53-05:00	"Person in Charge: P. Condor
Experiment: EW_Drifts-Faraday-Imaging
1) 20:00 - 08:00
2) Operation Hours: 12
3) Operation incomplete: 0
4) Reasons:
"	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2020	21 Dec 03:47 Spark Gaps Adjusment	ISR		Spark Gaps	W. Rojas	new	2014-12-21T07:13:32-05:00	2014-12-21T08:12:47-05:00	"21:41 Spark Gaps Adjusment
00:23 Spark Gaps Adjusment
03:47 Spark Gaps Adjusment
07:13 Spark Gaps Adjusment"	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2019	21 Dec 04:30 Turn off Imaging	ISR		Acquisition system	P. Condor	new	2014-12-21T07:07:53-05:00	2014-12-21T07:07:53-05:00	Turn off Imaging	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2018	20 Dec 23:59 Plots of rtis, etc	ISR		Process/Analysis Program	P. Condor	new	2014-12-21T04:16:12-05:00	2014-12-21T04:16:12-05:00	Plots of rtis, etc.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2017	21 Dec 00:05 Attenuation of 1 dB for Ch D EW_Drifts	ISR		Reception	P. Condor	new	2014-12-21T04:04:45-05:00	2014-12-21T04:04:45-05:00	Attenuation of 1 dB for Ch D EW_Drifts to match with Ch C noise.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2016	20 Dec 22:40 Change of TR of Ch C EWDrifts	ISR		Reception	P. Condor	new	2014-12-21T04:00:11-05:00	2014-12-21T04:00:11-05:00	Change of TR of Ch C EWDrifts.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2015	20 Dec 19:55 tiempo de operacion	ISR		General		new	2014-12-20T20:05:21-05:00	2014-12-20T20:05:21-05:00	"Jefe de turno: A. Aguilar
Exp: EW_drifts_Farday_Imaging
1) 08:00 - 20:00\
2) Tiempo de operacion: 12 h
3) Tiempo de pare: 00 h
4) Motivo:"	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2014	20 Dec 18:40 spark gaps adjustments	ISR		Spark Gaps		new	2014-12-20T19:45:22-05:00	2014-12-20T19:45:22-05:00	Adjustment of spark gaps of all channels (TRs only)	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2013	20 Dec 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-12-20T19:44:46-05:00	2014-12-20T19:44:46-05:00	"09:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.3 dBm
Voltage line and power: 4040 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.3 dBm
Voltage line and power: 4020 VAC, 290 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.2 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4100 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4090 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.1 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4040 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.5 dBm
4 +2.4 dBm
16:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4040 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 290 KW
17:30 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm
4 +2.4 dBm
D3 -5.7 dBm
Voltage line and power: 4050 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.1 dBm
4 +2.5 dBm
D3 -5.6 dBm
Voltage line and power: 4090 VAC, 300 KW"	ryaya
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2012	20 Dec 17:35 activate Imaging experiment	ISR+Imaging		Start experiment		new	2014-12-20T18:35:32-05:00	2014-12-20T18:38:56-05:00	Imaging experiment was started	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2011	20 Dec 17:07 change of TR of channel C	ISR		Spark Gaps		new	2014-12-20T18:34:03-05:00	2014-12-20T18:34:03-05:00	change of TR of channel C (EW-Drifts experiment)	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2010	20 Dec 16:20 change of TR of channel D	ISR		Spark Gaps		new	2014-12-20T18:32:31-05:00	2014-12-20T18:32:31-05:00	change of TR of channel D (EW-Drifts experiment)	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2009	20 Dec 15:58 spark gaps adjustments	ISR		Spark Gaps		new	2014-12-20T18:29:41-05:00	2014-12-20T18:29:41-05:00	Adjustment of spark gaps of channels C and D (EW-Drifts experiment)	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2008	20 Dec 10:58 calibration of ATRs and TRs	ISR		Spark Gaps		new	2014-12-20T18:27:44-05:00	2014-12-20T18:27:44-05:00	calibration of all channels of EW-Drifts experiment.	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2007	20 Dec 14:37 calibration of ATRs and TRs	ISR		Spark Gaps		new	2014-12-20T18:24:44-05:00	2014-12-20T18:24:44-05:00	calibration of all channels of EW-Drifts experiment.	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2006	20 Dec 13:35 spark gaps adjustments	ISR		Spark Gaps		new	2014-12-20T18:22:19-05:00	2014-12-20T18:38:20-05:00	adjustment of spark gap of channel A (EW-Drifts experiment).	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2005	20 Dec 07:50 Transmitter power measurements	ISR+Imaging		Transmitters		new	2014-12-20T07:59:53-05:00	2014-12-20T07:59:53-05:00	"
20:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm
 Tx4 +2.4 dBm
 Dr3 -5.6 dBm
 Voltage line and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +1.8 dBm
 Tx4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 300 KW 
22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +1.8 dBm
 Tx4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 300 KW 
23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +1.9 dBm
 Tx4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4060 VAC, 300 KW 
00:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +1.9 dBm
 Tx4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4050 VAC, 300 KW 

01:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.5 dBm 
 Tx4 +2.4 dBm
 Dr3 OFF
 Voltage line and power: 4020 VAC, 290 KW 
02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.5 dBm 
 Tx4 +2.4 dBm
 Dr3 OFF
 Voltage line and power: 4020 VAC, 290 KW 
03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.5 dBm 
 Tx4 +2.4 dBm
 Dr3 OFF
 Voltage line and power: 4020 VAC, 290 KW 
04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.5 dBm 
 Tx4 +2.4 dBm
 Dr3 OFF
 Voltage line and power: 4050 VAC, 300 KW 
05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.3 dBm 
 Tx4 +2.2 dBm
 Dr3 OFF
 Voltage line and power: 4050 VAC, 300 KW 
06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.3 dBm 
 Tx4 +2.2 dBm
 Dr3 OFF
 Voltage line and power: 4050 VAC, 300 KW 
07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm / +5.3 dBm 
 Tx4 +2.2 dBm
 Dr3 OFF
 Voltage line and power: 4050 VAC, 300 KW 





"	rtadeo
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2004	20 Dec 07:59 Operation Resume	ISR+Imaging		General	I. Manay	new	2014-12-20T07:35:25-05:00	2014-12-20T07:35:25-05:00	"Person in charge : Ivan Manay
Experiment EW_Drift-Faraday-Imaging
1) 8:00PM - 8:00AM
2) Operation hours : 12 h
3) Operation incomplete: 0h
4) Reasons:
-None"	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2003	20 Dec 07:26 spark gaps adjustments	ISR+Imaging		Spark Gaps	W. Rojas	new	2014-12-20T07:30:19-05:00	2014-12-20T07:47:08-05:00	"19 Dec 22:31 Spark-gaps adjustment.
20 Dec 01:24 Spark-gaps adjustment.
20 Dec 04:30 Spark-gaps adjustment.
20 Dec 07:26 Spark-gaps adjustment."	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2002	20 Dec 01:02 ew_drift acquisition system is restarted	ISR+Imaging		Acquisition system	I. Manay	new	2014-12-20T02:19:41-05:00	2014-12-20T02:19:41-05:00	Acquisition program was manually restarted after it sent the audible alarm. This alarm was produced after the ew_drfit rf signal was connected to the transmitter.	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2001	20 Dec 01:00 Imaging experiment is stopped	ISR+Imaging		Acquisition system	I. Manay	new	2014-12-20T01:27:24-05:00	2014-12-20T01:27:24-05:00		imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	2000	19 Dec 23:59 Plot of experiments	ISR+Imaging		Plot	I. Manay	new	2014-12-20T00:23:05-05:00	2014-12-20T00:23:05-05:00		imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1999	19 Dec 18:42 TR down	ISR+Imaging		Transmitters		new	2014-12-19T21:02:02-05:00	2014-12-19T21:02:02-05:00		joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1998	19 Dec 20:00 Tiempo de operacion	ISR+Imaging		General		new	2014-12-19T21:01:57-05:00	2014-12-19T21:01:57-05:00	"

Jefe de turno:  J. Oscanoa
Exp: EW_drifts_Farday_Imaging
1) 08 am - pam
2) Tiempo de operacion: 11:50
3) Tiempo de pare: 10 min
4) Motivo:

    Caida de transmisor
    Desincronizacion Faraday 

"	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1997	19 Dec 18:10 Change of Cables of Channels A and C - EW Drifts	ISR+Imaging		Reception		new	2014-12-19T19:53:20-05:00	2014-12-19T19:53:20-05:00	Change of Cables of Channels A and C to reduce noise level	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1996	19 Dec 17:38 Restart Faraday	ISR+Imaging		Acquisition system		new	2014-12-19T19:50:03-05:00	2014-12-19T19:50:03-05:00	PC and batch were restarted	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1995	19 Dec 17:35 Faraday PC reboot	ISR+Imaging		Acquisition system		new	2014-12-19T19:47:56-05:00	2014-12-19T19:47:56-05:00	 Faraday PC reboot	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1994	19 Dec 17:33 Desynchronization of Faraday	ISR		Acquisition system		new	2014-12-19T19:46:01-05:00	2014-12-19T19:46:01-05:00	Desynchronization of Faraday	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1993	19 Dec 17:30 Imaging experiment started	ISR+Imaging		Start experiment		new	2014-12-19T19:40:15-05:00	2014-12-19T19:40:15-05:00	Imaging experiment started 	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1992	19 Dec 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-12-19T19:39:50-05:00	2014-12-19T19:39:50-05:00	"09:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.3 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 300 KW
09:58 Alarm at PA1 screen power supply
10:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +2.3 dBm/ +5.7 dBm
4 +2.6 dBm
Voltage line and power: 4040 VAC, 300 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +2.0 dBm/ +5.6 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.9 dBm/ +5.5 dBm
4 +2.4 dBm
Voltage line and power: 4080 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.8 dBm/ +5.3 dBm
4 +2.2 dBm
Voltage line and power: 4000 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.8 dBm/ +5.3 dBm
4 +2.2 dBm
Voltage line and power: 4000 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.8 dBm/ +5.4 dBm
4 +2.2 dBm
16:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.9 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4040 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.8 dBm/ +5.3 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 290 KW
17:30 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.9 dBm
4 +2.4 dBm
D3 -5.8 dBm
Voltage line and power: 4040 VAC, 290 KW
18:42 Crowbar protection activated.
19:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm
4 +2.4 dBm
D3 -5.6 dBm
Voltage line and power: 4090 VAC, 290 KW"	ryaya
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1991	19 Dec 16:00 Spark gaps adjustment	ISR		Spark Gaps		new	2014-12-19T19:36:26-05:00	2014-12-19T19:36:26-05:00	"11:00 Spark gaps adjustment
16:00 Spark gaps adjustment"	joscanoa
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1990	19 Dec 07:59 Operation Resume	ISR		General	P. Condor	new	2014-12-19T08:11:56-05:00	2014-12-21T05:24:58-05:00	"Person in charge: P. Condor
Experiment: EW_drifts-Faraday-Imaging
1) 08 pm - 8am
2) Operation Hours: 11:38
3) operation incomplete:    22 min
4) Reasons:
  - Transmitter Failure (7 min)
  - Pc Faraday shutdown and lost of sincronism (15 min)"	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1989	19 Dec 07:30 Calibration of TRs and ATRs	ISR		Antennas	A. Coronado	new	2014-12-19T07:50:12-05:00	2014-12-19T07:50:12-05:00	Calibration of TRs and ATRs	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1988	19 Dec 05:40 Change of TR of Ch A -EW_Drifts	ISR		Reception	P. Condor	new	2014-12-19T07:49:16-05:00	2014-12-19T07:49:16-05:00	 Change of TR of Ch A -EW_Drifts.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1987	19 Dec 04:08 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-12-19T07:48:01-05:00	2014-12-19T07:48:01-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1986	19 Dec 03:48 Restart Faraday	ISR		Acquisition system	P. Condor	new	2014-12-19T07:43:55-05:00	2014-12-19T07:43:55-05:00	Restart Faraday because is desynchronizated.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1985	19 Dec 03:40 Pc of Faraday standby	ISR		Acquisition system	P. Condor	new	2014-12-19T07:42:25-05:00	2014-12-19T07:42:25-05:00	Pc of Faraday stanby. Restart pc and batch	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1984	19 Dec 03:10 Transmitter Fall	ISR		Transmitters	P. Condor	new	2014-12-19T07:40:32-05:00	2014-12-19T07:40:32-05:00	Transmitter Fall. At 03:17 transmitter works OK.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1983	19 Dec 02:00 Imaging off	ISR		Acquisition system	P. Condor	new	2014-12-19T07:28:59-05:00	2014-12-19T07:28:59-05:00	 Imaging off	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1982	19 Dec. 07:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-12-19T07:09:56-05:00	2014-12-19T07:09:56-05:00	"'''19 December 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.7 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.7 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW

02:00 Driver 3 OFF

02:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1,5.4 dBm
Tx4 +2.7 dBm
D3 -5.5 dBm
Line voltage and power: 4080 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1,5.4 dBm
Tx4 +2.7 dBm
D3 -5.5 dBm
Line voltage and power: 4080 VAC, 300 KW

03:10 a 03:17 crowbar por caida de tension

04:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.7 dBm
Tx4 +2.5 dBm
Line voltage and power: 4080 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.7 dBm
Tx4 +2.5 dBm
Line voltage and power: 4080 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.5,5.8 dBm
Tx4 +2.7 dBm
Line voltage and power: 4100 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.5,5.8 dBm
Tx4 +2.7 dBm
Line voltage and power: 4100 VAC, 310 KW.

"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1981	19 Dec 00:36 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-12-19T01:05:13-05:00	2014-12-19T01:05:13-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1980	18 Dec 23:59 Plots of rtis,etc	ISR		Process/Analysis Program	P. Condor	new	2014-12-19T01:00:03-05:00	2014-12-19T01:00:03-05:00	Plots of rtis,etc	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1979	18 Dec 23:36 Desynchronization  of Faraday	ISR		Acquisition system	P. Condor	new	2014-12-19T00:59:10-05:00	2014-12-19T00:59:10-05:00	 Desynchronization  of Faraday	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1978	18 Dec 23:00 Ch D Imaging has normal level of noise	ISR		Reception	P. Condor	new	2014-12-19T00:34:45-05:00	2014-12-19T00:34:45-05:00	Ch D Imaging has normal level of noise. After of That was changing between 15 and 20 dB.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1977	18 Dec 21:00 Calibration of ATRs and TRs	ISR		Antennas	P. Condor	new	2014-12-19T00:31:43-05:00	2014-12-19T00:31:43-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1976	18 Dec 20:50 Ch D Imaging has low noise	ISR		Reception	P. Condor	new	2014-12-19T00:24:41-05:00	2014-12-19T00:24:41-05:00	Ch D Imaging has low noise. about 15 dB. After of any minutes rise little, is changing between 15 to 20 dB.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1975	18 Dic 23:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-12-18T23:09:18-05:00	2014-12-18T23:09:18-05:00	"'''18 December 2014'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.6 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.6 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3 dBm
Tx4 +2.7 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3 dBm
Tx4 +2.7 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1974	18 DEC 19:59  Tiempo de Operacion	ISR		Start experiment		new	2014-12-18T20:12:02-05:00	2014-12-18T20:12:02-05:00	"Jefe de Turno: Diego Lume
Experimento: EW_DRIFT-FARADAY-IMAGING
1) 08:00AM - 08:00PM
2) Tiempo de Operacion Normal: 11 horas 45min
3) Tiempo de Para: 15min
4) Motivo: caida transmisor"	dlume
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1973	18 Dic 19:47 Transmitter Power Measurements	ISR+Imaging		Transmitters		new	2014-12-18T19:56:18-05:00	2014-12-18T19:56:18-05:00	"
18 December 2014
 0800 TX Power sample (-70 dB coupling)
 Tx1 +5.0dBm
 Tx2 +2.0 ,+5.5 dBm
 Tx4 +2.6 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 0900 TX Power sample (-70 dB coupling)
 Tx1 +5.0dBm
 Tx2 +2.0 ,+5.5 dBm
 Tx4 +2.6 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 10:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3dBm
 Tx2 +2.4 ,+5.6 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 11:00 TX Power sample (-70 dB coupling)
 Tx1 +5.0 dBm
 Tx2 +2.0 ,+5.6 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 12:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3dBm
 Tx2 +2.2 ,+5.5 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 13:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2dBm
 Tx2 +2.3 ,+5.7 dBm
 Tx4 +2.6 dBm
 D3  off
 Line voltage and power: 4000 VAC, 290 KW
 14:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2dBm
 Tx2 +2.3 ,+5.7 dBm
 Tx4 +2.6 dBm
 D3  off
 Line voltage and power: 4000 VAC, 290 KW
 14:10 Fails because there is a variation of the line 4160 VAC
 15:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4dBm
 Tx2 +2.1 ,+5.3 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 16:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4dBm
 Tx2 +2.1 ,+5.3 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 17:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4dBm
 Tx2 +2.1 ,+5.3 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 17:30 begins images (-5.9 dBm)
 17:35 Fails because there is a variation of the line 4160 VAC
 17:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4dBm
 Tx2 +2.1 ,+5.3 dBm
 Tx4 +2.8 dBm
 D3  off
 Line voltage and power: 4050 VAC, 300 KW
 18:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4dBm
 Tx2 +2.0 dBm
 Tx4 +1 dBm
 19:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4dBm
 Tx2 +2.0 dBm
 Tx4 +2.8 dBm
 Dr3 -6.0 dBm
 19:25 Failure is detected in Screen Dr4 









"	rtadeo
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1972	18 DEC 19:25 screen driver 4 fails	ISR		Start experiment		new	2014-12-18T19:37:10-05:00	2014-12-18T19:37:10-05:00		dlume
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1971	18 DEC 19:05 Clamping diode review Faraday	ISR	JRO Staff	Start experiment		new	2014-12-18T19:30:57-05:00	2014-12-18T19:30:57-05:00		dlume
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1950	18 DEC 07:59  Tiempo de Operacion	ISR	JRO Staff	Transmitters	AVALDEZ	new	2014-12-18T07:54:20-05:00	2014-12-19T12:35:48-05:00	"Jefe de Turno:Alexander Valdez
Experimento:EWDrift-Faraday-Imaging
1) 08:00pm a 08:00 am
2) Tiempo de operacion:11horas 39 minutos
3) Tiempo de para:             21 minutos
4) Motivo:
    Variación abrupta del nivel de Tension ocasiona la caida del sistema de monitoreo lo que ocasiona la caida del sistema."	avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1949	18 DEC 07:30 TX On	ISR		Transmitters	AVALDEZ	new	2014-12-18T07:53:57-05:00	2014-12-19T10:57:31-05:00	EXPERIMENT RESTART	avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1948	18 Dec 07:09 Transmitter falls	ISR		Transmitters	AVALDEZ	new	2014-12-18T07:49:38-05:00	2014-12-19T10:59:10-05:00		avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1947	18 Dic 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-12-18T07:13:40-05:00	2014-12-18T07:13:40-05:00	"'''15 December 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.5 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.5 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 300 KW
02:00 Driver 3 OFF
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.1, 5.4 dBm
Tx4 +2.5 dBm
Line voltage and power: 4080 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.1, 5.4 dBm
Tx4 +2.5 dBm
Line voltage and power: 4080 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.0, 5.3 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.0, 5.3 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.0, 5.3 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.0, 5.3 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1946	17 Dec 23:59   FIGURES OF EXPERIMENT	ISR+Imaging	Others	Plot	AVALDEZ	new	2014-12-18T00:48:39-05:00	2014-12-19T10:58:29-05:00		avaldez
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1945	17 Dic 23:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-12-17T23:13:21-05:00	2014-12-17T23:13:21-05:00	"
== 15 December 2014 ==
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.1 dBm
Tx4 +2.4 dBm
D3  -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.1 dBm
Tx4 +2.4 dBm
D3  -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.6 dBm
D3  -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2 dBm
Tx4 +2.6 dBm
D3  -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1944	17 Dec 20:34 TIEMPO DE OPERACION	ISR		General		new	2014-12-17T20:44:47-05:00	2014-12-17T20:44:47-05:00	"Jefe de Turno: Jose Mayaute
Experimento: EW_DRIFT-FARADAY-IMAGING
1) 08:00AM - 08:00PM
2) Tiempo de Operacion Normal: 12 horas
3) Tiempo de Para: 0 h
4) Motivo: N/A"	jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1943	17 Dec 17:57 Calibration of ATR and TR	ISR		Antennas		new	2014-12-17T20:40:59-05:00	2014-12-17T20:40:59-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1942	17 Dec 2014 17:10 Problems with uploading images to the serverJRO-APP	ISR		Plot		new	2014-12-17T20:02:48-05:00	2014-12-17T20:02:48-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1941	17 Dec 17:30 Imaging experiment was started	ISR+Imaging		Acquisition system		new	2014-12-17T20:00:59-05:00	2014-12-17T20:00:59-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1940	17 Dec 17:00 Desincrozation Faraday	ISR		Acquisition system		new	2014-12-17T19:55:25-05:00	2014-12-17T19:55:25-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1939	17 Dec 15:21 VIPIR turned on	Other Instruments		Other Instruments		new	2014-12-17T19:54:06-05:00	2014-12-17T19:54:06-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1938	17 Dec 14:20 Calibration of ATR and TR	ISR		Antennas		new	2014-12-17T19:53:27-05:00	2014-12-17T19:53:27-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1937	17 Dec 14:00 Power source to the transmitter 1 OFF	ISR		Transmitters		new	2014-12-17T19:52:59-05:00	2014-12-17T19:52:59-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1936	17 Dec 13:00 VIPIR turned on	Other Instruments		Other Instruments		new	2014-12-17T19:50:10-05:00	2014-12-24T09:23:29-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1935	17 Dec 10:05 Calibration of ATR and TR	ISR		Antennas		new	2014-12-17T19:42:42-05:00	2014-12-17T19:42:42-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1934	17 Dec 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-12-17T19:40:44-05:00	2014-12-17T19:40:44-05:00	"09:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.3 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 300 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.9 dBm/ +5.3 dBm
4 +2.3 dBm
Voltage line and power: 4060 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.3 dBm
4 +2.5 dBm
Voltage line and power: 4060 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
14:05 Problem detected at PA1 screen power supply
15:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.1 dBm/ +5.4 dBm
4 +2.6 dBm
Voltage line and power: 4090 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4020 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm/ +5.3 dBm
4 +2.5 dBm
Voltage line and power: 4100 VAC, 300 KW
17:30 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.0 dBm
4 +2.5 dBm
D3 -5.6 dBm
Voltage line and power: 4080 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.0 dBm
4 +2.4 dBm
D3 -5.7 dBm
Voltage line and power: 4080 VAC, 290 KW"	ryaya
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1933	16 Dec 10:05 Calibration of ATR and TR	ISR		Antennas		new	2014-12-17T19:37:46-05:00	2014-12-17T19:37:46-05:00		jmayaute
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1932	17 Dec 07:59 TIEMPO DE OPERACION	ISR		General	jortiz	new	2014-12-17T08:06:57-05:00	2014-12-19T12:22:42-05:00	"Jefe de Turno: Jorge Ortiz
Experimento: EW_DRIFT-FARADAY-IMAGING
1) 08:00PM - 08:00AM
2) Tiempo de Operacion Normal: 12 horas
3) Tiempo de Para: 0 h
4) Motivo: N/A"	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1931	17 Dec 07:30 Transmitter power measurements	ISR+Imaging		Transmitters		new	2014-12-17T07:44:37-05:00	2014-12-17T07:44:37-05:00	"
 20:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm
 TX4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4070 VAC, 290 KW
 21:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm
 TX4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4070 VAC, 290 KW
 22:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm
 TX4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4070 VAC, 290 KW
 23:00 TX Power sample (-70 dB coupling)
 TX1 +5.2 dBm
 TX2 +1.9 dBm
 TX4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4070 VAC, 290 KW

 00:00 TX Power sample (-70 dB coupling)
 TX1 +5.2 dBm
 TX2 +1.9 dBm
 TX4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4070 VAC, 290 KW
 01:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm
 TX4 +2.4 dBm
 Dr3 -5.7 dBm
 Voltage line and power: 4070 VAC, 290 KW
 02:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm / +5.3 dBm
 TX4 +2.7 dBm
 Dr3 off
 Voltage line and power: 4070 VAC, 290 KW
 03:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm / +5.3 dBm
 TX4 +2.7 dBm
 Dr3 off
 Voltage line and power: 4070 VAC, 290 KW
 04:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm / +5.3 dBm
 TX4 +2.7 dBm
 Dr3 off
 Voltage line and power: 4070 VAC, 290 KW
 05:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm / +5.3 dBm
 TX4 +2.7 dBm
 Dr3 off
 Voltage line and power: 4070 VAC, 290 KW
 06:00 TX Power sample (-70 dB coupling)
 TX1 +5.3 dBm
 TX2 +2.0 dBm / +5.3 dBm
 TX4 +2.7 dBm
 Dr3 off
 Voltage line and power: 4070 VAC, 290 KW
 07:00 TX Power sample (-70 dB coupling)
 TX1 +5.5 dBm
 TX2 +2.0 dBm / +5.3 dBm
 TX4 +2.3 dBm
 Dr3 off
 Voltage line and power: 4070 VAC, 290 KW
"	rtadeo
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1930	17 Dec 07:16 Calibration of ATR and TR	ISR		Antennas	jortiz	new	2014-12-17T07:25:07-05:00	2014-12-17T07:25:07-05:00	Calibration of ATR and TR	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1929	17 Dec 03:20 Calibration of ATR and TR	ISR		Antennas	jortiz	new	2014-12-17T03:30:24-05:00	2014-12-17T03:30:24-05:00	Calibration of ATR and TR	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1928	17 Dec 00:15 End of Imaging	ISR		End experiment	jortiz	new	2014-12-17T00:55:04-05:00	2014-12-17T04:48:16-05:00	End of Imaging	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1927	16 Dec 23:59 Imaging Graphs	ISR		Process/Analysis Program	jortiz	new	2014-12-17T00:50:06-05:00	2014-12-17T00:51:25-05:00	Imaging Graphs	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1926	16 Dec 23:59 RTIs and Other Graphs	ISR		Process/Analysis Program	jortiz	new	2014-12-17T00:18:15-05:00	2014-12-17T00:18:15-05:00	RTIs and Other Graphs	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1925	16 Dec 23:03 Calibration of ATR and TR	ISR		Antennas	jortiz	new	2014-12-16T23:48:48-05:00	2014-12-16T23:48:48-05:00	Calibration of TR and ATR	jortiz
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1924	16 Dec 19:59 OPERACION RESUME	ISR		General	aaguilar	new	2014-12-16T23:12:54-05:00	2014-12-19T12:21:17-05:00	"Jefe de Turno: Alan Aguilar
Experimento: EW_DRIFT-FARADAY-IMAGING
1) 08:00AM - 08:00PM
2) Tiempo de Operacion Normal: 12 horas
3) Tiempo de Para: 0 h ??
4) Motivo: N/A"	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1923	16 Dec 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-12-16T19:45:54-05:00	2014-12-16T19:45:54-05:00	"08:47 Alarm at PA 1 screen power supply
10:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.2 dBm
Voltage line and power: 4060 VAC, 300 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.1 dBm/ +5.3 dBm
4 +2.4 dBm
Voltage line and power: 4030 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.5 dBm
Voltage line and power: 4100 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.1 dBm/ +5.4 dBm
4 +2.4 dBm
Voltage line and power: 4030 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.5 dBm
Voltage line and power: 4030 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.9 dBm/ +5.3 dBm
4 +2.3 dBm
Voltage line and power: 4050 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.0 dBm/ +5.4 dBm
4 +2.5 dBm
Voltage line and power: 4080 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.6 dBm
Voltage line and power: 4080 VAC, 300 KW
17:40 Driver 3 ON (IMAGING)
18:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.2 dBm
4 +2.6 dBm
D3 -5.8 dBm
Voltage line and power: 4060 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +2.3 dBm
4 +2.6 dBm
D3 -5.6 dBm
19:10 Problem at Driver 1, overcurrent detected on screen power supply."	ryaya
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1922	16 Dec 19:10 Sobrecorriente en el driver 1	ISR		Transmitters		new	2014-12-16T19:30:34-05:00	2014-12-16T19:30:34-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1921	16 Dec 19:05 Spark Gap Adjustment	ISR		Antennas		new	2014-12-16T19:27:18-05:00	2014-12-19T12:27:15-05:00	"16 Dec 12:17 Spark Gap Adjustment
16 Dec 16:07 Spark Gap Adjustment
16 Dec 19:05 Spark Gap Adjustment"	aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1920	16 Dec 17:45 Se activo la adquisicion de Imaging	ISR+Imaging		Start experiment		new	2014-12-16T19:26:27-05:00	2014-12-16T19:26:27-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1919	16 Dec 17:17 Hubo unas pruebas de VIPIR a las 16:41 ; 16:47 ; 17:19	ISR		General		new	2014-12-16T19:25:25-05:00	2014-12-16T19:25:25-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1917	16 Dec 13:35 Se desincronizo Faraday, se reinicio la adquisicion	ISR		Acquisition system		new	2014-12-16T19:17:38-05:00	2014-12-16T19:17:38-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1915	16 Dec 10:04  Se corrigio el sincronismo de Faraday, reiniciando el Controlador de Radar	ISR		Acquisition system		new	2014-12-16T18:46:36-05:00	2014-12-16T18:46:36-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1914	16 Dec 09:20 Se perdio el sincronismo en Faraday.	ISR		Acquisition system		new	2014-12-16T18:44:24-05:00	2014-12-16T18:44:24-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1913	16 Dec 09:19  Se reinicio sola la PC de Faraday. Se reinicia adquisicion	ISR		Acquisition system		new	2014-12-16T18:42:34-05:00	2014-12-16T18:42:34-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1912	16 Dec 09:09 Ajuste de ATR y TR	ISR		Antennas		new	2014-12-16T18:33:32-05:00	2014-12-16T18:39:33-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1911	16 Dec 08:48 Transmisor 1 Failure	ISR		Transmitters		new	2014-12-16T18:27:58-05:00	2014-12-19T12:13:10-05:00		aaguilar
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1909	16 Dec 07:33 Desincrozation Faraday	ISR		Acquisition system	P. Condor	new	2014-12-16T08:05:35-05:00	2014-12-16T08:05:35-05:00	Desincrozation Faraday	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1908	16 Dec 07:22 Channel D is OK.	ISR		Reception	P. Condor	new	2014-12-16T08:03:20-05:00	2014-12-19T12:07:50-05:00	"16 Dec 07:05 Change of TR of channel D. But not is the solution.

Channel D is OK. After of many tries. There is any slack cable? Also Ch B is affected when do the changes."	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1907	16 Dec 08:00 Operation Resume	ISR		Reception	P. Condor	new	2014-12-16T07:58:25-05:00	2014-12-21T05:16:58-05:00	"Person in charge: P. Condor
Experiment: EW Drift-Faraday-Imaging
1)Time: 20:00 - 08:00
2) Operation Hours: 11 h 59´
3)Operation incomplete: 1´
4)Reasons: 
_ Transmitter Failure (1 min)"	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1906	16 Dec 06:55 Noise channel D of EW_drifts low 2 db	ISR		Reception	P. Condor	new	2014-12-16T07:57:07-05:00	2014-12-16T07:57:07-05:00	Noise channel D of EW_drifts low 2 db	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1905	16 Dec 06:15 Spark Gap adjustment	ISR		Antennas	P. Condor	new	2014-12-16T07:55:03-05:00	2014-12-19T11:56:39-05:00	"16 Dec 01:45 Spark Gap adjustment
16 Dec 06:15 Spark Gap adjustment"	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1903	16 Dic 07:05 Transmitter Power Measurements	ISR+Imaging		Transmitters		new	2014-12-16T07:15:58-05:00	2014-12-16T07:15:58-05:00	" 
 21:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.3 dBm
 Tx4 +2.6 dBm
 Dr3 -5.6 dBm
 Line voltage and power: 4050 VAC, 300 KW
 22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.2 dBm
 Tx4 +2.6 dBm
 Dr3 -5.6 dBm
 Line voltage and power: 4050 VAC, 300 KW
 23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.2 dBm
 Tx4 +2.6 dBm
 Dr3 -5.7 dBm
 Line voltage and power: 4050 VAC, 300 KW
12/16/2014
 00:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.2 dBm
 Tx4 +2.6 dBm
 Dr3 -5.7 dBm
 Line voltage and power: 4100 VAC, 295 KW
 01:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +1.6 dBm / +5.2 dBm
 Tx4 +2.5 dBm
 Dr3 off
 Line voltage and power: 4100 VAC, 295 KW
 02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +1.6 dBm / +5.2 dBm
 Tx4 +2.5 dBm
 Dr3 off
 Line voltage and power: 4100 VAC, 295 KW
 03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.1 dBm / +5.5 dBm
 Tx4 +2.6 dBm
 Dr3 off
 Line voltage and power: 4090 VAC, 290 KW
 04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.1 dBm / +5.5 dBm
 Tx4 +2.6 dBm
 Dr3 off
 Line voltage and power: 4090 VAC, 290 KW
 05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.1 dBm / +5.5 dBm
 Tx4 +2.6 dBm
 Dr3 off
 Line voltage and power: 4090 VAC, 290 KW
 06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.1 dBm / +5.5 dBm
 Tx4 +2.6 dBm
 Dr3 off
 Line voltage and power: 4090 VAC, 290 KW
 07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.2 dBm / +5.6 dBm
 Tx4 +2.6 dBm
 Dr3 off
 Line voltage and power: 4100 VAC, 300 KW


"	rtadeo
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1902	16 Dec 00:00 Figures Faraday	ISR		Process/Analysis Program	P. Condor	new	2014-12-16T04:23:48-05:00	2014-12-16T04:23:48-05:00	Figures Faraday of SignalChain	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1901	16 Dec 00:56 End of Imaging	ISR		Acquisition system	P. Condor	new	2014-12-16T01:56:29-05:00	2014-12-16T01:56:29-05:00	End of Imaging	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1900	15 Dec 23:59 Figures of Imaging	ISR		Process/Analysis Program	P. Condor	new	2014-12-16T01:55:02-05:00	2014-12-16T01:55:02-05:00	Figures of Imaging	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1899	15 Dec 23:59 Figures of rtis and others	ISR		Process/Analysis Program	P. Condor	new	2014-12-16T01:48:21-05:00	2014-12-16T01:48:21-05:00	Figures of rtis and others	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1898	15 Dec 22:17 Change of TR of channel D	ISR		Reception	P. Condor	new	2014-12-16T01:47:23-05:00	2014-12-19T11:54:22-05:00	"Problem Started: 22:05
Problem Fixes:   22:17
Change of TR of channel D. It was not working and had slack cable."	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1897	15 Dec 22:10 Spark Gaps adjustment	ISR		Antennas	J. Lavado	new	2014-12-16T01:43:11-05:00	2014-12-19T11:51:00-05:00	"15 Dec 18:57 Spark Gaps adjustment
15 Dec 22:10 Spark Gaps adjustment"	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1896	15 Dec 22:08 Falls Transmitter of EW_Drifts	ISR		Transmitters	P. Condor	new	2014-12-16T01:42:21-05:00	2014-12-21T04:29:39-05:00	Falls Transmitter of EW_Drifts of 1 minute.	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1895	15 Dec 22:05  Noise Channel D-EW_Drifts rises more of 2 db	ISR		Reception	P. Condor	new	2014-12-16T01:40:56-05:00	2014-12-16T01:40:56-05:00	Noise Channel D-EW_Drifts rises more of 2 db	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1894	15 Dec 21:20 Digisonde every 5 min	ISR		Other Instruments	P. Condor	new	2014-12-16T01:38:22-05:00	2014-12-16T01:38:22-05:00	Digisonde every 5 min	pcondor
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1893	15 Dec 19:59 Operation time	ISR+Imaging		General	I. Manay	new	2014-12-15T20:10:02-05:00	2014-12-15T20:10:02-05:00	"Shift manager : Ivan Manay
Experiment : EW_Drift + Faraday + Imaging

1) Shift time : 16:40 - 20:00
2) Normal operation time : 3h 57""
3) Stop time : 3""
4) Stop reasons:
     Fall of the transmitter."	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1892	15 Dec 19:23 Transmitter failure	ISR+Imaging		Transmitters	I. Manay	new	2014-12-15T19:35:49-05:00	2014-12-19T11:04:39-05:00	"19:23 Transmitter falls
19:26 Transmitter on"	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1891	15 Dic 19:05 Transmitter Power Measurements	ISR		Transmitters	V. Quezada	new	2014-12-15T19:14:42-05:00	2014-12-15T20:08:00-05:00	"'''15 December 2014'''
11:50  LV ON
13:32  HV ON
13:45 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.3 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 87 ºF, LP: 89 ºF
14:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.3 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 87 ºF, LP: 89 ºF
14:09  HV OFF
15:45  HV ON
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +1.5,5.0 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 87 ºF, LP: 88 ºF
17:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.6 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 87 ºF, LP: 88 ºF
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.6 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 87 ºF, LP: 88 ºF
19:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.6 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 87 ºF, LP: 88 ºF"	vquesada
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1889	15 Dec 17:48 Imaging experiment was started	ISR+Imaging		Reception	I. Manay	new	2014-12-15T18:59:21-05:00	2014-12-15T19:01:59-05:00		imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1888	15 Dec 17:08 Interference observed at EW_drift experiment	ISR+Imaging		Reception	I. Manay	new	2014-12-15T18:56:56-05:00	2014-12-15T18:56:56-05:00	It could be related to the first imaging tests.	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1887	15 Dec 16:40 Start of the experiment	ISR+Imaging		Start experiment	I. Manay	new	2014-12-15T18:52:59-05:00	2014-12-15T18:52:59-05:00	"EW_Drift experiment started earlier(16:00). Adjusments at the reception lines of Faraday experiment was necessary.

Next, the '''antenna measurements''' (VSWR):

SUP : 1.02
SDW : 1.05
EDW : 1.04
EUP : 1.04
NUP : 1.04
NDW : 1.04
WDW : 1.03
WUP : 1.02

And the '''attenuations''' used at the reception lines:

EW_drift:
CHA : 0dB
CHB : 0dB
CHC : 0dB
CHD : 0dB

Faraday:
CHE : 7dB
CHF : 9dB"	imanay
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1886	15 Dec 11:30 Antenna VSWR	ISR		Antennas	ryanque	new	2014-12-15T11:43:32-05:00	2014-12-15T11:45:00-05:00	"SUP 1.02 - 1.01 49.90
SDN 1.05 - 1.01 49.96
EDN 1.04 - 1.02 49.97
EUP 1.04 - 1.02 49.87
NUP 1.04 - 1.02 49.95
NDN 1.04 - 1.01 49.96
WDN 1.03 - 1.02 49.93
WUP 1.02 - 1.00 49.94"	ryanque
Milestone 2014_12 ISCOD Northern Deeper Winter Dic 15-22	1885	15 Dec 10:00 Log created	ISR		Start experiment	ryanque	new	2014-12-15T08:58:32-05:00	2014-12-15T11:44:22-05:00	"Campaign Northern Deeper Winter (ISCOD)
December 15 - 22
Local User: D. Suarez, P. Condor
Mode: Imaging + ISR

Starts: December 15 17:00 (LT)
Ends:   Decembre 22 08:05 (LT)"	ryanque
Milestone 2014_11 ISR + Imaging Nov 24-28	2074	22 Jan 12:30 Data was uploaded to PUMA	ISR+Imaging		General	I. Manay	new	2015-01-22T15:15:44-05:00	2015-01-22T15:15:44-05:00	"'''EW_dift:'''
1559 files, 111 GB
'''Faraday:'''
630 files, 32.2 GB
'''Imaging:'''
269 files, 210 GB"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1884	28 Nov 08:05 Experiment finished	ISR		General	ryanque	new	2014-12-11T11:17:05-05:00	2014-12-11T11:18:19-05:00	The experiment has finished	ryanque
Milestone 2014_11 ISR + Imaging Nov 24-28	1883	28 Nov 07:58 Faraday Te and Ti	ISR		Process/Analysis Program	ryanque	new	2014-11-28T15:45:13-05:00	2014-11-28T15:45:13-05:00	"It looks like Te and Ti isn´t not calculated good even though Ne looks Ok.

L. Condori (Local user) says it should be noise that is causing this. At rawdata noise is being removed. This ocurrs at some hours. "	ryanque
Milestone 2014_11 ISR + Imaging Nov 24-28	1882	27 Nov 23:59 Figures of rtis, noises and others	ISR		Plot	AValdez	new	2014-11-28T03:27:09-05:00	2014-12-03T13:23:35-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1881	28 Nov 04:00am SPARK GAPS ADJUSTMENT	ISR		Spark Gaps	AValdez	new	2014-11-28T03:24:01-05:00	2014-11-28T03:24:01-05:00		Avaldez
Milestone 2014_11 ISR + Imaging Nov 24-28	1880	28 Nov 03:20am Fall of the transmitters	ISR+Imaging		Transmitters	AValdez	new	2014-11-28T03:23:00-05:00	2014-11-28T03:24:33-05:00		Avaldez
Milestone 2014_11 ISR + Imaging Nov 24-28	1879	28 Nov 01:00 Imaging experiment turned off	ISR+Imaging		Acquisition system	AValdez	new	2014-11-28T03:21:13-05:00	2014-12-03T13:22:47-05:00		Avaldez
Milestone 2014_11 ISR + Imaging Nov 24-28	1878	28 Nov 07:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-11-28T02:54:23-05:00	2014-12-03T13:22:05-05:00	"'''28 November 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 300 KW
Temp HP: 81 ºF, LP: 80 ºF
01:00 RF Driver 4 OFF
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 80 ºF, LP: 79 ºF
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 80 ºF, LP: 79 ºF
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 80 ºF, LP: 79 º
03:20 Crowbar por caida de tensio
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5,5.6 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.5,5.6 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 78 ºF, LP: 77 ºF
"	vquesada
Milestone 2014_11 ISR + Imaging Nov 24-28	1877	27 Nov 23:13 Transmitter Power Measurements	ISR		Transmitters		new	2014-11-27T18:58:14-05:00	2014-11-27T18:58:14-05:00	"'''27 November 2014'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.0 dBm
D3 -5.8 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 84 ºF, LP: 81 ºF
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.0 dBm
D3 -5.8 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 84 ºF, LP: 81 ºF
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.0 dBm
D3 -5.8 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 83 ºF, LP: 80 ºF
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.0 dBm
D3 -5.8 dBm
Line voltage and power: 4050 VAC, 300 KW
Temp HP: 83 ºF, LP: 80 ºF"	vquesada
Milestone 2014_11 ISR + Imaging Nov 24-28	1876	27 Nov 19:15 Transmitter Power Measurements	ISR+Imaging		Transmitters		new	2014-11-27T14:59:22-05:00	2014-11-27T14:59:22-05:00	"2014_11 ISR + Imaging Nov 24-28  

27 November 2014
 08:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.2/+5.1 dBm
 Tx4 +2.4 dBm
 D3  RF (Off)
 Line voltage and power: 4080 VAC, 300 KW
08:36 RF OFF Cooling system failure
 10:48 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.2/+5.1 dBm
 Tx4 +2.0 dBm
 D3  RF (Off)
 Line voltage and power: 4060 VAC, 280 KW
 12:00 TX Power sample (-70 dB coupling)
 Tx1 +5.0 dBm
 Tx2 +1.9/+5.2 dBm
 Tx4 +2.0 dBm
 D3  RF (Off)
 Line voltage and power: 4060 VAC, 280 KW
 14:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.2/+5.1 dBm
 Tx4 +2.0 dBm
 D3  RF (Off)
 Line voltage and power: 4000 VAC, 280 KW
 15:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.0/+5.1 dBm
 Tx4 +2.1 dBm
 D3  RF (Off)
 Line voltage and power: 4100 VAC, 290 KW
 16:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.2/+5.5 dBm
 Tx4 +2.2 dBm
 D3  RF (Off)
 Line voltage and power: 4100 VAC, 290 KW
 17:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.2/+5.5 dBm
 Tx4 +2.2 dBm
 D3   RF (Off)
 Line voltage and power: 4100 VAC, 300 KW
 18:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm
 Tx4 +2.1 dBm
 D3  -5.6 dBm
 Line voltage and power: 4000 VAC, 290 KW
 19:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm
 Tx4 +2.1 dBm
 D3  -5.6 dBm
 Line voltage and power: 4000 VAC, 290 KW
 

"	rtadeo
Milestone 2014_11 ISR + Imaging Nov 24-28	1875	27 Nov 18:25 PC of ew_drift experiment was restarted	ISR		Acquisition system	I. Manay	new	2014-11-27T14:20:49-05:00	2014-11-27T14:20:49-05:00	There were not data from 18:18 to 18:25.	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1874	27 Nov 17:45 Imaging experiment has started	ISR		Acquisition system	I. Manay	new	2014-11-27T13:39:13-05:00	2014-11-27T13:48:13-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1873	27 Nov 17:08 End of the moon pass	ISR		General	I. Manay	new	2014-11-27T13:21:08-05:00	2014-11-27T13:29:44-05:00	The moon pass started at 16:35 and it finished at 17:08. First it was observed at C and D channel, then A and B.	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1872	27 Nov 16:12 Spark gaps adjustment	ISR		Spark Gaps	J. Lavado	new	2014-11-27T13:11:16-05:00	2014-12-11T11:20:57-05:00	"Spark gaps adjustment 
27 Nov 12:30 "	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1871	27 Nov 15:40 Interferences at B channel of ew_drift experiment	ISR		Process/Analysis Program	I. Manay	new	2014-11-27T13:10:13-05:00	2014-11-27T13:10:13-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1869	27 Nov 10:40 Experiment was restarted	ISR		General	I. Manay	new	2014-11-27T08:20:12-05:00	2014-12-03T17:35:51-05:00	02:10 Hours the Experiment was turned off	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1868	27 Nov 08:36 Transmitter OFF	ISR		Transmitters	P. Condor	new	2014-11-27T06:28:17-05:00	2014-12-03T17:34:46-05:00	 Transmitter OFF for the repair of cooling system	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1867	27 Nov 07:08 Transmitter Power Measurements	ISR		Transmitters		new	2014-11-27T02:51:45-05:00	2014-11-27T02:51:45-05:00	"'''27 November 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -5.6 dBm
Line voltage and power: 4050 VAC, 300 KW
00:10 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.4 dBm
Line voltage and power: 4080 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3,5.5 dBm
Tx4 +2.4 dBm
Line voltage and power: 4080 VAC, 300 KW
02:42 Falla 1ntercambiador 1 se rompe eje.
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.3,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2,5.4 dBm
Tx4 +2.4 dBm
Line voltage and power: 4100 VAC, 300 Kw"	vquesada
Milestone 2014_11 ISR + Imaging Nov 24-28	1866	27 Nov 00:20 Transmitter Power Measurements	ISR		Transmitters		new	2014-11-26T20:04:35-05:00	2014-11-26T20:04:35-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3 dBm
Tx4 +2.1 dBm
D3  -5.8 dBm
Line voltage and power: 4050 VAC, 300 KW
20:40 HV OFF
1)Se quema cable de una fase de salida 440 Vac del variac de la fuente de filamento Tx2.
2)Problemas en el sensor de flujo del Tx4, no habilita la secuencuencia, se purga y despues ok.
22:35 HV ON, Txs OK
22:45 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3  -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
23:30 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3  -5.6 dBm
Line voltage and power: 4080 VAC, 300 KW
"	vquesada
Milestone 2014_11 ISR + Imaging Nov 24-28	1865	26 Nov 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-11-26T15:19:47-05:00	2014-11-26T15:19:47-05:00	"26 Nov

08:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 300 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 300 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +2.1,5.2 dBm
Tx4 +2.0 dBm
Line voltage and power: 4020 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 300 KW
11:50 Failure at exchanger 2, does not compromise the transmitters operation.
12:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +2.2,5.4 dBm
Tx4 +2.0 dBm
Line voltage and power: 4000 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +2.2,5.4 dBm
Tx4 +2.0 dBm
Line voltage and power: 4000 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +2.1,5.4 dBm
Tx4 +2.1 dBm
Line voltage and power: 4000 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.3,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.3,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4040 VAC, 300 KW
17:45 Drv3 ON -5.8 dBm
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.4 dBm
Tx4 +2.2 dBm
Dr3 -5.6 dBm
Line voltage and power: 4060 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.5 dBm
Tx4 +2.3 dBm
Dr3 -5.6 dBm
Line voltage and power: 4100 VAC, 300 KW"	ryaya
Milestone 2014_11 ISR + Imaging Nov 24-28	1864	26 Nov 20:46 TX Down	ISR		Transmitters		new	2014-11-26T14:29:54-05:00	2014-12-11T11:34:16-05:00	"The system was down due to a failure in Faraday transmitter.
At 22:38 the system was started."	ryanque
Milestone 2014_11 ISR + Imaging Nov 24-28	1863	26 Nov 15:15 Spark Gaps Adjusment	ISR		Spark Gaps		new	2014-11-26T14:04:05-05:00	2014-12-19T11:44:50-05:00	"26 Nov 15:15 Spark Gaps Adjusment
26 Nov 18:45 Spark Gaps Adjusment"	jmayaute
Milestone 2014_11 ISR + Imaging Nov 24-28	1862	26 Nov 10:30 Spark Gaps Adjusment	ISR		Spark Gaps		new	2014-11-26T13:34:05-05:00	2014-11-26T13:34:05-05:00		jmayaute
Milestone 2014_11 ISR + Imaging Nov 24-28	1861	24 Nov 19:30 Start of the experiment	ISR		Start experiment	I. Manay	new	2014-11-26T10:09:13-05:00	2014-12-03T16:07:42-05:00	"The data of the Faraday experiment were ok after a mistake at the ues section was corrected. Three lengths at this section were changed. The data of the ew_drift experiment could also be affected.
Experiment should start: 05:00 pm
There were 02:30 Hours of delay"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1860	26 Nov 07:37 Restart Faraday Batch	ISR		Acquisition system	P. Condor	new	2014-11-26T03:38:38-05:00	2014-11-26T03:38:38-05:00	Restart Faraday Batch for desynchronization	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1859	26 Nov 07:30 Batch of Faraday restart	ISR		Acquisition system	P. Condor	new	2014-11-26T03:36:37-05:00	2014-11-26T03:36:37-05:00	 Batch of Faraday restart	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1858	26 Nov 07:28 Problem with Driver 1 screen	ISR		Transmitters	P. Condor	new	2014-11-26T03:35:19-05:00	2014-11-26T03:35:19-05:00	Problem with Driver 1 screen. EW_drifts was affected.	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1857	26 Nov 06:45 Calibration of ATRs and Trs	ISR		Antennas	J. Lavado	new	2014-11-26T03:33:52-05:00	2014-11-26T03:33:52-05:00	Calibration of ATRs and Trs	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1856	26 Nov 05:45 Restart Faraday	ISR		Acquisition system	P. Condor	new	2014-11-26T03:32:04-05:00	2014-11-26T03:32:04-05:00	Restart Faraday	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1855	26 Nov 07:20 Transmitter power measurements	ISR+Imaging		Transmitters		new	2014-11-26T03:04:14-05:00	2014-11-26T03:04:14-05:00	"25 November 2014
 20:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dr3 -5.8 dBm
 Line voltage and power: 4100 VAC, 300 KW
 21:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.5 dBm
 Tx4 +2.2 dBm
 Dr3 -5.7 dBm
 Line voltage and power: 4100 VAC, 300 KW
 22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.5 dBm
 Tx4 +2.2 dBm
 Dr3 -5.7 dBm
 Line voltage and power: 4100 VAC, 300 KW
 23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.5 dBm
 Tx4 +2.2 dBm
 Dr3 -5.7 dBm
 Line voltage and power: 4100 VAC, 300 KW
26 November 2014
 00:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.3 dBm
 Tx4 +2.1 dBm
 Dr3 -5.5 dBm
 Line voltage and power: 4050 VAC, 290 KW
 01:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.4 dBm
 Tx4 +2.2 dBm
 Dr3 -5.6 dBm
 Line voltage and power: 4100 VAC, 300 KW
 02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.4 dBm
 Tx4 +2.2 dBm
 Dr3 -5.6 dBm
 Line voltage and power: 4100 VAC, 300 KW
 03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.4 dBm
 Tx4 +2.2 dBm
 Dr3 -5.6 dBm
 Line voltage and power: 4100 VAC, 300 KW
 04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.4 dBm
 Tx4 +2.2 dBm
 Dr3 -5.6 dBm
 Line voltage and power: 4100 VAC, 300 KW
 05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.4 dBm / -5.7 dBm
 Tx4 +2.2 dBm  
 Dr3  RF (OFF)
 Line voltage and power: 4100 VAC, 300 KW
 06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.2 dBm / -5.6 dBm
 Tx4 +2.0 dBm  
 Dr3  RF (OFF)
 Line voltage and power: 4000 VAC, 290 KW
 07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.3 dBm / -5.7 dBm
 Tx4 +2.2 dBm  
 Dr3  RF (OFF)
 Line voltage and power: 4100 VAC, 300 KW





"	rtadeo
Milestone 2014_11 ISR + Imaging Nov 24-28	1854	26 Nov 02:30 Calibration of ATRs and TRs	ISR		Antennas	J. Lavado	new	2014-11-26T01:04:02-05:00	2014-11-26T01:04:02-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1853	26 Nov 02:13 Imaging Off	ISR		Acquisition system	P. Condor	new	2014-11-26T01:02:00-05:00	2014-11-26T01:02:00-05:00	Imaging OFF	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1852	26 Nov 00:00 Figures of rtis, noises and others	ISR		Process/Analysis Program	P. Condor	new	2014-11-26T00:52:04-05:00	2014-11-26T00:52:04-05:00	Figures of rtis, noises and others	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1851	25 Nov 22:40  Calibration of ATr and Trs	ISR		Start experiment	J. Lavado	new	2014-11-26T00:50:44-05:00	2014-11-26T00:50:44-05:00	Calibration of ATr and Trs	pcondor
Milestone 2014_11 ISR + Imaging Nov 24-28	1850	25 Nov 19:30 Transmitter power measurements	ISR		Transmitters		new	2014-11-25T15:34:54-05:00	2014-11-25T15:34:54-05:00	"25 November 2014

08:00 Problem detected at PA 4. Flow meter sensor is not working properly. High pressure variable adjusted on PLC program. While fixing the problem at PA 4, a problem on filament cooling of PA 2 was detected. PA 2 is turned off for unit safety. 

09:00 Operation continues using just PA 1 (EW Drift)

11:45 Problem at PA 2 was fixed. Transmitter system restarted. 
12:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.0,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4000 VAC, 300 KW
12:05 Problem at PA 1 screen power supply.
13:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4000 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 310 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.2,5.5 dBm
Tx4 +2.1 dBm
Line voltage and power: 4050 VAC, 310 KW
17:30 Drv3 ON -5.8 dBm
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
Dr3 -5.8 dBm

19:00 TX Power sample (-70 dB coupling)
Tx1 +5.4 dBm
Tx2 +2.2 dBm
Tx4 +2.2 dBm
Dr3 -5.8 dBm
Line voltage and power: 4090 VAC, 300 KW"	ryaya
Milestone 2014_11 ISR + Imaging Nov 24-28	1849	25 Nov 12:04 Restart of the Faraday acquisition system	ISR		Acquisition system	I. Manay	new	2014-11-25T09:03:41-05:00	2014-11-25T09:04:04-05:00	"Data was not synchronized.
"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1848	25 Nov 11:30 Faraday on - ISR Complete	ISR		General	I. Manay	new	2014-11-25T09:00:31-05:00	2014-12-03T15:54:44-05:00	"Faraday experiment was enabled.
03:30 Hours off"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1847	25 Nov 09:40 Fall of the transmitters	ISR		Transmitters	I. Manay	new	2014-11-25T06:21:13-05:00	2014-11-25T06:21:13-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1846	25 Nov 09:18 Fall of the transmitters	ISR		Transmitters	I. Manay	new	2014-11-25T05:54:54-05:00	2014-11-25T06:20:48-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1845	25 Nov 09:00 Only EW Drift on	ISR		General	I. Manay	new	2014-11-25T05:54:03-05:00	2014-12-03T15:53:02-05:00	"Transmitters of Faraday experiment needed of maintenance. Only EW_Drift experiment is going.
08:00 Turned off
01 Hour off"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1844	25 Nov 08:01 Transmitters were down due to adjustments	ISR		Transmitters		new	2014-11-25T05:44:25-05:00	2014-11-25T05:47:42-05:00	The checking of the transmitter system was necessary due to the many falls at early hours.	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1843	25 Nov 07:32 Transmitters enabled	ISR		Transmitters		new	2014-11-25T03:28:59-05:00	2014-11-25T03:28:59-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1842	25 Nov 07:27 Transmitters disabled	ISR		Transmitters		new	2014-11-25T03:28:05-05:00	2014-11-25T03:28:05-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1841	25 Nov 07:10 Transmitters enabled	ISR		Transmitters		new	2014-11-25T03:26:58-05:00	2014-11-25T03:26:58-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1840	25 Nov 07:05 Transmitters disabled	ISR		Transmitters		new	2014-11-25T03:26:16-05:00	2014-11-25T03:26:16-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1839	24 Nov 19:30 Transmitter Power Measurements	ISR+Imaging		Transmitters		new	2014-11-25T02:59:35-05:00	2014-11-26T09:03:28-05:00	"
24 November 2014
 20:50 Failure by variation of AC line
 21:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Drv3-5.8 dBm
 Line voltage and power: 4050 VAC, 300 KW
 21:25 TX Failure by variation of AC line

 22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.2 dBm
 Tx4 +2.3 dBm
 D3 -5.6 dbm
 Line voltage and power: 4100 VAC, 300 KW
 23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.2 dBm
 Tx4 +2.3 dBm
 D3 -5.6 dbm
 Line voltage and power: 4100 VAC, 300 KW

25 November 2014
 00:30 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.5 dBm /+5.9 dBm
 Tx4 +2.3 dBm
 D3  RF off
 Line voltage and power: 4100 VAC, 310 KW
 01:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.5 dBm /+5.8 dBm
 Tx4 +2.3 dBm
 D3  RF off
 Line voltage and power: 4100 VAC, 300 KW
 02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.5 dBm /+5.8 dBm
 Tx4 +2.3 dBm
 D3  RF off
 Line voltage and power: 4100 VAC, 300 KW
 00:20 fails PA 4
 00:50 fails PA 4
 03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.3 dBm /+5.5 dBm
 Tx4 +2.3 dBm
 D3  RF off
 Line voltage and power: 4070 VAC, 295 KW
 03:25 fails PA 4
 04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm /+5.5 dBm
 Tx4 +2.2 dBm
 D3  RF off
 Line voltage and power: 4070 VAC, 295 KW
 04:05 fails PA 4
 04:25 fails PA 4
 05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm /+5.5 dBm
 Tx4 +2.2 dBm
 D3  RF off
 Line voltage and power: 4050 VAC, 290 KW
 05:30 fails PA 4
 06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm /+5.5 dBm
 Tx4 +2.2 dBm
 D3  RF off
 Line voltage and power: 4050 VAC, 290 KW
 07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.1 dBm /+5.4 dBm
 Tx4 +2.0 dBm
 D3  RF off
 Line voltage and power: 4100 VAC, 300 KW
 07:00 fails PA 4
 07:05 fails PA 4
 




"	rtadeo
Milestone 2014_11 ISR + Imaging Nov 24-28	1838	25 Nov 05:35 Transmitters enabled	ISR		Transmitters		new	2014-11-25T01:47:40-05:00	2014-11-25T01:47:40-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1837	25 Nov 05:30 Transmitters disabled	ISR		Transmitters		new	2014-11-25T01:46:31-05:00	2014-11-25T01:46:31-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1836	25 Nov 04:40 Spark gaps adjusment	ISR		Spark Gaps		new	2014-11-25T01:45:18-05:00	2014-11-25T01:45:18-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1835	25 Nov 04:33 Transmitters enabled	ISR		Transmitters		new	2014-11-25T01:44:06-05:00	2014-11-25T01:44:06-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1834	25 Nov 04:25 Transmitters disabled	ISR		Transmitters		new	2014-11-25T01:33:17-05:00	2014-11-25T01:33:17-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1833	25 Nov 04:13 Transmitters enabled	ISR		Transmitters		new	2014-11-25T01:32:29-05:00	2014-11-25T01:32:29-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1832	25 Nov 04:05 Transmitters disabled	ISR		Transmitters		new	2014-11-25T01:31:38-05:00	2014-11-25T01:31:38-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1831	25 Nov 03:30 Transmitters enabled	ISR		Transmitters		new	2014-11-25T01:29:18-05:00	2014-11-25T01:29:18-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1830	25 Nov 03:25 Transmitters disabled	ISR		Transmitters		new	2014-11-25T01:28:07-05:00	2014-11-25T01:28:07-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1829	25 Nov 03:05 TR change, EW drift channel A is OK	ISR		Transmitters		new	2014-11-25T01:27:12-05:00	2014-11-25T01:27:12-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1828	25 Nov 02:59 Transmitters enabled	ISR		Transmitters		new	2014-11-25T01:25:34-05:00	2014-11-25T01:25:34-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1827	25 Nov 02:51  Transmitters disabled	ISR		Transmitters		new	2014-11-25T01:24:40-05:00	2014-11-25T01:24:40-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1826	25 Nov 02:40  TR change, EW drift channel D is OK	ISR		Transmitters		new	2014-11-25T01:23:34-05:00	2014-11-25T01:23:34-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1825	25 Nov 02:30  Transmitters enabled. EW drift channel D is attenuated.	ISR		Transmitters		new	2014-11-25T01:13:48-05:00	2014-11-25T01:22:17-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1824	25 Nov 02:20 Transmitters disabled	ISR		Transmitters		new	2014-11-25T01:12:58-05:00	2014-11-25T01:12:58-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1823	25 Nov 01:05  Ares PC restored	ISR		Acquisition system		new	2014-11-25T01:12:01-05:00	2014-11-25T01:12:01-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1822	25 Nov 01:03  Ares PC stops	ISR		Acquisition system		new	2014-11-25T01:11:17-05:00	2014-12-03T13:25:08-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1821	25 Nov 00:30 Imaging experiment turned off	ISR		Acquisition system		new	2014-11-25T01:10:14-05:00	2014-11-25T01:10:14-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1820	25 Nov 00:00 Figures of noise, rtis and others	ISR		Plot		new	2014-11-25T00:51:11-05:00	2014-11-25T00:51:11-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1819	25 Nov 00:00  ATR and TR calibration	ISR		Spark Gaps		new	2014-11-25T00:28:02-05:00	2014-11-25T00:28:02-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1818	24 Nov 21:35 Transmitters enabled	ISR		Transmitters		new	2014-11-25T00:26:21-05:00	2014-11-25T00:26:21-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1817	24 Nov 21:28 Transmitters disabled	ISR		Transmitters		new	2014-11-25T00:23:53-05:00	2014-11-25T00:23:53-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1816	24 Nov 21:00   Transmitters enabled	ISR		Transmitters		new	2014-11-25T00:22:20-05:00	2014-12-03T15:10:59-05:00	"Transmitter disabled 20:55
Transmitter enabled  21:00"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1815	24 Nov 20:55 Transmitters disabled	ISR		Transmitters		new	2014-11-25T00:13:16-05:00	2014-11-25T00:13:16-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1814	24 Nov 20:50   ATR and TR calibration	ISR		Spark Gaps		new	2014-11-25T00:08:56-05:00	2014-11-25T00:16:57-05:00		imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1813	24 Nov 19:30 Transmitter Power Measurements	ISR		Transmitters		new	2014-11-24T15:13:57-05:00	2014-11-26T09:02:49-05:00	"'''24 November 2014'''
14:45  LV   ON
17:00  HV   ON
17:00 TX Power sample (-70 dB coupling)
Tx1 +5.0 dBm
Tx2 +2.2,5.3 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 KW
17:30 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3  -5.6 dbm
Line voltage and power: 4090 VAC, 310 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3  -5.6 dbm
Line voltage and power: 4090 VAC, 310 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +5.1 dBm
Tx2 +2.2 dBm
Tx4 +2.3 dBm
D3  -5.6 dbm
Line voltage and power: 4090 VAC, 310 KW
19:03 HV OFF
19:18 HV ON
19:18 TX Power sample (-70 dB coupling)
Tx1 +5.3 dBm
Tx2 +2.1 dBm
Tx4 +2.2 dBm
D3  -5.6 dbm
Line voltage and power: 4100 VAC, 310 KW"	vquesada
Milestone 2014_11 ISR + Imaging Nov 24-28	1812	24 Nov 15:00 Antenna VSWR	ISR		Antennas		new	2014-11-24T10:51:16-05:00	2014-11-24T10:51:16-05:00	"Wup : 1.03
Wdw : 1.09
Ndw : 1.03
Nup : 1.06
Eup : 1.02
Edw : 1.06
Sdw : 1.09
Sup : 1.02"	imanay
Milestone 2014_11 ISR + Imaging Nov 24-28	1811	21 Nov 11:40 Log created	ISR		Start experiment	ryanque	new	2014-11-21T07:24:32-05:00	2014-11-21T07:32:07-05:00	"The log has been created for the ISR + Imaging Campaign from November 24 to 28

Local User: Percy Condor"	ryanque
Milestone 2014_09 MST + ISR + EEJ	1809	03 Oct 08:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-10-03T05:26:38-05:00	2014-11-21T07:33:01-05:00	"'''03 October 2013'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
08:00 LV OFF
08:15 HV OFF"	vquesada
Milestone 2014_09 MST + ISR + EEJ	1808	03 Oct 06:10 Calibration of TRs and ATRs	ISR		Spark Gaps	AValdez	new	2014-10-03T04:46:56-05:00	2014-10-03T04:46:56-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1807	03 Oct 03:17 Calibration of TRs and ATRs	ISR		Spark Gaps	AValdez	new	2014-10-03T04:46:26-05:00	2014-10-03T04:46:26-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1806	03 Oct 00:23 Calibration of TRs and ATRs	ISR		Spark Gaps	AValdez	new	2014-10-03T04:45:40-05:00	2014-10-03T04:45:40-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1805	02 Oct 21:20 Calibration of TRs and ATRs	ISR		Spark Gaps	AValdez	new	2014-10-03T04:44:43-05:00	2014-10-03T04:44:43-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1804	02 October 23:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-10-02T20:22:23-05:00	2014-10-02T20:22:23-05:00	"'''02 October 2013'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW"	vquesada
Milestone 2014_09 MST + ISR + EEJ	1803	02 Oct. 19:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-10-02T16:28:09-05:00	2014-10-02T16:28:09-05:00	"
02 - 10 - 2014
 08:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4100 VAC, 300 KW
 09:00 TX Power sample (-70 dB coupling)
 Tx1 +3.7 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4100 VAC, 300 KW
 10:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4050 VAC, 300 KW
 11:00 TX Power sample (-70 dB coupling)
 Tx1 +3.6 dBm
 Tx4 +3.6 dBm
 Line voltage and power: 4000 VAC, 290 KW

 11:25 Falla Crowbar H.V. variation in AC line
 11:47 Falla Crowbar H.V. variation in AC line

 12:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4100 VAC, 300 KW
 13:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 14:00 TX Power sample (-70 dB coupling)
 Tx1 +3.6 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4010 VAC, 290 KW
 15:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.6 dBm
 16:00 TX Power sample (-70 dB coupling)
 Tx1 +3.6 dBm
 Tx4 +3.8 dBm
 17:00 TX Power sample (-70 dB coupling)
 Tx1 +3.7 dBm
 Tx4 +4.0 dBm
 18:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
 19:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW








 
 
 
 
"	rtadeo
Milestone 2014_09 MST + ISR + EEJ	1802	02 Oct 18:06 Calibration of TRs and ATRs	ISR		Antennas	A. Coronado	new	2014-10-02T16:14:16-05:00	2014-10-02T16:14:16-05:00	Calibration of TRs and ATRs	pcondor
Milestone 2014_09 MST + ISR + EEJ	1801	02 Oct 17:40 Restart Acquition and processing	ISR		Process/Analysis Program	P. Condor	new	2014-10-02T16:13:15-05:00	2014-10-02T16:13:15-05:00	Restart Acquisition and processing	pcondor
Milestone 2014_09 MST + ISR + EEJ	1800	02 Oct 17:35 Change of Hard disk en JARS	ISR		Acquisition system	P. Condor	new	2014-10-02T16:11:41-05:00	2014-10-02T16:11:41-05:00	Change of Hard disk en JARS to have more space.	pcondor
Milestone 2014_09 MST + ISR + EEJ	1799	02 Oct 15:00 Spark gaps adjusment	ISR		Spark Gaps		new	2014-10-02T13:19:11-05:00	2014-10-02T13:19:11-05:00	Spark gaps adjusment	joscanoa
Milestone 2014_09 MST + ISR + EEJ	1798	02 Oct 12:00 Spark gaps adjusment	ISR		Spark Gaps		new	2014-10-02T09:22:54-05:00	2014-10-02T09:22:54-05:00	Spark gaps adjusment	joscanoa
Milestone 2014_09 MST + ISR + EEJ	1797	02 Oct 11:47 Tx On	ISR		Transmitters		new	2014-10-02T09:11:50-05:00	2014-10-02T09:11:50-05:00	Tx On	joscanoa
Milestone 2014_09 MST + ISR + EEJ	1796	02 Oct 11:35 Fall of TX	ISR		Transmitters		new	2014-10-02T09:08:19-05:00	2014-10-02T09:08:19-05:00	Fall of TX	joscanoa
Milestone 2014_09 MST + ISR + EEJ	1795	02 Oct 11:25 Fall of TX	ISR		Transmitters		new	2014-10-02T08:57:43-05:00	2014-10-02T08:57:43-05:00	Fall of TX	joscanoa
Milestone 2014_09 MST + ISR + EEJ	1794	02 Oct 08:55 Spark gaps adjusment	ISR		Spark Gaps	joscanoa	new	2014-10-02T08:26:44-05:00	2014-10-02T08:27:37-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1793	02 October 07:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-10-02T04:22:56-05:00	2014-10-02T04:22:56-05:00	"'''02 October 2013'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
05:40 Cae fuente de screen PA Tx1.
06:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4040 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4040 VAC, 300 KW"	vquesada
Milestone 2014_09 MST + ISR + EEJ	1792	01 October 23:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-10-01T20:29:20-05:00	2014-10-01T20:29:20-05:00	"'''01 october 2013'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.0 dBm
Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.0 dBm
Line voltage and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4100 VAC, 300 KW
"	vquesada
Milestone 2014_09 MST + ISR + EEJ	1791	1 Oct 19:45 Transmitter power measurements	ISR		Transmitters		new	2014-10-01T17:12:35-05:00	2014-10-01T17:12:35-05:00	"09:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4070 VAC, 290 KW
09:20 Phase adjustment on PA 1.
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4020 VAC, 290 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.6 dBm
Tx4 +3.7 dBm
Line voltage and power: 4000 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +4.0 dBm
Line voltage and power: 4040 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +4.0 dBm
Line voltage and power: 4040 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.0 dBm
Line voltage and power: 4120 VAC, 300 KW
"	ryaya
Milestone 2014_09 MST + ISR + EEJ	1790	01 Oct 18:21 Calibration of ATR and TR	ISR		Antennas	jortiz	new	2014-10-01T15:44:37-05:00	2014-10-01T15:44:37-05:00	Calibration of ATR and TR	jortiz
Milestone 2014_09 MST + ISR + EEJ	1789	01 Oct 17:30 Acquisition system was restarted, hard drive change	ISR		Acquisition system	jortiz	new	2014-10-01T14:54:52-05:00	2014-10-01T15:44:05-05:00	Hard drive was changed with empty one.	jortiz
Milestone 2014_09 MST + ISR + EEJ	1788	01 Oct 14:18 Calibration of ATR and TR	ISR		Antennas	jortiz	new	2014-10-01T11:43:15-05:00	2014-10-01T11:43:15-05:00	Calibration of ATR and TR	jortiz
Milestone 2014_09 MST + ISR + EEJ	1787	01 Oct 10:16 Calibration of ATR and TR	ISR		Antennas	jortiz	new	2014-10-01T11:41:41-05:00	2014-10-01T11:41:41-05:00	Calibration of ATR and TR	jortiz
Milestone 2014_09 MST + ISR + EEJ	1786	01 Oct 09:39 Transmitter Power Adjustments, TX1	ISR		Transmitters	jortiz	new	2014-10-01T07:07:22-05:00	2014-10-01T07:07:22-05:00	Transmitter power and phase were adjusted for TX1	jortiz
Milestone 2014_09 MST + ISR + EEJ	1785	01 Oct 07:30 Transmitter Power Measurements	ISR		Transmitters		new	2014-10-01T04:33:20-05:00	2014-10-01T04:33:20-05:00	"30/09/2014
20:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4000 VAC, 290 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4000 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4000 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
01/10/2014
00:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4100 VAC, 300 KW




"	rtadeo
Milestone 2014_09 MST + ISR + EEJ	1784	01 Oct 06:49 Acquisition and processing programs were restarted	ISR		Acquisition system	I. Manay	new	2014-10-01T04:16:43-05:00	2014-10-01T04:16:43-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1783	01 Oct 06:10 Spark gap adjusment	ISR		Spark Gaps	J. Lavado	new	2014-10-01T03:32:54-05:00	2014-10-01T03:32:54-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1782	01 Oct 03:10 Spark gap adjusment	ISR		Spark Gaps	J. Lavado	new	2014-10-01T00:39:20-05:00	2014-10-01T00:39:20-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1781	01 Oct 02:45 Acquisition and processing programs were restarted	ISR		Acquisition system	I. Manay	new	2014-10-01T00:10:21-05:00	2014-10-01T00:13:56-05:00	Acquisition problems at 01:10, 01:18, 01:39, 01:46, 01:49 and 02:43. Acquisition and processing were restarted.	imanay
Milestone 2014_09 MST + ISR + EEJ	1780	01 Oct 02:23 EEJ plots	ISR		Plot	I. Manay	new	2014-09-30T23:41:27-05:00	2014-09-30T23:41:27-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1779	01 Oct 02:22 ISR plots	ISR		Plot	I. Manay	new	2014-09-30T23:39:52-05:00	2014-09-30T23:39:52-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1778	01 Oct 02:20 MST plots	ISR		Plot	I. Manay	new	2014-09-30T23:36:13-05:00	2014-09-30T23:36:13-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1777	01 Oct 00:10 Spark gap adjusment	ISR		Spark Gaps	J. Lavado	new	2014-09-30T21:45:00-05:00	2014-09-30T21:45:00-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1776	01 Oct 00:01 Acquisition and processing programs were restarted	ISR		Acquisition system	I. Manay	new	2014-09-30T21:44:01-05:00	2014-09-30T21:44:01-05:00	Processing and acquisition programs were stopped at 23:58. They were restarted after 3 minutes with an empty disk drive of 1.81TB.	imanay
Milestone 2014_09 MST + ISR + EEJ	1775	30 Sep 22:51 Acquisition system was restarted	ISR		Acquisition system	I. Manay	new	2014-09-30T20:21:18-05:00	2014-09-30T20:23:49-05:00	JARS system was not able to acquire, so it was restarted manually. Processing programs were also restarted.	imanay
Milestone 2014_09 MST + ISR + EEJ	1774	30 Sep 20:56 Spark gap adjustments	ISR		Spark Gaps	J. Lavado	new	2014-09-30T18:17:43-05:00	2014-09-30T18:17:43-05:00		imanay
Milestone 2014_09 MST + ISR + EEJ	1773	30 Sep 18:00pm  Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-09-30T17:23:19-05:00	2014-09-30T17:23:19-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1772	30 Sep 15:00pm  Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-09-30T17:22:57-05:00	2014-09-30T17:22:57-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1771	30 Sep 12:00pm  Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-09-30T17:22:23-05:00	2014-09-30T17:22:23-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1770	30 Sep 08:50am  Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-09-30T17:21:56-05:00	2014-09-30T17:21:56-05:00		avaldez
Milestone 2014_09 MST + ISR + EEJ	1769	30 Sep 19:45 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-30T17:03:45-05:00	2014-09-30T17:03:45-05:00	"09:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +3.9 dBm
Line voltage and power: 4070 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4030 VAC, 290 KW
10:27 Alarm at PA 1 screen power supply
11:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +3.9 dBm
Line voltage and power: 4060 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +3.9 dBm
Line voltage and power: 4030 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 290 KW
17:00 PA 1 power adjustment
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +4.0 dBm
Line voltage and power: 4020 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +4.1 dBm
Line voltage and power: 4100 VAC, 300 KW"	ryaya
Milestone 2014_09 MST + ISR + EEJ	1768	30 Set 05:20 Calibration of ATR and TR	ISR		Antennas	J. Lavado	new	2014-09-30T04:48:45-05:00	2014-09-30T04:48:45-05:00	Calibration of ATR and TR	pcondor
Milestone 2014_09 MST + ISR + EEJ	1767	30 Sep 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-30T04:24:44-05:00	2014-09-30T04:24:44-05:00	"
29 Sep. 2014
 20:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.95 dBm
 Line voltage and power: 4080 VAC, 300 KW
30 Sep. 2014
00:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4080 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4080 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4080 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4080 VAC, 300 KW






"	rtadeo
Milestone 2014_09 MST + ISR + EEJ	1766	30 Set 01:35 Calibration of ATR and TR	ISR		Antennas	J. Lavado	new	2014-09-29T23:57:43-05:00	2014-09-29T23:57:43-05:00	Calibration of ATR and TR	pcondor
Milestone 2014_09 MST + ISR + EEJ	1765	29 Set 23:59 Figures of spectra and rti	ISR		Process/Analysis Program	P. Condor	new	2014-09-29T23:53:42-05:00	2014-09-29T23:53:42-05:00	Figures of spectra and rti	pcondor
Milestone 2014_09 MST + ISR + EEJ	1764	29 Set 22:20 Calibration of ATR and TR	ISR		Antennas	J. Lavado	new	2014-09-29T23:52:39-05:00	2014-09-29T23:52:39-05:00	Calibration of ATR and TR	pcondor
Milestone 2014_09 MST + ISR + EEJ	1763	29 Sep 19:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-29T16:27:30-05:00	2014-09-29T16:27:30-05:00	"'''29 Septembre 2013'''
13:35 LV  ON
13:55 HV  ON
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.5 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 300 KW
14:05 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4080 VAC, 300 KW
"	vquesada
Milestone 2014_09 MST + ISR + EEJ	1762	29 Set 12:15 Antenna VSWR	ISR		Start experiment	ryanque	new	2014-09-29T09:37:04-05:00	2014-09-29T09:37:04-05:00	"WUp 1.05
WDn 1.07
NDn 1.10
NUp 1.06
EUp 1.03
EDn 1.07
SDn 1.09
SUp 1.04"	ryanque
Milestone 2014_09 MST + ISR + EEJ	1761	29 Set 11:50 Log created	ISR		Start experiment	ryanque	new	2014-09-29T09:29:23-05:00	2014-09-29T09:29:23-05:00	Log created for MST + ISR + EEJ	ryanque
Milestone 2014_09 ISR + Imaging	1760	29 Sep 11:00 Saving data in PUMA	ISR+Imaging		General	I. Manay	new	2014-09-29T08:26:45-05:00	2014-09-29T08:26:45-05:00	"EW_Drift : 143GB, 2003 files
Faraday : 41.3GB, 791 files
Imaging : 259GB, 332 files"	imanay
Milestone 2014_09 ISR + Imaging	1759	27 Set 08:00 End and figures	ISR		End experiment	P. Condor	new	2014-09-27T05:40:38-05:00	2014-09-27T05:40:38-05:00	 End and figures	pcondor
Milestone 2014_09 ISR + Imaging	1758	27 Set 07:20 Calibration of ATR and TR	ISR		Antennas	J. Lavado	new	2014-09-27T05:39:57-05:00	2014-09-27T05:39:57-05:00	 Calibration of ATR and TR	pcondor
Milestone 2014_09 ISR + Imaging	1757	27 Set 07:09 Tx Off	ISR		Transmitters	P. Condor	new	2014-09-27T05:39:20-05:00	2014-09-27T05:39:20-05:00	Tx Off	pcondor
Milestone 2014_09 ISR + Imaging	1756	27 Set 06:56 Tx On	ISR		Transmitters	P. Condor	new	2014-09-27T05:38:40-05:00	2014-09-27T05:38:40-05:00	Tx On	pcondor
Milestone 2014_09 ISR + Imaging	1755	27 Set 06:30 Fall of Tx	ISR		Transmitters	P. Condor	new	2014-09-27T05:37:59-05:00	2014-09-27T05:37:59-05:00	Fall of Tx	pcondor
Milestone 2014_09 ISR + Imaging	1754	27 Sep 07:40 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-27T04:57:20-05:00	2014-09-29T09:32:21-05:00	"'''27 Septembre 2013'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3 dBm
Tx4 +2.2 dBm
D3 -5.8 dBm
Line voltage and power: 4100 VAC, 310 KW
03:18 Driver 3 OFF
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 KW
06:32 Falla relay K12 de control PA Tx4
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 KW
08:00 HV OFF
08:15 LV OFF"	vquesada
Milestone 2014_09 ISR + Imaging	1753	27 Set 03:20 Figures of Imaging	ISR		Process/Analysis Program	P. Condor	new	2014-09-27T03:32:15-05:00	2014-09-27T03:32:15-05:00	 Figures of Imaging	pcondor
Milestone 2014_09 ISR + Imaging	1752	27 Set 04:00 Calibration of ATR and TR	ISR		Antennas	P. Condor	new	2014-09-27T03:28:41-05:00	2014-09-27T03:28:41-05:00	Calibration of ATR and TR	pcondor
Milestone 2014_09 ISR + Imaging	1751	26 Set 23:59 Figures of noise, rtis and others	ISR		Process/Analysis Program	P. Condor	new	2014-09-27T03:21:07-05:00	2014-09-27T03:21:07-05:00	Figures of noise, rtis and others.	pcondor
Milestone 2014_09 ISR + Imaging	1750	27 Set 03:15 Stop Imaging	ISR		Acquisition system	P. Condor	new	2014-09-27T03:19:43-05:00	2014-09-27T03:19:43-05:00	Stop Imaging	pcondor
Milestone 2014_09 ISR + Imaging	1749	26 Set 23:50 Calibration ATR and Tr	ISR		Antennas	J. Lavado	new	2014-09-27T03:18:44-05:00	2014-09-27T03:18:44-05:00	Calibration ATR and TR	pcondor
Milestone 2014_09 ISR + Imaging	1748	26 Sep 23:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-26T20:23:36-05:00	2014-09-29T09:33:36-05:00	"'''26 Septembre 2013'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.2 dBm
Tx4 +1.9 dBm
D3 -5.9 dBm
Line voltage and power: 4060 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.2 dBm
Tx4 +1.9 dBm
D3 -5.9 dBm
Line voltage and power: 4060 VAC, 310 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 310 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
D3 -5.8 dBm
Line voltage and power: 4080 VAC, 310 KW"	vquesada
Milestone 2014_09 ISR + Imaging	1747	26 Sep 19:50 Spark gap adjustments	ISR+Imaging		Spark Gaps	W. Rojas	new	2014-09-26T17:12:07-05:00	2014-09-26T17:12:07-05:00		imanay
Milestone 2014_09 ISR + Imaging	1746	26 Sep 20:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-26T16:27:31-05:00	2014-09-29T09:35:05-05:00	"26 Septembre 2014

08:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1,5.4 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4040 VAC, 310 KW
09:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1,5.4 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4040 VAC, 310 KW
10:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1,5.4 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4040 VAC, 310 KW
11:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1,5.4 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1,5.4 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4040 VAC, 310 KW
13:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1,5.4 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4050 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.2,5.9 dBm
 Tx4 +2.2 dBm
 Line voltage and power: 4040 VAC, 310 KW
15:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.2,5.9 dBm
 Tx4 +2.2 dBm
 Line voltage and power: 4100 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.2,5.7 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4040 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.2,5.7 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4040 VAC, 310 KW
18:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.2,5.7 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4040 VAC, 310 KW
18:15 Drv3 ON  -5.9 dBm
19:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.2,5.7 dBm
 Tx4 +2.1 dBm
 Dr3 -5.9 dBm
 Line voltage and power: 4060 VAC, 300 KW













"	rtadeo
Milestone 2014_09 ISR + Imaging	1745	26 Sep 18:15 Imaging experiment starts	ISR+Imaging		Acquisition system	I. Manay	new	2014-09-26T15:41:51-05:00	2014-09-26T15:41:51-05:00		imanay
Milestone 2014_09 ISR + Imaging	1744	26 Sep 16:08 Spark-gap adjusments	ISR+Imaging		Spark Gaps	W. Rojas	new	2014-09-26T13:36:06-05:00	2014-09-26T14:09:27-05:00		imanay
Milestone 2014_09 ISR + Imaging	1743	26 Sep 14:30 Pass of the moon started at 14:00	ISR+Imaging		Physical Phenomena	I. Manay	new	2014-09-26T12:01:28-05:00	2014-09-26T12:01:28-05:00		imanay
Milestone 2014_09 ISR + Imaging	1742	26 Sep 12:11 Spark gap adjustments	ISR+Imaging		Spark Gaps	W. Rojas	new	2014-09-26T11:16:47-05:00	2014-09-26T11:16:47-05:00		imanay
Milestone 2014_09 ISR + Imaging	1741	26 Sep 08:22 Spark gap adjustments	ISR+Imaging		Spark Gaps	W. Rojas	new	2014-09-26T06:59:16-05:00	2014-09-26T06:59:16-05:00		imanay
Milestone 2014_09 ISR + Imaging	1740	26 Sep 07:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-26T04:19:53-05:00	2014-09-29T09:31:06-05:00	"'''26 Septembre 2013'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4080 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4040 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4040 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4040 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4040 VAC, 310 KW"	vquesada
Milestone 2014_09 ISR + Imaging	1739	25 Set 23:00 Se detiene adquisicion en PC IMAGING	ISR		Acquisition system	DCordova	new	2014-09-26T03:26:38-05:00	2014-09-26T03:26:38-05:00	"Ya no se observa spread-f, se detiene adquisicion en PC IMAGING.
Se apago DDS y CR
Se detuvo, en forma automatica, programa de procesamiento  por falta de datos"	dcordova
Milestone 2014_09 ISR + Imaging	1738	25 Set 21:40 Cae transmisor tx1	ISR		Transmitters	DCordova	new	2014-09-26T03:22:34-05:00	2014-09-26T03:22:34-05:00	Cae fuente de transmisor tx1, se restituye a las 21:41	dcordova
Milestone 2014_09 ISR + Imaging	1737	26 Set 04:35 Calibration of ATrs and TRs	ISR		Spark Gaps	A. Coronado	new	2014-09-26T03:17:26-05:00	2014-09-26T03:17:26-05:00		dcordova
Milestone 2014_09 ISR + Imaging	1736	26 Set 00:35 Calibration of ATrs and TRs	ISR		Spark Gaps	A. Coronado	new	2014-09-26T03:16:52-05:00	2014-09-26T03:16:52-05:00		dcordova
Milestone 2014_09 ISR + Imaging	1735	25 Set 20:30 Calibration of ATrs and TRs	ISR		Spark Gaps	A. Coronado	new	2014-09-26T03:15:59-05:00	2014-09-26T03:18:11-05:00		dcordova
Milestone 2014_09 ISR + Imaging	1734	26 Sep 23:59  Figures of rtis, spectros, etc (EW_DRIFT)	ISR		Process/Analysis Program	DCordova	new	2014-09-25T21:17:13-05:00	2014-09-25T21:17:13-05:00	Se suben imagenes de los experimento EW Drifts y Faraday	dcordova
Milestone 2014_09 ISR + Imaging	1733	25 Sep 23:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-25T20:21:43-05:00	2014-09-29T09:34:15-05:00	"'''25 Septembre 2013'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3dBm
Tx4 +2.0 dBm
D3 -6.1 dBm
Line voltage and power: 4030 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3dBm
Tx4 +2.0 dBm
D3 -6.1 dBm
Line voltage and power: 4000 VAC, 310 KW
21:41 Cae fuente de screen PA Tx1
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.1dBm
Tx4 +2.2 dBm
D3 -5.7 dBm
Line voltage and power: 4090 VAC, 310 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.1 dBm
Tx4 +2.2 dBm
D3 -5.8  dBm
Line voltage and power: 4090 VAC, 310 KW
23:04 Drier 3 OFF"	vquesada
Milestone 2014_09 ISR + Imaging	1732	25 Sep 20:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-25T17:23:49-05:00	2014-09-25T17:23:49-05:00	"25 Septembre 2013

08:00 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.4 dBm , +5.6 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4080 VAC, 310 KW
09:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.2 dBm , +5.7 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4080 VAC, 310 KW
10:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.2 dBm , +5.7 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4050 VAC, 310 KW
11:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm , +5.4 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 310 KW
12:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.0 dBm , +5.4 dBm
 Tx4 +2.0 dBm
13:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.0 dBm , +5.4 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4080 VAC, 310 KW
14:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.0 dBm , +5.4 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.0 dBm , +5.4 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.3 dBm , +5.6 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.3 dBm , +5.6 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 300 KW
17:40 Drv3 -5.8 dBm
18:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.4 dBm 
 Tx4 +2.0 dBm
 Dv3 -5.8 dBm
 Line voltage and power: 4050 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.4 dBm 
 Tx4 +2.0 dBm
 Dv3 -5.9 dBm
 Line voltage and power: 4050 VAC, 300 KW


 




 
"	rtadeo
Milestone 2014_09 ISR + Imaging	1731	25 Set 16:30 Calibration ATRs and TRs	ISR		Antennas	J. Lavado	new	2014-09-25T16:05:58-05:00	2014-09-25T16:05:58-05:00	Calibration ATRs and TRs	pcondor
Milestone 2014_09 ISR + Imaging	1730	25 Set 12:10 Calibration of ATrs and TRs	ISR		Antennas	J. Lavado	new	2014-09-25T16:04:58-05:00	2014-09-25T16:04:58-05:00	Calibration of ATrs and TRs	pcondor
Milestone 2014_09 ISR + Imaging	1729	25 Set 09:10 Restart Faraday	ISR		Acquisition system	P. Condor	new	2014-09-25T16:04:14-05:00	2014-09-25T16:04:14-05:00	Restart Faraday because there is desynchronization.	pcondor
Milestone 2014_09 ISR + Imaging	1728	25 Set 08:10 Restart EW_Drifts	ISR		Acquisition system	P. Condor	new	2014-09-25T16:02:24-05:00	2014-09-25T16:02:24-05:00	Restart EW_Drifts because we restart pc ARES.	pcondor
Milestone 2014_09 ISR + Imaging	1727	24 Set 23:59 Plots of Experiment	ISR+Imaging		Plot	AValdez	new	2014-09-25T04:50:59-05:00	2014-09-25T04:50:59-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1726	25 Set 07:18  Spark Gaps Adjusment	ISR+Imaging		Spark Gaps	AValdez	new	2014-09-25T04:50:02-05:00	2014-09-25T04:50:02-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1725	25 Set 06:06  The Transmitter goes down-EW_DRIFT	ISR+Imaging		Transmitters	AValdez	new	2014-09-25T04:49:10-05:00	2014-09-25T04:49:10-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1724	25 Set 05:53  The Transmitter goes down-EW_DRIFT	ISR+Imaging		Transmitters	AValdez	new	2014-09-25T04:48:18-05:00	2014-09-25T04:48:18-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1723	25 Sep 07:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-25T04:22:04-05:00	2014-09-29T09:31:54-05:00	"
== 25 Septembre 2013 ==

00:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2dBm
Tx4 +2.0 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.2dBm
Tx4 +2.0 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 310 KW
01:10 Driver 3 OFF
01:15 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3,8.8 dBm
Tx4 +2.1 dBm
Line voltage and power: 4080 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4080 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.2,5.6 dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 310 KW
03:40 Vuela fusible de la fuente de +B Driver 4 y fusible de breaker de entrado 220VAC
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4000 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4000 VAC, 310 KW
05:54 Cae fuente de screen PA Tx2
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4000 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.4,5.6 dBm
Tx4 +2.2 dBm
Line voltage and power: 4000 VAC, 310 KW"	vquesada
Milestone 2014_09 ISR + Imaging	1722	25 Set 03:34  The Transmitter goes down-FARADAY	ISR+Imaging		Transmitters	AValdez	new	2014-09-25T02:50:24-05:00	2014-09-25T02:50:24-05:00	Problems with Power Amplifier, this problem was fixed after 10 minutes	avaldez
Milestone 2014_09 ISR + Imaging	1721	25 Set 03:30 Spark gap adjusment	ISR+Imaging		Spark Gaps	AValdez	new	2014-09-25T02:48:43-05:00	2014-09-25T02:48:43-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1720	25 Set 01:05 Turn Off PC-JARS-IMAGING ACQUISITION SYSTEM	ISR+Imaging		Acquisition system	AValdez	new	2014-09-25T02:45:20-05:00	2014-09-25T02:45:20-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1719	24 Set 23:33 Spark gap adjusment	ISR+Imaging		Spark Gaps	AValdez	new	2014-09-25T02:42:13-05:00	2014-09-25T02:42:13-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1718	24 Sep 23:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-24T20:28:29-05:00	2014-09-29T09:30:19-05:00	"'''23 Septembre 2013'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2dBm
Tx4 +2.0 dBm
D3 -5.6 dBm
Line voltage and power: 4030 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2dBm
Tx4 +2.0 dBm
D3 -5.6 dBm
Line voltage and power: 4030 VAC, 310 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.2dBm
Tx4 +2.0 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 310 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.2dBm
Tx4 +2.0 dBm
D3 -5.6 dBm
Line voltage and power: 4080 VAC, 310 KW"	vquesada
Milestone 2014_09 ISR + Imaging	1717	24 Sep 19:20 Transmitter Power measurements	ISR		Transmitters		new	2014-09-24T16:39:33-05:00	2014-09-24T16:39:33-05:00	"08:17 Alarm at PA 1 screen power supply
08:42 Alarm at PA 1 screen power supply
09:15 Alarm at PA 1 screen power supply
10:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.4 dBm/ +5.6 dBm
4 +2.2 dBm
Voltage line and power: 4090 VAC, 305 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.2 dBm/ +5.5 dBm
4 +2.1 dBm
Voltage line and power: 4080 VAC, 305 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4060 VAC, 310 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.1 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4050 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4080 VAC, 305 KW 
15:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4080 VAC, 310 KW 
16:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4080 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.2 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4100 VAC, 300 KW
17:40 Pulse changed
18:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.1 dBm
4 +2.1 dBm
D3 -5.6 dBm
Voltage line and power: 4100 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.4 dBm
4 +2.4 dBm
D3 -5.5 dBm
Voltage line and power: 4100 VAC, 300 KW"	ryaya
Milestone 2014_09 ISR + Imaging	1716	23 Sep 07:00 Transmitter Power measurements	ISR		Transmitters		new	2014-09-24T05:38:05-05:00	2014-09-24T05:38:05-05:00	"
23 sep.2014
20:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.3 dBm
 4 +2.1 dBm
Dr3-5.5 dBm 
 Voltage line and power: 4100 VAC, 305 KW 
21:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.3 dBm
 4 +2.1 dBm
Dr3-5.5 dBm 
 Voltage line and power: 4100 VAC, 305 KW 
22:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.5 dBm
 4 +2.1 dBm
Dr3-5.5 dBm 
 23:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.5 dBm
 4 +2.1 dBm
Dr3-5.5 dBm 
24-Set.-2014

00:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.5 dBm
 4 +2.1 dBm
Dr3-5.5 dBm 
01:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.5 dBm
 4 +2.1 dBm
Dr3-5.5 dBm 
 02:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.4 dBm , 5.6dBm
 4 +2.0 dBm
Dv3:off
 03:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.4 dBm , 5.6dBm
 4 +2.0 dBm
Dv3:off
 04:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.4 dBm , 5.6dBm
 4 +2.0 dBm
Dv3:off
 05:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.4 dBm , 5.6dBm
 4 +2.0 dBm
Dv3:off
 06:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.4 dBm , 5.6dBm
 4 +2.0 dBm
Dv3:off
 07:00 Falla de PA1.

 
 
 













20:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +2.2 dBm/ +5.6 dBm
 4 +1.9 dBm
 Voltage line and power: 4070 VAC, 305 KW 
 
"	rtadeo
Milestone 2014_09 ISR + Imaging	1715	24 Sep 07:55 Drop at reception lines of ew_drift and faraday experiments	ISR+Imaging		Reception	I. Manay	new	2014-09-24T05:19:47-05:00	2014-09-24T05:19:47-05:00	Drop in reception lines due to a fail at the transmisor.	imanay
Milestone 2014_09 ISR + Imaging	1714	24 Sep 04:30 1dB attenuation to the ew_drift channel A	ISR+Imaging		Reception	I. Manay	new	2014-09-24T02:02:02-05:00	2014-09-24T02:03:14-05:00	Due to sudden increase of noise at the A channel of the ew_drift, it was attenuated 1dB. This increase had a thirty minutes duration.	imanay
Milestone 2014_09 ISR + Imaging	1713	24 Sep 04:12 Spark gap adjusment	ISR+Imaging		Spark Gaps	A. Belleza	new	2014-09-24T01:57:54-05:00	2014-09-24T01:57:54-05:00		imanay
Milestone 2014_09 ISR + Imaging	1712	24 Sep 01:28 Spark gap adjustments	ISR+Imaging		Spark Gaps	A. Belleza	new	2014-09-23T22:47:56-05:00	2014-09-23T22:47:56-05:00		imanay
Milestone 2014_09 ISR + Imaging	1711	23 Sep 23:59 ew_drift, faraday and imaging plots	ISR+Imaging		Plot	I. Manay	new	2014-09-23T21:19:25-05:00	2014-09-23T21:19:25-05:00		imanay
Milestone 2014_09 ISR + Imaging	1710	23 Sep 20:10 Spark gap adjustments	ISR+Imaging		Spark Gaps	I. Manay	new	2014-09-23T18:06:43-05:00	2014-09-23T18:06:43-05:00		imanay
Milestone 2014_09 ISR + Imaging	1709	23 Sep 19:50 Transmitter Power measurements	ISR		Transmitters		new	2014-09-23T17:15:05-05:00	2014-09-23T17:15:05-05:00	"9:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.2 dBm/ +5.6 dBm
4 +1.9 dBm
Voltage line and power: 4070 VAC, 305 KW 
10:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.3 dBm/ +5.6 dBm
4 +2.0 dBm
Voltage line and power: 4000 VAC, 305 KW 
10:56 Alarm detected at Screen power supply PA 1
11:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.3 dBm/ +5.8 dBm
4 +2.2 dBm
Voltage line and power: 4020 VAC, 310 KW
12:00 Alarm detected at Screen power supply PA 2
12:05 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +2.4 dBm/ +5.6 dBm
4 +2.0 dBm
Voltage line and power: 4080 VAC, 315 KW
13:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.0 dBm/ +5.4 dBm
4 +1.8 dBm
Voltage line and power: 4000 VAC, 300 KW
13:40 Alarm detected at screen power supply PA 2
14:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +2.1 dBm/ +5.2 dBm
4 +1.8 dBm
Voltage line and power: 4020 VAC, 305 KW 
15:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.2 dBm/ +5.3 dBm
4 +2.0 dBm
Voltage line and power: 4030 VAC, 305 KW 
16:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +2.2 dBm/ +5.2 dBm
4 +2.0 dBm
Voltage line and power: 4080 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.4 dBm/ +5.6 dBm
4 +2.1 dBm
Voltage line and power: 4080 VAC, 310 KW

18:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +2.3 dBm
4 +2.0 dBm
D3 -5.4 dBm
Voltage line and power: 4030 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +2.4 dBm
4 +2.1 dBm
D3 -5.5 dBm
Voltage line and power: 4100 VAC, 305 KW"	ryaya
Milestone 2014_09 ISR + Imaging	1708	23 Sep 07:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-09-23T04:58:55-05:00	2014-09-24T07:55:01-05:00	"22 September 2014
 20:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.4 dBm
 Tx4 +2.2 dBm
 Dr3 -5.9 dBm
 Line voltage and power: 4100 VAC, 320 KW
 21:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.5 dBm
 Tx4 +1.9 dBm
 Dr3 -5.9 dBm
 22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +2.2 dBm
 Tx4 +1.8 dBm
 Dr3 -6.0 dBm
 Line voltage and power: 4050 VAC, 310 KW
 23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.4 dBm
 Tx4 +2.1 dBm
 Dr3 -6.0 dBm
23 September 2014
00:00 TX Power sample (-70 dB coupling)
 Tx1 +5.9 dBm
 Tx2 +2.4 dBm
 Tx4 +2.1 dBm
 Dr3 -5.9 dBm
 Line voltage and power: 4100 VAC, 320 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.4 dBm
 Tx4 +2.1 dBm
 Dr3 -5.9 dBm
02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.4 dBm
 Tx4 +2.1 dBm
 Dr3 -5.9 dBm
03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.2 dBm ,+5.5 dBm
 Tx4 +2.0 dBm
 Dr3 off
04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.3 dBm ,+5.5 dBm
 Tx4 +2.0 dBm
 Dr3 off
05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.4 dBm ,+5.6 dBm
 Tx4 +1.8 dBm
 Dr3 off
 Line voltage and power: 4050 VAC, 320 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.4 dBm ,+5.6 dBm
 Tx4 +2.0 dBm
 Dr3 off
 Line voltage and power: 4070 VAC, 300 KW
06:50 Falla de Screen PA1, por variacion en las lineas VAC
07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.4 dBm ,+5.6 dBm
 Tx4 +2.0 dBm
 Dr3 off
 Line voltage and power: 4100 VAC, 320 KW


















 "	rtadeo
Milestone 2014_09 ISR + Imaging	1707	22 Set 23:59 Figures of rtis, spectra and others	ISR		Process/Analysis Program	P. Condor	new	2014-09-23T04:36:40-05:00	2014-09-23T04:36:40-05:00	 Figures of rtis, spectra and others of 22-09-2014.	pcondor
Milestone 2014_09 ISR + Imaging	1706	23 Set 06:50 Transmitter off	ISR		Transmitters	P. Condor	new	2014-09-23T04:34:44-05:00	2014-09-23T04:34:44-05:00	"Transmitter off for a moment.
"	pcondor
Milestone 2014_09 ISR + Imaging	1705	23 Set 05:14 Fix ATRs	ISR		Antennas	A. Belleza	new	2014-09-23T04:33:49-05:00	2014-09-23T04:33:49-05:00	Fix Atrs	pcondor
Milestone 2014_09 ISR + Imaging	1704	23 Set 04:50 EW_Drifts Ch C and faraday Noise ch B are ok	ISR		Acquisition system	P. Condor	new	2014-09-23T04:33:06-05:00	2014-09-23T04:33:06-05:00	EW_Drifts Ch C and Faraday Noise ch B are ok after of check cables at the panel..???	pcondor
Milestone 2014_09 ISR + Imaging	1703	22 Set 23:54 Fix ATRs	ISR		Antennas	A. Belleza	new	2014-09-23T04:29:44-05:00	2014-09-23T04:29:44-05:00	 Fix ATRs	pcondor
Milestone 2014_09 ISR + Imaging	1702	22 Set 20:28 Transmitter off	ISR		Transmitters	P. Condor	new	2014-09-23T04:25:41-05:00	2014-09-23T04:25:41-05:00	Transmitter off	pcondor
Milestone 2014_09 ISR + Imaging	1701	22 Set 20:23 Imaging is  OK	ISR		Antennas	P. Condor	new	2014-09-23T04:22:30-05:00	2014-09-23T04:22:30-05:00	Imaging is OK after of connect Driver that is not connected.	pcondor
Milestone 2014_09 ISR + Imaging	1699	22 Set 16:45 Ew_Drift + Faraday Experiments Start	ISR+Imaging		Start experiment	AValdez	new	2014-09-22T14:54:09-05:00	2014-09-22T14:54:09-05:00		avaldez
Milestone 2014_09 ISR + Imaging	1698	22 Sep 17:10 Antena VSWR	ISR		Antennas		new	2014-09-11T14:25:38-05:00	2014-09-24T07:56:37-05:00	"WUP 1.06
WDW 1.04
NDW 1.06
NUP 1.09
EUP 1.04
EDW 1.07
SDW 1.06
SUP 1.06"	ryanque
Milestone 2014_09 ISR + Imaging	1697	11 Sep 14:31 Log created	ISR		Start experiment	ryanque	new	2014-09-11T11:44:47-05:00	2014-09-11T11:44:47-05:00	The log for the ISR + Imaging campaign has been created	ryanque
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1696	27 Aug 09:00 End snd Figures	ISR		End experiment	P. Condor	new	2014-08-27T06:45:36-05:00	2014-08-27T06:45:36-05:00	End of campaign and figures of rti, spectras and noises.	pcondor
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1695	27 Aug 09:20 Data were uploaded to PUMA	ISR		General	imanay	new	2014-08-27T06:33:13-05:00	2014-08-27T06:33:13-05:00	"1) Faraday
Files : 119
Size : 6.2 GB

2) EW_Drift
Files : 303
Size : 21.6 GB"	imanay
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1694	27 August 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-08-27T04:17:25-05:00	2014-08-27T04:17:25-05:00	"'''26 August 2014'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.0, 5.1 dBm
Tx4 +1.9 dBm
Line voltage and power: 4090 VAC, 295 KW
20:07 Crowbar by voltage drop.
20:30 PA power supply falls screen Tx2
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm
Tx4 +1.5 dBm
Line voltage and power: 4090 VAC, 295 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm
Tx4 +1.5 dBm
Line voltage and power: 4090 VAC, 295 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm
Tx4 +1.5 dBm
Line voltage and power: 4090 VAC, 295 KW
'''27 August 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.8, 5.2 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.8, 5.2 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.8, 5.2 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +2.8, 5.2 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 295 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.2 dBm
Tx2 +1.8, 5.1 dBm  
Tx4 +1.6 dBm
Line voltage and power: 4090 VAC, 300 KW"	vquesada
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1693	26 Aug 23:59 Figures of Experiment	ISR		Plot	AValdez	new	2014-08-27T02:00:35-05:00	2014-08-27T02:00:35-05:00		Avaldez
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1692	27 Aug 02:08 Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-08-27T01:59:00-05:00	2014-08-27T01:59:00-05:00		Avaldez
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1691	26 Aug 22:47 Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-08-27T01:57:45-05:00	2014-08-27T01:57:45-05:00		Avaldez
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1690	26 Aug 20:28   The Transmitter goes down	ISR		Transmitters	AValdez	new	2014-08-27T01:56:22-05:00	2014-08-27T01:56:22-05:00	Problems with Power Amplifier, this problem was fixed after 1 minutes	Avaldez
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1689	26 Aug 20:05   The Transmitter goes down	ISR		Transmitters	AValdez	new	2014-08-27T01:54:48-05:00	2014-08-27T01:56:42-05:00	Problems with Power Amplifier, this problem was fixed after 1 minutes	Avaldez
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1688	26 Ago 08:00 Transmitter Power mesearuments	ISR		Transmitters		new	2014-08-26T17:10:26-05:00	2014-08-26T17:10:26-05:00	"26/08/2014
hora     tx     fill      Pot.(inc)
16:00    1      16.5      +5.3dbm
         2      16.5      +2.0dbm / +5.1dbm
         4      16.5      +1.9dbm
17:00    1      16.5      +5.5dbm
         2      16.5      +2.1dbm / +5.2dbm
         4      16.5      +2.0dbm
18:00    1      16.5      +5.5dbm
         2      16.5      +2.0dbm / +5.1dbm
         4      16.5      +1.9dbm
19:00    1      16.5      +5.5dbm
         2      16.5      +2.0dbm / +5.1dbm
         4      16.5      +1.9dbm"	rtadeo
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1687	26 Aug 19:20 Spark gaps adjusment	ISR		Spark Gaps	imanay	new	2014-08-26T16:35:50-05:00	2014-08-26T16:35:50-05:00		imanay
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1686	26 Aug 18:00 vipir system was turned off	ISR		Reception	imanay	new	2014-08-26T15:39:54-05:00	2014-08-26T15:39:54-05:00		imanay
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1685	26 Aug 16:20 Ew_drift + Faraday experiment starts	ISR		Start experiment	imanay	new	2014-08-26T15:30:44-05:00	2014-08-26T15:30:44-05:00	"Ew_drift attenuations:
---------------------
A : 0
B : 1
C : 0
D : 0

Faraday attenuations:
---------------------
E : 8
F : 8"	imanay
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1684	26 Aug 12:23 Antena VSWR	ISR		Antennas		new	2014-08-26T09:36:36-05:00	2014-08-26T09:36:36-05:00	"SUP 1.02
SDN 1.04
EDN 1.01
EUP 1.10
NUP 1.08
NDN 1.10
WDN 1.03
WUP 1.04"	ryanque
Milestone 2014_08_1 EWDrift + Faraday AMISR School	1683	26 Aug 10:48 Log created	ISR		Start experiment		new	2014-08-26T08:01:04-05:00	2014-08-26T08:01:04-05:00		ryanque
Milestone 2014_08 Meteors Aug 05	1681	05 Ago 08:20 Transmitter is turned off	ISR		Transmitters	P. Condor	new	2014-08-06T13:44:49-05:00	2014-08-06T13:44:49-05:00	Transmitter is turned off to check antennas.	pcondor
Milestone 2014_08 Meteors Aug 05	1680	05 Aug 12:30 Transmitter Power Measurements	ISR		Transmitters		new	2014-08-06T13:34:26-05:00	2014-08-06T13:34:26-05:00	"04 Aug 

16:15 Low voltage ON
16:30 HV ON
17:43 TX   Power sample (-70 dB)
       2    -2.0 dBm
       4    -2.1 dBm
19:40 TX   Power sample (-70 dB)
       2    -2.0 dBm
       4    -2.1 dBm
20:00 TX   Power sample (-70 dB)
       2    -2.0 dBm
       4    -2.0 dBm
21:00 TX   Power sample (-70 dB)   Line voltage 4110 VAC 
       2    -2.0 dBm
       4    -2.0 dBm
22:00 TX   Power sample (-70 dB)
       2    -2.0 dBm
       4    -2.0 dBm
23:00 TX   Power sample (-70 dB)
       2    -2.0 dBm
       4    -2.0 dBm

05 Aug 

00:00 TX   Power sample (-70 dB)  Line voltage 4110 VAC
       2    -2.0 dBm
       4    -2.0 dBm
01:00 TX   Power sample (-70 dB)
       2    -2.2 dBm
       4    -2.2 dBm
02:00 TX   Power sample (-70 dB)  Line voltage 4110 VAC
       2    -1.9 dBm
       4    -1.9 dBm
03:00 TX   Power sample (-70 dB)
       2    -1.9 dBm
       4    -1.9 dBm
04:00 TX   Power sample (-70 dB)
       2    -1.9 dBm
       4    -1.9 dBm
05:00 TX   Power sample (-70 dB)  Line voltage 4110 VAC
       2    -1.9 dBm
       4    -1.9 dBm
06:00 TX   Power sample (-70 dB)
       2    -1.9 dBm
       4    -1.9 dBm
07:00 TX   Power sample (-70 dB)
       2    -2.0 dBm
       4    -2.0 dBm
08:20 HV OFF
10:00 HV ON
10:05 TX   Power sample (-70 dB)
       2    -2.2 dBm
       4    -2.2 dBm
11:10 TX   Power sample (-70 dB)
       2    -2.2 dBm
       4    -2.2 dBm
12:25 HV OFF"	ryaya
Milestone 2014_08 Meteors Aug 05	1679	05 Ago 12:20 Figures rti and spectra	ISR		Process/Analysis Program	P. Condor	new	2014-08-05T15:50:43-05:00	2014-08-05T15:50:43-05:00	Figures rti and spectra.	pcondor
Milestone 2014_08 Meteors Aug 05	1678	05 Ago 12:25 End	ISR		End experiment	P. Condor	new	2014-08-05T15:20:02-05:00	2014-08-05T15:20:02-05:00	End experiment.	pcondor
Milestone 2014_08 Meteors Aug 05	1677	05 Ago 10:02 Transmitter turn on	ISR		Transmitters	P. Condor	new	2014-08-05T15:17:56-05:00	2014-08-05T15:17:56-05:00	Transmitter turn on.	pcondor
Milestone 2014_08 Meteors Aug 05	1676	05 Ago 09:54 Pre Amplifier of ch E is changed	ISR		Acquisition system	P. Condor	new	2014-08-05T14:50:26-05:00	2014-08-13T08:32:37-05:00	"Pre Amplifier of ch E is changed. 
Attenuation of chs:
Ch A = 0       Ch E = 0
Ch B = 0       Ch F = 3
Ch C = 0       Ch G = 0
Ch D = 2 db."	pcondor
Milestone 2014_08 Meteors Aug 05	1675	05 Ago 07:30 Ch E noise is low	ISR		Antennas	P.Condor	new	2014-08-05T14:45:33-05:00	2014-08-05T14:45:33-05:00	"Ch E noise is low.  15.23 db.
Tx is turn off for revision of ch D, E and F.
"	pcondor
Milestone 2014_08 Meteors Aug 05	1674	04 Ago 20:24 Beacon is connected	ISR		Acquisition system	P.Condor	new	2014-08-05T14:33:23-05:00	2014-08-05T14:33:23-05:00	Beacon is connected. All OK.	pcondor
Milestone 2014_08 Meteors Aug 05	1673	04 Ago 20:20 TR Ch A is changed	ISR		Reception	P.Condor	new	2014-08-05T14:24:31-05:00	2014-08-05T14:24:31-05:00	TR Ch A is changed.	pcondor
Milestone 2014_08 Meteors Aug 05	1672	04 Ago 19:36 Tx turn on	ISR		Transmitters	P. Condor	new	2014-08-05T14:21:16-05:00	2014-08-05T14:21:16-05:00	Tx turn on.	pcondor
Milestone 2014_08 Meteors Aug 05	1671	04 Ago 19:34 Noise channels after revision channels D,E, and F	ISR		Acquisition system	P.Condor	new	2014-08-05T14:17:56-05:00	2014-08-05T14:17:56-05:00	"Noise channels after revision channels D,E, and F without transmitter. We found a bad cable.
A: 18.03  D: 26.03  G: 21.86
B: 22.63  E: 24.62
C: 17.14  F: 25.90"	pcondor
Milestone 2014_08 Meteors Aug 05	1670	04 Ago 18:36 Revision of Channels D,E,F	ISR		Antennas	P. Condor	new	2014-08-05T13:50:46-05:00	2014-08-05T13:50:46-05:00	Revision of Channels D,E,F. Transmitter is turned off.	pcondor
Milestone 2014_08 Meteors Aug 05	1669	04 Ago 18:08 We started recording data	ISR		Start experiment	P. Condor	new	2014-08-05T13:43:52-05:00	2014-08-05T13:43:52-05:00	"We started recording data.
Before we changed pre amplifier of channel F. Also fix pulses."	pcondor
Milestone 2014_08 Meteors Aug 05	1668	04 Ago 17:30 VSWR Antena	ISR		Start experiment		new	2014-08-04T20:40:10-05:00	2014-08-04T20:40:10-05:00	"VSWR
WUp 1.04
WDn 1.06
EUp 1.07
EDn 1.01
SDn 1.05
SUp 1.03"	ryanque
Milestone 2014_08 Meteors Aug 05	1667	05 August 07:08 Transmitter Power Measurements	ISR	JRO Staff	Transmitters		new	2014-08-04T11:20:29-05:00	2014-08-04T11:20:29-05:00	"'''04 August  2014'''
20:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW
21:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW
22:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW
23:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW
'''05 August  2014'''
00:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW
01:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW
01:40 Cae fuente de screen PA Tx2
02:00 TX Power sample (-70 dB coupling)
Tx2 -1.9 dBm
Tx4 -1.9 dBm
Line voltage and power: 4110 VAC, 260 KW
03:00 TX Power sample (-70 dB coupling)
Tx2 -1.9 dBm
Tx4 -1.9 dBm
Line voltage and power: 4110 VAC, 260 KW
04:00 TX Power sample (-70 dB coupling)
Tx2 -1.9 dBm
Tx4 -1.9 dBm
Line voltage and power: 4110 VAC, 260 KW
05:00 TX Power sample (-70 dB coupling)
Tx2 -1.9 dBm
Tx4 -1.9 dBm
Line voltage and power: 4110 VAC, 260 KW
06:00 TX Power sample (-70 dB coupling)
Tx2 -1.9 dBm
Tx4 -1.9 dBm
Line voltage and power: 4110 VAC, 260 KW
07:00 TX Power sample (-70 dB coupling)
Tx2 -2.0 dBm
Tx4 -2.0 dBm
Line voltage and power: 4110 VAC, 260 KW












"	vquesada
Milestone 2014_08 Meteors Aug 05	1666	05 Ago 04:51  Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-08-04T09:08:48-05:00	2014-08-04T09:08:48-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1665	05 Ago 01:40  The Transmitter goes down	ISR		Transmitters	AValdez	new	2014-08-04T09:06:46-05:00	2014-08-04T09:06:46-05:00	Problems with Power Amplifier, this problem was fixed after 5 minutes	avaldez
Milestone 2014_08 Meteors Aug 05	1664	05 Ago 00:30    Restart acquisition system	ISR		Acquisition system	AValdez	new	2014-08-04T09:01:44-05:00	2014-08-04T09:01:44-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1663	05 Ago 00:09    Restart acquisition system	ISR		Acquisition system	AValdez	new	2014-08-04T08:59:48-05:00	2014-08-04T08:59:48-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1662	05 Ago 00:02    Restart acquisition system	ISR		Acquisition system	AValdez	new	2014-08-04T08:58:47-05:00	2014-08-04T08:58:47-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1661	04 Ago 23:59 Figure of Experiment Meteor	ISR		Process/Analysis Program	AValdez	new	2014-08-04T08:53:40-05:00	2014-08-04T08:56:37-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1660	04 Ago 23:56   Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-08-04T08:52:13-05:00	2014-08-04T08:52:13-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1659	04 Ago 20:25 Noise level	ISR		Acquisition system	AValdez	new	2014-08-04T01:53:06-05:00	2014-08-13T08:28:30-05:00	"Ch1 A = 24.18 dB
Ch2 A = 26.12 dB
Ch3 A = 23.8 dB
Ch4 A = 27.78 dB
Ch5 A = 26.3 dB
Ch6 A = 27.38 dB
Ch7 A = 23.06 dB
"	avaldez
Milestone 2014_08 Meteors Aug 05	1658	04 Ago 20:24 START EXPERIMENT WITH BEACON CONNECTED	ISR		Start experiment	AValdez	new	2014-08-04T01:34:22-05:00	2014-08-04T01:34:48-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1657	04 Ago 20:20  Change TR of Channel A	ISR		Transmitters	AValdez	new	2014-08-04T01:26:08-05:00	2014-08-04T01:26:08-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1656	04 Ago 19:36  Turn On Transmitter	ISR		Transmitters	AValdez	new	2014-08-04T01:23:05-05:00	2014-08-04T02:07:34-05:00		avaldez
Milestone 2014_08 Meteors Aug 05	1655	04 Ago 11:50 August 2014 Meteor Log created	ISR		Start experiment	ryanque	new	2014-08-03T16:06:07-05:00	2014-08-03T16:06:07-05:00	The log has been created.	ryanque
Milestone 2014_07 ISR Summer School	1682	11 Aug 16:30 ISR data was uploaded to PUMA	ISR		General		new	2014-08-11T13:41:45-05:00	2014-08-11T13:48:28-05:00	"1) EW_Drift:
     25.2GB, 354 files
2) Faraday:
     7.26GB, 138 files"	imanay
Milestone 2014_07 ISR Summer School	1654	23 Jul 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-07-22T11:12:42-05:00	2014-07-22T11:12:42-05:00	"'''22 July 2014'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.6,5.7 dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +1.7,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4080 VAC, 310 Kw
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +1.7,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4080 VAC, 310 Kw
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.8,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
'''23 July 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.8,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.8,5.8 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.8,5.8 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.8,5.8 dBm     
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw



"	vquesada
Milestone 2014_07 ISR Summer School	1653	23 Jul 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-07-22T11:11:58-05:00	2014-07-22T11:11:58-05:00	"'''22 July 2014'''
20:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.6,5.7 dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +1.7,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4080 VAC, 310 Kw
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +1.7,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4080 VAC, 310 Kw
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.8,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
'''23 July 2014'''
00:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.8,5.6 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.8,5.8 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.8,5.8 dBm
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.9,5.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4100 VAC, 310 Kw
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.8,5.8 dBm     
Tx4 +2.1 dBm
Line voltage and power: 4100 VAC, 310 Kw



"	vquesada
Milestone 2014_07 ISR Summer School	1652	22 Jul 23:59  Figures of rtis, spectros, etc (EW_DRIFT)	ISR		Process/Analysis Program		new	2014-07-22T04:50:45-05:00	2014-07-22T05:00:21-05:00		Avaldez
Milestone 2014_07 ISR Summer School	1651	22 Jul 22:53 Spark gaps adjusment	ISR		Spark Gaps	AValdez	new	2014-07-22T04:41:29-05:00	2014-07-22T04:41:29-05:00		Avaldez
Milestone 2014_07 ISR Summer School	1650	22 Jul 19:06 Spark gaps adjusment	ISR		Spark Gaps	wrojas	new	2014-07-22T00:07:07-05:00	2014-07-22T00:07:07-05:00		imanay
Milestone 2014_07 ISR Summer School	1648	22 Jul 16:00 Spark gaps adjusment	ISR		Spark Gaps		new	2014-07-21T20:22:34-05:00	2014-07-21T20:30:12-05:00		imanay
Milestone 2014_07 ISR Summer School	1647	22 Jul 13:00 EW_Drift + Faraday starts	ISR		Start experiment	imanay	new	2014-07-21T18:32:14-05:00	2014-07-21T18:32:14-05:00	"The attenuations of the reception lines are fixed to:

EW_Drift:
CHA : 2
CHB : 1
CHC : 0
CHD : 1

Faraday:
CHE : 8
CHF : 8"	imanay
Milestone 2014_07 ISR Summer School	1646	21 Jul 16:27 Antena VSWR	ISR		Start experiment		new	2014-07-20T20:38:22-05:00	2014-07-20T20:38:22-05:00	"WUP 1.10 Centered 1.06 49.986
WDN 1.06
NDN 1.10 Centered 1.02 50.036
NUP 1.10 Centered 1.02 50.080
EUP 1.05
EDN 1.07
SDN 1.06
SUP 1.03"	ryanque
Milestone 2014_07 ISR Summer School	1645	21 Jul 04:20 Log created for ISR School	ISR		Start experiment		new	2014-07-20T20:27:58-05:00	2014-07-20T20:27:58-05:00	The log has been created.	ryanque
Milestone 2014_05_1 MST-ISR	1644	16 May 18:59 Figures of MST	ISR		Process/Analysis Program	P. Condor	new	2014-05-16T15:58:20-05:00	2014-05-16T15:58:20-05:00	Figures of MST	pcondor
Milestone 2014_05_1 MST-ISR	1643	16 May 18:45 Figures of rtis and spectros	ISR		Process/Analysis Program	P. Condor	new	2014-05-16T15:45:54-05:00	2014-05-16T15:45:54-05:00	 Figures of rtis and spectros	pcondor
Milestone 2014_05_1 MST-ISR	1642	16 May 18:24 Transmitter turned on to testing	ISR		Transmitters	P. Condor	new	2014-05-16T15:39:28-05:00	2014-05-16T15:39:28-05:00	Transmitter turned on to testing and see If there are interference.	pcondor
Milestone 2014_05_1 MST-ISR	1641	16 May 18:40 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-16T15:37:37-05:00	2014-05-16T15:37:37-05:00	"11:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +4.1 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +4.1 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 300 KW

18:00  HV  OFF
18:15  LV  OFF"	vquesada
Milestone 2014_05_1 MST-ISR	1640	16 May 18:00 End of experiment	ISR		End experiment	P. Condor	new	2014-05-16T15:30:33-05:00	2014-05-16T15:30:33-05:00	End of experiment	pcondor
Milestone 2014_05_1 MST-ISR	1639	16 May 14:36 Calibration of TRs and ATRs	ISR		Antennas	A. Coronado	new	2014-05-16T13:50:20-05:00	2014-05-16T13:50:20-05:00	Calibration of TRs and ATRs.	pcondor
Milestone 2014_05_1 MST-ISR	1638	16 May 11:00 Rommel is remplaced by Victor	ISR		Transmitters	P. Condor	new	2014-05-16T13:49:25-05:00	2014-05-16T13:49:25-05:00	Rommel Y. is remplaced by Victor Q. in Transmitter.	pcondor
Milestone 2014_05_1 MST-ISR	1637	16 May 10:32 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-05-16T13:43:26-05:00	2014-05-16T13:43:26-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_05_1 MST-ISR	1636	16 May 09:40 Transmitter ON	ISR		Transmitters	P. Condor	new	2014-05-16T13:42:31-05:00	2014-05-16T13:42:31-05:00	Transmitter ON. Record data.	pcondor
Milestone 2014_05_1 MST-ISR	1635	16 May 09:00 Problem in Transmitter	ISR		Transmitters	P. Condor	new	2014-05-16T13:41:00-05:00	2014-05-16T13:41:00-05:00	Problem in Transmitter. shutdowm for a moment.	pcondor
Milestone 2014_05_1 MST-ISR	1634	16 May 07:00 Transmitter Power mesearuments	ISR		Transmitters		new	2014-05-16T04:17:59-05:00	2014-05-16T04:17:59-05:00	"15/05/2014
20:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4040 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4040 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4040 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4020 VAC, 290 KW
16/05/2014
00:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4020 VAC, 290 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4020 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4020 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4020 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
"	rtadeo
Milestone 2014_05_1 MST-ISR	1633	16 May 07:03 Spark gap calibration	ISR		Spark Gaps	jverastegui	new	2014-05-16T04:14:52-05:00	2014-05-16T04:14:52-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1632	16 May 07:00 Signal chain pc plot reactivation	ISR		Plot	jverastegui	new	2014-05-16T04:13:36-05:00	2014-05-16T04:13:36-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1631	16 May 05:10 Plots down on signal chain PC	ISR		Plot	jverastegui	new	2014-05-16T02:52:42-05:00	2014-05-16T02:52:42-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1630	16 May 05:09 Plots restored on signal chain PC	ISR		Plot	jverastegui	new	2014-05-16T02:49:27-05:00	2014-05-16T02:49:27-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1629	16 May 04:07 Plots restored	ISR		Plot	jverastegui	new	2014-05-16T02:40:39-05:00	2014-05-16T02:40:39-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1628	16 May 04:04 Spark gap calibration	ISR		Spark Gaps	jverastegui	new	2014-05-16T02:38:39-05:00	2014-05-16T02:38:39-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1627	16 May 03:55 Restart acquisition system	ISR		Acquisition system	jverastegui	new	2014-05-16T02:36:37-05:00	2014-05-16T02:36:37-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1626	16 May 03:10 Restart Plots	ISR		Plot	jverastegui	new	2014-05-16T02:26:38-05:00	2014-05-16T02:26:38-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1625	16 May 01:02 Spark gap calibration	ISR		Spark Gaps	jverastegui	new	2014-05-16T02:23:58-05:00	2014-05-16T02:23:58-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1624	15 May 23:59 Specter figures	ISR		Plot	jverastegui	new	2014-05-16T01:48:27-05:00	2014-05-16T01:48:27-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1623	15 May 22:00 Spark gap calibration	ISR		Spark Gaps	jverastegui	new	2014-05-16T01:34:38-05:00	2014-05-16T01:34:38-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1622	15 Mayo 19:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-15T17:07:09-05:00	2014-05-15T17:07:09-05:00	"09:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 4010 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.2 dBm
Line voltage and power: 4060 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 +4.1 dBm
Tx4 +4.1 dBm
Line voltage and power: 4040 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.2 dBm
Line voltage and power: 4080 VAC, 300 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 +4.1 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.1 dBm
Line voltage and power: 4040 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4020 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +4.1 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +4.1 dBm
Tx4 +4.1 dBm
Line voltage and power: 4060 VAC, 300 KW
17:55 RF OFF
18:30 RF ON
19:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4040 VAC, 300 KW"	ryaya
Milestone 2014_05_1 MST-ISR	1621	15 May 19:47 Restart Plots	ISR		Acquisition system	ryanque	new	2014-05-15T16:58:45-05:00	2014-05-15T16:58:45-05:00	All plots are restarted due to a delay in the display	avaldez
Milestone 2014_05_1 MST-ISR	1620	15 May 18:40 Spark gap calibration	ISR		Start experiment	ryanque	new	2014-05-15T16:57:26-05:00	2014-05-15T16:57:26-05:00	ATR & TR calibration	avaldez
Milestone 2014_05_1 MST-ISR	1619	15 May 17:50 Shutdown acquisition system	ISR		Acquisition system	ryanque	new	2014-05-15T16:56:31-05:00	2014-05-15T16:56:31-05:00	Due to a hard disk change the acquisition system has been shut down for 20 minutes	avaldez
Milestone 2014_05_1 MST-ISR	1618	15 May 16:40 Slight interfence	ISR		Start experiment	ryanque	new	2014-05-15T16:55:03-05:00	2014-05-15T16:55:03-05:00	Interference in channel A just 10 seconds	avaldez
Milestone 2014_05_1 MST-ISR	1617	15 May 16:05 Restart acquisition system	ISR		Acquisition system	ryanque	new	2014-05-15T16:26:37-05:00	2014-05-15T16:26:37-05:00	Due to copying data to another disk.	avaldez
Milestone 2014_05_1 MST-ISR	1616	15 May 14:35 Spark gap calibration	ISR		Start experiment	ryanque	new	2014-05-15T16:10:58-05:00	2014-05-15T16:10:58-05:00	ATR & TR calibration	avaldez
Milestone 2014_05_1 MST-ISR	1615	15 May 10:30 Spark gap calibration	ISR		Start experiment	ryanque	new	2014-05-15T16:10:03-05:00	2014-05-15T16:10:03-05:00	ATR & TR calibration	avaldez
Milestone 2014_05_1 MST-ISR	1614	15 Mayo 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-15T04:03:16-05:00	2014-05-15T04:03:16-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +4.2 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW"	vquesada
Milestone 2014_05_1 MST-ISR	1613	15 May 06:27 AM  Calibration of ATRs and TRs	ISR		Spark Gaps	AValdez	new	2014-05-15T03:36:23-05:00	2014-05-15T03:36:23-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1612	14 May 23:59 pm Figures of rtis, spectros, etc	ISR		Start experiment	AValdez	new	2014-05-15T03:07:00-05:00	2014-05-15T03:07:00-05:00	Figures of rtis, spectros, etc.	avaldez
Milestone 2014_05_1 MST-ISR	1611	15 May 02:33 Calibration of ATRs and TRs	ISR		Spark Gaps	AValdez	new	2014-05-15T02:12:15-05:00	2014-05-15T16:06:20-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1610	14 May 22:33PM  Calibration of ATRs and TRs	ISR		Spark Gaps	AValdez	new	2014-05-15T02:11:05-05:00	2014-05-15T02:11:05-05:00		avaldez
Milestone 2014_05_1 MST-ISR	1609	14 May 23:38 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-14T21:21:14-05:00	2014-05-15T16:07:27-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW

Nota en el ticket anterior 
Dice:
13 Mayo 23:38 Transmitter Power Measurements
Debe decir:
14 Mayo 23:38 Transmitter Power Measurements"	vquesada
Milestone 2014_05_1 MST-ISR	1608	13 May 23:38 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-14T20:34:53-05:00	2014-05-15T16:07:01-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +4.3 dBm
Tx4 +4.1 dBm
Line voltage and power: 4050 VAC, 300 KW"	vquesada
Milestone 2014_05_1 MST-ISR	1607	13 May 07:00 Transmitter Power mesearuments	ISR		Transmitters		new	2014-05-14T16:28:35-05:00	2014-05-14T16:28:35-05:00	"13/05/2014
08:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4060 VAC, 300 KW
09:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +4.1 dBm
 Line voltage and power: 4060 VAC, 300 KW
09:15 RF (OFF)
10:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +4.1 dBm
 Line voltage and power: 4080 VAC, 300 KW
13:45 HV.OFF Door´s Open.
14:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4000 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW
17:45 RF OFF.
18:30 RF ON.
19:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4050 VAC, 290 KW.

"	rtadeo
Milestone 2014_05_1 MST-ISR	1606	14 May 18:30 Experiment start	ISR		Start experiment	J. Ortiz	new	2014-05-14T15:37:28-05:00	2014-05-14T15:37:28-05:00	New empty hard drive installed.	jortiz
Milestone 2014_05_1 MST-ISR	1605	14 May 18:30 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-05-14T15:36:42-05:00	2014-05-14T15:36:42-05:00	Calibration of ATRs and TRs	jortiz
Milestone 2014_05_1 MST-ISR	1604	14 May 17:45 System shutdown for hard drive change	ISR		End experiment	J. Ortiz	new	2014-05-14T14:59:12-05:00	2014-05-14T14:59:12-05:00	System shutdown for hard drive change	jortiz
Milestone 2014_05_1 MST-ISR	1603	14 May 17:42 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T14:58:21-05:00	2014-05-14T14:58:21-05:00	Restart MST-ISR-EEJ.bat in Jars.	jortiz
Milestone 2014_05_1 MST-ISR	1602	14 May 17:27 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T14:44:40-05:00	2014-05-14T14:44:40-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1601	14 May 16:56 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T13:58:44-05:00	2014-05-14T13:58:44-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1600	14 May 16:02 JARS loss of data while recovering	ISR		Acquisition system	J. Ortiz	new	2014-05-14T13:05:08-05:00	2014-05-14T13:05:08-05:00	JARS lost data while automatically restarting and recovering.	jortiz
Milestone 2014_05_1 MST-ISR	1599	14 May 15:10 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T12:11:30-05:00	2014-05-14T12:11:30-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1598	14 May 14:50 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-05-14T11:49:57-05:00	2014-05-14T11:49:57-05:00	 Calibration of ATRs and TRs	jortiz
Milestone 2014_05_1 MST-ISR	1597	14 May 14:10 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T11:25:53-05:00	2014-05-14T11:25:53-05:00	Restart MST-ISR-EEJ.bat in Jars. Took about 10 minutes.	jortiz
Milestone 2014_05_1 MST-ISR	1596	14 May 13:43 Transmitters turned off	ISR		Transmitters	J. Ortiz	new	2014-05-14T10:46:10-05:00	2014-05-14T10:46:10-05:00	Transmitters were turned off during maintenance	jortiz
Milestone 2014_05_1 MST-ISR	1595	14 May 12:56 Digisonde was powered on	ISR		Other Instruments	J. Ortiz	new	2014-05-14T09:56:47-05:00	2014-05-14T09:56:47-05:00	Digisonde was powered on. Expected interference in Channel 1 every 5 minutes.	jortiz
Milestone 2014_05_1 MST-ISR	1594	14 May 12:47 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T09:48:40-05:00	2014-05-14T09:48:40-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1593	14 May 12:27 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T09:28:33-05:00	2014-05-14T09:28:33-05:00	Restart MST-ISR-EEJ.bat in Jars acquisition system	jortiz
Milestone 2014_05_1 MST-ISR	1592	14 May 12:03 JARS loss of data while recovering	ISR		Acquisition system	J. Ortiz	new	2014-05-14T09:06:32-05:00	2014-05-14T09:06:32-05:00	JARS lost data while automatically restarting and recovering.	jortiz
Milestone 2014_05_1 MST-ISR	1591	14 May 11:45 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T08:50:41-05:00	2014-05-14T08:50:41-05:00	Restart MST-ISR-EEJ.bat in Jars acquisition system	jortiz
Milestone 2014_05_1 MST-ISR	1590	14 May 10:47 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-05-14T07:45:31-05:00	2014-05-14T07:45:31-05:00	Calibration of ATRs and TRs	jortiz
Milestone 2014_05_1 MST-ISR	1589	14 May 10:38 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T07:42:16-05:00	2014-05-14T07:42:16-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1588	14 May 10:17 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T07:24:55-05:00	2014-05-14T07:24:55-05:00	Restart MST-ISR-EEJ.bat in Jars acquisition system	jortiz
Milestone 2014_05_1 MST-ISR	1587	14 May 10:09 Digisonde was powered off	ISR		Other Instruments	J. Ortiz	new	2014-05-14T07:23:42-05:00	2014-05-14T07:23:42-05:00	Digisonde was detected to cause interference in Channel 1 every 5 minutes (for a period of a few seconds). Synchronization pulse was left on, but digisonde was powered off	jortiz
Milestone 2014_05_1 MST-ISR	1586	14 May 09:19 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T06:28:26-05:00	2014-05-14T06:28:26-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1585	14 May 08:33 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	J. Ortiz	new	2014-05-14T05:44:05-05:00	2014-05-14T05:44:05-05:00	Restart MST-ISR-EEJ.bat in Jars	jortiz
Milestone 2014_05_1 MST-ISR	1584	14 May 06:48 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-05-14T04:37:49-05:00	2014-05-14T04:37:49-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_05_1 MST-ISR	1583	14 May 04:00 Restart mst-isr-eej.py and now there are figures	ISR		Process/Analysis Program	P. Condor	new	2014-05-14T04:37:04-05:00	2014-05-14T04:37:04-05:00	Restart mst-isr-eej.py and now there are figures of rti and spectros ISR and EEJ, after of very restarts.	pcondor
Milestone 2014_05_1 MST-ISR	1582	14 May 03:00 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-05-14T04:34:35-05:00	2014-05-14T04:34:35-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_05_1 MST-ISR	1581	14 May 01:30 Restart MST-ISR-EEJ.bat in Jars	ISR		Acquisition system	P. Condor	new	2014-05-14T04:30:50-05:00	2014-05-14T04:30:50-05:00	Restart MST-ISR-EEJ.bat in Jars	pcondor
Milestone 2014_05_1 MST-ISR	1580	14 May 01:08 Restart MST-ISR-EEJ.bat and mst-isr-EEJ.py	ISR		Acquisition system	P. Condor	new	2014-05-14T04:28:52-05:00	2014-05-14T04:28:52-05:00	Restart MST-ISR-EEJ.bat and mst-isr-EEJ.py. Now there are figures of rtis and spectros.	pcondor
Milestone 2014_05_1 MST-ISR	1579	14 May 00:00 Figures of spectros	ISR		Process/Analysis Program	P. Condor	new	2014-05-14T04:24:09-05:00	2014-05-14T04:24:09-05:00	Figures of spectros and rtis	pcondor
Milestone 2014_05_1 MST-ISR	1578	13 May 23:48 Restart MST-ISR-EEj.bat in Jars	ISR		Acquisition system	P. Condor	new	2014-05-14T04:22:02-05:00	2014-05-14T04:22:02-05:00	Restart MST-ISR-EEj.bat in Jars	pcondor
Milestone 2014_05_1 MST-ISR	1577	13 May 23:00 Calibration of TRs and ATRs	ISR		Antennas	A. Coronado	new	2014-05-14T04:20:35-05:00	2014-05-14T04:20:35-05:00	Calibration of TRs and ATRs	pcondor
Milestone 2014_05_1 MST-ISR	1576	13 May 22:56 Restart MST-ISR-ISR.bat in Jars	ISR		Acquisition system	P. Condor	new	2014-05-14T04:19:24-05:00	2014-05-14T04:19:24-05:00	Restart MST-ISR-EEJ.bat in Jars	pcondor
Milestone 2014_05_1 MST-ISR	1575	13 May 22:45 Restart Batch in Jars	ISR		Acquisition system	P. Condor	new	2014-05-14T04:16:02-05:00	2014-05-14T04:16:02-05:00	Restart Batch in Jars	pcondor
Milestone 2014_05_1 MST-ISR	1574	13 May 22:19 Restart Batch in Jars	ISR		Acquisition system	P. Condor	new	2014-05-14T04:15:02-05:00	2014-05-14T04:15:02-05:00	Restart Batch MST-EEJ-ISR in Jars	pcondor
Milestone 2014_05_1 MST-ISR	1573	13 May 21:42 Restart Batch in Jars	ISR		Acquisition system	P. Condor	new	2014-05-14T04:14:09-05:00	2014-05-14T04:14:09-05:00	Restart Batch MST-EEJ-ISR in Jars	pcondor
Milestone 2014_05_1 MST-ISR	1572	14 Mayo 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-14T04:04:45-05:00	2014-05-14T04:04:45-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.1 dBm
Line voltage and power: 4060 VAC, 310 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.2 dBm
Line voltage and power: 4100 VAC, 310 KW"	vquesada
Milestone 2014_05_1 MST-ISR	1571	13 Mayo 23:06 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-13T20:03:00-05:00	2014-05-13T20:03:00-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.1 dBm
Line voltage and power: 4060 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.1 dBm
Line voltage and power: 4060 VAC, 310 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.1 dBm
Line voltage and power: 4060 VAC, 310 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 +4.4 dBm
Tx4 +4.1 dBm
Line voltage and power: 4060 VAC, 310 KW"	vquesada
Milestone 2014_05_1 MST-ISR	1570	13 May 19:00 Transmitter Power mesearuments	ISR		Transmitters		new	2014-05-13T16:32:57-05:00	2014-05-13T16:32:57-05:00	"13/05/2007
07:09 LV ON
07:30 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4050 VAC, 280 KW
08:25 Screen failure source
09:00 TX Power sample (-70 dB coupling)
 Tx1 +4.3 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4060 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
 Tx1 +4.3 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4060 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4010 VAC, 280 KW
11:33 power line cut.
12:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4010 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4010 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
 Tx1 +3.8 dBm
 Tx4 +3.8 dBm
 Line voltage and power: 4010 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
 Tx1 +4.1 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4080 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
 Tx1 +3.9 dBm
 Tx4 +3.9 dBm
 Line voltage and power: 4040 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
 Tx1 +4.0 dBm
 Tx4 +4.0 dBm
 Line voltage and power: 4060 VAC, 290 KW









"	rtadeo
Milestone 2014_05_1 MST-ISR	1569	13 May 19:15 Calibration of ATRs and TRs	ISR		Antennas	dsuarez	new	2014-05-13T16:30:01-05:00	2014-05-13T16:30:01-05:00		dsuarez
Milestone 2014_05_1 MST-ISR	1568	13 May 15:30 Calibration of ATRs and TRs	ISR		Antennas	dsuarez	new	2014-05-13T16:29:33-05:00	2014-05-13T16:29:33-05:00		dsuarez
Milestone 2014_05_1 MST-ISR	1567	13 May 13:29 Acquisition System	ISR		Acquisition system	dsuarez	new	2014-05-13T16:28:55-05:00	2014-05-13T16:28:55-05:00	after than doing a lot of test to reduce interference signals and other code verification, the acquisition system takes radar data in continuously form.	dsuarez
Milestone 2014_05_1 MST-ISR	1566	13 May 11:45 Interference Signals in EEJ part	ISR		Reception	dsuarez	new	2014-05-13T16:25:31-05:00	2014-05-13T16:25:31-05:00	"the interference signal was reduced doing a better location of the BNC cables in the JARS system.
"	dsuarez
Milestone 2014_05_1 MST-ISR	1565	13 May 07:35 loss of the electric power	ISR		General	dsuarez	new	2014-05-13T16:16:15-05:00	2014-05-13T16:30:31-05:00	the electricity came back after than 10 seconds but the transmitter takes 15 minutes to be online.	dsuarez
Milestone 2014_05_1 MST-ISR	1564	13 May 11:10 Calibration of ATRs and TRs	ISR		Antennas	dsuarez	new	2014-05-13T16:06:31-05:00	2014-05-13T16:30:45-05:00		dsuarez
Milestone 2014_05_1 MST-ISR	1563	13 May 10:19 Acquisition System was restarted	ISR		Acquisition system	dsuarez	new	2014-05-13T16:05:54-05:00	2014-05-13T16:31:06-05:00	tanking off a amplification stage in the receivers	dsuarez
Milestone 2014_05_1 MST-ISR	1562	13 May 08:36 The Transmitter goes down	ISR		Transmitters	dsuarez	new	2014-05-13T16:02:13-05:00	2014-05-13T16:32:09-05:00	Problems with Power Amplifier 1, this problem was fixed after than 5 minutes	dsuarez
Milestone 2014_05_1 MST-ISR	1561	13 May 07:35 Calibration of ATRs and TRs	ISR		Antennas	dsuarez	new	2014-05-13T15:56:53-05:00	2014-05-13T16:32:32-05:00		dsuarez
Milestone 2014_05_1 MST-ISR	1560	13 May 07:35 The beginning of the experiment	ISR		Start experiment	dsuarez	new	2014-05-13T15:55:04-05:00	2014-05-13T16:32:54-05:00		dsuarez
Milestone 2014_05_1 MST-ISR	1559	12 May 15:06 Antenna VSWR	ISR		Antennas	ryanque	new	2014-05-12T12:06:06-05:00	2014-05-12T12:06:06-05:00	"Antenna VSWR

Wup   1.03 49.94 1.00
Wdn   1.02 49.94 1.01
Ndn   1.05 49.97 1.01
Nup   1.07 49.98 1.05
Eup   1.04 49.87 1.01
Edn   1.04 49.97 1.01
Sdn   1.06 49.95 1.05
Sup   1.05 49.99 1.00

Matress: 1.08"	ryanque
Milestone 2014_05_1 MST-ISR	1558	12 May 15:05 Log created for MST-ISR	ISR		Start experiment	ryanque	new	2014-05-12T12:02:14-05:00	2014-05-12T12:02:14-05:00	The log has been created.	ryanque
Milestone 2014_05 Imaging+ISR	1557	09 May 08:00 End Experiment	ISR+Imaging		End experiment	P. Condor	new	2014-05-09T05:11:14-05:00	2014-05-09T05:11:14-05:00	"End Experiment.
Put figures of rtis, power, noise, etc"	pcondor
Milestone 2014_05 Imaging+ISR	1556	09 May 08:00 Transmitter Power mesearuments	ISR+Imaging		Transmitters		new	2014-05-09T04:32:33-05:00	2014-05-09T04:32:33-05:00	"08/05/2007
20:00 TX Power sample (-70 dB coupling)
 Tx1 +6.2 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dv3 -6.5 dBm
 Line voltage and power: 4050 VAC, 310 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +6.2 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dv3 -6.5 dBm
22:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.0 dBm
 Tx4 +2.2 dBm
 Dv3 -6.6 dBm
 Line voltage and power: 4020 VAC, 300 KW
22:10 Falla PA4 (Atrad1)
23:00 TX Power sample (-70 dB coupling)
 Tx1 +5.9 dBm
 Tx2 +2.2 dBm
 Tx4 +2.3 dBm
 Dv3 -6.6 dBm

09/05/2014
00:00 Driver 3 (OFF)
00:00 TX Power sample (-70 dB coupling)
 Tx1 +6.2 dBm
 Tx2 +2.2 dBm
 Tx4 +2.2 dBm
 Dv3 off
 Line voltage and power: 4020 VAC, 300 KW
01:00 Transmitter failure (Atrad 3)
01:37 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.0 dBm / +5.1 dBm
 Tx4 +2.3 dBm
 Line voltage and power: 4060 VAC, 310 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +5.1 dBm
 Tx2 +2.1 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +2.0 dBm / +5.1 dBm
 Tx4 +2.4 dBm
 Line voltage and power: 4060 VAC, 310 KW
08:00 transmitter Off.


"	rtadeo
Milestone 2014_05 Imaging+ISR	1555	09 May 04:35 Calibration of TRs and ATRs	ISR+Imaging		Antennas	J. Lavado	new	2014-05-09T03:19:07-05:00	2014-05-09T03:19:07-05:00	Calibration of TRs and ATRs	pcondor
Milestone 2014_05 Imaging+ISR	1554	09 May 01:36 On Transmitter of EW_Drifts	ISR+Imaging		Transmitters	P. Condor	new	2014-05-09T03:18:02-05:00	2014-05-09T03:18:02-05:00	 On Transmitter of EW_Drifts, all is ok.	pcondor
Milestone 2014_05 Imaging+ISR	1553	09 May 01:12 Shut down Transmitter	ISR+Imaging		Transmitters	P. Condor	new	2014-05-09T03:16:28-05:00	2014-05-09T03:16:28-05:00	Shut down Transmitter to change transmitter of EW_Drifts.	pcondor
Milestone 2014_05 Imaging+ISR	1552	09 May 00:50 Low Power Channels EW_Drifts	ISR+Imaging		Transmitters	P. Condor	new	2014-05-09T03:14:25-05:00	2014-05-09T03:14:25-05:00	"Low Power Channels EW_Drifts.
We are repairing."	pcondor
Milestone 2014_05 Imaging+ISR	1551	09 May 00:30 Calibration of ATrs and TRs	ISR+Imaging		Antennas	J. Lavado	new	2014-05-09T03:10:26-05:00	2014-05-09T03:10:26-05:00	Calibration of ATrs and TRs	pcondor
Milestone 2014_05 Imaging+ISR	1550	08 May 23:59 Figures of rtis, spectros, etc	ISR+Imaging		Process/Analysis Program	P. Condor	new	2014-05-09T03:05:42-05:00	2014-05-09T03:05:42-05:00	 Figures of rtis, spectros, etc.	pcondor
Milestone 2014_05 Imaging+ISR	1549	08 May 22:10 Faraday Ch A falls	ISR+Imaging		Transmitters	P. Condor	new	2014-05-09T03:04:28-05:00	2014-05-09T03:04:28-05:00	 Faraday Ch A falls	pcondor
Milestone 2014_05 Imaging+ISR	1548	08 May 20:30 Calibration of ATRs and TRs	ISR+Imaging		Antennas	J. Lavado	new	2014-05-09T02:59:49-05:00	2014-05-09T02:59:49-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_05 Imaging+ISR	1547	08 May 19:00 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-08T17:00:52-05:00	2014-05-08T17:00:52-05:00	"08:00 Transmitter OFF, HV failure at PA 4
14:00 Transmitter ON
14:17 alarm SCREEN PA 1 
14:25 alarm SCREEN PA 1
14:31 alarm SCREEN PA 1
14:33 alarm SCREEN PA 1
15:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.2 dBm/ +5.2 dBm
Tx4 +2.1 dBm
Line voltage and power: 4010 VAC, 310 KW 
15:30 CROWBAR
16:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +1.9 dBm/ +5.1 dBm
Tx4 +2.0 dBm
Line voltage and power: 4010 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.1 / 5.2 dBm
Tx4 +2.0 dBm
Line voltage and power: 4000 VAC, 310 KW
17:30 alarm SCREEN Driver 1
18:00 TX Power sample (-70 dB coupling) IMAGING ON
Tx1 +6.0 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
DR3 -6.4 dBm
Line voltage and power: 4010 VAC, 310 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.2 dBm
Tx4 +2.1 dBm
DR3 -6.4 dBm
Line voltage and power: 4050 VAC, 310 KW
19:08 alarm SCREEN PA 4
"	ryaya
Milestone 2014_05 Imaging+ISR	1546	08 May 17:40 Spark gaps adjustment, transmitters power recovered	ISR+Imaging		Spark Gaps	jverastegui	new	2014-05-08T15:07:50-05:00	2014-05-08T15:07:50-05:00		jverastegui
Milestone 2014_05 Imaging+ISR	1545	08 May 17:30 Low transmitters power	ISR+Imaging		Transmitters	jverastegui	new	2014-05-08T15:05:17-05:00	2014-05-08T15:05:17-05:00		jverastegui
Milestone 2014_05 Imaging+ISR	1544	08 May 14:20 Transmitters at their maximum power	ISR+Imaging		Transmitters	jverastegui	new	2014-05-08T11:40:27-05:00	2014-05-08T11:40:27-05:00		jverastegui
Milestone 2014_05 Imaging+ISR	1543	08 May 14:10 Transmitters restored	ISR+Imaging		Transmitters	jverastegui	new	2014-05-08T11:38:12-05:00	2014-05-08T11:38:12-05:00		jverastegui
Milestone 2014_05 Imaging+ISR	1542	08 May 08:00 Transmitter 4 fault detected, transmitters shut down	ISR+Imaging		Transmitters	jverastegui	new	2014-05-08T07:14:29-05:00	2014-06-16T10:08:25-05:00		jverastegui
Milestone 2014_05 Imaging+ISR	1541	08 May 07:13 Calibration ATR and TR	ISR+Imaging		Spark Gaps	J. Ortiz	new	2014-05-08T04:10:07-05:00	2014-05-08T04:10:07-05:00		jortiz
Milestone 2014_05 Imaging+ISR	1540	08 Mayo 07:12 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-08T04:07:02-05:00	2014-05-08T04:07:02-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.3 dBm
Tx4 +2.2 dBm
D3 -6.7 dBm
Line voltage and power: 4060 VAC, 320 KW
00:05 Driver 3 OFF
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.4, +5.7 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 320 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.4, +5.7 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 320 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.4, +5.7 dBm
Tx4 +2.4 dBm
Line voltage and power: 4050 VAC, 320 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +2.4, +5.3 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 320 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +2.4, +5.3 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 320 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +2.4, +5.3 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 320 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +2.4, +5.3 dBm
Tx4 +2.5 dBm
Line voltage and power: 4050 VAC, 320 KW"	vquesada
Milestone 2014_05 Imaging+ISR	1539	08 May 03:25 Calibration ATR and TR	ISR+Imaging		Spark Gaps	J. Ortiz	new	2014-05-08T00:31:03-05:00	2014-05-08T00:31:03-05:00		jortiz
Milestone 2014_05 Imaging+ISR	1538	08 May 00:00 Figures of rtis, noise,etc	ISR+Imaging		Process/Analysis Program	J. Ortiz	new	2014-05-07T21:12:24-05:00	2014-05-07T21:12:24-05:00	Figures of rtis, noise,etc	jortiz
Milestone 2014_05 Imaging+ISR	1537	08 May 00:04 End Imaging	ISR+Imaging		Acquisition system	J. Ortiz	new	2014-05-07T21:03:19-05:00	2014-05-07T21:03:19-05:00		jortiz
Milestone 2014_05 Imaging+ISR	1536	07 May 23:18 Calibration ATR and TR	ISR+Imaging		Spark Gaps	J. Ortiz	new	2014-05-07T20:20:33-05:00	2014-05-07T20:20:33-05:00		jortiz
Milestone 2014_05 Imaging+ISR	1535	07 Mayo 23:20 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-07T20:12:13-05:00	2014-05-07T20:12:13-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 320 KW 
20:40 crowbar por caida de tension
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 320 KW 
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.4 dBm
Tx4 +2.4 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 320 KW 
22:49 Crowbar por caida de tension
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.3 dBm
Tx4 +2.2 dBm
D3 -6.7 dBm
Line voltage and power: 4060 VAC, 320 KW "	vquesada
Milestone 2014_05 Imaging+ISR	1534	07 May 22:50 Low tension on transmitter crowbar	ISR+Imaging		Transmitters	Jorge Ortiz	new	2014-05-07T19:51:43-05:00	2014-05-07T19:51:43-05:00	Low tension on crowbar in transmitter room. Fixed.	jortiz
Milestone 2014_05 Imaging+ISR	1533	07 May 19:00 Transmitter Power mesearuments	ISR+Imaging		Transmitters		new	2014-05-07T16:24:22-05:00	2014-05-07T16:24:22-05:00	"07/05/2014
08:00 TX Power sample (-70 dB coupling)
 Tx1 +5.9 dBm
 Tx2 +2.1 dBm/+5.2dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 310 KW 
09:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.2,+5.4dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4050 VAC, 310 Kw
10:00 TX Power sample (-70 dB coupling)
 Tx1 +5.9 dBm
 Tx2 +2.2,+5.2dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4050 VAC, 310 Kw
11:08 Falla de Screen Driver 1.
11:48 RF (OFF)X Noise ch B (Faraday)
12:00 RF (ON)
13:00 TX Power sample (-70 dB coupling)
 Tx1 +5.0 dBm
 Tx2 +2.3,+5.2dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4050 VAC, 310 Kw
14:00 TX Power sample (-70 dB coupling)
 Tx1 +5.0 dBm
 Tx2 +2.3,+5.2dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4000 VAC, 300 Kw
15:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.0,+5.1dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4000 VAC, 300 Kw
16:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.0,+5.1dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4000 VAC, 300 Kw
17:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2,+5.3dBm
 Tx4 +2.2 dBm
 Line voltage and power: 4000 VAC, 300 Kw
17:30 Drv3 (ON) -7.2dBm
18:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm
 Tx4 +2.3 dBm
 Drv3 -7.2 dBm
 Line voltage and power: 4050 VAC, 300 Kw
19:00 TX Power sample (-70 dB coupling)
 Tx1 +5.4 dBm
 Tx2 +2.2 dBm
 Tx4 +2.3 dBm
 Drv3 -7.2 dBm
 Line voltage and power: 4050 VAC, 300 Kw
 "	rtadeo
Milestone 2014_05 Imaging+ISR	1532	07 May 15:50 Calibration ATR and TR	ISR		Start experiment	ryanque	new	2014-05-07T15:17:30-05:00	2014-05-07T15:17:30-05:00		ryanque
Milestone 2014_05 Imaging+ISR	1531	07 May 11:45 Interference on channel B of Faraday experiment	ISR		Reception	ryanque	new	2014-05-07T15:16:34-05:00	2014-05-07T15:18:06-05:00	"11:00 - Interference in channel B of Faraday experiment
11:50 - Calibration of ATR and TR
12:04 - Channel B attenuates 1 dB
Channel A 9 dB
Channel B 8 dB
12:20 - The problem has been found a cable and a converter that connects the reception of Faraday was not good.
12:40 - Channel B has been open 1 dB
Channel A 9 dB
Channel B 7 dB"	ryanque
Milestone 2014_05 Imaging+ISR	1530	07 May 08:35 Interchange TR Ew Drift	ISR		Reception	ryanque	new	2014-05-07T15:09:42-05:00	2014-05-07T15:09:42-05:00	Interchange between TR channel A and B of EW Drift experiment.	ryanque
Milestone 2014_05 Imaging+ISR	1529	07 May 08:30 Calibration ATR - TR	ISR		Spark Gaps	ryanque	new	2014-05-07T15:08:04-05:00	2014-05-07T15:08:04-05:00	Calibration of ATR and TR	ryanque
Milestone 2014_05 Imaging+ISR	1528	07 Mayo 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-07T03:59:58-05:00	2014-05-07T03:59:58-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3 dBm
Tx4 +1.2 dBm
D3 -6.6 dBm
Line voltage and power: 4050 VAC, 310 KW 
00:15 Driver 3 OFF
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3,+5.2dBm
Tx4 +1.4 dBm
Line voltage and power: 4050 VAC, 310 Kw
01:48 Falla interloock del Tx4 y vuela fusible de fuente +B driver 4
02:30 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4080 VAC, 330 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 320 Kw
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3,+5.2dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 320 Kw"	vquesada
Milestone 2014_05 Imaging+ISR	1527	07 May 02:30  Problems  PA4 solved	ISR		Transmitters	AValdez	new	2014-05-06T23:58:44-05:00	2014-05-06T23:58:44-05:00	02:30am Continues experiment	avaldez
Milestone 2014_05 Imaging+ISR	1526	07 May 01:45 Calibration ATRs-TRs	ISR		Spark Gaps	AValdez	new	2014-05-06T23:55:34-05:00	2014-05-07T00:01:33-05:00		avaldez
Milestone 2014_05 Imaging+ISR	1525	07 May 00:09 End Imaging	ISR		Acquisition system	AValdez	new	2014-05-06T23:53:26-05:00	2014-05-06T23:53:26-05:00		avaldez
Milestone 2014_05 Imaging+ISR	1524	07 May 01:48 Problems with Power Amplifier 4	ISR		Transmitters	AValdez	new	2014-05-06T23:50:50-05:00	2014-05-06T23:56:17-05:00	"There was a problem with interlog of PA4, fault relay.
At 02:30 am the problem was fixed."	avaldez
Milestone 2014_05 Imaging+ISR	1523	06 Mayo 23:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-05-06T19:59:48-05:00	2014-05-06T19:59:48-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.4 dBm
Tx4 +1.9 dBm
D3 -6.5  dBm
Line voltage and power: 4050 VAC, 320 KW 
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.4 dBm
Tx4 +1.9 dBm
D3 -6.5  dBm
Line voltage and power: 4050 VAC, 310 KW 
22:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.4 dBm
Tx4 +1.4 dBm
D3 -6.4  dBm
Line voltage and power: 4080 VAC, 310 KW 
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.3 dBm
Tx4 +1.0 dBm
D3 -6.6  dBm
Line voltage and power: 4050 VAC, 310 KW "	vquesada
Milestone 2014_05 Imaging+ISR	1522	06 May19:00 Transmitter Power measurements	ISR		Transmitters		new	2014-05-06T16:47:01-05:00	2014-05-06T16:47:01-05:00	"08:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.1 dBm/ +5.2 dBm
Tx4 +1.7 dBm
Line voltage and power: 4030 VAC, 310 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +2.2 dBm/ +5.2 dBm
Tx4 +2.0 dBm
Line voltage and power: 4060 VAC, 315 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.4 dBm/ +5.4 dBm
Tx4 +2.0 dBm
Line voltage and power: 4060 VAC, 315 KW
11:20 PA 1 alarm failure
12:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.2 dBm/ +5.2 dBm
Tx4 +2.0 dBm
Line voltage and power: 4040 VAC, 310 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.1 dBm/ +5.0 dBm
Tx4 +2.0 dBm
Line voltage and power: 4060 VAC, 310 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0 dBm/ +4.9 dBm
Tx4 +1.9 dBm
Line voltage and power: 4030 VAC, 310 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +2.1 dBm/ +5.0 dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 310 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.2 dBm/ +5.2 dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 310 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3 dBm
Tx4 +2.0 dBm
D3 -6.4 dBm 
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.2 dBm
Tx4 +2.0 dBm
D3 -6.4 dBm
Line voltage and power: 4060 VAC, 315 KW 
"	ryaya
Milestone 2014_05 Imaging+ISR	1521	06 May 07:00 Transmitter Power mesearuments	ISR+Imaging		Transmitters		new	2014-05-06T04:26:54-05:00	2014-05-06T04:26:54-05:00	"05/05/2014
20:00 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +2.4 dBm
 Tx4 +2.0 dBm
 Dr3 -6.6 dBm
 Line voltage and power: 4050 VAC, 300 KW
21:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.3 dBm
 Tx4 +1.9 dBm
 Dr3 -6.7 dBm
22:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.3 dBm
 Tx4 +1.9 dBm
 Dr3 -6.7 dBm
 Line voltage and power: 4060 VAC, 300 KW
22:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.3 dBm
 Tx4 +1.9 dBm
 Dr3 -6.7 dBm

06/05/2014
00:00 Driver 3 (OFF)
00:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.3 dBm / +5.4 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4090 VAC, 320 KW
01:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.3 dBm / +5.4 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4090 VAC, 320 KW
02:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.3 dBm / +5.4 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4090 VAC, 320 KW
03:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.2 dBm / +5.3 dBm
 Tx4 +1.8 dBm
 Line voltage and power: 4050 VAC, 310 KW
04:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.2 dBm / +5.3 dBm
 Tx4 +1.8 dBm
 Line voltage and power: 4050 VAC, 310 KW
05:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.2 dBm / +5.3 dBm
 Tx4 +1.8 dBm
 Line voltage and power: 4050 VAC, 310 KW
06:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.2 dBm / +5.3 dBm
 Tx4 +1.8 dBm
 Line voltage and power: 4050 VAC, 310 KW
07:00 TX Power sample (-70 dB coupling)
 Tx1 +6.0 dBm
 Tx2 +2.2 dBm / +5.3 dBm
 Tx4 +1.8 dBm
 Line voltage and power: 4050 VAC, 310 KW
"	rtadeo
Milestone 2014_05 Imaging+ISR	1520	06 May 06:58 Calibration ATRs-TRs	ISR+Imaging		Antennas	J. Lavado	new	2014-05-06T03:53:53-05:00	2014-05-06T03:53:53-05:00	Calibration ATRs-TRs	pcondor
Milestone 2014_05 Imaging+ISR	1519	06 May 00:00 Figures of rtis, noise,etc	ISR+Imaging		Process/Analysis Program	P. Condor	new	2014-05-06T03:43:44-05:00	2014-05-06T03:43:44-05:00	Figures of rtis, noise,etc	pcondor
Milestone 2014_05 Imaging+ISR	1518	06 May 02:40 Calibration ATRs-TRs	ISR+Imaging		Antennas	J. Lavado	new	2014-05-06T03:42:18-05:00	2014-05-06T03:42:18-05:00	Calibration ATRs-TRs	pcondor
Milestone 2014_05 Imaging+ISR	1517	06 May 00:09 End Imaging	ISR+Imaging		Acquisition system	P. Condor	new	2014-05-06T03:41:19-05:00	2014-05-06T03:41:19-05:00	 End Imaging. No Spread F	pcondor
Milestone 2014_05 Imaging+ISR	1516	05 May 22:30 Calibration ATRs-TRs	ISR+Imaging		Antennas	J. Lavado	new	2014-05-06T03:39:47-05:00	2014-05-06T03:39:47-05:00	Calibration ATRs-TRs	pcondor
Milestone 2014_05 Imaging+ISR	1515	05 May19:00 Transmitter Power measurements	ISR		Transmitters		new	2014-05-05T16:48:27-05:00	2014-05-05T16:48:27-05:00	"17:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2 dBm/ +5.2 dBm
Tx4 +1.9 dBm
Line voltage and power: 4070 VAC, 310 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.2 dBm
Tx4 +1.9 dBm
D3  -8.0 dBm 
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.4 dBm
Tx4 +2.0 dBm
D3  -6.4 dBm
Line voltage and power: 4080 VAC, 315 KW 
"	ryaya
Milestone 2014_05 Imaging+ISR	1514	05 May 19:16 Restart of Faraday acquisition	ISR+Imaging		Acquisition system	I. Manay	new	2014-05-05T16:11:52-05:00	2014-05-05T16:11:52-05:00		imanay
Milestone 2014_05 Imaging+ISR	1513	05 May 18:00 Start of the Imaging experiment	ISR+Imaging		Acquisition system	I. Manay	new	2014-05-05T15:33:01-05:00	2014-05-05T15:33:01-05:00	RF2 output of the EW_Drift DDS was unplugged and Imaging system was started (Driver transmision).	imanay
Milestone 2014_05 Imaging+ISR	1512	05 May 17:55 Change of the attenuation	ISR+Imaging		Reception	I. Manay	new	2014-05-05T15:28:19-05:00	2014-05-05T15:28:19-05:00	Channel A of Faraday was attenuated 1 dB.	imanay
Milestone 2014_05 Imaging+ISR	1511	05 May 17:30 Restart of Faraday experiment	ISR+Imaging		Reception	I. Manay	new	2014-05-05T15:26:12-05:00	2014-05-05T15:26:12-05:00	There was a connection error between A and B reception cables. Those cables were exchanged.	imanay
Milestone 2014_05 Imaging+ISR	1510	05 May 17:15 Start of the experiment	ISR+Imaging		Start experiment	I. Manay	new	2014-05-05T15:23:07-05:00	2014-05-05T15:36:59-05:00	"These are the current attenuations:

1) EW_Drift:

 A : 0
 B : 2
 C : 2
 D : 0

2) Faraday:

 A : 8
 B : 7

3) Imaging:

 A : 0
 B : 2
 C : 2
 D : 0
 E : 2
 F : 2
 G : 0
 H : 4"	imanay
Milestone 2014_05 Imaging+ISR	1509	05 May 11:47 Antenna VSWR	ISR		Antennas	ryanque	new	2014-05-05T08:44:44-05:00	2014-05-05T08:44:44-05:00	"Antenna VSWR
SUp - 1.03
SDn - 1.01
EDn - 1.02
EUp - 1.03
NUp - 1.04
NDn - 1.04
WDn - 1.04
Wup - 1.02
Hysell - 1.10"	ryanque
Milestone 2014_05 Imaging+ISR	1508	05 May 11:37 Log for Imaging+ISR experiment created	ISR		Start experiment	ryanque	new	2014-05-05T08:32:17-05:00	2014-05-05T08:32:17-05:00	The log for the Imaging + ISR campaign has been created.	ryanque
Milestone 2014_04_ISR+Imaging	1507	25 Apr 16:50 Interference at the Faraday channels	ISR+Imaging		Plot	I. Manay	new	2014-04-25T14:06:34-05:00	2014-04-25T14:06:34-05:00	RTi plots shows interferences every 15 minutes. Vipir, abs were off after the blackout.	imanay
Milestone 2014_04_ISR+Imaging	1506	25 Apr 15:35 Testing a repaired TR	ISR+Imaging		Reception	A. Belleza	new	2014-04-25T13:51:50-05:00	2014-04-25T13:51:50-05:00	Two TR's were repaired. One of them replaced the TR at the B channel. Two TR's were left as a backup.	imanay
Milestone 2014_04_ISR+Imaging	1505	25 Apr 15:34 Restart of EW_drift acquisition system	ISR+Imaging		Acquisition system	I. Manay	new	2014-04-25T13:37:08-05:00	2014-04-25T13:37:08-05:00		imanay
Milestone 2014_04_ISR+Imaging	1504	25 Apr 14:15 Change of the attenuation at the B channel	ISR+Imaging		Reception	I. Manay	new	2014-04-25T13:33:55-05:00	2014-04-25T13:33:55-05:00	"Atenuator was open 1 db at the B channel.
These are the current attenuations:

EW_Drift:
A : 0 dB
B : 2 dB
C : 1 dB
D : 0 dB

Faraday:
A : 8 dB
B : 9 dB"	imanay
Milestone 2014_04_ISR+Imaging	1503	25 Apr 14:00 Problems with a TR of the EW_Drift experiment (A channel)	ISR+Imaging		Reception	I. Manay	new	2014-04-25T13:29:48-05:00	2014-04-25T13:29:48-05:00	Drop was seen at the A channel. Some tests were done from 13:20 to 14:00 and it was found that the TR was the problem.	imanay
Milestone 2014_04_ISR+Imaging	1502	25 Apr 13:31 spark gap adjusments	ISR+Imaging		Spark Gaps	A. Belleza	new	2014-04-25T12:14:25-05:00	2014-04-25T12:14:25-05:00		imanay
Milestone 2014_04_ISR+Imaging	1501	25 Apr 12:25 Restart of EW_drift acquisition system	ISR+Imaging		Acquisition system	I. Manay	new	2014-04-25T12:13:47-05:00	2014-04-25T12:13:47-05:00	Acquisition system restarted itself and then manually.	imanay
Milestone 2014_04_ISR+Imaging	1500	25 Apr 11:47 Restart of EW_drift acquisition system	ISR+Imaging		Acquisition system	I. Manay	new	2014-04-25T12:13:03-05:00	2014-04-25T12:13:03-05:00	Acquisition system restarted itself and then manually.	imanay
Milestone 2014_04_ISR+Imaging	1499	25 Apr 08:27 spark gap adjusments	ISR+Imaging		Spark Gaps	A. Belleza	new	2014-04-25T08:10:41-05:00	2014-04-25T08:10:41-05:00		imanay
Milestone 2014_04_ISR+Imaging	1498	25 Apr 10:00 2nd restart of the experiment	ISR+Imaging		Start experiment	I. Manay	new	2014-04-25T08:09:26-05:00	2014-04-25T08:09:26-05:00	The experiment was restarted after a second short blackout(5 to 10 minutes).	imanay
Milestone 2014_04_ISR+Imaging	1497	25 Apr 08:30 Restart of the experiment	ISR+Imaging		Break Experiment	I. Manay	new	2014-04-25T08:06:32-05:00	2014-04-25T08:06:32-05:00	The experiment was restarted after the blackout the night before.	imanay
Milestone 2014_04_ISR+Imaging	1496	24 Apr 18:30 Transmitter Power mesearuments	ISR+Imaging		Transmitters		new	2014-04-24T16:05:15-05:00	2014-04-24T16:05:15-05:00	"24/04/2014
 08:00 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +1.9 dBm/ +5.0 dBm
 Tx4 +2.1 dBm
 Line voltage and power: 4050 VAC, 310 KW
 09:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +2.0 dBm/ +5.0 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4000 VAC, 300 KW 
 10:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm/ +5.0 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4000 VAC, 300 KW 
 11:00 TX Power sample (-70 dB coupling)
 Tx1 +5.2 dBm
 Tx2 +1.8 dBm/ +5.0 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4060 VAC, 300 KW 
 11:41 TX Power sample (-70 dB coupling)
 Tx1 +5.8 dBm
 Tx2 +1.8 dBm/ +5.0 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4050 VAC, 300 KW
 13:30 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +1.8 dBm/+5.0 dBm
 Tx4 +2.0 dBm
 Line voltage and power: 4040 VAC, 295 KW
 14:30 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +1.4 dBm/ +4.6 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4020 VAC, 300 KW
 15:30 TX Power sample (-70 dB coupling)
 Tx1 +5.3 dBm
 Tx2 +1.6 dBm/ +4.7 dBm
 Tx4 +1.9 dBm
 Line voltage and power: 4000 VAC, 295 KW
 16:30 TX Power sample (-70 dB coupling)
 Tx1 +5.7 dBm
 Tx2 +1.9 dBm/ +5.0 dBm
 Tx4 +2.2 dBm
 Line voltage and power: 4060 VAC, 300 KW
 17:30 TX Power sample (-70 dB coupling)
 Tx1 +5.5 dBm
 Tx2 +2.1 dBm
 Tx4 +2.1 dBm
 DR3 -7.8 dBm Imaging: ON
 Line voltage and power: 4050 VAC, 300 KW
 18:30 TX Power sample (-70 dB coupling)
 Tx1 +5.6 dBm
 Tx2 +2.0 dBm
 Tx4 +2.0 dBm
 DR3 -7.7 dBm :imaging
 Line voltage and power: 4050 VAC, 300 KW
 "	rtadeo
Milestone 2014_04_ISR+Imaging	1495	24 Apr 18:37 Calibration of ATR and TR	ISR		Spark Gaps	ryanque	new	2014-04-24T15:53:27-05:00	2014-04-24T15:53:27-05:00		ryanque
Milestone 2014_04_ISR+Imaging	1494	24 Apr 17:18 Interference in EW Drift and Faraday	ISR		Acquisition system	ryanque	new	2014-04-24T15:48:55-05:00	2014-04-24T15:48:55-05:00	"17:18 There is an interference in both EW Drift and Faraday experiment.
17:20 Due to loss of synchronization Faraday acquisition is restarted"	ryanque
Milestone 2014_04_ISR+Imaging	1493	24 Apr 16:26 Restart of EW Drift acquisition	ISR		Acquisition system	ryanque	new	2014-04-24T15:46:28-05:00	2014-04-24T15:46:28-05:00	16:26 Due to loss of synchronization the EW Drift acquisition is restarted.	ryanque
Milestone 2014_04_ISR+Imaging	1492	24 Apr 15:21 Calibration of ATR and TR	ISR		Spark Gaps	ryanque	new	2014-04-24T15:43:37-05:00	2014-04-24T15:43:37-05:00		ryanque
Milestone 2014_04_ISR+Imaging	1491	24 Apr 11:44 Calibration of ATR and TR	ISR		Spark Gaps	ryanque	new	2014-04-24T15:41:31-05:00	2014-04-24T15:41:31-05:00		ryanque
Milestone 2014_04_ISR+Imaging	1490	24 Apr 11:03 Transmitters turned off	ISR		Transmitters	ryanque	new	2014-04-24T15:40:24-05:00	2014-04-24T15:40:24-05:00	"11:03 A problem in TX 4 Driver has been found, concerning the circuit of the plate voltage.
11:31 Transmitters are turned on after fixing the problem."	ryanque
Milestone 2014_04_ISR+Imaging	1489	24 Apr 10:20 Noise increments on Faraday channels	ISR		Transmitters	ryanque	new	2014-04-24T15:37:59-05:00	2014-04-24T15:37:59-05:00	"10:20 Channels A and B of Faraday increase in more than 20 dB.
10:40 Channels A and B of Faraday come back to normal

This problem is due to failures in TX Driver 4."	ryanque
Milestone 2014_04_ISR+Imaging	1488	24 Apr 08:11 Calibration of ATR and TR	ISR		Spark Gaps	ryanque	new	2014-04-24T15:32:36-05:00	2014-04-24T15:32:36-05:00	ATR amd TR have been calibrated.	ryanque
Milestone 2014_04_ISR+Imaging	1487	24 April 04:30 am  Calibration of ATRs and TRs	ISR		Spark Gaps	AValdez	new	2014-04-24T05:08:49-05:00	2014-04-24T05:08:49-05:00		avaldez
Milestone 2014_04_ISR+Imaging	1486	24 April 04:24 SYNCHRONISM LOSS IN EW_DRIFT EXPERIMENT	ISR		Acquisition system	AValdez	new	2014-04-24T05:07:31-05:00	2014-04-24T05:07:31-05:00	The PC of the acquisition system was re-started.	avaldez
Milestone 2014_04_ISR+Imaging	1485	24 April 04:24 SYNCHRONISM LOSS IN EW_DRIFT EXPERIMENT	ISR		Acquisition system	AValdez	new	2014-04-24T05:07:27-05:00	2014-04-24T05:07:27-05:00	The PC of the acquisition system was re-started.	avaldez
Milestone 2014_04_ISR+Imaging	1484	24 April 07:10 Transmitter Power Measurements	ISR		Transmitters		new	2014-04-24T04:24:06-05:00	2014-04-24T04:24:06-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +2.0 dBm
Tx4 +2.3 dBm
D3 OFF
Line voltage and power: 4100 VAC, 310 KW 
01:00 TX Power sample (-70 dB coupling)
Tx1 +5.9 dBm
Tx2 +2.0/5.1 dBm
Tx4 +2.3 dBm
Line voltage and power: 4100 VAC, 310 KW 
02:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0/5.1 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 310 KW 
03:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0/5.1 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 310 KW 
04:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0/5.1 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 310 KW 
05:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.1/5.1 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 310 KW 
06:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.1/5.2 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 310 KW 
07:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.1/5.2 dBm
Tx4 +2.3 dBm
Line voltage and power: 4050 VAC, 310 KW "	vquesada
Milestone 2014_04_ISR+Imaging	1483	23 Apr 23:59 plots of experiments	ISR		Plot	AValdez	new	2014-04-23T22:37:13-05:00	2014-04-23T22:37:13-05:00		avaldez
Milestone 2014_04_ISR+Imaging	1482	24 April  00:20 Calibration of ATRs and TRs	ISR		Spark Gaps	AValdez	new	2014-04-23T22:21:41-05:00	2014-04-23T22:21:41-05:00		avaldez
Milestone 2014_04_ISR+Imaging	1481	23 April  23:59 IDL program is hung  EW_Drift	ISR		Process/Analysis Program	AValdez	new	2014-04-23T22:18:25-05:00	2014-04-23T22:18:25-05:00	 The program had to be finished,then the processing program was restarted.	avaldez
Milestone 2014_04_ISR+Imaging	1480	23 April  23:55  SYNCHRONISM LOSS  IN  EW_DRIFT EXPERIMENT	ISR		Acquisition system	AValdez	new	2014-04-23T22:15:07-05:00	2014-04-23T22:18:15-05:00	The PC of the acquisition system was re-started.	avaldez
Milestone 2014_04_ISR+Imaging	1479	23 April  21:50  Problems in the monitoring program Imaging_plot_coherence.py	ISR		Process/Analysis Program	AValdez	new	2014-04-23T22:09:37-05:00	2014-04-23T22:09:37-05:00	"Because the time reading was very short compared to the time when the pdata was generated,the script was modified. Now, the delay is 10 seconds.
The application is executed and continues monitoring."	avaldez
Milestone 2014_04_ISR+Imaging	1478	23 April  21:10 Calibration of ATRs and TRsF	ISR		Spark Gaps	AValdez	new	2014-04-23T21:50:17-05:00	2014-04-23T21:50:17-05:00		avaldez
Milestone 2014_04_ISR+Imaging	1477	24 April 00:00 Driever 3 OFF	ISR		Transmitters		new	2014-04-23T21:27:41-05:00	2014-04-23T22:25:01-05:00	00:00 HV driver 3 OFF	vquesada
Milestone 2014_04_ISR+Imaging	1476	23 Abril 23:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-04-23T20:19:16-05:00	2014-04-23T22:23:11-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
D3  -8.2
Line voltage and power: 4050 VAC, 310 KW 
21:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
D3  -8.2
Line voltage and power: 4050 VAC, 310 KW 
22:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.0 dBm
Tx4 +2.3 dBm
D3  -8.1
Line voltage and power: 4080 VAC, 310 KW 
23:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.0 dBm
Tx4 +2.3 dBm
D3  -8.1
Line voltage and power: 4080 VAC, 310 KW 
"	vquesada
Milestone 2014_04_ISR+Imaging	1475	23 Apr 19:50 Transmitter Power Measurements	ISR		Transmitters		new	2014-04-23T17:15:14-05:00	2014-04-23T17:15:14-05:00	"08:20 HV ON
08:29 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +1.8 dBm
Line voltage and power: 4050 VAC, 290 KW
09:00 Driver 4 plate failure 
09:15 interlock error at PA 2
09:20 HV OFF
11:45 HV ON
12:30 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +1.6 dBm/ +4.7 dBm
Tx4 +2.0 dBm
Line voltage and power: 4020 VAC, 300 KW 
14:20 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.0 dBm/ +5.2 dBm
Tx4 +2.2 dBm
Line voltage and power: 4020 VAC, 300 KW 
15:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +1.6 dBm/ +4.8 dBm
Tx4 +1.9 dBm
Line voltage and power: 4010 VAC, 300 KW 
16:00 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +2.2 dBm
Line voltage and power: 4050 VAC, 300 KW
16:30 HV OFF
16:50 HV ON (DR 3 TX Imaging ON)
17:15 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.0 dBm
Tx4 +2.2 dBm
DR3 -8.2 dBm
Line voltage and power: 4040 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 +5.8 dBm
Tx2 +2.1 dBm
Tx4 +2.2 dBm
DR3 -8.2 dBm
Line voltage and power: 4080 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 +6.0 dBm
Tx2 +2.3 dBm
Tx4 +2.3 dBm
DR3 -8.0 dBm
Line voltage and power: 4100 VAC, 300 KW"	ryaya
Milestone 2014_04_ISR+Imaging	1474	23 Apr 19:42 Unknown peak in data	ISR+Imaging		Physical Phenomena	J. Ortiz	new	2014-04-23T17:06:11-05:00	2014-04-23T17:06:11-05:00	Receivers were saturated for about 2 minutes and then went back to normal. Hidra suspected.	jortiz
Milestone 2014_04_ISR+Imaging	1473	23 Apr 17:05 Calibration of ATRs and TRs	ISR+Imaging		General		new	2014-04-23T14:18:07-05:00	2014-04-23T14:18:07-05:00		jortiz
Milestone 2014_04_ISR+Imaging	1472	23 Apr 16:51 Imaging Experiment start	ISR+Imaging		Start experiment	J. Ortiz	new	2014-04-23T14:09:31-05:00	2014-04-23T14:09:31-05:00	Experiment restart, with Imaging mode	jortiz
Milestone 2014_04_ISR+Imaging	1471	23 Apr 16:32 Experiment stop	ISR+Imaging		End experiment	J. Ortiz	new	2014-04-23T14:08:28-05:00	2014-04-23T14:08:28-05:00	TR adjustment for Imaging	jortiz
Milestone 2014_04_ISR+Imaging	1470	23 Apr 11:50 Re-starting experiment	ISR+Imaging		Start experiment	J. Ortiz	new	2014-04-23T09:25:21-05:00	2014-04-23T09:25:21-05:00	Transmitters and experiment re-started at 11:50. The acquisition was not re-started since it was still active.	jortiz
Milestone 2014_04_ISR+Imaging	1469	23 Apr 11:48 Calibration of ATRs and TRs	ISR+Imaging		General		new	2014-04-23T09:14:08-05:00	2014-04-23T09:14:08-05:00		jortiz
Milestone 2014_04_ISR+Imaging	1468	23 Apr 09:22 Transmitter maintenance	ISR+Imaging		Transmitters	J. Ortiz	new	2014-04-23T07:29:00-05:00	2014-04-23T07:29:00-05:00	Transmitters were turned off for maintenance to investigate erratic behaviour.	jortiz
Milestone 2014_04_ISR+Imaging	1467	23 Apr 09:16 Drop in transmitter power source	ISR+Imaging		Transmitters	J. Ortiz	new	2014-04-23T06:31:00-05:00	2014-04-23T06:31:00-05:00		jortiz
Milestone 2014_04_ISR+Imaging	1466	23 Apr 08:51 Drop at the channel A of Faraday experiment	ISR+Imaging		Transmitters	J. Ortiz	new	2014-04-23T06:20:52-05:00	2014-04-23T06:20:52-05:00	Due to problems with power source tension to transmitter 4.	jortiz
Milestone 2014_04_ISR+Imaging	1465	23 Apr 08:35 Problems with Faraday acquisition system	ISR+Imaging		Acquisition system	J. Ortiz	new	2014-04-23T05:55:03-05:00	2014-04-23T05:55:03-05:00	Echos were not located at the right height. Acquisition program was restarted.	jortiz
Milestone 2014_04_ISR+Imaging	1464	22 Apr 15:55 Problems with Faraday acquisition system	ISR+Imaging		Acquisition system	imanay	new	2014-04-22T13:55:27-05:00	2014-04-22T13:55:27-05:00	Echos were not located at the right height. Acquisition program was restarted.	imanay
Milestone 2014_04_ISR+Imaging	1463	22 Apr 15:00 spark gaps adjusment	ISR+Imaging		Spark Gaps	imanay	new	2014-04-22T13:46:58-05:00	2014-04-22T13:46:58-05:00		imanay
Milestone 2014_04_ISR+Imaging	1462	22 Apr 14:10 Drop at the channel A of Faraday experiment	ISR+Imaging		Transmitters	imanay	new	2014-04-22T13:46:03-05:00	2014-04-22T14:39:07-05:00	Due to problems with RF input of the transmisor.	imanay
Milestone 2014_04_ISR+Imaging	1461	22 Apr 12:42 Starts campaign	ISR		Start experiment	ryanque	new	2014-04-22T10:26:33-05:00	2014-04-22T10:26:33-05:00	Problems with the Faraday mode have been solved.	ryanque
Milestone 2014_04_ISR+Imaging	1460	21 Apr 02:22 Antenna VSWR	ISR		Antennas	ryanque	new	2014-04-21T11:37:34-05:00	2014-04-21T11:37:34-05:00	"WUP  1.02 - 49.93 MHz 1.00
WDW  1.03
NDW  1.09 - 50.005 MHz 1.00
NUP  1.10 - 50.005 MHz 1.05
EUP  1.03 - 49.51 MHz 1.02
EDW  1.03 - 49.998 MHz 1.02
SDW  1.08 - 49.98 MHz 1.04
SUP  1.02"	ryanque
Milestone 2014_04_ISR+Imaging	1459	21 Apr 14:19 Log created for 2014_04 ISR+Imaging	ISR		Start experiment	ryanque	new	2014-04-21T11:31:48-05:00	2014-04-21T11:31:48-05:00	The log has been created for 2014_04 ISR+Imaging.	ryanque
Milestone 2014_03 ISCOD HLStormtime	1458	09 Apr 13:30 Experiment data to PUMA	ISR		General	I. Manay	new	2014-04-09T10:58:02-05:00	2014-04-09T11:03:23-05:00	"The experiment data were uploaded to the storage system (PUMA)

Faraday experiment:
-------------------
684 files
35.3 GB

EW_Drift experiment:
-------------------
1723 files
122 GB"	imanay
Milestone 2014_03 ISCOD HLStormtime	1457	04 Abr 12:35 End of campaign	ISR		End experiment	P. Condor	new	2014-04-04T09:58:05-05:00	2014-04-04T09:58:05-05:00	"End of campaign.
Put pictures of rtis, spectros, noise, power and results."	pcondor
Milestone 2014_03 ISCOD HLStormtime	1455	04 Apr 07:49 Re-starting acquisition of the Faraday experiment	ISR		Acquisition system	I. Manay	new	2014-04-04T05:08:56-05:00	2014-04-04T05:08:56-05:00	The PC of the Faraday experiment re-started itself at 07:49. The acquisition was re-started at 07:52	imanay
Milestone 2014_03 ISCOD HLStormtime	1454	04 Apr 07:05 Transmitter Power Measurements	ISR		Transmitters		new	2014-04-04T04:20:19-05:00	2014-04-04T04:20:19-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +1.5 dBm/ +4.8 dBm
Tx4 +2.0 dBm
Line voltage and power: 3950 VAC, 300 KW 
01:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +1.5 dBm/ +4.8 dBm
Tx4 +2.0 dBm
Line voltage and power: 3950 VAC, 300 KW 
02:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +2.0 dBm/ +5.1 dBm
Tx4 +2.1 dBm
Line voltage and power: 4000 VAC, 310 KW 
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +2.0 dBm/ +5.1 dBm
Tx4 +2.1 dBm
Line voltage and power: 4000 VAC, 310 KW 
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +2.0 dBm/ +5.1 dBm
Tx4 +2.1 dBm
Line voltage and power: 4000 VAC, 310 KW 
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.3 dBm
Tx2 +2.0 dBm/ +5.1 dBm
Tx4 +2.1 dBm
Line voltage and power: 4000 VAC, 310 KW 
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +1.3 dBm/ +4.5 dBm
Tx4 +1.8 dBm
Line voltage and power: 3950 VAC, 295 KW 
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +1.3 dBm/ +4.5 dBm
Tx4 +1.8 dBm
Line voltage and power: 3950 VAC, 295 KW "	vquesada
Milestone 2014_03 ISCOD HLStormtime	1453	04 Apr 06:55 spark gaps adjustment	ISR		Spark Gaps	J. Lavado	new	2014-04-04T04:08:36-05:00	2014-04-04T04:08:36-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1452	04 Apr 02:40 spark gaps adjustment	ISR		Spark Gaps	J. Lavado	new	2014-04-03T23:58:56-05:00	2014-04-03T23:58:56-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1451	03 Apr 23:59 plots of experiments	ISR		Plot	I. Manay	new	2014-04-03T21:24:50-05:00	2014-04-03T21:24:50-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1450	03 Apr 23:57 Re-starting acquisition of the Faraday experiment	ISR		Acquisition system	I. Manay	new	2014-04-03T21:24:41-05:00	2014-04-03T21:24:41-05:00	The acquisition re-started itself at 23:57.	imanay
Milestone 2014_03 ISCOD HLStormtime	1449	03 Apr 23:30 Re-starting acquisition of the Faraday experiment	ISR		Acquisition system	I. Manay	new	2014-04-03T21:21:47-05:00	2014-04-03T21:30:39-05:00	The PC of the Faraday experiment re-started itself at 23:26. The acquisition was re-started at 23:30.	imanay
Milestone 2014_03 ISCOD HLStormtime	1448	04 Apr 23:50 Transmitter Power Measurements	ISR		Transmitters		new	2014-04-03T21:02:44-05:00	2014-04-03T21:02:44-05:00	"20:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.9 dBm/ +5.0 dBm
Tx4 +2.0 dBm
Line voltage and power: 4000 VAC, 310 KW 
21:00 TX Power sample (-70 dB coupling)
Tx1 +6.6 dBm
Tx2 +1.9 dBm/ +5.0 dBm
Tx4 +2.0 dBm
Line voltage and power: 4000 VAC, 310 KW 
22:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +1.5 dBm/ +4.8 dBm
Tx4 +2.0 dBm
Line voltage and power: 3950 VAC, 300 KW 
23:00 TX Power sample (-70 dB coupling)
Tx1 +6.4 dBm
Tx2 +1.5 dBm/ +4.8 dBm
Tx4 +2.0 dBm
Line voltage and power: 3950 VAC, 300 KW "	vquesada
Milestone 2014_03 ISCOD HLStormtime	1447	03 Apr 22:20 spark gaps adjustment	ISR		Spark Gaps	I. Manay	new	2014-04-03T20:04:35-05:00	2014-04-03T21:09:19-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1446	03 Apr 20:00 Transmitter Power mesearuments	ISR		Transmitters		new	2014-04-03T16:30:07-05:00	2014-04-03T16:43:22-05:00	"04/03/2014
08:00 TX Power sample (-70 dB coupling)
 1 +6.2 dBm
 2 +1.4 dBm/ +4.5 dBm
 4 +2.0 dBm
 Voltage line and power: 3900 VAC, 290 KW 
09:00 TX Power sample (-70 dB coupling)
 1 +6.2 dBm
 2 +1.4 dBm/ +4.5 dBm
 4 +1.8 dBm
 Voltage line and power: 3900 VAC, 290 KW 
10:00 TX Power sample (-70 dB coupling)
 1 +6.2 dBm
 2 +1.6 dBm/ +4.6 dBm
 4 +1.8 dBm
 Voltage line and power: 3950 VAC, 300 KW 
11:00 TX Power sample (-70 dB coupling)
 1 +6.1 dBm
 2 +1.2 dBm/ +4.3 dBm
 4 +1.8 dBm
 Voltage line and power: 3900 VAC, 290 KW 
12:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +1.8 dBm/ +4.9 dBm
 4 +2.1 dBm
 Voltage line and power: 3900 VAC, 290 KW 
13:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +1.8 dBm/ +4.9 dBm
 4 +2.1 dBm
 Voltage line and power: 4000 VAC, 300 KW 
14:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +1.2 dBm/ +4.4 dBm
 4 +1.7 dBm
 Voltage line and power: 3850 VAC, 290 KW 
15:00 TX Power sample (-70 dB coupling)
 1 +5.6 dBm
 2 +1.0 dBm/ +4.0 dBm
 4 +1.6 dBm
 Voltage line and power: 3850 VAC, 290 KW 
16:00 TX Power sample (-70 dB coupling)
 1 +5.5 dBm
 2 +1.4 dBm/ +4.2 dBm
 4 +1.8 dBm
 Voltage line and power: 3900 VAC, 290 KW 
17:00 TX Power sample (-70 dB coupling)
 1 +5.5 dBm
 2 +1.3 dBm/ +4.2 dBm
 4 +1.8 dBm
 Voltage line and power: 3900 VAC, 290 KW 
18:00 TX Power sample (-70 dB coupling)
 1 +6.2 dBm
 2 +1.2 dBm/ +4.4 dBm
 4 +2.0 dBm
 Voltage line and power: 3900 VAC, 290 KW 
19:00 TX Power sample (-70 dB coupling)
 1 +6.2 dBm
 2 +1.8 dBm/ +4.8 dBm
 4 +2.0 dBm
 Voltage line and power: 3950 VAC, 300 KW 




"	rtadeo
Milestone 2014_03 ISCOD HLStormtime	1445	03 Apr 18:10 Calibration of ATRs and TRs	ISR		General	dsuarez	new	2014-04-03T15:45:14-05:00	2014-04-03T15:45:14-05:00		dsuarez
Milestone 2014_03 ISCOD HLStormtime	1444	03 Apr 17:03 IDL program is hanged	ISR		Process/Analysis Program	dsuarez	new	2014-04-03T15:44:46-05:00	2014-04-03T15:45:33-05:00	The IDL program had to be finished,then the processing program was restarted	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1443	03 Apr 15:09 Calibration of ATRs and TRs	ISR		General	dsuarez	new	2014-04-03T15:36:32-05:00	2014-04-03T15:36:32-05:00		dsuarez
Milestone 2014_03 ISCOD HLStormtime	1442	03 Apr 11:53 Calibration of ATRs and TRs	ISR		General	dsuarez	new	2014-04-03T15:36:05-05:00	2014-04-03T15:36:05-05:00		dsuarez
Milestone 2014_03 ISCOD HLStormtime	1441	03 Apr 08:41 Calibration of ATRs and TRs	ISR		General	dsuarez	new	2014-04-03T15:35:29-05:00	2014-04-03T15:35:29-05:00		dsuarez
Milestone 2014_03 ISCOD HLStormtime	1440	02 Abr 07:50 Lose synchronization in the Faraday aquisition system	ISR		Acquisition system		new	2014-04-03T05:19:04-05:00	2014-04-03T05:19:04-05:00		jverastegui
Milestone 2014_03 ISCOD HLStormtime	1439	03 Apr 07:05 Crowbar by voltage drop	ISR		Transmitters	jverastegui	new	2014-04-03T04:28:09-05:00	2014-04-03T04:28:09-05:00		jverastegui
Milestone 2014_03 ISCOD HLStormtime	1437	03 Apr 07:10 Transmitter Power measurements	ISR		Transmitters		new	2014-04-03T04:24:40-05:00	2014-04-03T04:24:40-05:00	"00:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +2.1 dBm
Line voltage and power: 3900 VAC, 300 KW 
01:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +1.7 dBm/ +4.9 dBm
TX4 +2.1 dBm
Line voltage and power: 3900 VAC, 300 KW 
07:07 Crowbar by voltage drop.
02:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +2.1 dBm
Line voltage and power: 3900 VAC, 300 KW 
03:00 TX Power sample (-70 dB coupling)
Tx1 +6.1 dBm
Tx2 +1.7 dBm/ +4.9 dBm
Tx4 +2.1 dBm
Line voltage and power: 3900 VAC, 300 KW 
04:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +1.8 dBm/ +5.0 dBm
Tx4 +2.1 dBm
Line voltage and power: 3950 VAC, 300 KW 
05:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +1.8 dBm/ +5.0 dBm
Tx4 +2.1 dBm
Line voltage and power: 3950 VAC, 300 KW 
06:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +1.8 dBm/ +5.0 dBm
Tx4 +2.1 dBm
Line voltage and power: 3950 VAC, 300 KW 
07:00 TX Power sample (-70 dB coupling)
Tx1 +6.2 dBm
Tx2 +1.8 dBm/ +5.0 dBm
Tx4 +2.1 dBm
Line voltage and power: 3950 VAC, 300 KW "	vquesada
Milestone 2014_03 ISCOD HLStormtime	1436	03 Apr 01:45 Calibration of ATRs and TRs	ISR		Antennas	jverastegui	new	2014-04-03T00:10:07-05:00	2014-04-03T00:10:07-05:00		jverastegui
Milestone 2014_03 ISCOD HLStormtime	1435	03 Apr 00:00 Figures of RTI, noise, spectras, etc	ISR		Process/Analysis Program	jverastegui	new	2014-04-02T22:36:55-05:00	2014-04-02T22:36:55-05:00		jverastegui
Milestone 2014_03 ISCOD HLStormtime	1434	02 Apr 21:55 Calibration of ATRs and TRs	ISR		Antennas	jverastegui	new	2014-04-02T22:33:45-05:00	2014-04-02T22:35:09-05:00		jverastegui
Milestone 2014_03 ISCOD HLStormtime	1433	03 Apr 00:12 Transmitter Power measurements	ISR		Transmitters		new	2014-04-02T21:25:22-05:00	2014-04-02T21:25:22-05:00	"20:00 TX Power sample (-70 dB coupling)
1 +6.3 dBm
2 +2.3 dBm/ +5.1 dBm
4 +2.5 dBm
Voltage line and power: 4000 VAC, 310 KW 
21:00 TX Power sample (-70 dB coupling)
1 +6.3 dBm
2 +2.3 dBm/ +5.1 dBm
4 +2.5 dBm
Voltage line and power: 4000 VAC, 310 KW 
22:00 TX Power sample (-70 dB coupling)
1 +6.3 dBm
2 +2.3 dBm/ +5.1 dBm
4 +2.5 dBm
Voltage line and power: 4000 VAC, 310 KW 
23:00 TX Power sample (-70 dB coupling)
1 +6.1 dBm
2 +1.7 dBm/ +4.9 dBm
4 +2.0 dBm
Voltage line and power: 3900 VAC, 300 KW 
"	vquesada
Milestone 2014_03 ISCOD HLStormtime	1432	02 Apr 19:50 Transmitter Power measurements	ISR		Transmitters		new	2014-04-02T16:58:30-05:00	2014-04-03T16:42:26-05:00	"09:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.7 dBm
Voltage line and power: 3900 VAC, 290 KW 
10:00 TX Power sample (-70 dB coupling)
1 +5.0 dBm
2 +1.2 dBm/ +4.4 dBm
4 +1.4 dBm
Voltage line and power: 3850 VAC, 270 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.1 dBm
2 +1.2 dBm/ +4.5 dBm
4 +1.4 dBm
Voltage line and power: 3860 VAC, 270 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +1.8 dBm/ +5.0 dBm
4 +2.0 dBm
Voltage line and power: 3950 VAC, 300 KW

14:00 TX Power sample (-70 dB coupling)
1 +5.2 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.6 dBm
Voltage line and power: 3850 VAC, 280 KW 
15:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.6 dBm
Voltage line and power: 3850 VAC, 290 KW 
16:00 TX Power sample (-70 dB coupling)
1 +5.7 dBm
2 +1.5 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3890 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.5 dBm
2 +1.5 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3890 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +1.6 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3900 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
1 +6.0 dBm
2 +1.8 dBm/ +5.0 dBm
4 +2.0 dBm
Voltage line and power: 3920 VAC, 300 KW"	ryaya
Milestone 2014_03 ISCOD HLStormtime	1431	02 Apr 18:35 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-04-02T15:49:01-05:00	2014-04-02T15:49:50-05:00	Calibration of ATRs and TRs	jortiz
Milestone 2014_03 ISCOD HLStormtime	1430	02 Apr 15:22 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-04-02T12:50:54-05:00	2014-04-02T14:07:32-05:00	Calibration of ATRs and TRs	jortiz
Milestone 2014_03 ISCOD HLStormtime	1429	02 Apr 15:20 Signal Chain Restart	ISR		Process/Analysis Program	J. Ortiz	new	2014-04-02T12:50:39-05:00	2014-04-02T14:07:17-05:00	The signal chain processing program stopped due to an error with an invalid value and was restarted.	jortiz
Milestone 2014_03 ISCOD HLStormtime	1428	02 Apr 14:40 Power adjustment in Tx1 due to AC Line variation	ISR		Transmitters	J. Ortiz	new	2014-04-02T12:07:14-05:00	2014-04-02T14:07:05-05:00	Power adjustment Tx1 due to AC Line variation	jortiz
Milestone 2014_03 ISCOD HLStormtime	1427	02 Apr 13:34 Posible Solar Flare Interference	ISR		Physical Phenomena	J. Ortiz	new	2014-04-02T11:51:12-05:00	2014-04-02T14:06:51-05:00	"Noise across all heights was detected at 13:34. Possible suspect is small solar flare (attached). The noise at 09:00 also seems to correspond to the larger flare occurring at the same time. 

"	jortiz
Milestone 2014_03 ISCOD HLStormtime	1426	02 Apr 12:22 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-04-02T09:43:03-05:00	2014-04-02T14:06:21-05:00	 Calibration of ATRs and TRs	jortiz
Milestone 2014_03 ISCOD HLStormtime	1425	02 Apr 12:01 Drop in Tx line	ISR		Transmitters	J. Ortiz	new	2014-04-02T09:21:11-05:00	2014-04-02T14:06:07-05:00	Tx line dropped at 12:01 pm. A previous drop was detected at 11:58am.	jortiz
Milestone 2014_03 ISCOD HLStormtime	1424	02 Apr 10:01 Signal Chain restart	ISR		Process/Analysis Program	J. Ortiz	new	2014-04-02T07:18:11-05:00	2014-04-02T14:05:48-05:00	Signal Chain was restarted	jortiz
Milestone 2014_03 ISCOD HLStormtime	1423	02 Apr 08:25 Signal Chain stop	ISR		Process/Analysis Program	J. Ortiz	new	2014-04-02T07:17:21-05:00	2014-04-02T14:04:34-05:00	The signal chain processing program stopped due to an error in threading.	jortiz
Milestone 2014_03 ISCOD HLStormtime	1422	02 Abr 09:03 Calibration of ATRs and TRs	ISR		Antennas	J. Ortiz	new	2014-04-02T06:20:14-05:00	2014-04-02T12:09:19-05:00	Calibration of ATRs and TRs	jortiz
Milestone 2014_03 ISCOD HLStormtime	1421	02 Apr 00:00 Figures of RTI, noise, spectras, etc	ISR		Process/Analysis Program	P. Condor	new	2014-04-02T04:50:29-05:00	2014-04-02T14:03:59-05:00	Figures of RTI, noise, spectras, etc	pcondor
Milestone 2014_03 ISCOD HLStormtime	1420	02 Apr 05:18 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-04-02T04:48:56-05:00	2014-04-02T14:03:43-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_03 ISCOD HLStormtime	1419	02 Apr 05:00 ChA is recovered after fall of TX1	ISR		Reception	P. Condor	new	2014-04-02T04:48:05-05:00	2014-04-02T14:03:27-05:00	ChA is recovered after fall of TX1	pcondor
Milestone 2014_03 ISCOD HLStormtime	1418	02 Abr 04:40 Fall Tx1 by variation Line AC	ISR		Transmitters	P. Condor	new	2014-04-02T04:45:33-05:00	2014-04-02T04:45:33-05:00	Fall Tx1 by variation Line AC	pcondor
Milestone 2014_03 ISCOD HLStormtime	1417	02 Apr 01:04 Calibration of ATRs and TRs	ISR		Antennas	A. Coronado	new	2014-04-02T04:42:33-05:00	2014-04-02T14:02:58-05:00	Calibration of ATRs and TRs	pcondor
Milestone 2014_03 ISCOD HLStormtime	1416	01 Apr 22:22 Change Tr at ChA	ISR		Reception	P. Condor	new	2014-04-02T04:41:26-05:00	2014-04-02T14:02:41-05:00	"Change Tr at ChA, after put back the same TR at ChA. ChA is attenuated 2 db.
The current attenuation of every channel:

EW_drift:
A : 2dB
B : 0dB
C : 1dB
D : 0dB

Faraday:
A : 10dB
B :  8dB"	pcondor
Milestone 2014_03 ISCOD HLStormtime	1415	01 Mar 08:00 Transmitter Power mesearuments	ISR		Transmitters		new	2014-04-02T04:39:56-05:00	2014-04-02T04:39:56-05:00	"Date:04/01/2014
20:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +2.0 dBm/ +5.4 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW 

21:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +2.0 dBm/ +5.4 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW 

22:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +2.0 dBm/ +5.4 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW 

23:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW 
Date:04/02/2014
00:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +2.1 dBm
 Voltage line and power: 4000 VAC, 300 KW 
01:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +2.1 dBm
 Voltage line and power: 4000 VAC, 300 KW 
02:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +2.1 dBm
 Voltage line and power: 4000 VAC, 300 KW 
03:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +2.1 dBm
 Voltage line and power: 3900 VAC, 300 KW 
04:00 TX Power sample (-70 dB coupling)
 1 +5 dBm
 2 +1.4 dBm/ +4.2 dBm
 4 +1.8 dBm
 Voltage line and power: 3900 VAC, 300 KW 
05:00 TX Power sample (-70 dB coupling)
 1 +5.0 dBm
 2 +1.4 dBm/ +4.2 dBm
 4 +1.8 dBm
 Voltage line and power: 3800 VAC, 300 KW 
06:00 TX Power sample (-70 dB coupling)
 1 +5.0 dBm
 2 +1.4 dBm/ +4.2 dBm
 4 +1.8 dBm
 Voltage line and power: 3800 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
 1 +6.0 dBm
 2 +2.5 dBm/ +5.2 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW 
 

"	rtadeo
Milestone 2014_03 ISCOD HLStormtime	1414	01 Apr 21:35 ChA is attenuated at 1 db	ISR		Reception	P. Condor	new	2014-04-02T04:37:50-05:00	2014-04-04T09:47:32-05:00	ChA is attenuated at 1 db	pcondor
Milestone 2014_03 ISCOD HLStormtime	1413	01 Apr 21:25 ChA is attenuated at 1 db	ISR		Reception	P. Condor	new	2014-04-02T04:37:09-05:00	2014-04-02T14:02:10-05:00	ChA is attenuated at 1 db	pcondor
Milestone 2014_03 ISCOD HLStormtime	1412	01 Apr 21:21 Difference in Noise of Ch A and B is more of 2 db	ISR		Reception	P.Condor	new	2014-04-02T04:34:42-05:00	2014-04-02T14:01:57-05:00	 Difference in Noise of Ch A and B is more of 2 db 	pcondor
Milestone 2014_03 ISCOD HLStormtime	1411	01 Apr 20:41 Calibration ATrs and Trs	ISR		Antennas	A. Coronado	new	2014-04-02T04:29:52-05:00	2014-04-02T14:01:42-05:00	Calibration ATrs and Trs	pcondor
Milestone 2014_03 ISCOD HLStormtime	1410	01 Apr 19:50 Transmitter Power measurements	ISR		Transmitters		new	2014-04-01T17:08:53-05:00	2014-04-02T14:01:13-05:00	"09:00 TX Power sample (-70 dB coupling)
1 +5.3 dBm
2 +1.6 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3950 VAC, 300 KW 
10:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.6 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3900 VAC, 280 KW 
11:00 TX Power sample (-70 dB coupling)
1 +5.0 dBm
2 +1.2 dBm/ +4.4 dBm
4 +1.3 dBm
Voltage line and power: 3820 VAC, 270 KW
12:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.6 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3920 VAC, 290 KW
 
14:00 TX Power sample (-70 dB coupling)
1 +5.0 dBm
2 +1.2 dBm/ +4.4 dBm
4 +1.4 dBm
Voltage line and power: 3860 VAC, 280 KW 
15:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.6 dBm
Voltage line and power: 3900 VAC, 290 KW 
16:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +1.4 dBm/ +4.8 dBm
4 +1.6 dBm
Voltage line and power: 3900 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
1 +5.6 dBm
2 +1.6 dBm/ +4.8 dBm
4 +1.8 dBm
Voltage line and power: 3950 VAC, 290 KW
18:00 TX Power sample (-70 dB coupling)
1 +5.4 dBm
2 +1.8 dBm/ +5.0 dBm
4 +2.0 dBm
Voltage line and power: 3950 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
1 +6.0 dBm
2 +2 dBm/ +5.4 dBm
4 +2.2 dBm
Voltage line and power: 4000 VAC, 300 KW
"	ryaya
Milestone 2014_03 ISCOD HLStormtime	1409	01 Apr 19:35 Re-starting the pc of ew_drift experiment	ISR		Acquisition system	I. Manay	new	2014-04-01T16:55:51-05:00	2014-04-01T16:55:51-05:00	The PC of the acquisition system was re-started because of problems with the acquisition program.	imanay
Milestone 2014_03 ISCOD HLStormtime	1408	01 Apr 16:20 Spark Gaps adjustment	ISR		Spark Gaps	I. Manay	new	2014-04-01T15:30:19-05:00	2014-04-01T15:30:19-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1407	01 Apr 13:25 Spark Gaps adjustment	ISR		Spark Gaps	I. Manay	new	2014-04-01T10:48:41-05:00	2014-04-01T10:48:41-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1406	01 Apr 09:25 Spark gap adjusment	ISR		Spark Gaps	I. Manay	new	2014-04-01T09:17:53-05:00	2014-04-01T09:17:53-05:00	Drop at the reception channels of Faraday due to spark gap problems.	imanay
Milestone 2014_03 ISCOD HLStormtime	1405	01 Apr 08:45 Spark Gaps adjustment	ISR		Spark Gaps	I. Manay	new	2014-04-01T09:01:39-05:00	2014-04-01T09:01:39-05:00		imanay
Milestone 2014_03 ISCOD HLStormtime	1404	01 Apr 07:13 DP_Faraday  Acquisition System stopped	ISR		Acquisition system	AValdez	new	2014-04-01T04:51:10-05:00	2014-04-01T08:59:59-05:00	"Faraday Acquisition System was restarted
"	avaldez
Milestone 2014_03 ISCOD HLStormtime	1403	31 Mar 20:00 Transmitter Power mesearuments	ISR	Others	Transmitters		new	2014-04-01T04:14:24-05:00	2014-04-01T04:14:24-05:00	"Date:03/31/2014
20:00 TX Power sample (-70 dB coupling)
 1 +5.9 dBm
 2 +2.1 dBm/ +5.3 dBm
 4 +2.3 dBm
 Voltage line and power: 4000 VAC, 300 KW 
21:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.5 dBm/ +5.4 dBm
 4 +2.3 dBm
 Voltage line and power: 4000 VAC, 300 KW 
22:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.5 dBm/ +5.4 dBm
 4 +2.3 dBm
 Voltage line and power: 4000 VAC, 300 KW
23:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.5 dBm/ +5.4 dBm
 4 +2.3 dBm
 Voltage line and power: 4000 VAC, 300 KW
Date:04/01/2014 
00:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.o dBm/ +5.4 dBm
 4 +2.3 dBm
 Voltage line and power: 4000 VAC, 300 KW 
01:00 TX Power sample (-70 dB coupling)
 1 +5.9 dBm
 2 +2.0 dBm/ +5.2 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW 
02:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.0 dBm/ +5.2 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW
03:00 TX Power sample (-70 dB coupling)
 1 +5.8 dBm
 2 +2.0 dBm/ +5.2 dBm
 4 +2.2 dBm
 Voltage line and power: 4000 VAC, 300 KW
04:00 TX Power sample (-70 dB coupling)
 1 +5.4 dBm
 2 +1.8 dBm/ +4.8 dBm
 4 +2.0 dBm
 Voltage line and power: 3800 VAC, 300 KW
05:00 TX Power sample (-70 dB coupling)
 1 +5.4 dBm
 2 +1.9 dBm/ +4.8 dBm
 4 +2.0 dBm
 Voltage line and power: 4000 VAC, 300 KW
06:00 TX Power sample (-70 dB coupling)
 1 +5.4 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +1.8 dBm
 Voltage line and power: 3900 VAC, 300 KW
07:00 TX Power sample (-70 dB coupling)
 1 +5.4 dBm
 2 +2.0 dBm/ +5.0 dBm
 4 +2.1 dBm
 Voltage line and power: 3950 VAC, 300 KW
"	rtadeo
Milestone 2014_03 ISCOD HLStormtime	1402	01 Apr 06:20 DP_Faraday  Acquisition System stopped	ISR		Acquisition system	AValdez	new	2014-04-01T04:06:58-05:00	2014-04-01T08:59:02-05:00	"PC-Faraday stopped acquisition.
6:26 am Acquisition system was restarted.
"	avaldez
Milestone 2014_03 ISCOD HLStormtime	1401	01 Apr 05:19 Spark Gaps adjustment	ISR		Spark Gaps	AValdez	new	2014-04-01T02:40:00-05:00	2014-04-01T08:58:36-05:00		avaldez
Milestone 2014_03 ISCOD HLStormtime	1400	01 Apr 01:11 Spark Gaps adjustment	ISR		Spark Gaps	AValdez	new	2014-04-01T02:38:47-05:00	2014-04-01T08:58:15-05:00		avaldez
Milestone 2014_03 ISCOD HLStormtime	1399	31 Mar 23:04 Power Amplifier 2 fall	ISR		Transmitters	AValdez	new	2014-03-31T21:03:27-05:00	2014-04-01T05:49:54-05:00	There was a problem with source screen. The power amplifier 2 was restarted.	avaldez
Milestone 2014_03 ISCOD HLStormtime	1398	31 Mar 22:51 Power Amplifier 2 fall	ISR		Transmitters	AValdez	new	2014-03-31T20:59:34-05:00	2014-04-01T08:57:03-05:00	There was a problem with source screen. The power amplifier 2 was restarted.	avaldez
Milestone 2014_03 ISCOD HLStormtime	1397	31 Mar 21:07 Spark Gaps adjustment	ISR		Spark Gaps	AValdez	new	2014-03-31T20:48:00-05:00	2014-04-01T08:56:38-05:00		avaldez
Milestone 2014_03 ISCOD HLStormtime	1396	31 Mar 19:23 Power Amplifier 1 had problems	ISR		Transmitters	dsuarez	new	2014-03-31T20:36:52-05:00	2014-04-01T08:56:12-05:00	19:26 Power Amplifier was restarted.	avaldez
Milestone 2014_03 ISCOD HLStormtime	1395	31 Mar 17:55 IDL program is hung	ISR		Process/Analysis Program	dsuarez	new	2014-03-31T20:18:17-05:00	2014-04-01T08:54:48-05:00	The program had to be finished,then the processing program was restarted.	avaldez
Milestone 2014_03 ISCOD HLStormtime	1394	31 Mar 19:50 Transmitter Power measurements	ISR		Transmitters		new	2014-03-31T17:13:01-05:00	2014-03-31T17:13:01-05:00	"17:00 Transmitters on
18:00 TX    Power sample (-70 dB coupling)
       1     +5.6 dBm
       2     +1.6 dBm/ +4.8 dBm
       4     +1.6 dBm
       Voltage line and power: 3900 VAC, 280 KW   
19:00 TX    Power sample (-70 dB coupling)
       1     +6.0 dBm
       2     +2.2 dBm/ +5.2 dBm
       4     +2.4 dBm
       Voltage line and power: 4000 VAC, 300 KW   "	ryaya
Milestone 2014_03 ISCOD HLStormtime	1393	31 Mar 17:55 Faraday's Plots	ISR		Start experiment	dsuarez	new	2014-03-31T16:55:23-05:00	2014-04-01T08:53:34-05:00	Signal Chain software is sending the Spectras and RTIs plot to real-time web page of Jicamarca	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1392	31 Mar 17:50 Attenuation on Faraday's Channels	ISR		Start experiment	ivan manay	new	2014-03-31T16:52:14-05:00	2014-04-02T14:00:01-05:00	"On Faraday, the attenuation of Channel A and B are fixed to 10dB and 8dB respectively.

The attenuation of each channel was set as:
EW_Drift:
A : 0 dB
B : 0 dB
C : 1 dB
D : 0 dB
Faraday:
A : 10 dB
B : 8 dB

Every pre-amplifier has a gain of 15 dB."	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1391	31 Mar 17:40 Amplification Stage on Faraday	ISR		Reception	ivan manay	new	2014-03-31T16:48:04-05:00	2014-04-01T08:52:38-05:00	Amplification Stage (-15dB) is put out of Channels A and B	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1390	31 Mar 17:34 UE Channel C	ISR		General	ivan manay	new	2014-03-31T16:44:54-05:00	2014-04-01T08:52:12-05:00	The experiment is restarted after that problems were solved on UE of Channel C	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1389	31 Mar 17:15 Start Experiment	ISR		Start experiment	ivan manay	new	2014-03-31T16:34:02-05:00	2014-04-02T13:58:23-05:00	At the beginning there were problems on Channel C of EW-Drifts and Noise Estimation on Faraday, those problem were fixed.	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1388	31 Mar 17:00 Antenna Setup	ISR		Antennas	walter rojas	new	2014-03-31T16:08:38-05:00	2014-04-01T08:51:03-05:00	"VSWR Measurements:
W_up = 1.03 
W_dw = 1.02
N_up = 1.06 (central frequency is fixed to 50.2 MHz)
N_dw = 1.10
E_up = 1.03
E_dw = 1.03
S_up = 1.03
S_dw = 1.09 (central frequency is fixed to 49.9 MHz)"	dsuarez
Milestone 2014_03 ISCOD HLStormtime	1387	31 Mar 11:33 Log created ISCOD HLStormtime 31 Mar - 04 Apr	ISR		General	ryanque	new	2014-03-31T08:46:20-05:00	2014-03-31T08:47:03-05:00	Log created	ryanque
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1386	31 Ene 17:50 Copia de datos a PUMA	ISR		General	imanay	new	2014-01-31T18:09:01-05:00	2014-01-31T18:09:01-05:00	"__EW_Drift__:
4658 files.
332 GB.

__Faraday__:
1740 files.
91.6 GB."	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1385	31 Ene 08:00 Fin de experimento	ISR		End experiment	imanay	new	2014-01-31T18:02:40-05:00	2014-01-31T18:02:40-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1384	31 Ene 07:35 Lectura de Potencias.	ISR		Transmitters		new	2014-01-31T08:22:21-05:00	2014-01-31T08:22:21-05:00	"31 de Enero 2014
00:00
Tx1: +6.4 dBm
Tx2: +1.5 dBm/+4.8 dBm 
Tx4: +1. dBm
Voltaje de linea: 4000 Vac, 310 Kw
01:00
Tx1: +6.4 dBm
Tx2: +1.5 dBm/+4.8 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 4000 Vac, 310 Kw
02:00
Tx1: +6.3 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
03:00
Tx1: +6.3 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
04:00
Tx1: +6.3 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
05:00
Tx1: +6.3 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
06:00
Tx1: +6.3 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
07:00
Tx1: +6.3 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
08:00 HV  OFF
08:15 LV  OFF "	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1383	30 Ene 23:59 Plots de experimento	ISR		Plot	M. Inonan	new	2014-01-31T08:09:00-05:00	2014-01-31T08:09:00-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1382	31 Ene 04:05 Calibracion de los ATR's y TR's	ISR		Transmitters	A. Coronado	new	2014-01-31T08:06:58-05:00	2014-01-31T08:06:58-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1381	30 Ene 23:57 Calibracion de los ATR's y TR's	ISR		Start experiment	A. Coronado	new	2014-01-31T08:06:12-05:00	2014-01-31T08:06:12-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1380	30 Ene 23:20 Lectura de Potencias.	ISR		Transmitters		new	2014-01-31T00:06:17-05:00	2014-01-31T00:06:17-05:00	"30 de Enero 2014
20:00
Tx1: +6.3 dBm
Tx2: +1.3 dBm/+4.5 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
21:00
Tx1: +6.3 dBm
Tx2: +1.3 dBm/+4.5 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 310 Kw
22:00
Tx1: +6.4 dBm
Tx2: +1.5 dBm/+4.8 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 4000 Vac, 310 Kw
23:00
Tx1: +6.4 dBm
Tx2: +1.5 dBm/+4.8 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 4000 Vac, 310 Kw"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1379	30 Ene 19:50 Calibracion de ATRs y TRs	ISR		Spark Gaps	imanay	new	2014-01-30T20:37:12-05:00	2014-01-30T20:37:12-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1378	30 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-30T20:31:00-05:00	2014-01-30T20:31:00-05:00	"30 de Enero 2014
 08:00
 Tx1: +6.0 dBm
 Tx2: +1.4 dBm/+4.4 dBm 
 Tx4: +1.5 dBm
 09:00 
 Tx1: +5.8 dBm
 Tx2: +1.1 dBm/+4.2 dBm 
 Tx4: +1.2 dBm
 Voltaje de linea:3850Vac, 265Kw
 10:00
 Tx1: +5.6 dBm
 Tx2: +0.8 dBm/+3.9 dBm 
 Tx4: +1.0 dBm
 Voltaje de linea:3800Vac, 250Kw
 11:00
 Tx1: +6.0 dBm
 Tx2: +1.0 dBm/+4.1 dBm 
 Tx4: +1.0 dBm
 Voltaje de linea:3850Vac, 250Kw
 12:00
 Tx1: +6.1 dBm
 Tx2: +1.4 dBm/+4.5 dBm 
 Tx4: +1.5 dBm
 13:00
 Tx1: +6.1 dBm
 Tx2: +1.4 dBm/+4.5 dBm 
 Tx4: +1.5 dBm
 14:00
 Tx1: +5.6 dBm
 Tx2: +0.7 dBm/+3.6 dBm 
 Tx4: +0.9 dBm
 Voltaje de linea:3800Vac, 285Kw
 15:00
 Tx1: +5.6 dBm
 Tx2: +0.7 dBm/+3.6 dBm 
 Tx4: +0.9 dBm
 16:00
 Tx1: +5.6 dBm
 Tx2: +0.8 dBm/+3.8 dBm 
 Tx4: +0.8 dBm
 Voltaje de linea:3820Vac, 285Kw
 17:00
 Tx1: +6.0 dBm
 Tx2: +1.1 dBm/+4.2 dBm 
 Tx4: +1.2 dBm
 18:00
 Tx1: +6.0 dBm
 Tx2: +1.1 dBm/+4.2 dBm 
 Tx4: +1.2 dBm
 Voltaje de linea:3890Vac, 290Kw
 19:00
 Tx1: +6.2 dBm
 Tx2: +1.5 dBm/+4.6 dBm 
 Tx4: +1.6 dBm
"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1376	30 Ene 17:00 Reinicio de procesamiento de EW_drift:IDL	ISR		Process/Analysis Program	imanay	new	2014-01-30T18:08:58-05:00	2014-01-30T18:08:58-05:00	Se cuelga programa de monitoreo de experimento EW_drift. Se re-inicia IDL.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1375	30 Ene 16:08 Calibracion de ATRs y TRs	ISR		Spark Gaps	abelleza	new	2014-01-30T17:05:38-05:00	2014-01-30T17:05:38-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1374	30 Ene 11:58 Calibracion de ATRs y TRs	ISR		Spark Gaps	abelleza	new	2014-01-30T12:51:15-05:00	2014-01-30T13:13:48-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1373	30 Ene 11:00 Reinicio de IDL (EW_drift)	ISR		Process/Analysis Program	imanay	new	2014-01-30T12:24:29-05:00	2014-01-30T12:24:29-05:00	Se cuelga programa de monitoreo de experimento EW_drift. Se reinicia IDL	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1372	30 Ene 10:35 Reinicio pc de 3 monitores	ISR		Plot	imanay	new	2014-01-30T11:27:22-05:00	2014-01-30T11:27:22-05:00	Debido a continuos cortes de los programas de procesamiento se reinicia la PC de 3 monitores.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1371	30 Ene 07:20 Se congela el Ploteo de Grafico FARADAY DP	ISR	Others	Process/Analysis Program	AValdez	new	2014-01-30T08:21:32-05:00	2014-01-30T09:09:24-05:00	El programa de procesamiento Signal Chain deja de actualizar las imagenes Spectra y RTI, se cierra la aplicacion y se vuelve a ejecutar el programa.	avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1370	30 Ene 07:05 Lectura de Potencias.	ISR		Transmitters		new	2014-01-30T07:52:14-05:00	2014-01-30T09:11:12-05:00	"30 de Enero 2014
00:00
Tx1: +6.0 dBm
Tx2: +1.3 dBm/+4.4 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 3900 Vac, 300 Kw
01:00
Tx1: +6.0 dBm
Tx2: +1.3 dBm/+4.4 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 3900 Vac, 300 Kw
02:00
Tx1: +6.0 dBm
Tx2: +1.3 dBm/+4.4 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 3900 Vac, 300 Kw
03:00
Tx1: +6.0 dBm
Tx2: +1.3 dBm/+4.4 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 3900 Vac, 300 Kw
04:00
Tx1: +6.0 dBm
Tx2: +1.3 dBm/+4.4 dBm 
Tx4: +1.5 dBm
Voltaje de linea: 3900 Vac, 300 Kw
05:00
Tx1: +6.0 dBm
Tx2: +1.2 dBm/+4.4 dBm 
Tx4: +1.5 dBm
Voltaje de linea: 3900 Vac, 300 Kw
06:00
Tx1: +6.0 dBm
Tx2: +1.2 dBm/+4.4 dBm 
Tx4: +1.5 dBm
Voltaje de linea: 3900 Vac, 300 Kw
07:00
Tx1: +6.2 dBm
Tx2: +1.5 dBm/+4.6 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 3950 Vac, 310 Kw"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1369	30 Ene 04:29 Calibracion de ATRs y TRs	ISR	Others	Spark Gaps	AValdez	new	2014-01-30T07:47:49-05:00	2014-01-30T09:13:05-05:00		avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1368	30 Ene 02:00 Falla programa ewdrifts	ISR	Others	Process/Analysis Program	AValdez	new	2014-01-30T07:25:07-05:00	2014-01-30T12:25:56-05:00	"El programa de procesamiento correspondiente a ewdrift en la pc de 3 monitores  se detiene.
Se cierra IDL y se vuelve a ejecutar el programa."	avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1367	29 Ene 22:30 Falla programa ewdrifts	ISR	Others	Process/Analysis Program	AValdez	new	2014-01-30T07:20:43-05:00	2014-01-30T11:06:45-05:00	"El programa de procesamiento correspondiente a ewdrift en la pc de 3 monitores  se detiene.
Se cierra IDL y se vuelve a ejecutar el programa."	avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1366	29 Ene 23:30 Lectura de Potencias.	ISR		Transmitters		new	2014-01-30T00:14:56-05:00	2014-01-30T11:28:40-05:00	"29 de Enero 2014
20:00
Tx1: +6.2 dBm
Tx2: +1.3 dBm/+4.5 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 3950 Vac, 310 Kw
21:00
Tx1: +6.2 dBm
Tx2: +1.3 dBm/+4.5 dBm 
Tx4: +1.4 dBm
Voltaje de linea: 3950 Vac, 310 Kw
22:00
Tx1: +5.9 dBm
Tx2: +1.2 dBm/+4.4 dBm 
Tx4: +1.3 dBm
Voltaje de linea: 3880 Vac, 295 Kw
23:00
Tx1: +5.9 dBm
Tx2: +1.2 dBm/+4.4 dBm 
Tx4: +1.3 dBm
Voltaje de linea: 3880 Vac, 295 Kw
"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1365	29 Ene 18:40 Se cuelga el programa de EW Drift	ISR		Process/Analysis Program	ryanque	new	2014-01-29T20:26:35-05:00	2014-01-29T20:26:35-05:00	"A las 19:08 se reinicia el program EW Drift
No se incluyo la opcion Overplot"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1364	29 Ene 18:08 Se cuelga la PC de adquisicion de EW Drift	ISR		Acquisition system	ryanque	new	2014-01-29T20:24:47-05:00	2014-01-29T20:24:47-05:00	"Se cuelga la PC de adquisicion de EW Drift.
A las 18:22 se reinicia la adquisicon"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1363	29 Ene 17:58 Se atenua canal C EW Drift	ISR		Reception	ryanque	new	2014-01-29T20:23:11-05:00	2014-01-29T20:23:11-05:00	"Valores finales EW Drift
Canal A  0 dB
Canal B  0 dB
Canal C  2 dB
Canal D  0 dB
"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1362	29 Ene 17:54 Ajuste de ATR's	ISR		Spark Gaps	ryanque	new	2014-01-29T20:21:34-05:00	2014-01-29T20:21:34-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1361	29 Ene 15:48 Ajuste de ATR's	ISR		Spark Gaps	ryanque	new	2014-01-29T20:20:12-05:00	2014-01-29T20:20:12-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1360	29 Ene 12:51 Nivel de canal C y D EW Drift vuelven a lo normal	ISR		Reception	ryanque	new	2014-01-29T20:19:18-05:00	2014-01-29T20:19:18-05:00	A las 12:37 los canales C y D subieron el nivel de ruido. A las 12:51 volvieron a su normalidad. Esto 10 minutos antes ocurrio con A y B y es por el Sol.	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1359	29 Ene 12:26 Nivel de A y B vuelve a lo normal EW Drift	ISR		Start experiment	ryanque	new	2014-01-29T20:13:49-05:00	2014-01-29T20:13:49-05:00	El nivel de ruido ha aumentado desde las 12:16 y ha vuelto a lo normal a las 12:26, debe ser por el Sol.	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1358	29 Ene 12:18 Se ajustan los chisperos	ISR		Spark Gaps	ryanque	new	2014-01-29T20:11:25-05:00	2014-01-29T20:11:25-05:00	Se ajustan los chisperos debido a que se incrementa el ruido en los canales A y B	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1357	29 Ene 09:47 Se reincia el sistema	ISR		Start experiment	ryanque	new	2014-01-29T20:09:17-05:00	2014-01-29T20:09:17-05:00	El sistema se reincia luego del cambio de chisperos	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1356	29 Ene 08:45 Se para la toma para el cambio de chisperos	ISR		Break Experiment	ryanque	new	2014-01-29T20:07:36-05:00	2014-01-29T20:07:36-05:00	Se para la toma para el cambio de chisperos. Esto dura 1 hora.	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1355	29 Ene 19:00 Lectura de Potencias e incidencias TX	ISR		Transmitters		new	2014-01-29T19:59:03-05:00	2014-01-29T19:59:03-05:00	"29 de Enero 2014
08:45 RF OFF, HV OFF Cambio de tungstenos
09:50 HV ON, RF ON
09:53 Falla fuente de pantalla PA 1, falsa alarma de interlock
10:00
Tx1: +5.8 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +0.8 dBm
Voltaje de linea:3780Vac, 280Kw
11:00
Tx1: +5.8 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +0.8 dBm
Voltaje de linea:3760Vac, 280Kw
12:00
Tx1: +6.3 dBm
Tx2: +1.6 dBm/+4.6 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3930Vac, 300Kw
14:00
Tx1: +6.0 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3850Vac, 300Kw
15:00
Tx1: +5.7 dBm
Tx2: +1.0 dBm/+4.0 dBm 
Tx4: +0.8 dBm
Voltaje de linea:3780Vac, 290Kw
17:00
Tx1: +5.9 dBm
Tx2: +1.0 dBm/+4.7 dBm 
Tx4: +0.8 dBm
Voltaje de linea:3860Vac, 300Kw
18:00
Tx1: +6.3 dBm
Tx2: +1.6 dBm/+4.7 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3920Vac, 300Kw
19:00
Tx1: +6.0 dBm
Tx2: +1.2 dBm/+4.3 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3880Vac, 300Kw
"	ryaya
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1354	29 Ene 07:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-29T08:14:20-05:00	2014-01-29T08:14:20-05:00	"
28 de Enero 2014
20:00
 Tx1: +6.4 dBm
 Tx2: +1.8 dBm/+5.0 dBm 
 Tx4: +1.9 dBm
 21:00
 Tx1: +6.3 dBm
 Tx2: +1.4 dBm/+4.4 dBm 
 Tx4: +1.5 dBm
 22:00
 Tx1: +6.5 dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.4 dBm
 23:00
 Tx1: +6.6dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.4 dBm


29 de Enero 2014
00:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 01:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 02:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.7 dBm 
 Tx4: +1.6 dBm
Voltage de linea 3959VAC, 295KW
 02:30
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 03:00
 Tx1: +6.1 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 04:00
 Tx1: +6.1 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 04:40 Falla PA2 (HP Baja)
 05:00
 Tx1: +6.1 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.2 dBm
 06:00
 Tx1: +6.2dBm
 Tx2: +1.6 dBm/+4.7 dBm 
 Tx4: +1.2 dBm
 Voltaje LInea 3900VAC 3F 295KW
 07:00
 Tx1: +6.3dBm
 Tx2: +1.7 dBm/+4.7 dBm 
 Tx4: +1.6 dBm
"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1353	29 Ene 04:40 Caida del la Fuente de alta	ISR		Transmitters		new	2014-01-29T08:02:29-05:00	2014-01-29T08:02:29-05:00	Se deshabilita el PA2 por alarma de flujo de HP.	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1352	29 Ene 06:20 Calibración de ATRs y TRs	ISR		Spark Gaps	jlavado	new	2014-01-29T07:54:29-05:00	2014-01-29T07:54:29-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1351	29 Ene 04:40 Falla en TXs	ISR		General	imanay	new	2014-01-29T06:50:57-05:00	2014-01-29T08:15:15-05:00	Cae TXs por falla en sistema de refrigeración.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1350	29 Ene 01:50 Calibración de ATRs y TRs	ISR		Spark Gaps	jlavado	new	2014-01-29T02:49:56-05:00	2014-01-29T02:49:56-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1349	29 Ene 00:01 Plots de experimento	ISR		Plot	imanay	new	2014-01-29T00:56:02-05:00	2014-01-29T00:56:02-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1348	28 Ene 21:40 Calibración de ATRs y TRs	ISR		Spark Gaps	jlavado	new	2014-01-28T22:32:00-05:00	2014-01-28T22:32:00-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1347	28 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-28T20:01:44-05:00	2014-01-28T20:01:44-05:00	"28 de Enero 2014
09:00
Tx1: +6.0 dBm
Tx2: +1.5 dBm/+4.6 dBm 
Tx4: +1.3 dBm 
Voltaje de linea:3930Vac, 300Kw
10:00
Tx1: +6.0 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.1 dBm
Voltaje de linea:3850Vac, 290Kw
11:00
Tx1: +6.0 dBm
Tx2: +1.3 dBm/+4.3 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3800Vac, 280Kw
12:00
Tx1: +6.4 dBm
Tx2: +1.7 dBm/+4.9 dBm 
Tx4: +1.5 dBm
Voltaje de linea:4000Vac, 300Kw
14:00
Tx1: +6.0 dBm
Tx2: +1.4 dBm/+4.5 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3850Vac, 300Kw
15:00
Tx1: +6.0 dBm
Tx2: +1.5 dBm/+4.5 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3850Vac, 300Kw
17:00
Tx1: +6.2 dBm
Tx2: +1.6 dBm/+4.7 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3900Vac, 300Kw
18:00
Tx1: +6.0 dBm
Tx2: +1.4 dBm/+4.7 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3860Vac, 300Kw
19:00
Tx1: +6.5 dBm
Tx2: +2.0 dBm/+5.2 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000Vac, 300Kw
"	ryaya
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1346	28 Ene 17:43 Ajuste de chisperos	ISR		Spark Gaps	ryanque	new	2014-01-28T19:43:32-05:00	2014-01-28T19:43:32-05:00	SE ajustaron los ATR	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1345	28 Ene 16:25 Reinicio de Faraday	ISR		Acquisition system	ryanque	new	2014-01-28T19:31:37-05:00	2014-01-28T19:31:37-05:00	"A las 15:45 se observa interferencias en EW Drift en todos los canales.
A las 16:05 se apaga el DDS de Faraday
A las 16:15 se reincia la adquisici[on de Faraday
A las 16:25 se reinicia el procesamiento de Faraday"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1344	28 Ene 15:14 Ajuste de chisperos	ISR		Spark Gaps	ryanque	new	2014-01-28T19:28:43-05:00	2014-01-28T19:28:43-05:00	Se ajusta el ATR 4	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1343	28 Ene 12:51 Ajuste de Chisperos	ISR		Spark Gaps	ryanque	new	2014-01-28T19:26:44-05:00	2014-01-28T19:26:44-05:00	"12:46 el nivel de ruido de canal C y D EW Drift sube
Luego del ajuste de chisperos vuelve a lo normal"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1342	28 Ene 12:26 Vuelve el ruido a nivel normal en Canal A y B EW Drift	ISR		Reception	ryanque	new	2014-01-28T19:24:05-05:00	2014-01-28T19:24:05-05:00	"A las 12:19 el nivel de ruido subio
A las 12:26 luego de ajustar los cables de Faraday vuelve a su nivel normal"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1341	28 Ene 10:05 Ajuste de Chisperos	ISR		Spark Gaps	ryanque	new	2014-01-28T19:21:20-05:00	2014-01-28T19:21:20-05:00	Ajuste de TR y ATR	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1340	28 Ene 07:54 Subiendo RTI	ISR		General	jverastegui	new	2014-01-28T08:39:41-05:00	2014-01-28T08:39:41-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1339	28 Ene 07:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-28T08:19:53-05:00	2014-01-28T08:19:53-05:00	"27 de Enero 2014
 20:00
 Tx1: +6.1 dBm
 Tx2: +1.2 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
 21:00
 Tx1: +6.1 dBm
 Tx2: +1.2 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
 22:00
 Tx1: +6.4 dBm
 Tx2: +1.8 dBm/+4.9 dBm 
 Tx4: +1.8 dBm
 23:00
 Tx1: +6.6dBm
 Tx2: +1.8 dBm/+4.9 dBm 
 Tx4: +1.8 dBm
28 de Enero 2014
 00:00
 Tx1: +6.3 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.4 dBm
 01:00
 Tx1: +6.2 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.4 dBm
 01:40 Falla PA1 Fuente Screen
 02:00
 Tx1: +6.2 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.4 dBm
 03:00
 Tx1: +6.2dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.8 dBm
 04:00
 Tx1: +6.1 dBm
 Tx2: +1.4 dBm/+4.2 dBm 
 Tx4: +1.3 dBm
 05:00
 Tx1: +6.1 dBm
 Tx2: +1.4 dBm/+4.2 dBm 
 Tx4: +1.3 dBm
 06:00
 Tx1: +6.2dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
 Voltaje LInea 3950VAC 3F 285KW
 07:00
 Tx1: +6.4dBm
 Tx2: +1.4 dBm/+4.5 dBm 
 Tx4: +1.6 dBm"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1338	28 Ene 05:56 Calibracion de los ATR's y TR's	ISR		Spark Gaps	jlavado	new	2014-01-28T08:09:20-05:00	2014-01-28T08:09:20-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1337	28 Ene 03:45 Atenuacion de 1dB en canal A para igualar al B (Faraday). Ruido entre A y B es menor a 1 dB.	ISR		Reception	jverastegui	new	2014-01-28T08:08:47-05:00	2014-01-28T08:08:47-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1336	28 Ene 03:37 Reemplazo de amplificador de campo del canal B de Faraday. Ruido entre A y B baja a poco mas de 1 dB	ISR		General	jlavado	new	2014-01-28T08:07:04-05:00	2014-01-28T08:07:04-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1335	28 Ene 03:15 Inicio de reparacion de linea de recepcion canal B de Faraday (dura 16 minutos)	ISR		Reception	jlavado	new	2014-01-28T08:04:23-05:00	2014-01-28T08:05:12-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1334	28 Ene 03:06 Cambio de TR canal B de Faraday, ruido entre A y B esta a mas de 3 dB	ISR		Transmitters	jlavado	new	2014-01-28T08:02:48-05:00	2014-01-28T08:02:48-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1333	28 Ene 02:30 Ruido entre A y B de Faraday sube a mas de 2 dB	ISR		General	jverastegui	new	2014-01-28T08:01:14-05:00	2014-01-28T08:01:14-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1332	28 Ene 01:18 Calibracion de los ATR's y TR's	ISR		Spark Gaps	jlavado	new	2014-01-28T08:00:09-05:00	2014-01-28T08:00:09-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1331	27 Ene 23:03 Mejoro ruido entre canales A y B de Faraday. Limpieza de chisperos	ISR		General	jverastegui	new	2014-01-28T07:59:21-05:00	2014-01-28T08:18:37-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1330	27 Ene 22:59 Diferencia de ruido entre canal A y B de Faraday mayor a 1 dB	ISR		General	jverastegui	new	2014-01-28T07:56:12-05:00	2014-01-28T07:56:12-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1329	27 Ene 20:49 Calibracion de los ATR's y TR's	ISR		Spark Gaps	jlavado	new	2014-01-28T07:55:16-05:00	2014-01-28T07:55:16-05:00	Mejora diferencia de ruido entre canal A y B de Faraday	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1328	27 Ene 20:40 Diferencia de ruido entre canal A y B de Faraday mayor a 4 dB	ISR		General	jverastegui	new	2014-01-28T07:52:51-05:00	2014-01-28T07:52:51-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1327	27 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-27T20:31:14-05:00	2014-01-27T20:31:14-05:00	"27 de Enero 2014
09:00
Tx1: +6.2 dBm
Tx2: +1.5 dBm/+4.6 dBm 
Tx4: +1.6 dBm 
Voltaje de linea:3900Vac, 300Kw
10:00
Tx1: +6.0 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.3 dBm
11:00
Tx1: +6.0 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3860Vac, 300Kw
12:00
Tx1: +6.4 dBm
Tx2: +1.6 dBm/+4.9 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3980Vac, 310Kw
14:00
Tx1: +6.0 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3850Vac, 300Kw
15:00
Tx1: +6.1 dBm
Tx2: +1.5 dBm/+4.7 dBm 
Tx4: +1.4 dBm
16:00
Tx1: +6.0 dBm
Tx2: +1.4 dBm/+4.7 dBm 
Tx4: +1.4 dBm
17:00
Tx1: +6.1 dBm
Tx2: +1.5 dBm/+4.8 dBm 
Tx4: +1.5 dBm
18:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3950Vac, 300Kw
19:00
Tx1: +6.2 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3980Vac, 300Kw"	ryaya
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1326	27 Ene 07:23 Lectura de Potencias.	ISR		Transmitters		new	2014-01-27T08:06:28-05:00	2014-01-29T07:41:14-05:00	"26 de Enero 2014
00:00
Tx1: +6.4 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.9 dBm
Voltaje de linea: 4040 Vac, 310 Kw
01:00
Tx1: +6.4 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.9 dBm
Voltaje de linea: 4040 Vac, 310 Kw
02:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 300 Kw
03:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 300 Kw
04:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 300 Kw
05:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 4000 Vac, 300 Kw
06:00
Tx1: +6.3 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
07:00
Tx1: +6.3 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1325	27 Ene 06:34 Calibracion de los ATR's y TR's	ISR	Others	Spark Gaps	AValdez	new	2014-01-27T07:39:33-05:00	2014-01-29T07:42:36-05:00		avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1324	27 Ene 02:30 Cambio de Amplificador Canal A	ISR	Others	Reception	AValdez	new	2014-01-27T07:35:53-05:00	2014-01-29T07:45:21-05:00	Se realizo el cambio del amplificador en el Canal A, debido a que la diferencia en el nivel del ruido volvio a aparecer, despues del cambio de amplificador el nivel del ruido entre los canales A y B se mantuvo menor a 1.	avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1323	27 Ene 02:15  Intercambio de Amplificadores	ISR	Others	Reception	AValdez	new	2014-01-27T07:32:08-05:00	2014-01-29T07:46:55-05:00	Se realizo el intercambio de amplificadores canal A y B(En el experimento Faraday), nivel de ruido canal A 31 db , canal B 33 db, despues del cambio disminuyo la diferencia, posible falla por conexion.	avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1322	27 Ene 03:37 CALIBRACION ATR's Y TR's	ISR	Others	Start experiment	AValdez	new	2014-01-27T05:55:52-05:00	2014-01-29T07:49:11-05:00		avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1321	26 Ene 24:00 Calibracion ATRs y TRs	ISR	Others	Start experiment	AValdez	new	2014-01-27T05:49:38-05:00	2014-01-29T07:50:37-05:00		avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1320	26 Ene 21:05 Calibracion ATRs y TRs	ISR	Others	Spark Gaps	AValdez	new	2014-01-27T05:41:30-05:00	2014-01-29T07:51:43-05:00		avaldez
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1319	26 Ene 23:18 Lectura de Potencias.	ISR		Transmitters		new	2014-01-27T00:02:26-05:00	2014-01-29T07:05:01-05:00	"26 de Enero 2014
20:00
Tx1: +6.1 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.5 dBm
Voltaje de linea: 4000 Vac, 310 Kw
21:00
Tx1: +6.1 dBm
Tx2: +1.4 dBm/+4.6 dBm 
Tx4: +1.5 dBm
Voltaje de linea: 4000 Vac, 310 Kw
22:00
Tx1: +6.4 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.9 dBm
Voltaje de linea: 4040 Vac, 310 Kw
23:00
Tx1: +6.4 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.9 dBm
Voltaje de linea: 4040 Vac, 310 Kw"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1318	26 Ene 18:00 Calibracion ATRs y TRs	ISR		Start experiment	Marcos Inonan	new	2014-01-26T20:22:47-05:00	2014-01-29T07:06:50-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1317	26 Ene 15:00 Calibracion ATRs y TRs	ISR		Transmitters	Marcos Inonan	new	2014-01-26T20:20:38-05:00	2014-01-29T07:07:34-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1316	26 Ene 12:17 Nivel de Ruido	ISR		Start experiment	Marcos Inonan	new	2014-01-26T20:17:51-05:00	2014-01-29T07:08:43-05:00	Se detectó un ruido de 34 dB en los canales A y B, el cual desapareció a las 12:29	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1315	26 Ene 12:00 Calibracion ATRs y TRs	ISR		Transmitters	Marcos Inonan	new	2014-01-26T20:16:03-05:00	2014-01-29T07:09:56-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1314	26 Ene 09:00 Calibracion ATRs y TRs	ISR		Transmitters		new	2014-01-26T20:15:16-05:00	2014-01-29T07:11:40-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1313	26 Ene 07:56 Interferencia	ISR		Reception		new	2014-01-26T20:12:47-05:00	2014-01-29T07:12:48-05:00	Se detectó una interferencia de origen desconocido en los canales A y B, ésta se fue a las 8:06 am.	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1312	26 Ene 07:56 Interferencia	ISR		Reception		new	2014-01-26T20:12:41-05:00	2014-01-29T07:27:14-05:00	Se detectó una interferencia de origen desconocido en los canales A y B, ésta se fue a las 8:06 am.	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1311	26 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-26T20:10:06-05:00	2014-01-26T20:10:06-05:00	"26 de Enero 2014

08:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.9 dBm 
 Tx4: +1.8 dBm
 09:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.8 dBm
 09:42 Falla PA2 Fuente Bias 
 10:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.8 dBm
 11:00
 Tx1: +6.2 dBm
 Tx2: +1.5 dBm/+4.7 dBm 
 Tx4: +1.4 dBm
 Voltaje de linea:4000 Vac, 300 Kw
 12:00
 Tx1: +6.3 dBm
 Tx2: +1.6 dBm/+4.7 dBm 
 Tx4: +1.4 dBm
 13:00
 Tx1: +6.4 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 14:00
 Tx1: +6.4 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 15:00
 Tx1: +6.4 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 16:00
 Tx1: +6.4 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 17:00
 Tx1: +6.4 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 Voltaje de linea:4000 Vac, 300 Kw
 18:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.8 dBm
 19:00
 Tx1: +6.2 dBm
 Tx2: +1.6 dBm/+4.8 dBm 
 Tx4: +1.8 dBm
 Voltaje de linea:4000 Vac, 300 Kw
"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1310	26 Ene 06:00 Calibracion de ATRs y TRs	ISR		Spark Gaps	A. Coronado	new	2014-01-26T08:38:25-05:00	2014-01-26T08:38:25-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1309	26 Ene 01:53 Calibracion de ATRs y TRs	ISR		Spark Gaps	DCordova	new	2014-01-26T08:37:34-05:00	2014-01-26T08:37:34-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1308	25 Ene 21:57 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	DCordova	new	2014-01-26T08:36:36-05:00	2014-01-26T08:36:36-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1307	26 Ene 07:49 Niveles de ruido	ISR		Process/Analysis Program	DCordova	new	2014-01-26T08:34:58-05:00	2014-01-26T08:34:58-05:00	" EW Drift
A: 25.90dB
B: 25.39dB
C: 25.31dB
D: 25.60dB
Faraday
C: 70.55dB
D: 71.45dB

El experimento esta corriendo con normalidad"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1306	25 Ene 19:53 Niveles de ruido	ISR		Acquisition system	DCordova	new	2014-01-26T08:31:49-05:00	2014-01-26T08:31:49-05:00	" EW Drift
A: 24.78dB
B: 24.38dB
C: 24.06dB
D: 24.11dB
Faraday
C: 68.13dB
D: 69.19dB

El experimento esta corriendo con normalidad"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1305	26 Ene 01:20 Subio la cohenercia entre Ay B debido al paso de hydra	ISR		Process/Analysis Program	DCordova	new	2014-01-26T08:27:26-05:00	2014-01-26T08:27:26-05:00	La coherencia subio hasta 0.4 y luego retorno a sus valores normales	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1304	26 Ene 00:55 Subio la cohenercia entre Cy D debido al paso de hydra	ISR		Process/Analysis Program	DCordova	new	2014-01-26T08:25:50-05:00	2014-01-26T08:25:50-05:00	La coherencia subio hasta 0.25 y luego retorno a sus valores normales	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1303	26 Ene 06:00 No se observo spreadF en la noche y madrugada	ISR		Process/Analysis Program	DCordova	new	2014-01-26T08:23:24-05:00	2014-01-26T08:23:24-05:00	No se observo spread F durante el turno	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1302	26 Ene 06:00 Aparece ventana de advertencia de Ubuntu por falla de su explorador	ISR		General	DCordova	new	2014-01-26T08:20:48-05:00	2014-01-26T08:20:48-05:00	"Se corto programa explorador de Ubuntu, esto genero la aparicion de la ventana de advertencia: System problem detected
Se presiono Cancel y se genero otra ventana: Sorru Ubuntu 12.04 has experienced an internal error
Se dejaron esas dos ventanas y el programa de procesamiento sigue funcionando normalmente"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1301	26 Ene 07:20 Lectura de Potencia	ISR		Transmitters		new	2014-01-26T08:05:03-05:00	2014-01-29T07:33:44-05:00	"26 de Enero 2014
00:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
00:05 Crowbar por caida de voltaje
01:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
02:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
03:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
04:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
05:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
06:00
Tx1: +6.3 dBm
Tx2: +1.5 dBm/+4.9 dBm 
Tx4: +1.7 dBm
Voltaje de linea: 4000 Vac, 300 Kw
07:00
Tx1: +6.5 dBm
Tx2: +1.9 dBm/+5.2 dBm 
Tx4: +2.0 dBm
Voltaje de linea: 4040 Vac, 310 Kw

"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1300	26 Ene 00:00 Figuras de rtis, epectros y resultados	ISR		Acquisition system	DCordova	new	2014-01-26T00:45:16-05:00	2014-01-26T00:45:16-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1299	25 Ene 23:45 Lectura de Potencia	ISR		Transmitters		new	2014-01-26T00:30:19-05:00	2014-01-29T07:39:14-05:00	"25 de Enero 2014
20:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 3950 Vac, 300 Kw
21:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 3950 Vac, 300 Kw
22:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 3950 Vac, 300 Kw
23:00
Tx1: +6.2 dBm
Tx2: +1.4 dBm/+4.8 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 3950 Vac, 300 Kw"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1298	25 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-25T20:07:05-05:00	2014-01-25T20:07:05-05:00	"25 de Enero 2014
 08:00
 Tx1: +6.3 dBm
 Tx2: +1.6 dBm/+4.6 dBm 
 Tx4: +1.6 dBm
 Voltaje de linea:3950 Vac, 295 Kw
 09:00
 Tx1: +6.5 dBm
 Tx2: +1.7 dBm/+4.7 dBm 
 Tx4: +1.6 dBm
 10:00
 Tx1: +6.6 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.5 dBm
 Voltaje de linea:3900 Vac, 300 Kw
 11:00
 Tx1: +6.6 dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.4 dBm
 Voltaje de linea:3900 Vac, 295 Kw
 12:00
 Tx1: +6.2 dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
 12:21 / 13:40 Revicion de linea y cambio de TR y Amplif.(CHB Faraday)
 13:00
 Tx1: +6.1 dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.4 dBm
 14:00
 Tx1: +5.9 dBm
 Tx2: +1.6 dBm/+4.7 dBm 
 Tx4: +1.5 dBm
 14:40/15:00 Arco electrico en la linea TX (Sup)
 15:00
 Tx1: +5.9 dBm
 Tx2: +1.6 dBm/+4.7 dBm 
 Tx4: +1.5 dBm
 16:00
 Tx1: +5.9 dBm
 Tx2: +1.6 dBm/+4.7 dBm 
 Tx4: +1.5 dBm
 17:00
 Tx1: +6.1 dBm
 Tx2: +1.8 dBm/+4.8 dBm 
 Tx4: +1.6 dBm
 18:00
 Tx1: +6.2 dBm
 Tx2: +1.7 dBm/+4.9 dBm 
 Tx4: +1.6 dBm
 Voltaje de linea:4000 Vac, 310 Kw
 19:00
 Tx1: +6.2 dBm
 Tx2: +1.4 dBm/+4.5 dBm 
 Tx4: +1.7 dBm
 Voltaje de linea:4000 Vac, 300 Kw"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1297	25 Ene 17:58 Calibración de ATR's y TR's	ISR		Spark Gaps	jlavado	new	2014-01-25T18:46:33-05:00	2014-01-27T17:04:46-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1296	25 Ene 15:00 Se repone experimento después de mantenimiento en ues	ISR		Antennas	imanay	new	2014-01-25T15:59:09-05:00	2014-01-27T17:05:53-05:00	Se realiza mantenimiento en ues: Sup, debido a arco encontrado.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1295	25 Ene 13:40 Se repone experimento	ISR		Break Experiment	imanay	new	2014-01-25T15:26:44-05:00	2014-01-27T17:07:09-05:00	"Corte de experimento de 13:20 a 13:40. Durante el corte se realizaron los siguientes cambios:
1. Cambio de TR y amplificador de campo del canal B de Faraday.
2. Cambio de tungnsteno roto de chispero de transmisión.
3. Cambio de cables de control de tx de controlador de radar de ew_drift y carga de 50 ohmios en 3era entrada de caja OR. (Interferencia en ew_drift se mantiene a pesar de estos cambios).

Las atenuaciones actuales son:
EW_drift(dB):
A: 0
B: 0
C: 1
D: 0
Faraday (dB):
A: 0
B: 0"	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1294	25 Ene 09:20 Calibración de ATR's y TR's	ISR		Spark Gaps	jlavado	new	2014-01-25T10:41:49-05:00	2014-01-27T17:28:05-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1293	25 Ene 08:00 Atenuación 1dB canal A de Faraday	ISR		Reception	imanay	new	2014-01-25T09:13:36-05:00	2014-01-27T17:29:40-05:00	El canal B de Faraday presenta fluctuaciones de 1 a 3 dB por debajo del canal A. Se está atenuando 1 dB el canal A para compensar la atenuación del canal B.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1292	25 Ene 06:00 Canales A, B y C sufren bajada	ISR		General	P. Condor	new	2014-01-25T08:47:45-05:00	2014-01-25T08:47:45-05:00	Canales A, B y C de EW_Drifts sufren bajada, despues se arreglan.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1291	25 Ene 05:25 Calibracion de ATRs y Trs	ISR		Antennas	A. Coronado	new	2014-01-25T08:45:11-05:00	2014-01-25T08:45:11-05:00	Calibracion de ATRs y Trs.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1290	25 Ene 07:00 Lectura de Potencias	ISR		Transmitters		new	2014-01-25T08:04:00-05:00	2014-01-25T08:04:00-05:00	"24 de Enero 2014
21:00
Tx1: +6.4 dBm
Tx2: +1.9 dBm/+5.0 dBm 
Tx4: +1.7 dBm 
Voltaje de linea:3960Vac, 300Kw
22:00
Tx1: +6.2 dBm
Tx2: +1.8 dBm/+5.0 dBm 
Tx4: +1.6 dBm
Voltaje de linea:3940Vac, 300Kw
23:00
Tx1: +6.3 dBm
Tx2: +1.8 dBm/+4.9 dBm 
Tx4: +1.6 dBm
Voltaje de linea:3900Vac, 300Kw

25 de Enero 2014
00:00
Tx1: +6.3 dBm
Tx2: +1.9 dBm/+5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3950Vac, 300Kw
01:00
Tx1: +6.2 dBm
Tx2: +1.8 dBm/+4.9 dBm 
Tx4: +1.7 dBm
02:00
Tx1: +6.2 dBm
Tx2: +1.9 dBm/+4.9 dBm 
Tx4: +1.8 dBm
03:00
Tx1: +6.2 dBm
Tx2: +1.9 dBm/+5.0 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3960Vac, 300Kw
04:00
Tx1: +6.2 dBm
Tx2: +1.9 dBm/+5.0 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3880Vac, 300Kw
05:00
Tx1: +6.2 dBm
Tx2: +1.8 dBm/+5.0 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3980Vac, 300Kw
06:00
Tx1: +6.2 dBm
Tx2: +1.8 dBm/+4.9 dBm 
Tx4: +1.7 dBm
07:00
Tx1: +6.2 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3960Vac, 300Kw"	ryaya
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1289	25 Ene 01:35 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2014-01-25T03:54:26-05:00	2014-01-25T03:54:26-05:00	Calibracion de ATRs y TRs.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1288	25 Ene 00:00 Figuras de rtis, epectros y resultados	ISR		Process/Analysis Program	P. Condor	new	2014-01-25T03:46:45-05:00	2014-01-25T03:46:45-05:00	Figuras de rtis, epectros y resultados	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1287	24 Ene 21:30 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2014-01-25T03:43:57-05:00	2014-01-25T03:43:57-05:00	Calibracion de ATRs y TRs.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1286	24 Ene 19:10 Lectura de Potencias	ISR		Transmitters		new	2014-01-24T19:57:30-05:00	2014-01-29T07:35:26-05:00	"24 de Enero 2014
08:00
Tx1: +6.0 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3890 Vac, 295 Kw
09:00
Tx1: +6.0 dBm
Tx2: +1.6 dBm/+4.8 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3890 Vac, 295 Kw
10:00
Tx1: +5.8 dBm
Tx2: +1.3 dBm/+4.5 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3800 Vac, 290 Kw
11:00
Tx1: +5.8 dBm
Tx2: +1.3 dBm/+4.5 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3800 Vac, 290 Kw
12:00
Tx1: +6.4 dBm
Tx2: +2.0 dBm/+4.7 dBm 
Tx4: +1.6 dBm
Voltaje de linea:4000 Vac, 310 Kw
13:00
Tx1: +6.4 dBm
Tx2: +2.0 dBm/+4.7 dBm 
Tx4: +1.6 dBm
Voltaje de linea:4000 Vac, 310 Kw
14:00
Tx1: +6.4 dBm
Tx2: +2.0 dBm/+4.7 dBm 
Tx4: +1.6 dBm
Voltaje de linea:4000 Vac, 310 Kw
14:27 Cae fuente deScreen Tx1 PA
15:00
Tx1: +6.0 dBm
Tx2: +1.5 dBm/+4.7 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3900 Vac, 300 Kw
15:52 HV OFF Para corregir arco en las Ues  ANTENAS
16:10 HV ON
16:15
Tx1: +6.2 dBm
Tx2: +1.7 dBm/+4.9 dBm 
Tx4: +1.6 dBm
Voltaje de linea: 3950 Vac, 310 Kw
17:00
Tx1: +6.2 dBm
Tx2: +1.7 dBm/+4.9 dBm 
Tx4: +1.6 dBm
Voltaje de linea:4000 Vac, 310 Kw
18:00
Tx1: +6.2 dBm
Tx2: +1.7 dBm/+4.9 dBm 
Tx4: +1.6 dBm
Voltaje de linea:4000 Vac, 310 Kw
19:00
Tx1: +6.3 dBm
Tx2: +1.8 dBm/+5.0 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 310 Kw"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1285	24 Ene 17:30 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	wrojas	new	2014-01-24T19:36:58-05:00	2014-01-24T19:36:58-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1284	24 Ene 15:50 Detectan problemas en las Us, inician mantenimiento	ISR		Antennas	wrojas	new	2014-01-24T19:35:40-05:00	2014-01-24T19:35:40-05:00	El mantenimiento dura 20 minutos (antena inactiva durante esos 20 minutos).	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1283	24 Ene 15:45 Se reinicia adquisicion de datos en PC_RADAR	ISR		Acquisition system	jverastegui	new	2014-01-24T19:32:11-05:00	2014-01-24T19:32:11-05:00	Los datos estaban corridos debido al reinicio anterior.	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1282	24 Ene 14:27 Se colgo PC_RADAR, se detiene adquisicion de Faraday	ISR		Acquisition system	jverastegui	reopened	2014-01-24T19:25:07-05:00	2014-01-24T19:47:40-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1281	24 Ene 14:00 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	wrojas	new	2014-01-24T19:17:59-05:00	2014-01-24T19:17:59-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1280	24 Ene 09:53 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	wrojas	new	2014-01-24T19:16:33-05:00	2014-01-24T19:16:33-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1279	24 Ene 07:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-24T08:03:02-05:00	2014-01-24T08:03:02-05:00	"23 Enero 2014
20:00
 Tx1: +6.2 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.7 dBm
21:00
 Tx1: +5.8 dBm
 Tx2: +1.8 dBm/+4.9 dBm 
 Tx4: +1.3 dBm
22:00
 Tx1: +5.8 dBm
 Tx2: +1.8 dBm/+4.9 dBm 
 Tx4: +1.3 dBm
23:00
 Tx1: +5.9 dBm
 Tx2: +2.0 dBm/+5.0 dBm 
 Tx4: +1.4 dBm
Voltaje de linea:3900 Vac, 300 Kw

24 Enero 2014
00:00
 Tx1: +5.3 dBm
 Tx2: +2.0 dBm/+5.0 dBm 
 Tx4: +1.6 dBm
01:00
 Tx1: +5.4 dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
02:00
 Tx1: +5.4 dBm
 Tx2: +1.4 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
03:00
 Tx1: +5.4 dBm
 Tx2: +1.5 dBm/+4.6 dBm 
 Tx4: +1.5 dBm
04:00
 Tx1: +5.4 dBm
 Tx2: +1.4 dBm/+4.5 dBm 
 Tx4: +1.6 dBm
05:00
 Tx1: +5.4 dBm
 Tx2: +1.4 dBm/+4.5 dBm 
 Tx4: +1.5 dBm
Voltaje de linea:3900 Vac, 290 Kw
06:00
 Tx1: +5.5 dBm
 Tx2: +1.8 dBm/+4.9 dBm 
 Tx4: +1.4 dBm
07:00
 Tx1: +5.5 dBm
 Tx2: +1.8 dBm/+5.0 dBm 
 Tx4: +1.5 dBm
"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1278	24 Ene 6:30 Calibración de ATRs y TRs	ISR		Spark Gaps	jlavado	new	2014-01-24T07:13:01-05:00	2014-01-27T18:32:42-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1277	24 Ene 02:30 Calibración de ATRs y TRs	ISR		Spark Gaps	jlavado	new	2014-01-24T05:36:55-05:00	2014-01-29T07:00:04-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1276	24 Ene 00:23 EW_drift Plots	ISR		Plot	imanay	new	2014-01-24T01:06:11-05:00	2014-01-29T07:01:12-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1275	24 Ene 00:18 Faraday Plots	ISR		Plot	imanay	new	2014-01-24T01:02:02-05:00	2014-01-29T07:01:47-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1274	23 Ene 21:55 Calibración de ATRs y TRs	ISR		Spark Gaps	jlavado	new	2014-01-23T22:41:23-05:00	2014-01-29T07:02:24-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1273	23 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-23T20:03:24-05:00	2014-01-23T20:03:24-05:00	"23 de Enero 2014
09:00
Tx1: +5.8 dBm
Tx2: +1.8 dBm/+4.8 dBm 
Tx4: +0.9 dBm 
Voltaje de linea:3850Vac, 300Kw
09:07 Falla fuente de pantalla PA 1
10:00
Tx1: +6.0 dBm
Tx2: +1.6 dBm/+4.7 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3850Vac, 300Kw
11:00
Tx1: +5.9 dBm
Tx2: +1.7 dBm/+4.7 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3810Vac, 300Kw
12:00
Tx1: +6.2 dBm
Tx2: +1.9 dBm/+5 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3920Vac, 300Kw
13:00
Tx1: +6.0 dBm
Tx2: +1.8 dBm/+4.8 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3900Vac, 300Kw
15:00
Tx1: +5.8 dBm
Tx2: +1.8 dBm/+4.8 dBm 
Tx4: +0.9 dBm
Voltaje de linea:3820Vac, 300Kw
16:00
Tx1: +5.8 dBm
Tx2: +1.8 dBm/+4.8 dBm 
Tx4: +0.9 dBm
Voltaje de linea:3810Vac, 300Kw
17:00
Tx1: +5.8 dBm
Tx2: +2.0 dBm/+5.0 dBm 
Tx4: +1.3 dBm
Voltaje de linea:3880Vac, 300Kw
18:00
Tx1: +6.2 dBm
Tx2: +2.2 dBm/+5.2 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3960Vac, 300Kw
19:00
Tx1: +6.2 dBm
Tx2: +2.2 dBm/+5.2 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3980Vac, 300Kw"	ryaya
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1272	23 Ene 18:00 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	A.Huamani	new	2014-01-23T18:56:47-05:00	2014-01-23T18:56:47-05:00	Se calibraron chispero	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1271	23 Ene 17:10 Niveles de ruido	ISR		Process/Analysis Program	DCordova	new	2014-01-23T18:33:31-05:00	2014-01-23T18:33:31-05:00	"EW Drift
A: 24.96dB
B: 24.54dB
C: 25.48dB
D: 25.23dB
Faraday
C: 69.67dB
D: 68.38dB

El experimento esta corriendo con normalidad"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1270	23 Ene 15:00 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	DCordova	new	2014-01-23T18:30:31-05:00	2014-01-23T18:31:11-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1269	23 Ene 14:45 Niveles de ruido	ISR		Process/Analysis Program	DCordova	new	2014-01-23T18:29:09-05:00	2014-01-23T18:29:09-05:00	"EW Drift
A: 24.74dB
B: 24.83dB
C: 25.42dB
D: 25.42dB
Faraday
C: 69.26dB
D: 69.05dB

El experimento esta corriendo con normalidad"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1267	23 Ene 12:00 Calibracion de chisperos ATR's Y TR's	ISR		Spark Gaps	A.Huamani	new	2014-01-23T18:24:02-05:00	2014-01-23T18:24:02-05:00		dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1266	23 Ene 10:03 Niveles de ruido	ISR		Process/Analysis Program	DCordova	new	2014-01-23T18:22:02-05:00	2014-01-23T18:22:02-05:00	"EW Drift
A: 30.72dB
B: 30.71dB
C: 31.57dB
D: 31.52dB
Faraday
C: 75dB
D: 77dB

El experimento esta corriendo con normalidad

"	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1265	23 Ene 09:10 Se observa que la coherencia es diferente de cero a partir de 400Km en los canales C y D	ISR		Process/Analysis Program	DCordova	new	2014-01-23T18:18:28-05:00	2014-01-23T18:18:28-05:00	Se observa que la coherencia disminuye en 400Km y sube a 0.05 a mayores alturas, esto se debe a que el ruido, a partir de 400Km, esta un poco correlacionado, sin embargo este valor es aceptable.	dcordova
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1264	23 Ene 07:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-23T08:03:25-05:00	2014-01-23T08:03:25-05:00	"22 de Enero 2014
 20:00
 Tx1: +6.2 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.5 dBm
 21:00
 Tx1: +6.2 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.5 dBm
 Voltaje de linea:3950 Vac, 295 Kw
 22:00
 Tx1: +6.2 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.5 dBm
 23:00
 Tx1: +6.3 dBm
 Tx2: +2.3 dBm/+5.2 dBm 
 Tx4: +1.5 dBm
23 Enero 2014
 00:10
 Falla en la linea de transmision
 00:45
 Falla de la fuente Screen PA1
 01:00
 Tx1: +6.4 dBm
 Tx2: +2.3 dBm/+5.4 dBm 
 Tx4: +1.6 dBm
 02:00
 Tx1: +6.4 dBm
 Tx2: +2.3 dBm/+5.2 dBm 
 Tx4: +1.5 dBm
 03:00
 Tx1: +6.4 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.5 dBm
 04:00
 Tx1: +6.1 dBm
 Tx2: +2.1 dBm/+5.2 dBm 
 Tx4: +1.4 dBm
 05:00
 Tx1: +6.0 dBm
 Tx2: +2.1 dBm/+5.2 dBm 
 Tx4: +1.4 dBm
 06:00
 Tx1: +6.0 dBm
 Tx2: +2.1 dBm/+5.2 dBm 
 Tx4: +1.4 dBm
 Voltaje de linea:3950 Vac, 300 Kw
 07:00
 Tx1: +6.0 dBm
 Tx2: +2.1 dBm/+5.2 dBm 
 Tx4: +1.4 dBm
 "	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1263	23 Ene 06:00 Calibracion de Atr y TR	ISR		Antennas	J. Lavado	new	2014-01-23T07:14:39-05:00	2014-01-23T07:14:39-05:00	Calibracion de Atr y Tr.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1262	23 Ene 03:09 Se baja 1 dB ch B	ISR		Process/Analysis Program	P Condor	new	2014-01-23T07:12:57-05:00	2014-01-23T07:12:57-05:00	Se baja 1 dB ch B. Cambiando la atenuacion de 2 a 1. Ahora A y B esta parejos. Tambien se cambia el db_range en el programa bajando 2 dB.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1261	23 Ene 01:56 Intercambio de TR de ch A y B.	ISR		Process/Analysis Program	P Condor	new	2014-01-23T07:10:25-05:00	2014-01-23T07:10:25-05:00	Intercambio de TR de ch A y B, para ver si falla el TR puesto en B. Ok, esta bien el TR. Se deja el ruido del Ch B a 22 dB, debajo de Ch A.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1260	23 Ene 01:45 Ch B cae el ruido a 15 dB	ISR		Process/Analysis Program	P Condor	new	2014-01-23T07:05:48-05:00	2014-01-23T07:05:48-05:00	Ch B, cae el ruido a 15 dB.Se cambia el TR.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1259	23 Ene 01:40 Calibracion de chisperos Atr y Tr	ISR		Antennas	J. Lavado	new	2014-01-23T07:03:25-05:00	2014-01-23T07:03:25-05:00	Calibracion de chisperos Atr y Tr.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1258	23 Ene 00:39 Se prende el transmisor	ISR		Antennas	P Condor	new	2014-01-23T07:01:39-05:00	2014-01-23T07:01:39-05:00	Se prende el transmisor despues de la reparacion. Por el momento no hay chispas.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1257	23 Ene 00:00 Figuras de rtis, espectros  y resultados	ISR		Process/Analysis Program	P Condor	new	2014-01-23T06:55:15-05:00	2014-01-23T06:55:15-05:00	Figuras de rtis, espectros  y resultados del 22-01-2013.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1256	23 Ene 00:15 Se apaga Transmisor	ISR		Antennas	P Condor	new	2014-01-23T06:53:41-05:00	2014-01-23T06:53:41-05:00	Se apaga Transmisor, para revisar un tubo donde chispea cerca a la Us.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1255	22 Ene 22:07 Calibracion de Atrs y Trs	ISR		Antennas	J. Lavado	new	2014-01-23T04:54:15-05:00	2014-01-23T04:54:15-05:00	Calibracion de Atrs y Trs.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1254	22 Ene 21:54 Se volvio ejecutar Faraday	ISR		Acquisition system	P Condor	new	2014-01-23T04:52:12-05:00	2014-01-23T04:52:12-05:00	Se volvio ejecutar Faraday. Despues de varias corridas se sincronizo.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1253	22 Ene 20:00 Lectura de potencias	ISR		Transmitters		new	2014-01-22T20:49:39-05:00	2014-01-22T20:49:39-05:00	"22 de Enero 2014
09:00
Tx1: +6.0 dBm
Tx2: +2.0 dBm/+5.0 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3890 Vac, 300 Kw
10:00
Tx1: +6.1 dBm
Tx2: +1.8 dBm/+4.8 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3820 Vac, 300 Kw
11:00
Tx1: +5.9 dBm
Tx2: +1.8 dBm/+4.8 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3800 Vac, 300 Kw
13:30
Tx1: +6.0 dBm
Tx2: +1.7 dBm/+4.7 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3820 Vac, 300 Kw
14:00
Tx1: +5.4 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +0.8 dBm
Voltaje de linea:3780 Vac, 290 Kw
15:00
Tx1: +5.5 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +0.9 dBm
Voltaje de linea:3780 Vac, 290 Kw
16:00
Tx1: +5.5 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3800 Vac, 290 Kw
17:00
Tx1: +5.5 dBm
Tx2: +1.2 dBm/+4.2 dBm 
Tx4: +1.0 dBm
Voltaje de linea:3800 Vac, 290 Kw
18:00
Tx1: +6.1 dBm
Tx2: +2.2 dBm/+5.2 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3900 Vac, 300 Kw
19:00
Tx1: +6.2 dBm
Tx2: +2.2 dBm/+5.2 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 300 Kw"	ryaya
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1252	22 Ene 17:40 Se atenuo en 1 dB mas el canal B	ISR		Reception		new	2014-01-22T20:05:38-05:00	2014-01-22T20:05:38-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1251	22 Ene 17:30 Calibracion de los ATRs y TRs	ISR		Antennas		new	2014-01-22T20:04:04-05:00	2014-01-22T20:04:41-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1250	22 Ene 14:40 Revision de estado de cables de controlador	ISR		Acquisition system		new	2014-01-22T20:02:28-05:00	2014-01-22T20:02:28-05:00	"Debido a que las franjas que se observaron durante todo el dia aparecieron cuando el transmisor estaba apagado. Posiblemente causadas por la transmision (alguna irregularidad con la electronica?) de pulsos a la fase de recepcion. Se adjunta imagen de la presencia de franjas mientras el transmisor se encontraba apagado.
"	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1249	22 Ene 16:00 Se atenuo en 1db el canal B	ISR		Reception		new	2014-01-22T19:56:30-05:00	2014-01-22T19:56:30-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1248	22 Ene 14:41 Se prende transmisor	ISR		Transmitters		new	2014-01-22T19:54:58-05:00	2014-01-22T19:54:58-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1247	22 Ene 14:40 Se apaga transmisor y se cambia TR del canal A	ISR		Acquisition system		new	2014-01-22T19:54:13-05:00	2014-01-22T19:54:13-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1246	22 Ene 14:35 Se prende transmisor	ISR		Transmitters		new	2014-01-22T19:53:17-05:00	2014-01-22T19:53:17-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1245	22 Ene 14:30 Se cambiaron cables de TR del canal B	ISR		Acquisition system		new	2014-01-22T19:52:28-05:00	2014-01-22T19:52:28-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1244	22 Ene 14:23 Se apago transmisor	ISR		Transmitters		new	2014-01-22T19:51:31-05:00	2014-01-22T19:51:31-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1243	22 Ene 14:19 Se cambio TR del canal B	ISR		Acquisition system		new	2014-01-22T19:50:36-05:00	2014-01-22T19:50:36-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1242	21 Ene 14:17 Se apago transmisor	ISR		Transmitters		new	2014-01-22T19:49:23-05:00	2014-01-22T19:49:23-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1241	22 Ene 14:00 Calibracion de ATRs y TRs	ISR		Antennas		new	2014-01-22T19:47:57-05:00	2014-01-22T19:48:28-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1240	22 Ene 9:40 Calibracion de ATRs y TRs	ISR		Antennas		new	2014-01-22T19:44:47-05:00	2014-01-22T19:47:04-05:00		minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1239	22 Ene 04:26 am Incremento de ruido de fondo en los canales de Faraday	ISR		General		new	2014-01-22T08:37:05-05:00	2014-01-22T08:37:05-05:00	Se realizaron ajustes de chisperos pero no disminuyo el ruido. Origen desconocido.	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1238	22 Ene 2014 06:36 Calibración de ATRs y TRs	ISR		Spark Gaps		reopened	2014-01-22T08:34:44-05:00	2014-01-22T10:37:50-05:00	Se calibro a las 6:36 am	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1237	22 Ene 2014 02:32 Calibración de ATRs y TRs	ISR		Spark Gaps		reopened	2014-01-22T08:33:54-05:00	2014-01-22T10:37:39-05:00	Se calibro a las 2:32 am del 22 de Enero	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1236	21 Ene 2014 22:36 Calibración de ATRs y TRs	ISR		Spark Gaps		reopened	2014-01-22T08:33:00-05:00	2014-01-22T10:37:18-05:00	Se calibro a las 10:36 pm	minonan
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1234	21 Enero 2014-23:15 Lectura de Potencias	ISR		Transmitters		new	2014-01-21T23:57:28-05:00	2014-01-21T23:57:28-05:00	"21 de Enero 2014
20:00
Tx1: +6.5 dBm
Tx2: +2.4 dBm/+5.3 dBm 
Tx4: +1.9 dBm
Voltaje de linea:4050 Vac, 320 Kw
21:00
Tx1: +6.5 dBm
Tx2: +2.4 dBm/+5.3 dBm 
Tx4: +1.9 dBm
Voltaje de linea:4050 Vac, 320 Kw
22:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.3 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 310 Kw
23:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.3 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 310 Kw"	vquesada
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1233	21 Ene 18:30 Calibracion de ATRs y TRs	ISR		Antennas	J. Lavado	new	2014-01-21T20:43:10-05:00	2014-01-21T20:43:10-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1232	21 Ene 14:00 Calibracion de ATRs y TRs	ISR		Antennas	J. Lavado	new	2014-01-21T20:42:39-05:00	2014-01-21T20:42:39-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1231	21 Ene 13:59 Se colgo ARES	ISR		Acquisition system	D. Suarez	new	2014-01-21T20:41:57-05:00	2014-01-21T20:41:57-05:00	Se colgo ARES	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1230	21 Ene 10:00 Se reinicia procesamiento de EW_Drifts	ISR		Process/Analysis Program	D. Suarez	new	2014-01-21T20:41:15-05:00	2014-01-21T20:41:15-05:00	Se reinicia procesamiento de EW_Drifts	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1229	21 Ene 09:15 Se cuelga el programa de procesamiento EW_Drifts	ISR		Process/Analysis Program	D. Suarez	new	2014-01-21T20:40:24-05:00	2014-01-21T20:40:24-05:00	Se cuelga el programa de procesamiento EW_Drifts	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1228	21 Ene 09:30 Calibracion de chisperos ATRs y TRs	ISR		Antennas	J. Lavado	new	2014-01-21T20:38:52-05:00	2014-01-21T20:38:52-05:00	Calibracion de chisperos ATRs y TRs	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1227	21 Ene 09:10 Caida de Tx	ISR		Transmitters	D. Suarez	new	2014-01-21T20:37:33-05:00	2014-01-21T20:37:33-05:00	Caida de Tx	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1226	21 Ene 08:00 Se reinicia la adquisicion	ISR		Acquisition system	D. Suarez	new	2014-01-21T20:35:50-05:00	2014-01-21T20:35:50-05:00	 Se reinicia la adquisicion de datos, estan correcto desde esta hora.	pcondor
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1225	21 Ene 19:00 Lectura de Potencia	ISR		Transmitters		new	2014-01-21T19:51:39-05:00	2014-01-21T19:51:39-05:00	"21 de Enero 2014
08:00
 Tx1: +6.4 dBm
 Tx2: +2.2 dBm/+5 dBm 
 Tx4: +1.7 dBm
 Voltaje de linea:3950Vac, 295Kw
09:00
 Tx1: +6.0 dBm
 Tx2: +2.0 dBm/+5 dBm 
 Tx4: +1.4 dBm
09:13 Falla Screen PA2
10:00
 Tx1: +6.0 dBm
 Tx2: +1.9 dBm/+5 dBm 
 Tx4: +1.2 dBm
11:00
 Tx1: +6.0 dBm
 Tx2: +1.8 dBm/+5 dBm 
 Tx4: +1.2 dBm
 Voltaje de linea:3840Vac, 295Kw
12:00
 Tx1: +6.0 dBm
 Tx2: +2.0 dBm/+5 dBm 
 Tx4: +1.2 dBm
13:00
 Tx1: +6.1 dBm
 Tx2: +2.0 dBm/+5 dBm 
 Tx4: +1.2 dBm
14:00
 Tx1: +6.2 dBm
 Tx2: +1.7 dBm/+4.8 dBm 
 Tx4: +1.2 dBm
 Voltaje de linea:3850Vac, 295Kw
15:00
 Tx1: +6.2 dBm
 Tx2: +1.9 dBm/+5 dBm 
 Tx4: +1.4 dBm
16:00
 Tx1: +6.1 dBm
 Tx2: +1.9 dBm/+5 dBm 
 Tx4: +1.4 dBm
17:00
 Tx1: +6.4 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.6 dBm
 Voltaje de linea:3920Vac, 300Kw
18:00
 Tx1: +6.3 dBm
 Tx2: +2.2 dBm/+5.2 dBm 
 Tx4: +1.7 dBm
19:00
 Tx1: +6.1 dBm
 Tx2: +2.2 dBm/+5.3 dBm 
 Tx4: +1.8 dBm






 
"	rtadeo
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1224	21 Ene 08:00 Falla en adquisición de Faraday	ISR		Acquisition system	avaldez	new	2014-01-21T15:52:40-05:00	2014-01-30T19:25:17-05:00	Datos desincronizados desde las 05:14 hasta las 08:00.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1223	21 Ene 04:52 Calibración de ATRs y TRs	ISR		Spark Gaps	avaldez	new	2014-01-21T15:49:57-05:00	2014-01-30T19:25:03-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1222	21 Ene 01:12 Calibración de ATRs y TRs	ISR		Spark Gaps	avaldez	new	2014-01-21T15:49:06-05:00	2014-01-30T19:24:50-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1221	21 Ene 01:04 Reinicio de adquisición de Faraday	ISR		Acquisition system	avaldez	new	2014-01-21T15:45:35-05:00	2014-01-30T19:24:35-05:00	Datos del sistema Faraday desincronizados desde el re-inicio de experimento (21:30). Se reinicia el programa de adquisición en PC	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1220	20 Ene 23:20 Falla de TR en canal A	ISR		Reception	avaldez	new	2014-01-21T15:41:38-05:00	2014-01-30T19:24:21-05:00	Falla TR de canal A, se realiza el cambio y se continua con normalidad.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1219	20 Ene 22:40 Falla de TR en canal A	ISR		Reception	avaldez	new	2014-01-21T15:39:29-05:00	2014-01-30T19:24:10-05:00	Falla TR del canal A, se realiza el cambio y se continua con normalidad.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1218	20 Ene 21:20 Calibración de ATRs y TRs	ISR		Spark Gaps	avaldez	new	2014-01-21T15:37:08-05:00	2014-01-30T19:23:54-05:00		imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1217	20 Ene 21:20 Reinicio de experimento	ISR		Start experiment	imanay	new	2014-01-21T09:18:24-05:00	2014-01-30T19:23:34-05:00	Energía eléctrica fue cortada a las 19:00 y re-establecida a las 20:30 aproximadamente.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1216	20 Ene 18:40 Reinicio interfase de monitoreo	ISR		Plot	imanay	new	2014-01-20T19:37:19-05:00	2014-01-30T19:22:41-05:00	Se cuelga interfase de monitoreo de EW_Drift: IDL 7.1, por lo que fue reiniciada.	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1215	20 Ene 16:46 Inicio de experimento (Ver manual)	ISR		Start experiment	imanay	new	2014-01-20T18:28:18-05:00	2014-01-30T19:22:03-05:00	"Se realizan varios ajustes al sistema:

-Correción de arco en líneas de 6"" en switchyard (15:30).
-Corrección de arco en fuente de Tx (16:05).
-Corrección de conexión en líneas de recepción de EW_drift (16:32).
-Reinicio de adquisición del sistema Faraday (16:46).
"	imanay
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1214	20 Jan 14:40 Antena VSWR	ISR	Others	Antennas	ryanque	new	2014-01-20T15:39:28-05:00	2014-01-20T15:39:28-05:00	"VSWR
WUP 1.01
WDN 1.04
NDN 1.07   49.99 1.00
NUP 1.08   49.41 1.03
EUP 1.04
EDN 1.04
SDN 1.09   49.98 1.03
SUP 1.05"	ryanque
Milestone 2014_01_EWDrift + Faraday SSW Jan 22 - 31	1213	20 Jan 08:43 Log EWDrifit + Faraday SSW Jan 20 -31	ISR	Others	Start experiment	ryanque	new	2014-01-20T09:39:31-05:00	2014-01-20T09:39:31-05:00	Se creo el log	ryanque
Milestone 2014_01 MST-ISR + EEJ	1377	30 Ene 18:30 Manual de experimento	ISR		General	imanay	new	2014-01-30T19:14:49-05:00	2014-01-30T19:17:10-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1212	10 Ene 2014 18:10 Resumen TX	ISR		Transmitters		new	2014-01-10T19:18:17-05:00	2014-01-10T19:18:17-05:00	"08:00 
Tx1: +3.8 dBm
Tx4: +3.4 dBm
09:00
Tx1: +3.8 dBm
Tx4: +3.4 dBm
10:00
Tx1: +3.5 dBm
Tx4: +3.4 dBm
Voltaje de linea:3850 Vac, 280 Kw
10:30 Falla fuente de pantalla PA1
11:00
Tx1: +3.6 dBm
Tx4: +3.4 dBm
Voltaje de linea:3850 Vac, 280 Kw
12:00
Tx1: +3.8 dBm
Tx4: +3.6 dBm
Voltaje de linea:4000 Vac, 290 Kw
13:00
Tx1: +3.7 dBm
Tx4: +3.5 dBm
Voltaje de linea:3900 Vac, 290 Kw
14:00
Tx1: +3.4 dBm
Tx4: +3.2 dBm
Voltaje de linea:3820 Vac, 280 Kw
14:10 RF OFF ajuste de potencia PA 1
15:00
Tx1: +3.6 dBm
Tx4: +3.5 dBm
16:00
Tx1: +3.8 dBm
Tx4: +3.6 dBm
Voltaje de linea:3900 Vac, 290 Kw
17:00
Tx1: +3.8 dBm
Tx4: +3.6 dBm
18:00 HV OFF
18:15 LV OFF"	ryaya
Milestone 2014_01 MST-ISR + EEJ	1211	10 Ene 18:00 2014 Fin de experimento	ISR		End experiment	imanay	new	2014-01-10T19:09:34-05:00	2014-01-10T19:09:34-05:00	Se apagan transmisores y se detiene la adquisicion del sistema JARS.	imanay
Milestone 2014_01 MST-ISR + EEJ	1210	10 Ene 15:14 2014 Calibracion de ATRs y TRs	ISR		Spark Gaps	wrojas	new	2014-01-10T19:08:06-05:00	2014-01-10T19:08:06-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1209	10 Ene 14:00 2014 Interferencias	ISR		Plot	imanay	new	2014-01-10T19:06:05-05:00	2014-01-10T19:06:05-05:00	Se notan interferencias en todo el espectro y a diferentes alturas desde las 12:30 cada 10 a 15 minutos.	imanay
Milestone 2014_01 MST-ISR + EEJ	1208	10 Ene 2014 12:00 Calibración de ATR's y TR's	ISR		Spark Gaps	imanay	new	2014-01-10T12:56:05-05:00	2014-01-10T12:56:05-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1207	10 Ene 2014 10:25 Se reinició la adquisición	ISR		Acquisition system	imanay	new	2014-01-10T12:55:29-05:00	2014-01-10T12:55:29-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1206	10 Ene 2014 08:50 Calibración de ATR's y TR's	ISR		Spark Gaps	imanay	new	2014-01-10T09:57:15-05:00	2014-01-10T09:57:15-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1205	10 Ene 07:40 Se ejecuta de nuevo Batch en Jars	ISR		Acquisition system	P. Condor	new	2014-01-10T08:36:54-05:00	2014-01-10T08:36:54-05:00	 Se ejecuta de nuevo Batch en Jars	pcondor
Milestone 2014_01 MST-ISR + EEJ	1204	10 Enero 07:23 Variacion de la potencia y lineas de  AC	ISR		Transmitters		new	2014-01-10T08:13:25-05:00	2014-01-10T08:13:25-05:00	"09 de Enero 2014
 21:00
 Tx1: +4.0 dBm
 Tx4: +3.5 dBm
 Voltaje de linea:4000 Vac, 300 Kw
 22:00
 Tx1: +4.3 dBm
 Tx4: +3.9 dBm
 Voltaje de linea:4000 Vac, 300 Kw
 23:00
 Tx1: +3.9 dBm
 Tx4: +3.6 dBm
 Voltaje de linea:3950 Vac, 300 Kw


10 Enero 2014
 00:00
 Tx1: +3.9 dBm
 Tx4: +3.6 dBm
 Voltaje de linea:3950 Vac, 300 Kw
 01:00
 Tx1: +4.2 dBm
 Tx4: +3.6 dBm
 Voltaje de linea:4000 Vac, 300 Kw
 02:00
 Tx1: +3.8 dBm
 Tx4: +3.5 dBm
 Voltaje de linea: 3940 Vac, 300 Kw
 03:00
 Tx1: +4.0 dBm
 Tx4: +3.6 dBm
 Voltaje de linea: 3950 Vac, 300 Kw
 04:00
 Tx1: +4.0 dBm
 Tx4: +3.6 dBm
 Voltaje de linea: 3950 Vac, 300 Kw
 05:00
 Tx1: +3.8 dBm
 Tx4: +3.6 dBm
 Voltaje de linea: 3960 Vac, 300 Kw
 06:00
 Tx1: +3.8 dBm
 Tx4: +3.6 dBm
 Voltaje de linea: 3960 Vac, 300 Kw
 07:00
 Tx1: +4.2 dBm
 Tx4: +3.4 dBm
 Voltaje de linea: 4000 Vac, 300 Kw
"	rtadeo
Milestone 2014_01 MST-ISR + EEJ	1203	10 Ene 06:11 Se ejecuta batch en Jars	ISR		Acquisition system	P. Condor	new	2014-01-10T07:05:56-05:00	2014-01-10T07:05:56-05:00	Se ejecuta batch en Jars. Porque no registraba datos y se tuvo que ejecutar varias veces hasta que corrio de nuevo.	pcondor
Milestone 2014_01 MST-ISR + EEJ	1202	10 Ene 05:40 Calibracion de ATRs y TRs	ISR		Antennas	J Lavado	new	2014-01-10T06:56:47-05:00	2014-01-10T06:56:47-05:00	Calibracion de ATRs y TRs.	pcondor
Milestone 2014_01 MST-ISR + EEJ	1201	10 Ene 05:35 Se vuelve a ejecutarlo batch en Jars	ISR		Acquisition system	P. Condor	new	2014-01-10T06:55:17-05:00	2014-01-10T06:55:17-05:00	Se vuelve a ejecutarlo batch en Jars. Porque salia error y no registraba datos.	pcondor
Milestone 2014_01 MST-ISR + EEJ	1200	10 Ene 02:35 Se para batch en Jars	ISR		Acquisition system	P. Condor	new	2014-01-10T06:53:40-05:00	2014-01-10T06:53:40-05:00	Se para batch en Jars. Salia error y no registraba datos. Se vuelve a ejecutarlo.	pcondor
Milestone 2014_01 MST-ISR + EEJ	1199	10 Ene 01:30 Calibracion Atrs y Trs	ISR		Antennas	J Lavado	new	2014-01-10T06:50:38-05:00	2014-01-10T06:50:38-05:00	Calibracion Atrs y Trs.	pcondor
Milestone 2014_01 MST-ISR + EEJ	1198	09 Ene 22:40 Calibracion Atrs y Trs	ISR		Antennas	J Lavado	new	2014-01-10T06:49:32-05:00	2014-01-10T06:49:32-05:00	Calibracion Atrs y Trs	pcondor
Milestone 2014_01 MST-ISR + EEJ	1197	09 Ene 2014 20:05 Resumen TX	ISR		Transmitters		new	2014-01-09T21:03:06-05:00	2014-01-09T21:03:06-05:00	"08:00 
Tx1: +4.0 dBm
Tx4: +3.9 dBm
09:00
Tx1: +3.9 dBm
Tx4: +3.8 dBm
Voltaje de linea:3950 Vac, 300 Kw
10:00
Tx1: +3.8 dBm
Tx4: +3.6 dBm
Voltaje de linea:3890 Vac, 290 Kw
11:00
Tx1: +3.6 dBm
Tx4: +3.4 dBm
Voltaje de linea:3850 Vac, 280 Kw
11:05 Falla fuente de pantalla PA 1
13:30
Tx1: +3.8 dBm
Tx4: +3.6 dBm
Voltaje de linea:3880 Vac, 290 Kw
14:00
Tx1: +3.8 dBm
Tx4: +3.6 dBm
15:10 RF OFF
15:30 RF ON
15:38 RF OFF
15:50 RF ON
16:35
Tx1: +3.8 dBm
Tx4: +3.7 dBm
17:00
Tx1: +3.6 dBm
Tx4: +3.5 dBm
Voltaje de linea:3900 Vac, 280 Kw
18:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea:4000 Vac, 300 Kw

"	ryaya
Milestone 2014_01 MST-ISR + EEJ	1181	09 Ene 2014 07:35 Problemas con programa de adquisicion	ISR		Acquisition system	DCordova	new	2014-01-09T08:39:11-05:00	2014-01-09T08:39:11-05:00	"Se cuelga programa de adquisicion, se reinicia el program por 3 veces pero no inicia.
7:45 Se apaga y prende JARS y controlador de radar, luego si puede iniciar el programa de adquisicion"	dcordova
Milestone 2014_01 MST-ISR + EEJ	1180	09 Ene 2014 07:28 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T08:18:29-05:00	2014-01-09T08:18:29-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1179	09 de Enero 2014-07:00 Lectura de Potencias	ISR		Transmitters		new	2014-01-09T07:54:24-05:00	2014-01-09T07:54:24-05:00	"09 Enero 2014
00:00
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea:3950 Vac, 300 Kw
01:00
Tx1: +4.2 dBm
Tx4: +4.1 dBm
Voltaje de linea:4050 Vac, 300 Kw
02:00
Tx1: +4.2 dBm
Tx4: +4.1 dBm
Voltaje de linea: 4050 Vac, 300 Kw
03:00
Tx1: +4.2 dBm
Tx4: +4.1 dBm
Voltaje de linea: 4050 Vac, 300 Kw
04:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea: 4000 Vac, 300 Kw
05:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea: 4000 Vac, 300 Kw
06:00
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea: 4000 Vac, 300 Kw
07:00
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea: 4000 Vac, 300 Kw"	vquesada
Milestone 2014_01 MST-ISR + EEJ	1178	09 Ene 2014 01:14 Problemas con programa de adquisicion	ISR		Acquisition system	DCordova	new	2014-01-09T07:25:54-05:00	2014-01-09T07:25:54-05:00	"Se observa falta de sincronismo en los datos, se detiene y reinicia programa de adquisicion.
Luego, los datos se generan de forma correcta"	dcordova
Milestone 2014_01 MST-ISR + EEJ	1177	09 Ene 2014 06:04 Calibracion de chisperos	ISR		Spark Gaps	ACoronado	new	2014-01-09T06:55:31-05:00	2014-01-09T06:55:31-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1176	09 Ene 2014 06:02 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T06:52:14-05:00	2014-01-09T06:52:14-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1175	09 Ene 2014 05:35 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T06:28:44-05:00	2014-01-09T06:28:44-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1174	09 Ene 2014 03:04 Calibracion de chisperos	ISR		Spark Gaps	ACoronado	new	2014-01-09T05:17:11-05:00	2014-01-09T05:17:11-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1173	09 Ene 2014 04:20 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T05:12:46-05:00	2014-01-09T05:12:46-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1172	09 Ene 2014 01:02 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T02:01:12-05:00	2014-01-09T02:01:12-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1171	09 Ene 2014 00:01 Calibracion de chisperos	ISR		Spark Gaps	ACoronado	new	2014-01-09T02:00:11-05:00	2014-01-09T02:00:11-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1170	08 Ene 2014 23:30 Revision de TR de canal 3	ISR		Reception	DCordova	new	2014-01-09T01:58:34-05:00	2014-01-09T01:58:34-05:00	Se observa senial mas debil en el canal 3 por ello se retiro y cambio por otro para su revision, se encontro que estas en buen estado y se retorno a las 23:40pm	dcordova
Milestone 2014_01 MST-ISR + EEJ	1169	09 Ene 2014 00:00 Problemas con programa de procesamiento	ISR		Process/Analysis Program	DCordova	new	2014-01-09T01:55:19-05:00	2014-01-09T01:55:19-05:00	Con el cambio de dia no funciona el programa de procesamiento, se edito programas para que direccione la carpeta del dia 9 de enero	dcordova
Milestone 2014_01 MST-ISR + EEJ	1168	08 Ene 2014 23:55 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T00:45:39-05:00	2014-01-09T00:45:39-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1167	23:30-08 de Enero 2014 Lectuta de Potencias	ISR		Transmitters		new	2014-01-09T00:24:38-05:00	2014-01-09T00:24:38-05:00	"08 de Enero 2014
20:00
Tx1: +4.2 dBm
Tx4: +3.9 dBm
Voltaje de linea:3950 Vac, 290 Kw
21:00
Tx1: +4.2 dBm
Tx4: +3.9 dBm
Voltaje de linea:3950 Vac, 290 Kw
22:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:3950 Vac, 300 Kw
23:00
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea:3950 Vac, 300 Kw"	vquesada
Milestone 2014_01 MST-ISR + EEJ	1166	08 Ene 2014 22:15 Se detiene programa de adquisiscion	ISR		Acquisition system	DCordova	new	2014-01-09T00:13:58-05:00	2014-01-09T00:13:58-05:00	Sale error en programa de adquisicion y se vuelve a iniciar este	dcordova
Milestone 2014_01 MST-ISR + EEJ	1165	08 Ene 2014 23:18 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-09T00:10:21-05:00	2014-01-09T00:10:21-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1164	08 Ene 2014 22:57 Imagenes de espectros	ISR		Plot	DCordova	new	2014-01-08T23:47:47-05:00	2014-01-08T23:47:47-05:00	Se esta colgando la imagenes de los espectros que se estan observando	dcordova
Milestone 2014_01 MST-ISR + EEJ	1163	08 Ene 2014 21:31 Se detiene programa de adquisiscion	ISR		Acquisition system	DCordova	new	2014-01-08T22:30:38-05:00	2014-01-08T22:30:38-05:00	Programa de adquisicion falla y se detiene, se vuelve a reiniciar el program de adquisicion	dcordova
Milestone 2014_01 MST-ISR + EEJ	1162	08 Ene 2014 21:00 Calibracion de chisperos	ISR		Spark Gaps	ACoronado	new	2014-01-08T22:09:18-05:00	2014-01-08T22:09:18-05:00		dcordova
Milestone 2014_01 MST-ISR + EEJ	1161	08 Ene 2014 20:00 Falla en la pagina de Jicamarca	ISR		Start experiment	DCordova	new	2014-01-08T22:07:38-05:00	2014-01-08T22:07:38-05:00	"Daniel Suarez tambien indico que hay problemas con la pagina web de Jicamarca, no puede cargar, sale el siguiente mensaje:
The connection has timed out
The server at jro.igp.gob.pe is taking too long to respond.
"	dcordova
Milestone 2014_01 MST-ISR + EEJ	1160	08 Ene 2014 20:00 Cambio de personal de turno	ISR		Process/Analysis Program	DCordova	new	2014-01-08T21:51:34-05:00	2014-01-08T21:51:34-05:00	"Se realizo el cambio de personal de turno.
Transmisor. Rfael Tadeo indico que esta funcionando normal
Chisperos. Jose Lavado indico que el ajuste de chispoeros es cada 3 horas, la siguiente calibracion es a las 9pm
Jefe de turno. Daniel Suarez indico que se detuvo dos veces en la maniana
Se tienen dos programas para procesamiento de datos:
    operaciones@operaciones:~/workspace_roj/schainpy/test$ python isrproc.py
    operaciones@operaciones:~/workspace_roj/schainpy/test$ python mstisr.py

El primero genera espectros de ISR, el segundo genera espectros de EEJ y MST
Cuando se inician los programas siguen a la adquisiscion y luego se retrazan, por ello se esta corriendo cada 10 minutos
Ademas, se observa que los ruidos son los siguientes:
20:46 EEJ
N1: 20.45dB, N2: 20.31dB, N3: 20.04, N4: 18.61dB
20.47 ISR
N1: 45.71dB, N2: 45.37dB, N3: 45.18, N4: 44.28dB
20:46 MST
N1: 38.45dB, N2: 38.77dB, N3: 38.84, N4: 36.92dB

Se observa que el canal4 presenta menos ruido que el resto (1.4dB, 1.5dB, 1.9 dB)
"	dcordova
Milestone 2014_01 MST-ISR + EEJ	1159	08 Enero 08:00 Variacion de la potencia y lineas de  AC	ISR	Others	Transmitters		new	2014-01-08T19:54:29-05:00	2014-01-08T19:54:29-05:00	"  18:00
 Tx1: + 4.1dBm
 Tx4: + 4.0dBm
  19:00
 Tx1: +4.0 dBm
 Tx4: +3.8 dBm
 Voltaje de linea: 3950Vac, 290Kw"	rtadeo
Milestone 2014_01 MST-ISR + EEJ	1158	08 Enero 08:00 Variacion de la potencia y lineas de  AC	ISR	Others	Transmitters		new	2014-01-08T18:31:05-05:00	2014-01-08T18:31:05-05:00	"08 de Enero 2014
 08:00
 Tx1: +4.0 dBm
 Tx4: +3.9 dBm
 Voltaje de linea:3960 Vac, 290 Kw
 09:00
 Tx1: +3.8 dBm
 Tx4: +3.6 dBm
 Voltaje de linea:3890 Vac, 260 Kw
 09:39 Falla Fuente Screen PA1
 10:00
 Tx1: +3.8 dBm
 Tx4: +3.4 dBm
 Voltaje de linea:3860 Vac, 260 Kw
 11:00
 Tx1: +3.6 dBm
 Tx4: +3.4 dBm
 Voltaje de linea:3850 Vac, 290 Kw
12:51 Falla Screen PA1.
 13:00
 Tx1: +3.8 dBm
 Tx4: +3.7 dBm
 14:00
 Tx1: +3.7 dBm
 Tx4: +3.8 dBm
 15:00
 Tx1: +3.8 dBm
 Tx4: +3.7 dBm
 Voltaje de linea: 3900 Vac, 290 Kw
 16:00
 Tx1: +3.9 dBm
 Tx4: +3.8 dBm
 Voltaje de linea: 3950 Vac, 285 Kw
 17:15
 Tx1: +3.4 dBm
 Tx4: +3.2 dBm
 Voltaje de linea: 3790 Vac, 250 Kw
 18:00
 Tx1: + dBm
 Tx4: + dBm
 Voltaje de linea:  Vac,  Kw
 19:00
 Tx1: + dBm
 Tx4: + dBm
 Voltaje de linea:  Vac,  Kw
 "	rtadeo
Milestone 2014_01 MST-ISR + EEJ	1157	08 Enero 2014 07:20 Lectura de Potencias	ISR		Transmitters		new	2014-01-08T08:10:29-05:00	2014-01-08T08:10:29-05:00	"07 de Enero 2014
20:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:4000 Vac, 290 Kw
21:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:4000 Vac, 290 Kw
22:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:4000 Vac, 290 Kw
23:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:4000 Vac, 290 Kw

08 Enero 2014
00:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:4000 Vac, 290 Kw
00:08 Ca fuente de screen PA Tx1
01:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea:4000 Vac, 290 Kw
02:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea: 3950 Vac, 285 Kw
03:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea: 3950 Vac, 285 Kw
04:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea: 3950 Vac, 285 Kw
05:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea: 3950 Vac, 285 Kw
06:00
Tx1: +4.0 dBm
Tx4: +3.9 dBm
Voltaje de linea: 3950 Vac, 285 Kw
07:00
Tx1: +4.2 dBm
Tx4: +4.0 dBm
Voltaje de linea: 4000 Vac, 290 Kw
"	vquesada
Milestone 2014_01 MST-ISR + EEJ	1156	08 Ene 2014 00:27 Reincios en el sistema de adquisición	ISR		Acquisition system	avaldez	new	2014-01-08T08:08:13-05:00	2014-01-08T08:08:13-05:00	El sistema de adquisicion falla a las 00:27,02:34 ,05:57 y a las 07:07 am, se muestra mensaje de error y se recomienda resetear, se vuelve a ejecutar el batch y se continua con la adquisicion	avaldez
Milestone 2014_01 MST-ISR + EEJ	1155	07 Ene 2014 22:13 Reincios en el sistema de adquisición	ISR		Acquisition system	avaldez	new	2014-01-08T08:05:38-05:00	2014-01-08T08:05:38-05:00	El sistema de adquisicion falla a las 22:13 y a las 22:57 pm, se muestra mensaje de error y se recomienda resetear, se vuelve a ejecutar el batch y se continua con la adquisicion	avaldez
Milestone 2014_01 MST-ISR + EEJ	1154	07 Ene 2014 19:55 Resumen TX	ISR		Transmitters		new	2014-01-07T20:56:03-05:00	2014-01-09T20:53:50-05:00	"07:00 LV ON
07:15 HV ON
07:40
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea:4000 Vac, 280 Kw
08:05 RF OFF (sistema de adquisición)
09:28 Falla fuente SCREEN PA 1
09:33 Falla fuente SCREEN PA 1
10:20 
Tx1: +3.9 dBm
Tx4: +3.6 dBm
11:50
Tx1: +4.0 dBm
Tx4: +3.7 dBm
Voltaje de linea:3900 Vac, 290 Kw
13:10 RF OFF, HV OFF (ruido en canales de Rx)
13:40 HV ON
13:50 Falla fuente SCREEN PA1
13:57 FAlla fuente SCREEN PA1
14:15
Tx1: +4.0 dBm
Tx4: +3.8 dBm
Voltaje de linea:3880 Vac, 290 Kw
14:40 Falla fuente SCREEN PA1
15:00
Tx1: +3.9 dBm
Tx4: +3.8 dBm
Voltaje de linea:3850 Vac, 290 Kw
16:00
Tx1: +3.9 dBm
Tx4: +3.8 dBm
Voltaje de linea:3850 Vac, 290 Kw
17:00
Tx1: +4.0 dBm
Tx4: +3.9 dBm
Voltaje de linea:3900 Vac, 300 Kw
18:00 Falla fuente SCREEN PA1
18:01
Tx1: +4.1 dBm
Tx4: +3.9 dBm
Voltaje de linea:3900 Vac, 290 Kw
18:20 Falla ventilador izquierdo, solo se usa ventilador derecho
19:00
Tx1: +4.0 dBm
Tx4: +3.8 dBm
19:20 Falla fuente SCREEN PA1"	ryaya
Milestone 2014_01 MST-ISR + EEJ	1153	07 Ene 2014 19:21 Sin Tx	ISR		Reception	imanay	new	2014-01-07T20:17:17-05:00	2014-01-07T20:17:17-05:00	Solo se observa ruido en canales de recepción debido a caida de TXs.	imanay
Milestone 2014_01 MST-ISR + EEJ	1152	07 Ene 2014 19:20 Calibración de ATR's y TR's	ISR		Spark Gaps	wrojas	new	2014-01-07T20:14:11-05:00	2014-01-07T20:14:11-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1151	07 Ene 2014 16:13 Calibración de ATR's y TR's	ISR		Spark Gaps	wrojas	new	2014-01-07T20:06:25-05:00	2014-01-07T20:06:25-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1150	07 Ene 2014 13:41 Calibración de ATR's y TR's	ISR		Spark Gaps	wrojas	new	2014-01-07T20:05:41-05:00	2014-01-07T20:05:41-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1149	07 Ene 2014 13:43 Reincios en el sistema de adquisición	ISR		Acquisition system	imanay	new	2014-01-07T20:03:14-05:00	2014-01-07T20:03:14-05:00	La adquisición fue reiniciada a las 13:10, 13:20 y 13:42 debido a incrementos no esperados en el ruido de los canales. Solar flare se había producido horas antes.	imanay
Milestone 2014_01 MST-ISR + EEJ	1148	07 Ene 2014 10:27 Calibración de ATR's y TR's	ISR		Spark Gaps	wrojas	new	2014-01-07T19:55:06-05:00	2014-01-07T19:55:06-05:00		imanay
Milestone 2014_01 MST-ISR + EEJ	1147	07 Ene 2014 07:40 Se inicia experimento	ISR		Start experiment	imanay	new	2014-01-07T19:52:32-05:00	2014-01-07T19:52:32-05:00	Se está usando sistema JARS, 4 canales y 4 etapas de amplificación.	imanay
Milestone 2014_01 MST-ISR + EEJ	1145	06 Ene 11:56 Antena VSWR	ISR		Antennas		new	2014-01-06T12:46:24-05:00	2014-01-06T12:46:24-05:00	"VSWR
Wup 1.07
Wdn 1.07
Ndn 1.06
Nup 1.02
Eup 1.06
Edn 1.03
Sdn 1.07
Sup 1.04"	ryanque
Milestone 2014_01 MST-ISR + EEJ	1144	06 Ene 11:53 Log for MST-ISR + EEJ	ISR		Start experiment		new	2014-01-06T12:44:20-05:00	2014-01-07T10:26:25-05:00	"Se ha creado el Log para el experimento MST-ISR + EEJ
Periodo: Martes 07 al Viernes 10 de Enero 2014.
"	ryanque
Milestone 2013_11 EWDrift + Faraday ISCOD	1143	11 Dic 16:00 Se subieron datos a Madrigal	ISR		Process/Analysis Program		new	2013-12-11T17:25:45-05:00	2013-12-11T17:25:45-05:00	Se subieron datos a Madrigal del 04 al 07 de noviembre.	pcondor
Milestone 2013_11 EWDrift + Faraday ISCOD	1141	07 Nov 13:32 FIN DE EXPERIMENTO ISR (EW_DRIFT+FARADAY)	ISR		End experiment	R. Abad	new	2013-11-07T12:40:47-05:00	2013-11-07T12:40:47-05:00	Se detiene experimento.	rabad
Milestone 2013_11 EWDrift + Faraday ISCOD	1140	07  Nov 10:50 Se reinicia adquisici'on en PC ARES	ISR		Acquisition system	R. Abad	new	2013-11-07T12:36:15-05:00	2013-11-07T12:36:15-05:00	-Pierde sincronismo el sistema de adquisici'on de EW_Drift, se reinica adquisici'on en PC ARES.	rabad
Milestone 2013_11 EWDrift + Faraday ISCOD	1139	07 Nov 10:25 Ajuste de chisperos ATR's y TR's	ISR		Spark Gaps	A. Coronado	new	2013-11-07T12:34:06-05:00	2013-11-07T12:34:06-05:00		rabad
Milestone 2013_11 EWDrift + Faraday ISCOD	1138	07 Nov 13:10 Lectura de Potencias	ISR		Transmitters		new	2013-11-07T12:09:28-05:00	2013-11-07T12:09:28-05:00	"07 de Noviembre 2013
08:00
Tx1: +6.4 dBm
Tx2: +1.8, +5.1 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3955 Vac, 290 Kw
09:00
Tx1: +6.4 dBm
Tx2: +1.8, +5.1 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3955 Vac, 290 Kw
10:00
Tx1: +6.2 dBm
Tx2: +1.5, +5.0 dBm 
Tx4: +0.9 dBm
Voltaje de linea:3900 Vac, 290 Kw
11:00
Tx1: +6.2 dBm
Tx2: +1.5, +5.0 dBm 
Tx4: +0.9 dBm
Voltaje de linea:3900 Vac, 290 Kw
12:00
Tx1: +6.4 dBm
Tx2: +2.0, +5.2 dBm 
Tx4: +1.5 dBm
Voltaje de linea:4000 Vac, 300 Kw
13:00
Tx1: +6.4 dBm
Tx2: +2.0, +5.2 dBm 
Tx4: +1.5 dBm
Voltaje de linea:4000 Vac, 300 Kw
"	vquesada
Milestone 2013_11 EWDrift + Faraday ISCOD	1137	07 Nov 07:00 lectura de las potencias	ISR		Transmitters		new	2013-11-07T06:25:11-05:00	2013-11-07T06:25:11-05:00	"06/11/2013
20:00

 Tx1: +6 dBm
 Tx2: +3, +6.0 dBm 
 Tx4: +1.8 dBm


21:00

Tx1: +6.6 dBm
 Tx2: +3, +6.0 dBm 
 Tx4: +1.8 dBm


22:00



Tx1: +6.6 dBm
 Tx2: +2.6, +5.4 dBm 
 Tx4: +1.5 dBm


23:00



 Tx1: +6.6 dBm
 Tx2: +2.6, +5.4 dBm 
 Tx4: +1.5 dBm


07/11/2013


00:00



 Tx1: +6.4 dBm
 Tx2: +2.5, +5.6 dBm 
 Tx4: +1.2 dBm


01:00



 Tx1: +6.4 dBm
 Tx2: +2.5, +5.6 dBm 
 Tx4: +1.2 dBm
01:05        -Falla alta crowbar -

02:00

 Tx1: +6.4 dBm
 Tx2: +2.5, +5.6 dBm 
 Tx4: +1.2 dBm


03:00



Tx1: +6.4 dBm
 Tx2: +2.5, +5.6 dBm 
 Tx4: +1.2 dBm


04:00



Tx1: +6.3 dBm
 Tx2: +1.6, +5.1 dBm 
 Tx4: +1.2 dBm


05:00



Tx1: +6.4 dBm
 Tx2: +1.6, +5.2 dBm 
 Tx4: +1.2 dBm


06:00



Tx1: +6.4 dBm
 Tx2: +1.6, +5.2 dBm 
 Tx4: +1.2 dBm


07:00



Tx1: +6.6 dBm
 Tx2: +2.0, +5.4 dBm 
 Tx4: +1.4 dBm
"	rtadeo
Milestone 2013_11 EWDrift + Faraday ISCOD	1136	07 Nov 07:15 Ajuste de ATRs	ISR		Antennas		new	2013-11-07T06:25:01-05:00	2013-11-07T06:25:01-05:00	Ajuste de ATRs	pcondor
Milestone 2013_11 EWDrift + Faraday ISCOD	1135	07 Nov 01:06 Ajuste de ATRs	ISR		Antennas		new	2013-11-07T06:24:21-05:00	2013-11-07T06:24:21-05:00	 Ajuste de ATRs	pcondor
Milestone 2013_11 EWDrift + Faraday ISCOD	1134	07 Nov 01:05 Caida de Transmisor	ISR		Transmitters		new	2013-11-07T06:23:25-05:00	2013-11-07T06:23:25-05:00	Caida de Transmisor	pcondor
Milestone 2013_11 EWDrift + Faraday ISCOD	1133	07 Nov 00:00 Figuras rtis, espectros, ruidos y resultados	ISR		Process/Analysis Program		new	2013-11-06T23:24:24-05:00	2013-11-06T23:24:24-05:00	Figuras rtis, espectros, ruidos y resultados	pcondor
Milestone 2013_11 EWDrift + Faraday ISCOD	1132	06 Nov 20:37 Calibracion de ATrs	ISR		Antennas		new	2013-11-06T23:12:08-05:00	2013-11-06T23:12:08-05:00	Calibracion de ATrs	pcondor
Milestone 2013_11 EWDrift + Faraday ISCOD	1131	06  Noviembre 2013 19:44 Caida de Transmisores	ISR		Start experiment		new	2013-11-06T18:53:48-05:00	2013-11-06T18:53:48-05:00	Se detecta caida de transmisores, se dio aviso al personal de transmiosres y se corrigio la falla. Se continua con el expermiento con normalidad.	avaldez
Milestone 2013_11 EWDrift + Faraday ISCOD	1130	06 de Noviembre 2013 19:40: Lectura de Potencias	ISR		Transmitters		new	2013-11-06T18:37:42-05:00	2013-11-06T18:37:42-05:00	"06 de Noviembre 2013
13:00:00
Tx1: +6.2 dBm
Tx2: +1.6, +5.1 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3950 Vac, 310 Kw
13:35  a 16;40 se para los TXs por falla en TX1, no llega señal al driver1, despues de varias pruebas se encuentra que un cable Rg8 esta malo.
16:45 se reicio todo
Tx1: +6.2 dBm
Tx2: +1.3, +5.1 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3900 Vac, 295 Kw
17:00
Tx1: +6.2 dBm
Tx2: +1.3, +5.1 dBm 
Tx4: +1.2 dBm
Voltaje de linea:3950 Vac, 2950 Kw
18:00
Tx1: +6.5 dBm
Tx2: +2.4, +5.5 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3950 Vac, 300 Kw
19:00
Tx1: +6.5 dBm
Tx2: +2.4, +5.5 dBm 
Tx4: +1.4 dBm
Voltaje de linea:3950 Vac, 300 Kw"	vquesada
Milestone 2013_11 EWDrift + Faraday ISCOD	1129	06  Noviembre 2013 16:50  REINICION NORMAL DEL EXPERIMETO	ISR		Start experiment		new	2013-11-06T16:12:11-05:00	2013-11-06T16:12:11-05:00	Se reinicia la adquisicion de los experimento EW_DRIFT_FARADAY Y DP_PULSE tras haber superado las dificultades presentadas en los transmisores.	avaldez
Milestone 2013_11 EWDrift + Faraday ISCOD	1128	06  Noviembre 2013 15:15 SE DETIENE ADQUISICION	ISR		Start experiment	AValdez	new	2013-11-06T16:10:05-05:00	2013-11-06T16:10:05-05:00	Se presentan falla en el area de transmisores, los trabajos continuan y se detiene la adquiscion hasta que se reincorporen los transmisores.	avaldez
Milestone 2013_11 EWDrift + Faraday ISCOD	1127	06 de Noviembre 2013 14:20 Cambio de  un Transmisor	ISR		Start experiment	AValdez	new	2013-11-06T16:07:24-05:00	2013-11-06T16:07:24-05:00	Se presenta una falla en uno  de los transmisores, y se procedio a realizar el cambio.El equipo de transmisores realiza las operaciones correspondientes.	avaldez
Milestone 2013_11 EWDrift + Faraday ISCOD	1126	06 de Noviembre 2013 16:50 Falla Tx3	ISR		Transmitters		new	2013-11-06T15:55:23-05:00	2013-11-06T15:55:23-05:00	"De 13:35 a 16:40 los Txs no transmiten
FALLA:no no hay  señal en la entrada de Driver 1
Solucion: se cambia de atrad 4 al atrad 2 pero aun persiste la falla, se intenta varias soluciones al final se ENCUENTRA QUE EL CABLE RG8 MALO, que conecta al atrad con el driver 1, se cambia por otro cable y se soluciona el problema"	vquesada
Milestone 2013_11 EWDrift + Faraday ISCOD	1125	06 de Noviembre 2013 12:15 Lectura de Potencias	ISR		Transmitters		new	2013-11-06T11:15:56-05:00	2013-11-06T11:15:56-05:00	"06 de Noviembre 2013
08:00
Tx1: +6.6 dBm
Tx2: +1.9, +5.1 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4050 Vac, 310 Kw
09:00
Tx1: +6.6 dBm
Tx2: +1.9, +5.1 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4050 Vac, 310 Kw
10:00
Tx1: +6.8 dBm
Tx2: +1.5, +5.3 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3950 Vac, 300 Kw
11:00
Tx1: +6.8 dBm
Tx2: +1.5, +5.3 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3950 Vac, 300 Kw
12:00
Tx1: +6.2 dBm
Tx2: +1.6, +5.1 dBm 
Tx4: +1.8 dBm
Voltaje de linea:3950 Vac, 310 Kw
"	vquesada
Milestone 2013_11 EWDrift + Faraday ISCOD	1124	06 Nov 07:00 lectura de las potencias	ISR		Transmitters		new	2013-11-06T06:12:07-05:00	2013-11-06T06:12:07-05:00	"05/11/2013

21:00
 Tx1: +6 dBm
 Tx2: +1.9, +5.0 dBm 
 Tx4: +1.8 dBm


22:00
 Tx1: +6.0 dBm
 Tx2: +1.9, +5 dBm 
 Tx4: +1.8 dBm


23:00
 Tx1: +6.2 dBm
 Tx2: +1.8, +5 dBm 
 Tx4: +1.6 dBm
06/11/2013

00:00
 Tx1: +6.3 dBm
 Tx2: +1.7, +5.0 dBm 
 Tx4: +1.6 dBm


01:00
 Tx1: +6.2 dBm
 Tx2: +1.7, +5.0 dBm 
 Tx4: +1.6 dBm


02:00
 Tx1: +6.5 dBm
 Tx2: +1.9, +5 dBm 
 Tx4: +1.8 dBm


03:00
 Tx1: +6.0 dBm
 Tx2: +1.8, +5 dBm 
 Tx4: +1.8 dBm


04:00
 Tx1: +6.0 dBm
 Tx2: +1.8, +5 dBm 
 Tx4: +1.6 dBm


05:00
 Tx1: +6.0 dBm
 Tx2: +1.8, +5 dBm 
 Tx4: +1.6 dBm


06:00
 Tx1: +6.0 dBm
 Tx2: +1.8, +5 dBm 
 Tx4: +1.6 dBm


07:00
 Tx1: +6.6 dBm
 Tx2: +1.9, +5.2 dBm 
 Tx4: +1.8 dBm
"	rtadeo
Milestone 2013_11 EWDrift + Faraday ISCOD	1123	06 Nov 04:35 Cambio amplificador de campo de Faraday	ISR		Reception	I. Manay	new	2013-11-06T04:16:48-05:00	2013-11-06T04:16:48-05:00	Se cambia amplificador de campo de linea de recepción A de Faraday. Esta línea esta aproximadamente 1.5 dB por debajo de forma intermitente.	imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1122	05 de Noviembre 23:59 Plots	ISR		Plot	I. Manay	new	2013-11-05T23:15:35-05:00	2013-11-05T23:15:35-05:00		avaldez
Milestone 2013_11 EWDrift + Faraday ISCOD	1121	05 Nov 20:00 Lectura de potencias TX	ISR		Transmitters		new	2013-11-05T19:09:12-05:00	2013-11-05T19:09:12-05:00	"09:00
Tx1: +6 dBm
Tx2: +1.6, +5.1 dBm 
Tx4: +1.8 dBm

10:00
Tx1: +5.7 dBm
Tx2: +1.7, +5 dBm 
Tx4: +1.5 dBm

11:00
Tx1: +5.6 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm

12:00
Tx1: +6 dBm
Tx2: +1.9, +5.2 dBm 
Tx4: +1.6 dBm

13:00
Tx1: +6 dBm
Tx2: +1.9, +5.1 dBm 
Tx4: +1.9 dBm

14:00
Tx1: +5.7 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm

15:00
Tx1: +5.6 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm

16:00
Tx1: +5.7 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm

17:00
Tx1: +5.9 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm

18:00
Tx1: +5.9 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.8 dBm

19:00
Tx1: +6 dBm
Tx2: +1.9, +5.2 dBm 
Tx4: +1.9 dBm
"	ryaya
Milestone 2013_11 EWDrift + Faraday ISCOD	1120	05 de Noviembre 2013 07:15 Lectura de Potencias	ISR		Transmitters		new	2013-11-05T06:17:23-05:00	2013-11-05T06:17:23-05:00	"05:00
Tx1: +5.4 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm
Voltaje de linea:3950 Vac, 300 Kw
06:00
Tx1: +5.9 dBm
Tx2: +1.9, +5.1 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 300 Kw
07:00
Tx1: +5.9 dBm
Tx2: +1.9, +5.1 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 300 Kw"	vquesada
Milestone 2013_11 EWDrift + Faraday ISCOD	1118	04 de Noviembre 23:55 Graficos obtenidos	ISR		Start experiment	A.Valdez	new	2013-11-05T00:00:06-05:00	2013-11-05T00:09:40-05:00		avaldez
Milestone 2013_11 EWDrift + Faraday ISCOD	1117	04 de Noviembre 23:00 Lectura de Potencias	ISR		Transmitters		new	2013-11-04T22:05:31-05:00	2013-11-04T22:05:31-05:00	"04 de Noviembre del 2013
13:27
Tx1: +5.5 dBm
Tx2: +1.6, +5 dBm 
Tx4: +1.3 dBm
14:28
Tx1: +5.5 dBm
Tx2: +1.6, +5 dBm 
Tx4: +1.3 dBm
16:00
Tx1: +5.5 dBm
Tx2: +1.6, +5 dBm 
Tx4: +1.3 dBm
17:14
Tx1: +6 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm
18:00
Tx1: +5.8 dBm
Tx2: +1.5, +4.7 dBm 
Tx4: +1.6 dBm
20:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
21:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
22:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
23:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
"	vquesada
Milestone 2013_11 EWDrift + Faraday ISCOD	1116	04 Nov 13:30 Se reinicia toma de datos de EW_Drift & Faraday	ISR		General	I. Manay	new	2013-11-04T13:11:27-05:00	2013-11-04T13:11:27-05:00	Con los siguientes transmisores: TX1, TX2 y TX4	imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1115	04 Nov 10:50 Se corta experimento para habiilitar TX4 de Faraday	ISR		Transmitters	I. Manay	new	2013-11-04T10:20:47-05:00	2013-11-04T10:20:47-05:00		imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1114	04 Nov 10:20 Corto en spark-gap de carga	ISR		Spark Gaps	I. Manay	new	2013-11-04T10:17:53-05:00	2013-11-04T10:17:53-05:00	Se abre spark-gap de carga conectado a hibrido (H2). Se mejora la coherencia.	imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1113	04 Nov 10:04 Se cambia TR-s para verificar coherencia de canales C y D	ISR		Reception	I. Manay	new	2013-11-04T10:13:41-05:00	2013-11-04T10:13:41-05:00		imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1112	04 Nov 09:00 Sale EW_Drift con 2 Tx's	ISR		General	I. Manay	new	2013-11-04T10:09:57-05:00	2013-11-04T10:09:57-05:00	El problema de coherencia en los canales C y D se mantiene.	imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1111	04 Nov 08:40 Problema de coherencia	ISR		Reception	I. Manay	new	2013-11-04T10:06:44-05:00	2013-11-04T10:06:44-05:00	Se observa problema de coherencia en canales C y D. Se corta experimento para poner el 2do TX (RF combinado de EW_Drift y Faraday)	imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1110	04 Nov 08:20 Se inicia EW_drift con 1 TX	ISR		General	I. Manay	new	2013-11-04T09:47:47-05:00	2013-11-04T09:47:47-05:00		imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1109	04 Nov 06:40 Falla TX3	ISR		Transmitters	I. Manay	new	2013-11-04T09:43:37-05:00	2013-11-04T09:43:37-05:00	Se procede a cambio de transmisor	imanay
Milestone 2013_11 EWDrift + Faraday ISCOD	1108	02 Nov 17:50 Test Results	ISR		Plot		new	2013-11-03T22:21:45-05:00	2013-11-03T22:21:45-05:00	Los resultados de la prueba se adjuntan.	ryanque
Milestone 2013_11 EWDrift + Faraday ISCOD	1107	03 Nov 11:00 Log for EWDrift + Faraday Nov 2013 Activated	ISR		Start experiment		new	2013-11-03T22:19:27-05:00	2013-11-03T22:25:46-05:00	"El log ha sido activado.
El log se encuentra en
jro-log.igp.gob.pe
ISR
Hito: 2013_11 EWDrift + Faraday ISCOD, es el último"	ryanque
Milestone 2013_10_1 JASMET - MST	1182	06 Ene 10:00 Medición de Longitud de cables de JASMET 30 MHz	ISR		Antennas		new	2014-01-09T13:56:03-05:00	2014-01-09T13:56:03-05:00	"       Soldar   Cable Bajada  L. Comun  Impedancia
Rx A   Derecha   3.3 m          24 m      50.5 Ohms
Rx B   Derecha   3.3 m          24 m      50.6 Ohms
Rx C   Derecha   3.3 m          24 m      50.3 Ohms
Rx D   Derecha   3.3 m          24 m      56.4 Ohms
Rx E   Derecha   3.3 m          24 m      50.6 Ohms"	ryanque
Milestone 2013_10_1 JASMET - MST	1146	19 Dic 11:00 Medición de longitud de cables JASMET 50 MHz	JASMET		Antennas		new	2014-01-06T14:42:17-05:00	2014-01-07T11:31:39-05:00	"          Bajada    Longitud   Referencia  Impedancia
Canal A     8 m.     111.90 m    14 m.        51.4 Ohms
Canal B     8 m.     115.55 m    14 m.        55.8 Ohms
Canal C     8 m.      99.90 m    14 m.        51.2 Ohms
Canal D     8 m.     103.95 m    14 m.        51.3 Ohms
Canal E     8 m.      86.26 m    14 m.        51.2 Ohms
Referencia            87.85 m"	ryanque
Milestone 2013_10_1 JASMET - MST	1106	31 de Octubre 17:30 Lectura de Potencias	JASMET		Transmitters		new	2013-10-31T16:28:28-05:00	2013-10-31T16:28:28-05:00	"16:51 Crowbar por caida de voltaje
17:00
Tx1: 17 Kw <>+2.3 dBm
Tx3: 20 Kw <>+2.2 dBm
Voltaje de Linea: 4000 VAC, 300 Kw
17:30
Tx1: 17 Kw 
Tx3: 20 Kw 
Voltaje de Linea: 4000 VAC, 300 Kw"	vquesada
Milestone 2013_10_1 JASMET - MST	1105	31 de Octubre 16:00 Lectura de Potencias	ISR		Transmitters		new	2013-10-31T15:00:06-05:00	2013-10-31T15:00:06-05:00	"10:00
Tx1: 17 Kw 
Tx3: 20 Kw 
Votaje de Linea: 3900 VAC, 290 Kw
11:00
Tx1: 17 Kw <>+2.3 dBm
Tx3: 20 Kw <>+2.2 dBm
Voltaje de Linea: 3900 VAC, 295 Kw
11:14 Cae fuente de screen PA Tx1
12:00
Tx1: 17 Kw 
Tx3: 20 Kw 
Voltaje de Linea: 4000 VAC, 300 Kw
13:00
Tx1: 17 Kw <>+2.3 dBm
Tx3: 20 Kw <>+2.2 dBm
Voltaje de Linea: 4000 VAC, 300 Kw
14:00
Tx1: 17 Kw 
Tx3: 20 Kw 
Voltaje de Linea: 3950 VAC, 295 Kw
15:00
Tx1: 17 Kw <>+2.3 dBm
Tx3: 20 Kw <>+2.2 dBm
Voltaje de Linea: 4000 VAC, 300 Kw
16:00
Tx1: 17 Kw 
Tx3: 20 Kw 
Voltaje de Linea: 4000 VAC, 300 Kw
"	vquesada
Milestone 2013_10_1 JASMET - MST	1104	31 Oct 09:35 Lectura de Potencia	ISR		Transmitters		new	2013-10-31T08:32:53-05:00	2013-10-31T08:32:53-05:00	"31 de Octubre del 2013
05:30  LV ON
05:50  HV ON
06:00
Tx1: 14 Kw 
Tx3: 10 Kw 
Votaje de Linea: 3900 VAC, 295 Kw
06:10
Tx1: 17 Kw <>+2.5 dBm
Tx3: 20 Kw <>+2.5 dBm
Votaje de Linea: 3900 VAC, 295 Kw
07:00
Tx1: 17 Kw <>+2.8 dBm
Tx3: 21 Kw <>+2.6 dBm
Votaje de Linea: 3900 VAC, 295 Kw
08:00
Tx1: 18 Kw 
Tx3: 22 Kw 
Votaje de Linea: 3900 VAC, 295 Kw
09:00
Tx1: 17 Kw <>+2.5 dBm
Tx3: 21 Kw <>+2.4 dBm
Votaje de Linea: 3950 VAC, 295 Kw"	vquesada
Milestone 2013_10_1 JASMET - MST	1103	29 Oct 17:30 Lectura de Potencia	ISR		Transmitters		new	2013-10-30T16:26:39-05:00	2013-10-30T16:26:39-05:00	"30 de Octubre del 2013
15:00
Tx1: 17 Kw 
Tx3: 21 Kw 
Votaje de Linea: 3900 VAC, 290 Kw
16:00
Tx1: 18 Kw <>+2.7 dBm
Tx3: 22 Kw <>+2.7 dBm
Votaje de Linea: 3900 VAC, 290 Kw
17:00
Tx1: 17 Kw 
Tx3: 21 Kw 
Votaje de Linea: 3900 VAC, 300 Kw
17:30
Tx1: 18 Kw <>+2.5 dBm
Tx3: 22 Kw <>+2.5 dBm
Votaje de Linea: 3900 VAC, 300 Kw
"	vquesada
Milestone 2013_10_1 JASMET - MST	1101	29 Oct 17:35  Lectura de Potencia	ISR	Others	Transmitters		new	2013-10-30T13:12:03-05:00	2013-10-30T13:12:03-05:00	"29/10/2013

06:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         15      +1.75
         3         16.5         18      +1.8
07:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         18      +2.6
         3         16.5         20      +2.2
08:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         18      +2.6
         3         16.5         20      +2.2
09:25    Se deshabilita la RF
10:25    Se habilita la RF
10:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         16      +1.6   3860VAC 3F
         3         16.5         18      +1.8
11:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         15     
         3         16.5         17     
12:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         17      +2.2
         3         16.5         20      +2.4
12:10   Falla Screen PA3
13:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         18 
         3         16.5         20 
14:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         16      +1.6   3860VAC 3F
         3         16.5         18      +1.6
16:37    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5         16      +1.8   3850VAC 3F
         3         16.5         18      +1.7
17:00    TX       Fil      Pot(KW)  Pot(dBm)  
         1         16.5                 +2.0
         3         16.5                 +2.0
17:35    HV   (OFF)
17:50    LV    (ON)



"	rtadeo
Milestone 2013_10_1 JASMET - MST	1100	30 Oct 07:02 Se reinicia MST-Jasmet	JASMET		Acquisition system		new	2013-10-30T06:02:06-05:00	2013-10-30T06:02:06-05:00	Se reinicia la PC Ares porque se colgo. Volviendo ejecutar MST-Jasmet 50.	pcondor
Milestone 2013_10_1 JASMET - MST	1099	30 Oct 06:00 Se inicio MST-Jasmet50	JASMET		Start experiment		new	2013-10-30T05:19:00-05:00	2013-10-30T05:19:00-05:00	Se inicio MST_Jasmet 50 en la pc ARES.	pcondor
Milestone 2013_10_1 JASMET - MST	1098	28 Oct 15:50 Apagado de Digisonda	ISR		General		new	2013-10-28T14:46:53-05:00	2013-10-28T14:46:53-05:00	Se apagó la Digisonda por solicitud del Usuario Local, Danny Scipion.	ryanque
Milestone 2013_10_1 JASMET - MST	1097	28 Oct 12:40 Antena VSWR	ISR		Antennas		new	2013-10-28T09:38:06-05:00	2013-11-03T22:27:42-05:00	"The VSWR for the antenna is the following:

- WUP 1.06
- WDN 1.04
- NDN 1.07
- NUP 1.09
- EUP 1.01
- EDN 1.00
- SDN 1.01
- SUP 1.03"	ryanque
Milestone 2013_10_1 JASMET - MST	1096	28 Oct 12:00 Log for JASMET - MST	ISR		Start experiment		new	2013-10-28T09:36:07-05:00	2013-11-03T22:26:55-05:00	The log has been created	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1095	22 Oct 3:54 Se pone RF en EWDrift	ISR		Transmitters		new	2013-10-22T14:50:59-05:00	2013-10-22T14:50:59-05:00	"Se pone RF en EWDrift.
No se observa un cambio notable.
Observacion, el pase de la galaxia es a las 04:00 pm."	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1094	22 Oct 3:44 Se pone screen	ISR		Transmitters		new	2013-10-22T14:40:14-05:00	2013-10-22T14:40:14-05:00	"Se pone Voltaje de Screen a todos los TX's.
En Echotek sube un poco el nivel de coherencia del canal C y D alrededor de 0.03. El canal A y B sube un poco menos.
En JARS el nivel de coherencia baja del canal C y D alrededor de 0.03"	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1093	22 Oct 3:37 Se pone Voltaje de Placa	ISR		Start experiment		new	2013-10-22T14:33:38-05:00	2013-10-22T14:33:38-05:00	"Se pone placa a las 3:37.
No se incremento de nivel de coherencia."	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1092	22 Oct 3:30 Se pone cargas en las entradas de JARS	ISR		Acquisition system		new	2013-10-22T14:28:34-05:00	2013-10-22T14:28:34-05:00	"Como parte de las pruebas se pone cargas en las entradas de JARS.
A las 3:42 se retiran las cargas"	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1091	22 Oct 3:23 Solo se toma con JARS	ISR		Start experiment		new	2013-10-22T14:26:34-05:00	2013-10-22T14:26:34-05:00	"Se configura para tomar solo con JARS y descartar el tema de splitter y demas.
Se mantiene los mismos niveles."	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1090	22 Oct 3:18 Cambio canales A y B con C y D en JARS	ISR		Start experiment		new	2013-10-22T14:16:00-05:00	2013-10-22T14:16:00-05:00	"Se cambio los canales A y B con C y D en JARS debido a que la coherencia de C y D estaba mas alto.
Al realizar el cambio se paso al canal A y B
A las 15:21 se reestablece las conexiones."	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1089	22 Oct 15:01 Se enciende TX's con Voltaje de Bias y Filamento	ISR		Transmitters		new	2013-10-22T13:57:31-05:00	2013-10-22T15:45:45-05:00	Se enciende TX's con Voltaje de Bias y Filamento a las 15:01	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1088	22 Oct 2013 16:10 RTI	ISR		Plot		new	2013-10-22T13:50:05-05:00	2013-10-24T09:30:00-05:00	"Resumen de la prueba.
Inicio: 14:40
A las 15:20 se desconecta Echotek solo para ver JARS
A las 15:40 se conecta Echotek
A las 15:50 se finaliza el encendido del TX.

Observación el pase de la Galaxia ha sido a las 16:00"	ryanque
Milestone 2013_10 EW-Drift+Faraday Test	1087	22 Oct 14:30 Test Start for TX Calibration	ISR		Start experiment		new	2013-10-22T13:25:00-05:00	2013-10-22T15:44:42-05:00	"A las 14:30 se incia la prueba de calibracion de TX's.

A las 14:40 se enciende el sistema de enfriamiento.
"	ryanque
Milestone 2013_09_1 ISR+Imaging	1142	11 Dic 16:00 Se subieron datos a Madrigal	ISR+Imaging		Process/Analysis Program		new	2013-12-11T17:22:47-05:00	2013-12-11T17:22:47-05:00	Se subieron datos a Madrigal para 23 al 28 de setiembre.	pcondor
Milestone 2013_09_1 ISR+Imaging	1086	16 Oct  Datos subidos al PUMA	ISR+Imaging		General	Rita Abad	new	2013-10-16T16:43:28-05:00	2013-10-16T16:43:28-05:00	"Los datos de EW_Drift+Faraday+Imaging de la Campaña ISR+Imaging del 23-28 Setiembre 2013, ya se encuentran disponibles en el PUMA, en la siguiente dirección:

\\10.10.20.9\puma\Operaciones\DATA_Operaciones\2013_09\EW_Drift_Faraday_Imaging\
"	rabad
Milestone 2013_09_1 ISR+Imaging	1082	28 Sep 08:05 FIN del experimento EW_Drift+Faraday+Imaging	ISR+Imaging		End experiment		new	2013-10-03T16:24:05-05:00	2013-10-03T16:24:05-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1081	28 Sep 07:57 Se reinicia PC ARES	ISR+Imaging		Acquisition system		new	2013-10-03T16:14:02-05:00	2013-10-03T16:14:02-05:00	Se reinicia adquisición.	rabad
Milestone 2013_09_1 ISR+Imaging	1080	28 Sep 04:52 Calibración de ATR's y TR's	ISR+Imaging		Spark Gaps	A. Belleza	new	2013-10-03T16:13:03-05:00	2013-10-03T16:13:03-05:00	Ajuste de chisperos.	rabad
Milestone 2013_09_1 ISR+Imaging	1079	28 Sep 01:10 Se apaga Imaging+Driver	ISR+Imaging		General		new	2013-10-03T16:10:18-05:00	2013-10-03T16:10:18-05:00	Debido a que no hay Spread-F se para experimento Imaging+Driver (Sistema de adquisición JARS).	rabad
Milestone 2013_09_1 ISR+Imaging	1078	27 Sep 23:06 Ajuste ATR's y TR's	ISR+Imaging		Spark Gaps		new	2013-10-03T16:06:03-05:00	2013-10-03T16:06:03-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1077	27 Sep 13:45 Ajuste de ATR's y TR's	ISR+Imaging		Transmitters		new	2013-10-03T16:03:56-05:00	2013-10-03T16:03:56-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1076	27 Sep 10:29 Ajuste de ATR's y TR's	ISR+Imaging		Spark Gaps		new	2013-10-03T16:02:50-05:00	2013-10-03T16:02:50-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1075	27 Sep 05:00 Problemas en transmisores	ISR+Imaging		Transmitters		new	2013-10-03T16:01:54-05:00	2013-10-03T16:01:54-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1074	26 Set 22:58 Problemas en transmisores	ISR+Imaging		Transmitters		new	2013-10-03T15:07:25-05:00	2013-10-03T15:19:08-05:00	Caída de tensión	rabad
Milestone 2013_09_1 ISR+Imaging	1073	26 Set 20:00 Problemas de transmisores	ISR+Imaging		Transmitters		new	2013-10-03T15:06:36-05:00	2013-10-03T15:06:36-05:00	Caída de tensión	rabad
Milestone 2013_09_1 ISR+Imaging	1072	26 Set 19:16 Falla en transmisores	ISR+Imaging		Transmitters		new	2013-10-03T15:05:45-05:00	2013-10-03T15:20:04-05:00	Problemas con la fuente de alta tensión.	rabad
Milestone 2013_09_1 ISR+Imaging	1071	26 Set 19:15 Se apaga VIPIR	ISR+Imaging		Other Instruments		new	2013-10-03T15:04:26-05:00	2013-10-03T15:04:26-05:00	Se ve interferencia proveniente de VIPIR, en la data de los experimentos.	rabad
Milestone 2013_09_1 ISR+Imaging	1070	26 Set 17:46 Ajustes de chisperos ATR´s y TR's	ISR+Imaging		Spark Gaps		new	2013-10-03T15:02:14-05:00	2013-10-03T15:02:14-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1069	26 Set 16:53 Se reinicia la adquisición en PC ARES	ISR+Imaging		Acquisition system		new	2013-10-03T15:01:26-05:00	2013-10-03T15:01:26-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1068	26 Set 16:33 Problemas con la PC-ARES	ISR+Imaging		Acquisition system		new	2013-10-03T15:00:23-05:00	2013-10-03T15:00:23-05:00	Se cuelga PC ARES.	rabad
Milestone 2013_09_1 ISR+Imaging	1067	26 Set 16:20 Se detiene adquisición en Imaging	ISR+Imaging		Acquisition system		new	2013-10-02T16:32:55-05:00	2013-10-02T16:32:55-05:00	-Se detiene la toma de datos en Imaging para cambiar el número de perfiles adquiridos por bloques.	rabad
Milestone 2013_09_1 ISR+Imaging	1066	26 Set 16:00 Se inicia experimento Imaging+Driver	ISR+Imaging		Start experiment		new	2013-10-02T16:29:33-05:00	2013-10-02T16:29:33-05:00		pcondor
Milestone 2013_09_1 ISR+Imaging	1065	26 set 13:42 Ajuste chisperos ATR´s y TR´s	ISR+Imaging		Spark Gaps		new	2013-10-02T16:28:37-05:00	2013-10-02T16:28:37-05:00		pcondor
Milestone 2013_09_1 ISR+Imaging	1064	26 Set 10:42 Falla de transmisores	ISR+Imaging		Transmitters		new	2013-10-02T16:27:26-05:00	2013-10-02T16:27:26-05:00		pcondor
Milestone 2013_09_1 ISR+Imaging	1063	26 Set 10:24 Falla de transmisores	ISR+Imaging		Transmitters		new	2013-10-02T16:01:50-05:00	2013-10-02T16:01:50-05:00		pcondor
Milestone 2013_09_1 ISR+Imaging	1062	26 Set 09:59 Falla en transmisores	ISR+Imaging		Transmitters		new	2013-10-02T15:43:01-05:00	2013-10-02T15:43:01-05:00		pcondor
Milestone 2013_09_1 ISR+Imaging	1061	26 Set 09:27 Ajuste de chisperos ATR´s y TR´s	ISR+Imaging		Spark Gaps		new	2013-10-02T15:08:21-05:00	2013-10-02T15:08:21-05:00		pcondor
Milestone 2013_09_1 ISR+Imaging	1060	26 Set 05:48 Ajustes de chisperos ATRs y TRs	ISR+Imaging		Antennas	J Lavado	new	2013-10-01T16:36:02-05:00	2013-10-01T16:36:02-05:00	Ajustes de chisperos ATRs y TRs	pcondor
Milestone 2013_09_1 ISR+Imaging	1059	26 Set 03:00 Se para Imaging	ISR+Imaging		Acquisition system	P Condor	new	2013-10-01T16:35:22-05:00	2013-10-01T16:35:22-05:00	Se para Imaging cuando ya termino el Spread F	pcondor
Milestone 2013_09_1 ISR+Imaging	1058	26 Set 01:30 Ajustes de chisperos ATRs y TRs	ISR+Imaging		Antennas	J Lavado	new	2013-10-01T16:33:10-05:00	2013-10-01T16:33:10-05:00	Ajustes de chisperos ATRs y TRs	pcondor
Milestone 2013_09_1 ISR+Imaging	1057	25 set 21:15 Ajustes de chisperos ATRs y TRs	ISR+Imaging		Antennas	J Lavado	new	2013-10-01T16:31:54-05:00	2013-10-01T16:31:54-05:00	Ajustes de chisperos ATRs y TRs	pcondor
Milestone 2013_09_1 ISR+Imaging	1056	28 Set 07:45 Lectura de potencias	ISR+Imaging		Transmitters		new	2013-09-28T08:30:10-05:00	2013-10-01T17:11:33-05:00	"00:00
TX1 8 KW <> 1.1 dBm
TX2 7 KW <> 1.2 dBm
TX3 19 KW <> 5.2 dBm
D4 -8.1 dBm
Línea: 3950 VAC - 310 KW

01:00 
TX1 8 KW
TX2 7 KW
TX3 19 KW 
D4 -8.1 dBm
Línea: 3950 VAC - 300 KW

01:10 D4 OFF

02:00
TX1 8 KW <> 1.1 dBm
TX2 6 KW <> 1.1 dBm
TX3 20 KW <> 5.2 dBm
Línea: 4000 VAC - 320 KW

03:00
TX1 8 KW
TX2 7 KW
TX3 20 KW 
Línea: 3980 VAC - 310 KW

04:00
TX1 7 KW
TX2 7 KW
TX3 19 KW 
Línea: 3900 VAC - 310 KW

05:00
TX1 8 KW
TX2 7 KW
TX3 19 KW 
Línea: 4000 VAC - 320 KW

06:00
TX1 7 KW
TX2 7 KW
TX3 19 KW 
Línea: 3950 VAC - 310 KW

07:00
TX1 8 KW <> 1.2 dBm
TX2 7 KW <> 1.3 dBm
TX3 19 KW <> 5.2 dBm
Línea: 3980 VAC - 320 KW
"	ryaya
Milestone 2013_09_1 ISR+Imaging	1055	27 Set 23:00 Lectura de potencias	ISR+Imaging		Transmitters		new	2013-09-28T08:20:55-05:00	2013-10-01T17:12:01-05:00	"20:00
TX1 8 KW <> 1.1 dBm
TX2 7 KW <> 1.2 dBm
TX3 19 KW <> 5.2 dBm
D4 -8 dBm
Línea: 4000 VAC - 320 KW
21:00 
TX1 7 KW
TX2 7 KW
TX3 18 KW 
D4 -8.1 dBm
Línea: 3950 VAC - 310 KW
22:00
TX1 7 KW <> 1 dBm
TX2 7 KW <> 1.2 dBm
TX3 18 KW <> 5 dBm
D4 -8.2 dBm
Línea: 3930 VAC - 300 KW
23:00
TX1 7 KW
TX2 7 KW
TX3 18 KW 
D4 -8.1 dBm
Línea: 3860 VAC - 300 KW
"	ryaya
Milestone 2013_09_1 ISR+Imaging	1054	27 Sep 19:41 AJUSTE ATR'S Y TR'S	ISR+Imaging		Spark Gaps	wrojas	assigned	2013-09-27T20:16:40-05:00	2013-10-01T17:12:21-05:00	AJUSTE DE LOS ATR'S Y TR'S	avaldez
Milestone 2013_09_1 ISR+Imaging	1053	27 Sep 16:50 AJUSTE ATR'S Y TR'S	ISR+Imaging		Spark Gaps	wrojas	assigned	2013-09-27T20:16:07-05:00	2013-10-01T17:12:33-05:00	AJUSTE DE LOS ATR'S Y TR'S	avaldez
Milestone 2013_09_1 ISR+Imaging	1052	27 Sep 16:00 INICIA ADQUISICION PC_JARS	ISR+Imaging		Start experiment	avaldez	assigned	2013-09-27T20:15:17-05:00	2013-10-01T17:12:55-05:00	-Inicia adquisicion PC_JARS(Imaging).	avaldez
Milestone 2013_09_1 ISR+Imaging	1051	27 Sep 19:00 Lectura de Potencia	ISR+Imaging		Transmitters		new	2013-09-27T19:27:03-05:00	2013-10-01T17:13:08-05:00	"27 de Setiembre 2013
08:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.6 dBm
Línea: 4000 VAC-320 Kw
09:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.6 dBm
Línea: 4000 VAC-320 Kw
10:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.6 dBm
Línea: 4000 VAC-320 Kw
11:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.6 dBm
Línea: 4000 VAC-320 Kw
12:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.5 dBm
Línea: 4000 VAC-320 Kw
13:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.5 dBm
Línea: 4000 VAC-320 Kw
14:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.5 dBm
Línea: 4000 VAC-320 Kw
15:00
TX1 9 KW <>+1.5 dBm
TX2 11 KW<>+5.1 dBm
TX3 20 KW<>+5.1 dBm
Línea: 4000 VAC-320 Kw
16:00
TX1 8 KW <>+1.1 dBm
TX2 7 KW <>+1.2 dBm
TX3 19 KW<>+5.3 dBm
D4         -8.0 dBm
Línea: 3900 VAC-310 Kw
17:00
TX1 8 KW <>+1.1 dBm
TX2 7 KW <>+1.2 dBm
TX3 19 KW<>+5.3 dBm
D4         -8.0 dBm
Línea: 3900 VAC-310 Kw
18:00
TX1 8 KW <>+1.1 dBm
TX2 7 KW <>+1.2 dBm
TX3 19 KW<>+5.3 dBm
D4         -8.0 dBm
Línea: 3900 VAC-310 Kw
19:00
TX1 8 KW <>+1.1 dBm
TX2 7 KW <>+1.2 dBm
TX3 19 KW<>+5.3 dBm
D4         -8.0 dBm
Línea: 4000 VAC-320 Kw
"	vquesada
Milestone 2013_09_1 ISR+Imaging	1050	27 Sep 07:30 Lectura de Potencia	ISR+Imaging	Others	Transmitters		new	2013-09-27T07:34:54-05:00	2013-10-01T17:13:30-05:00	"
26/09/2013

20:00
TX1:  8kW 
TX2:  7kw
TX3:  19kw
D4:  -8dBm
4000VAC 310kw
21:00
TX1:  7kW <>+1.2dBm
TX2:  7kw <>+1.6dBm
TX3:  18kw<>-5.2dBm
D4:  -8dBm
3990VAC 310kw
22:00
TX1:  8kW 
TX2:  7kw 
TX3:  18kw
D4: -8dBm
3950VAC 310kw
22:50
Caída en la alta(HV) por sobre voltaje en la línea AC.
23:08 Se Reanuda la Transmisión.
TX1:  8kW <>+1.3dBm
TX2:  7kw <>+1.6dBm
TX3:  18kw<>+5.5dBm
D4: -8dBm
4000VAC 310kw
23:15 Falla Screen PA1

27/09/2013
00:00
TX1:  8kW 
TX2:  7kw 
TX3:  20kw
D4: -8dBm
4000VAC 310kw
01:00
TX1:  8kW <>+1.3dBm
TX2:  6kw <>+1.3dBm
TX3:  19kw<>-5.4dBm
D4: se Apaga (OFF)
3990VAC 310kw
01:55
TX2:  10Kw<>+5dBm
02:00
TX1:  8kW  <>+1.3dBm
TX2:  10kw <>+5.0dBm
TX3:  19kw <>+5.4dBm
3990VAC 310kw
03:00
TX1:  8kW 
TX2:  6kw 
TX3:  20kw
4000VAC 310kw
04:00
TX1:  8kW <>+1.0dBm
TX2:  10kw <>+5.0dBm
TX3:  19kw<>+5.2dBm
3950VAC 310kw
05:00
TX1:  8kW <>+1.2dBm
TX2:  10kw <>+5.0dBm
TX3:  19kw<>+5.2dBm
3950VAC 310kw
05:00
Falla de Screen Drv1
06:00
TX1:  7kW 
TX2:  10kw
TX3:  18kw
3950VAC 310kw
07:00
TX1:  7kW  <>+1.2dBm
TX2:  10kw <>+4.9dBm
TX3:  18kw <>+5.3dBm
3940VAC 310kw















"	rtadeo
Milestone 2013_09_1 ISR+Imaging	1049	27 Set 06:20 Calibración de ATR's y TR's	ISR+Imaging		Spark Gaps		new	2013-09-27T06:48:32-05:00	2013-10-01T17:14:17-05:00		imanay
Milestone 2013_09_1 ISR+Imaging	1048	27 Set 04:36 Problemas con programa de adquisición de Faraday	ISR+Imaging		Start experiment	I. Manay	new	2013-09-27T05:08:36-05:00	2013-10-01T17:14:03-05:00	Perdida de sincronismo de los datos. El batch de Faraday fue reiniciado dos veces.	imanay
Milestone 2013_09_1 ISR+Imaging	1047	27 Set 01:53 RF hacia TX	ISR+Imaging		General	I. Manay	new	2013-09-27T02:45:24-05:00	2013-10-01T17:14:32-05:00	Conexión manual en sala de Operaciones del RF pulsado (RF2 de DDS de EW_Drift) hacia sala de TX (TX2). Se estuvo sin esta conexión por un lapso de 1 hora después del apagado del sistema de Imaging.	imanay
Milestone 2013_09_1 ISR+Imaging	1046	27 Set 00:54 Se apaga sistema JARS	ISR+Imaging		Acquisition system	I. Manay	new	2013-09-27T01:25:27-05:00	2013-10-03T15:22:53-05:00	No hubo más F-dispersa, por eso se detuvo experimento Imaging y se apagaron todos los equipos: controlador de radar, dds y JARS.	imanay
Milestone 2013_09_1 ISR+Imaging	1045	27 Set 00:30 Plots EW_Drift	ISR+Imaging		Plot	I. Manay	new	2013-09-27T00:59:39-05:00	2013-10-01T17:15:08-05:00		rabad
Milestone 2013_09_1 ISR+Imaging	1044	27 Set 00:05 Calibración de ATR's y TR's	ISR+Imaging		Spark Gaps		new	2013-09-27T00:52:42-05:00	2013-10-01T17:16:02-05:00		imanay
Milestone 2013_09_1 ISR+Imaging	1043	26 Set 23:30 Problemas con Signal Chain	ISR+Imaging		Process/Analysis Program	I. Manay	new	2013-09-27T00:46:19-05:00	2013-10-01T17:16:16-05:00	Se detuvo el gui de Signal Chain. No se pudo reponer el script de procesamiento.	imanay
Milestone 2013_09_1 ISR+Imaging	1042	26 Set 22:55 Cambio en parámetros de adquisición de JARS	ISR+Imaging		Plot	I. Manay	new	2013-09-27T00:38:03-05:00	2013-10-01T17:16:29-05:00	La cantidad de bloques por archivo fue cambiada de 400 a 200 para reducir el tamaño de los archivos .r transferidos a la PC Signal Chain (Aprox. 800M). Después de este cambio, se pudo continuar con la visualización de los gráficos del experimento Imaging usando el gui de Signal Chain.	imanay
Milestone 2013_09_1 ISR+Imaging	1041	26 Set 20:40 Problemas con Signal Chain para visualizar Imaging	ISR+Imaging		Plot	I. Manay	new	2013-09-27T00:03:47-05:00	2013-10-01T17:16:47-05:00		imanay
Milestone 2013_09_1 ISR+Imaging	1040	26 Set 23:00 Problema con TX	ISR+Imaging		Transmitters	I. Manay	new	2013-09-26T23:50:53-05:00	2013-10-01T17:17:01-05:00	Se repone el TX después de un problema de sobretension en la línea.	imanay
Milestone 2013_09_1 ISR+Imaging	1039	26 Set 19:34 Lectura de Potencias	ISR+Imaging		Transmitters		new	2013-09-26T19:58:22-05:00	2013-10-01T17:17:17-05:00	"14:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.3 dBm
TX3 20 KW <>5.2 dBm
Línea: 3950 VAC - 310 Kw
15:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>5.3 dBm
TX3 20 KW <>5.2 dBm
Línea: 3950 VAC - 310 Kw
16:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>1.3 dBm
TX3 20 KW <>5.2 dBm
D4 On      -8.0 dBm
17:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>1.3 dBm
TX3 20 KW <>5.2 dBm
D4 On      -8.0 dBm
18:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>1.3 dBm
TX3 20 KW <>5.2 dBm
D4 On      -8.0 dBm
Línea: 3900 VAC - 310 Kw
19:00
TX1 9 KW <>1.6 dBm
TX2 11 KW <>1.3 dBm
TX3 20 KW <>5.2 dBm
D4 On      -8.0 dBm
19:16 Crowbar por caida de tension
19:32 Cae fuente de screen PA Tx1"	vquesada
Milestone 2013_09_1 ISR+Imaging	1038	26 Sep 09:27 Calibraci'on de TR's y ATRS	ISR+Imaging		Spark Gaps	A. Coronado	new	2013-09-26T19:55:26-05:00	2013-10-01T17:17:31-05:00	Ajuste de chisperos	rabad
Milestone 2013_09_1 ISR+Imaging	1037	26 Set 19:45 Lectura de Potencias	ISR+Imaging		Transmitters		new	2013-09-26T13:35:24-05:00	2013-10-01T17:17:45-05:00	"08:00
TX1 9 KW  <>1.6 dBm
TX2 11 KW <>5.0 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
09:00 
TX1 9 KW  <>1.6 dBm
TX2 11 KW <>5.0 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
09:59 a 10:15 Falla interloock de Tx1 por que deja de funcinar ventilador de filamento
10:00
TX1 8 KW <> 1.3 dBm
TX2 10 KW <> 5.0 dBm
TX3 18 KW <> 5.0 dBm
Línea: 3900 VAC - 310 Kw
10:28 y 10:45 Cae fuente de screen PA Tx1
11:00
TX1 9 KW  <>1.6 dBm
TX2 11 KW <>5.3 dBm
TX3 19 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
12:00
TX1 9 KW  <>1.6 dBm
TX2 11 KW <>5.0 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw
13:00
TX1 9 KW  <>1.6 dBm
TX2 11 KW <>5.3 dBm
TX3 20 KW <>5.2 dBm
Línea: 3900 VAC - 310 Kw"	vquesada
Milestone 2013_09_1 ISR+Imaging	1036	26 Sep 07:30 Lectura de Potencia	ISR+Imaging	Others	Transmitters		new	2013-09-26T08:19:42-05:00	2013-10-01T17:18:00-05:00	"25 de Setiembre
 20:00
 Tx1 8 Kw <> +1.2 dBm
 Tx2 7 Kw <> +1.1 dBm 
 Tx3 19 Kw <>+5 dBm
 Driver 4 <>-8.1dBm
 3880 Vac,310 Kw
 21:00
 Tx1 8 Kw <> +1.5 dBm
 Tx2 7 Kw <> +1.2 dBm 
 Tx3 20 Kw <>+4.3 dBm
 Driver 4 ON -8.0 dBm
 22:00
 Tx1 8 Kw <> +1.3 dBm
 Tx2 7 Kw <> +1.4 dBm 
 Tx3 19 Kw <>+5.3 dBm
 Driver 4 -8.0
 3920 Vac,310 Kw
 23:00
 Tx1 8 Kw 
 Tx2 7 Kw  
 Tx3 20 Kw 
 Driver 4 -8.0 dBm
 
26 de Setiembre
 00:00
 Tx1 8 Kw <> +1.32 dBm
 Tx2 7 Kw <> +4.4 dBm 
 Tx3 20 Kw <>+5.3 dBm
 Driver 4 <>-8.0 dBm
 3920 Vac,310 Kw
 01:00
 Tx1 8 Kw  
 Tx2 7 Kw   
 Tx3 20 Kw 
 Driver 4 ON -8.1 dBm
 02:00
 Tx1 8 Kw <> +1.2 dBm
 Tx2 7 Kw <> +4.3 dBm 
 Tx3 19 Kw <>+5.2 dBm
 Driver 4 -8.0
 3900 Vac,310 Kw
 03:00
 Tx1 7 Kw 
 Tx2 8 Kw  
 Tx3 19 Kw 
 Driver 4 -8.0 dBm
 03:02 Se Deshabilita RF de Driver 4
 04:00
 Tx1 8 Kw <> +1.3 dBm
 Tx2 7 Kw <> +4.4 dBm 
 Tx3 19 KW <>+5.3 dBm
 3920VAC 310Kw
 05:00
 Tx1 8 Kw 
 Tx2 7 Kw  
 Tx3 19 Kw 
 06:00
 Tx1 8 Kw 
 Tx2 8 Kw  
 Tx3 19 KW
 07:00
 Tx1 8 Kw +1.6 dBm
 Tx2 10 KW +5 dBm  
 Tx3 20 Kw +5.4 dBm
 3990VAC 310KW





"	rtadeo
Milestone 2013_09_1 ISR+Imaging	1035	25 Set 19:45 Lectura de potencias	ISR+Imaging		Transmitters		new	2013-09-25T20:21:16-05:00	2013-10-01T17:18:15-05:00	"08:00
TX1  8 KW
TX2 10 KW
TX3 15 KW 
Línea: 3900 VAC - 300 KW

09:00 Ajuste de sintonía PA 3
TX1  8 KW
TX2 10 KW
TX3 19 KW 
Línea: 3950 VAC - 310 KW

10:00
TX1  6 KW  <> 1.2 dBm
TX2  9 KW  <> 4.7 dBm
TX3 117 KW <> 5.2 dBm
Línea: 3880 VAC - 300 KW

11:00
TX1  8 KW
TX2 10 KW
TX3 18 KW 
Línea: 3860 VAC - 300 KW

12:00
TX1  8 KW
TX2 11 KW
TX3 20 KW 
Línea: 4000 VAC - 320 KW

13:30 Se activa ventilador principal 2
TX1  7 KW <> 1.2 dBm
TX2  9 KW <> 4.7 dBm
TX3 17 KW <> 5 dBm

14:00
TX1  8 KW
TX2 10 KW
TX3 18 KW 
Línea: 3880 VAC - 310 KW

15:00
TX1  8 KW <> 1.2 dBm
TX2  9 KW <> 4.7 dBm
TX3 17 KW <> 5 dBm

16:00
TX1  8 KW
TX2 10 KW
TX3 18 KW 
Línea: 3850 VAC - 310 KW

16:45 Se activa Driver 4 (Imagenes)

17:00
TX1  7 KW
TX2  6 KW
TX3 17 KW
D4  -8.2 dBm  

18:00
TX1  7 KW <> 1.2 dBm
TX2  6 KW <> 1.1 dBm
TX3 18 KW <> 5 dBm
D4  -8.2 dBm 
Línea: 3880 VAC - 310 KW

19:00
TX1  8 KW
TX2  7 KW
TX3 20 KW
D4  -7.8 dBm 



 




 "	ryaya
Milestone 2013_09_1 ISR+Imaging	1034	25 Sep  06:42  CALIBRACION ATR's Y TR's	ISR+Imaging		Spark Gaps		new	2013-09-25T07:35:41-05:00	2013-10-01T17:18:30-05:00	Se realiza la calibración de los ATR's y TR's	avaldez
Milestone 2013_09_1 ISR+Imaging	1033	25 Setiembre 2013 Lectura de Potencias	ISR+Imaging		Transmitters		new	2013-09-25T07:32:36-05:00	2013-10-01T17:18:44-05:00	"25 de Setiembre 
00:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
01:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
01:12 y 01:56 fallo la sincronizacion 
02:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
03:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
03:25 crowbar por caida de tension
04:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
05:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
06:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
07:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +4.8 dBm (M)
Tx3 15 Kw <>+4.3 dBm
4000 Vac,300 Kw
"	vquesada
Milestone 2013_09_1 ISR+Imaging	1032	25 Sep  03:25 CAIDA  DE TRANSMISORES POR DISMINUCION DE LA  TENSION	ISR+Imaging		Transmitters		new	2013-09-25T04:02:03-05:00	2013-10-01T17:19:00-05:00	OCURRIO UNA CAIDA EN LA TENSION DURANTE UNOS MINUTOS  , SE VOLVIO A HABILITAR EL ALTO VOLTAJE Y SE CONTINUA CON EL EXPERIMENTO	avaldez
Milestone 2013_09_1 ISR+Imaging	1031	25 Sep  02:38  CALIBRACION ATR's Y TR's	ISR+Imaging		Spark Gaps		new	2013-09-25T03:12:58-05:00	2013-10-01T17:19:15-05:00	Se realiza la calibracion de los ATR's y TR's	avaldez
Milestone 2013_09_1 ISR+Imaging	1030	25 Sep  01:56  REINICIO DE ADQUISICIÓN EW_DRIFT+FARADAY+IMAGING	ISR+Imaging		Acquisition system		new	2013-09-25T03:09:58-05:00	2013-10-01T17:19:36-05:00	"SE EJECUTA EL PROGRAMA DE CONFIGURACION PULSE DESIGN, se procede a ejecutar el batch pero generaba errores.Se ejecuto el programa DP.racp y se uso la opcion acquiere 2_5_2.
El programa de adquisicion funciona correctamente y se vuelve a ejecutar el programa de Procesamiento
ew_drifts_23set2013.pro. Se continua con la toma de datos correctamente"	avaldez
Milestone 2013_09_1 ISR+Imaging	1029	25 Sep  01:06  Desincronización de PC EW_DRIFT+FARADAY+IMAGIN	ISR+Imaging		Acquisition system		new	2013-09-25T03:01:32-05:00	2013-10-01T17:19:52-05:00	"Se detiene la adquisicion de EW_DRIFT+FARADAY+IMAGING por problemas en el controlador de radar.
Se apagan transmisores y se procede a configurar y ejecutar la aplicación.
"	avaldez
Milestone 2013_09_1 ISR+Imaging	1028	24 Sep  22:40  CALIBRACION ATR's Y TR's	ISR+Imaging		Spark Gaps		new	2013-09-25T02:38:08-05:00	2013-10-01T17:20:07-05:00	Se realiza la calibracion de los ATR's y TR's.	avaldez
Milestone 2013_09_1 ISR+Imaging	1027	24 Sep  22:40  CALIBRACION ATR's Y TR's	ISR+Imaging		Spark Gaps		new	2013-09-25T02:32:48-05:00	2013-10-01T17:20:20-05:00	Se realiza la calibracion de los ATR's y TR's.	avaldez
Milestone 2013_09_1 ISR+Imaging	1026	24 Setiembre 2013 Lectura de Potencias	ISR+Imaging		Transmitters		new	2013-09-24T23:33:02-05:00	2013-10-01T17:20:36-05:00	"24 de Setiembre
20:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +1.2 dBm 
Tx3 15 Kw <>+4.3 dBm
Driver 4 off
4000 Vac,300 Kw
21:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +1.2 dBm 
Tx3 15 Kw <>+4.3 dBm
Driver 4 ON -7.8 dBm
4000 Vac,300 Kw
22:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +1.2 dBm 
Tx3 15 Kw <>+4.3 dBm
Driver 4   -7.8
4000 Vac,300 Kw
23:00
Tx1 9 Kw <> +1.5 dBm
Tx2 7 Kw <> +1.2 dBm 
Tx3 15 Kw <>+4.3 dBm
Driver 4    -7.8 dBm
4000 Vac,300 Kw"	vquesada
Milestone 2013_09_1 ISR+Imaging	1025	24 Set 07:00 Falta habilitar hito del experimento EW Drift+Faraday+Imaging driver	ISR+Imaging		General	D. Cordova	new	2013-09-24T08:31:17-05:00	2013-10-01T17:20:52-05:00	Falta habilitar hito del experimento EW Drift+Faraday+Imaging driver, no se sta colocando este para colocarlo cuando se habilite	dcordova
Milestone 2013_09_1 ISR+Imaging	1024	24 de Setiembte 2013 Lectura de Potencia	ISR+Imaging		Transmitters		new	2013-09-24T07:36:12-05:00	2013-10-01T17:21:09-05:00	"04:00
Tx1 9 Kw <> +1.4 dBm
Tx2 9 Kw <> +4.5 dBm (Max.)
Tx3 15 Kw <> +4.2 dB
Driver 4 -11.5 dBm
4000 Vac,300 Kw
05:00
Tx1 9 Kw <> +1.4 dBm
Tx2 9 Kw <> +4.5 dBm (Max.)
Tx3 15 Kw <> +4.2 dB
Driver 4 -11.5 dBm
4000 Vac,300 Kw
06:00
Tx1 9 Kw <> +1.4 dBm
Tx2 9 Kw <> +4.5 dBm (Max.)
Tx3 15 Kw <> +4.2 dB
Driver 4 -11.5 dBm
4000 Vac,300 Kw
07:00
Tx1 9 Kw <> +1.4 dBm
Tx2 9 Kw <> +4.5 dBm (Max.)
Tx3 15 Kw <> +4.2 dB
Driver 4 -11.5 dBm
4000 Vac,300 Kw"	vquesada
Milestone 2013_09_1 ISR+Imaging	1023	24 Set 06:20 Mensaje de error en el logbook	ISR+Imaging		General	D. Cordova	new	2013-09-24T06:51:06-05:00	2013-10-01T17:21:24-05:00	"Se observa que la carga de mensajes en el logbook es lenta (aprox. 50 seg) y se genera el siguiente mensaje de error:

Warning: The ticket has been created, but an error occurred while sending notifications: Connection unexpectedly closed"	dcordova
Milestone 2013_09_1 ISR+Imaging	1022	24 Set 01:50 Caida de transmisores por bajada en la tension de linea	ISR+Imaging		Start experiment	D. Cordova	new	2013-09-24T06:47:48-05:00	2013-10-01T17:21:38-05:00	Cayeron los transmisores y se levantaron de nuevo, la causa fue la disminucion en la tension de 4160VAC	dcordova
Milestone 2013_09_1 ISR+Imaging	1021	24 Set 01:45 Caida de transmisores por bajada en la tension de linea	ISR+Imaging		Transmitters	D. Cordova	new	2013-09-24T06:45:37-05:00	2013-10-01T17:21:59-05:00	Cayeron los transmisores y se levantaron de nuevo, la causa fue una disminucion en la tension de 4160V	dcordova
Milestone 2013_09_1 ISR+Imaging	1020	24 Set 04:18 Ajuste de chisperos de los ATR's y TR's	ISR+Imaging		Start experiment	A. Coronado	new	2013-09-24T06:36:36-05:00	2013-10-01T17:10:20-05:00		dcordova
Milestone 2013_09_1 ISR+Imaging	1019	24 Set 00:10 Ajuste de chisperos de los ATR's y TR's	ISR+Imaging		Spark Gaps	A. Coronado	new	2013-09-24T06:34:28-05:00	2013-10-01T17:04:58-05:00		dcordova
Milestone 2013_09_1 ISR+Imaging	1018	24 Set 00:00 Detiene sistema de adquisicion JARS	ISR+Imaging		Acquisition system	D. Cordova	new	2013-09-24T06:28:16-05:00	2013-10-01T17:05:21-05:00	Se detiene sistema de adquisicion de JARS y se conecta pulso RF 2	dcordova
Milestone 2013_09_1 ISR+Imaging	1017	23 Set 23:30 Problemas con los links de visualizacion de la pagina web	ISR+Imaging		Start experiment	D. Cordova	new	2013-09-24T06:24:01-05:00	2013-10-01T17:05:46-05:00	"Se observa el mensaje ""RADAR POWER OFF"" en la pagina web de Realtime Time Processing, se trato de comunicar con P. Bravo pero no se pudo, contacte a P. Condor, le indique el error pero a partir de las 12:00, se arreglo el problema: actualmente se generan los links y el mensaje es ""RADAR POWER ON"" "	dcordova
Milestone 2013_09_1 ISR+Imaging	1016	23 Set 22:20 Demora en la actualizacion de imagenes generadas en Signal Chain	ISR+Imaging		Process/Analysis Program	D. Cordova	new	2013-09-24T06:16:42-05:00	2013-10-01T17:06:06-05:00	La hora del grafico generado se ha detenido y no actualiza graficos; ademas solo se observa un grafico, por ello se detuvo y corto el programa. Luego, se volvio a correr el programa (segun el manual, se coordino con Daniel Suarez) y se generaron los 3 graficos actualizados	dcordova
Milestone 2013_09_1 ISR+Imaging	1015	23 Set 22:20 Demora en la actualizacion de imagenes generadas en Signal Chain	ISR+Imaging		Process/Analysis Program	D. Cordova	new	2013-09-24T06:16:14-05:00	2013-10-01T17:06:28-05:00	La hora del grafico generado se ha detenido y no actualiza graficos; ademas solo se observa un grafico, por ello se detuvo y corto el programa. Luego, se volvio a correr el programa (segun el manual) y se generaron los 3 graficos actualizados	dcordova
Milestone 2013_09_1 ISR+Imaging	1014	23 Set 22:00 Diferencia de ruido en los canales de JARS	ISR+Imaging		Reception	D. Cordova	new	2013-09-24T06:08:39-05:00	2013-10-01T17:06:48-05:00	Se observa diferencia de ruido en los canales de JARS, esto se debe a que aun falta conectar los atenuadores	dcordova
Milestone 2013_09_1 ISR+Imaging	1013	23 Set 21:30 Interferencia por falta de sincronismo con VIPIR	ISR+Imaging		Other Instruments	D. Cordova	assigned	2013-09-24T06:00:42-05:00	2013-10-01T17:07:11-05:00	Se tiene problema de sincronismo con VIPIR, se fue a VIPIR y se apago el transmisor, luego se observa que desaparece las interferencias	dcordova
Milestone 2013_09_1 ISR+Imaging	1011	23 Set 12:00 Imagenes de los datos procesados	ISR+Imaging		Process/Analysis Program	dcordova	new	2013-09-24T00:58:08-05:00	2013-10-01T17:07:41-05:00		dcordova
Milestone 2013_09_1 ISR+Imaging	1010	24 de Setiembre 2013 Lectura de Potencia	ISR+Imaging		Transmitters		new	2013-09-24T00:53:41-05:00	2013-10-01T17:08:29-05:00	"23 Setiembre 2013
20:50
Tx1 6 Kw  <>  -0.1 dBm
Tx2 10 Kw <> +4.2 dBm
Tx3 13 Kw <> +4.8 dB
Driver 4    -11.8 dBm
21:30
Tx1 7 Kw  <>  -0.1 dBm
Tx2 10 Kw <> +4.8 dBm
Tx3 13 Kw <> +4.8 dB
Driver 4    -11.8 dBm
22:00
Tx1 6 Kw  <> -0.1 dBm
Tx2 6 Kw  <> +0.5 dBm
Tx3 15 Kw <> +4.0 dB
Driver 4    -11.8 dBm
23:00
Tx1 6 Kw  <> -0.1 dBm
Tx2 6 Kw  <> +0.5 dBm
Tx3 15 Kw <> +4.0 dB
Driver 4    -11.8 dBm
24 setiembre 2013
00:00
Tx1 6 Kw  <> -0.1 dBm
Tx2 6 Kw  <> +0.5 dBm
Tx3 15 Kw <> +4.0 dB
Driver 4    -11.8 dBm"	vquesada
Milestone 2013_09 Topside Long Pulse	1009	12 Sep 17:30 Datos de Topside Long Pulse disponibles en PUMA	ISR		General		new	2013-09-17T10:28:10-05:00	2013-09-17T10:28:10-05:00	"Para informar que los datos ya se encuentran en el PUMA, en la siguiente dirección:

\\10.10.20.9\puma\Operaciones\DATA_Operaciones\2013_09\LP_FARADAY

"	rabad
Milestone 2013_09 Topside Long Pulse	1007	12 Sep 11:00 Lectura de Potencia	ISR		Transmitters		new	2013-09-12T11:34:18-05:00	2013-09-12T11:34:18-05:00	"08:00
Tx1: 36 Kw
Tx3:  4 Kw
3850 Vac, 295 Kw
09:00
Tx1: 36 Kw
Tx3:  4 Kw
3850 Vac, 295 Kw
10:00
Tx1: 36 Kw
Tx3:  4 Kw
3850 Vac, 295 Kw
11:00
Tx1: 36 Kw
Tx3:  4 Kw
3850 Vac, 295 Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	1006	12 Sep 08:00  Lectura de Potencia	ISR		Transmitters		new	2013-09-12T08:27:42-05:00	2013-09-12T08:27:42-05:00	"20:00
 Tx1:38 Kw
 Tx3:4.5 Kw
 4000 Vac, 300 Kw
21:00
 Tx1:36 Kw
 Tx3: 4 Kw
22:00
 Tx1:35 Kw
 Tx3: 4 Kw
 3950 Vac, 300 Kw
23:00
 Tx1:36 Kw
 Tx3: 4.2 Kw
00:00
 Tx1:36 Kw
 Tx3:4.2 Kw
01:00
 Tx1:38 Kw
 Tx3:4.5 Kw
 4000 Vac, 300 Kw
02:00
 Tx1:36 Kw
 Tx3:4.2 Kw
 3950 Vac, 300 Kw
03:00
 Tx1:36 Kw
 Tx3:4.2Kw
04:00
 Tx1:36 Kw
 Tx3:4 Kw
05:00
 Tx1:35 Kw
 Tx3:4 Kw
05:55
 Se Deshabilita la rf Por cambio de TR recepcion
06:00
 Tx1:35 Kw
 Tx3: 4 Kw
07:00
 Tx1:38 Kw
 Tx3:4.2 Kw
 4000 Vac, 300 Kw
07:35
  Falla PA3 (elevado consuno de corriente de VAC-ION)(1.6uA en el Meter Relay)
07:55
  Se Reinicia transmisión de RF.
"	rtadeo
Milestone 2013_09 Topside Long Pulse	1005	12 Set 07:35 Caida de transmisor	ISR		Transmitters	I. Manay	new	2013-09-12T08:04:57-05:00	2013-09-12T08:04:57-05:00		imanay
Milestone 2013_09 Topside Long Pulse	1004	12 Set 06:10 Atenuacion canal A	ISR		Reception	I. Manay	new	2013-09-12T06:47:43-05:00	2013-09-12T06:47:43-05:00	Debido a que la diferencia de ruido entre los canales A y B se mantenia en 1.9dB, se atenuo el canal A en 1 dB.	imanay
Milestone 2013_09 Topside Long Pulse	1003	12 Set 05:50 Cambio de TRs en sala de Operaciones	ISR		Reception	I. Manay	new	2013-09-12T06:45:00-05:00	2013-09-12T06:45:00-05:00	Se realiza cambio de TRs en sala de Operaciones debido a un incremento en la diferencia de ruido entre los canales A y B (A 1.4 dB mayor que B). Con el cambio la diferencia se incremento a mas de 2dB por lo que se repuso los TRs anteriores pero intercambiandolos. Con este ultimo cambio la diferencia de ruido entre los canales A y B se mantuvo en 1.9 dB (A mayor que B).	imanay
Milestone 2013_09 Topside Long Pulse	1002	12 Sep 01:10 Calibracion de ATRs y TRs	ISR		Spark Gaps	W. Rojas	new	2013-09-12T01:44:41-05:00	2013-09-12T01:44:41-05:00		imanay
Milestone 2013_09 Topside Long Pulse	1001	11 Sep 21:00 Calibracion de ATRs y TRs	ISR		Spark Gaps	W. Rojas	new	2013-09-12T00:28:39-05:00	2013-09-12T00:28:39-05:00		imanay
Milestone 2013_09 Topside Long Pulse	1000	11 Sep 23:58 Graficos de experimento	ISR		Plot	I. Manay	new	2013-09-12T00:19:34-05:00	2013-09-12T00:19:34-05:00		imanay
Milestone 2013_09 Topside Long Pulse	999	11 Sep 19:50 Lectura de Potencias e incidencias del transmisor	ISR		Transmitters		new	2013-09-11T20:15:37-05:00	2013-09-11T20:15:37-05:00	"07:00
Tx1:38 Kw
Tx3: 4 Kw
3950 Vac, 300 Kw

08:00
Tx1:38 Kw
Tx3: 4 Kw
3950 Vac, 300 Kw

09:00
Tx1:37 Kw
Tx3: 4 Kw
3950 Vac, 300 Kw

10:00
Tx1:34 Kw
Tx3: 4 Kw
3820 Vac, 290 Kw

11:00
Tx1:34 Kw
Tx3: 4 Kw
3880 Vac, 290 Kw

12:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw

12:28 CAE FUENTE DE SCREEN PA 1

13:00
Tx1:36 Kw
Tx3: 4 Kw
3900 Vac, 290 Kw

14:00
Tx1:33 Kw
Tx3: 3.5 Kw
3830 Vac, 290 Kw

15:00
Tx1:33 Kw
Tx3: 3.5 Kw
3850 Vac, 290 Kw

16:00
Tx1:33 Kw
Tx3: 3.5 Kw
3840 Vac, 290 Kw

17:00
Tx1:37 Kw
Tx3: 4 Kw
3920 Vac, 300 Kw

18:00
Tx1:36 Kw
Tx3: 4 Kw
3900 Vac, 300 Kw

19:00
Tx1:36 Kw
Tx3: 4 Kw
3920 Vac, 300 Kw
"	ryaya
Milestone 2013_09 Topside Long Pulse	998	11 Sep 8:00 Lectura de Potencia	ISR		Transmitters		new	2013-09-11T08:27:08-05:00	2013-09-11T08:27:08-05:00	"07:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
08:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	997	11 Sep 3:00 Lectura de Potencia	ISR		Transmitters		new	2013-09-11T07:30:21-05:00	2013-09-11T07:30:21-05:00	"04:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
05:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
06:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
"	vquesada
Milestone 2013_09 Topside Long Pulse	996	11 Sep 04:29 CALIBRACION	ISR		Spark Gaps		new	2013-09-11T05:59:19-05:00	2013-09-11T05:59:19-05:00	CALIBRACION DE ATR's y TR's	avaldez
Milestone 2013_09 Topside Long Pulse	995	11 Sep 3.00 Lectura de potencias	ISR		Transmitters		new	2013-09-11T03:26:35-05:00	2013-09-11T03:26:35-05:00	"00:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
01:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
02:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
03:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	994	11 Sep 00:15 CALIBRACION	ISR		Spark Gaps		new	2013-09-11T01:02:44-05:00	2013-09-11T02:11:50-05:00	AJUSTE DE ATR's y TR's	avaldez
Milestone 2013_09 Topside Long Pulse	993	10 Sep 23:59 PROGRAMA DE MONITOREO	ISR		General		new	2013-09-11T00:47:06-05:00	2013-09-11T01:00:45-05:00	"DEBIDO AL CAMBIO DE DIA SE DETUVO EL PROGRAMA DE MONITOREO, SE PROCEDIO A VOLVER A EJECUTAR EL PROGRAMA
EN LA PC_2MONITORES."	avaldez
Milestone 2013_09 Topside Long Pulse	992	10 Sep 20:22  CALIBRACION	ISR		Spark Gaps		new	2013-09-11T00:31:53-05:00	2013-09-11T00:31:53-05:00	CALIBRACION DE CHISPEROS	avaldez
Milestone 2013_09 Topside Long Pulse	991	10 Sep 19:16  REINICIO DE ADQUISICION	ISR		Acquisition system		new	2013-09-11T00:28:45-05:00	2013-09-11T04:20:53-05:00	SE CARGA EL PROGRAMA AL CONTROLADOR DE RADAR, SE HABILITO RF, SE INICIA LA ADQUISICION CORRECTAMENTE.	avaldez
Milestone 2013_09 Topside Long Pulse	990	10 Sep 19:10 FALLA DE TRANSMISORES, PERDIDAD DE SINCRONISMO	ISR		Transmitters		new	2013-09-11T00:27:46-05:00	2013-09-11T00:27:46-05:00	SE DETECTO FALLA DE TRANSMISORES, SE DETUVO LA ADQUISICION, SE QUITO LA RF	avaldez
Milestone 2013_09 Topside Long Pulse	989	10 Sep 18:23 CALIBRACION	ISR		Spark Gaps	AValdez	new	2013-09-11T00:09:11-05:00	2013-09-11T00:24:23-05:00	CALIBRACION DE CHISPEROS ATRs	avaldez
Milestone 2013_09 Topside Long Pulse	988	10 Sep 23:00 Lectura de Potencia	ISR		Transmitters		new	2013-09-10T23:41:07-05:00	2013-09-10T23:41:07-05:00	"21:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
22:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw
23:00
Tx1:38 Kw
Tx3: 4 Kw
4000 Vac, 300 Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	987	10 Sep 20:00 lectura de potencia	ISR		Transmitters		new	2013-09-10T20:15:18-05:00	2013-09-10T20:15:18-05:00	"09:00 
 Tx1 38 Kw
 Tx3 4 Kw
 3910 VAC 300Kw
09:25 
 Falla de Screen PA1
10:00 
 Tx1 32 Kw
 Tx3 3.9 Kw
 3840 VAC 300Kw
11:00 
 Tx1 31 Kw
 Tx3 3.2 Kw
 3790 VAC 290Kw
11:56 
 Falla de la fuente Screen Pa3
12:00 
 Tx1 38 Kw
 Tx3 4.2 Kw
 3950 VAC 300Kw
12:19 
 Se deshabilita La RF
13:50 
 Se habilita la RF
14:00 
 Tx1 33 Kw
 Tx3 3.5 Kw
 3810 VAC 300Kw
15:00 
 Tx1 35 Kw
 Tx3 3.5 Kw
15:05
Se deshabilita la Rf por el cambio del CR. 
16:00 
 Tx1 33 Kw
 Tx3 3.5Kw
 3840 VAC 300Kw
17:00 
 Tx1 33 Kw
 Tx3 3.5 Kw
 3920 VAC 300Kw
18:00 
 Tx1 36 Kw
 Tx3 4 Kw
19:08
 FAlla del circuito crowbar 
 20:00
 Tx1 39 Kw
 Tx3 4.3 Kw
 4000 VAC 300Kw
"	rtadeo
Milestone 2013_09 Topside Long Pulse	986	10 Sep 19:08 Crowbar	ISR		Transmitters		new	2013-09-10T19:46:29-05:00	2013-09-10T19:46:29-05:00	Falla circuito crowbar por elevación de la línea AC	rtadeo
Milestone 2013_09 Topside Long Pulse	985	10 Sep 15:15 INICIA ADQUISICION	ISR		Start experiment	DSuarez	new	2013-09-10T19:07:46-05:00	2013-09-10T19:07:46-05:00	INICIA ADQUISICION CORRECTAMENTE	avaldez
Milestone 2013_09 Topside Long Pulse	984	10 Sep 15:07  CAMBIO DE CR 2C-∅ POR CR 2A-∅	ISR		Acquisition system	DSuarez	new	2013-09-10T18:52:55-05:00	2013-09-11T00:13:02-05:00	CAMBIO DE CR 2C-∅ POR CR 2A-∅, DEBIDO A PROBLEMAS DE SINCRONISMO 	avaldez
Milestone 2013_09 Topside Long Pulse	983	10 Sep 14:50  PERDIDA DE SINCRONISMO	ISR		Start experiment	DSuarez	new	2013-09-10T18:45:41-05:00	2013-09-10T18:45:41-05:00	SE VUELVE A DETECTAR LA PERDIDDA DE SINCRONISMO	avaldez
Milestone 2013_09 Topside Long Pulse	982	10 Sep 14:45  PERDIDA DE SINCRONISMO	ISR		Acquisition system	DSuarez	new	2013-09-10T18:40:50-05:00	2013-09-11T00:17:15-05:00	SE OBSERVA LA PERDIDAD DE SINCRONISMO	avaldez
Milestone 2013_09 Topside Long Pulse	981	10 Sep 14:26  CAMBIO TR	ISR		Start experiment	DSuarez	new	2013-09-10T18:36:45-05:00	2013-09-10T18:36:45-05:00	CAMBIO TR CANAL A	avaldez
Milestone 2013_09 Topside Long Pulse	980	10 Sep 14:22  CALIBRACION ATRs	ISR		Antennas	DSuarez	new	2013-09-10T18:34:28-05:00	2013-09-11T00:16:05-05:00	CALIBRACION ATRs-TA	avaldez
Milestone 2013_09 Topside Long Pulse	979	10 Sep 13:46  REINICIO	ISR		Acquisition system	DSuarez	new	2013-09-10T18:31:04-05:00	2013-09-11T00:22:32-05:00	SE REINICIA DE NUEVO LA ADQUISICION.	avaldez
Milestone 2013_09 Topside Long Pulse	978	10 Sep 13:45  SEÑAL PROVENIENTE  DEL SISTEMA ABS_CONTROL	ISR		Start experiment	DSuarez	new	2013-09-10T18:29:24-05:00	2013-09-10T18:29:24-05:00	EL SISTEMA ABS CONTROL ESTABA GENERANDO UNA SEÑAL A 100 Hz	avaldez
Milestone 2013_09 Topside Long Pulse	977	10 Sep 12:57 Cambio de CR 2A-0 por CR 2C-0	ISR		Acquisition system		new	2013-09-10T18:10:59-05:00	2013-09-10T18:10:59-05:00	"Se prueba si es el controlador de radar el que genera la señal ""intrusa"""	dsuarez
Milestone 2013_09 Topside Long Pulse	976	10 Sep 12:19 Se detiene el TX	ISR		General		new	2013-09-10T18:08:18-05:00	2013-09-10T18:08:18-05:00	"Se adquieren datos sin transmisor para observar la persistencia de la señal ""instrusa"" en el sistema."	dsuarez
Milestone 2013_09 Topside Long Pulse	975	10 Sep 12:18 Se quita el spliter en la entrada del canal A	ISR		Acquisition system		new	2013-09-10T18:06:35-05:00	2013-09-10T18:06:35-05:00	La señal del spliter se dirigio hacia la PC_RADAR, donde tambien se observó la señal de 10ms, por tanto el problema no era el sistema de adquisición en la PC_ARES	dsuarez
Milestone 2013_09 Topside Long Pulse	974	10 Sep 7 11:33 Se detiene Adquisición, Spliter en la entrada del canal A	ISR		Acquisition system		new	2013-09-10T18:04:06-05:00	2013-09-10T18:04:06-05:00	Se busca identificar el origen de una señal con periodo de 10ms	dsuarez
Milestone 2013_09 Topside Long Pulse	973	10 Sep 11:25 Se reinicia el procesamiento	ISR		Process/Analysis Program		new	2013-09-10T18:02:08-05:00	2013-09-10T18:02:08-05:00		dsuarez
Milestone 2013_09 Topside Long Pulse	972	10 Sep 11:00 Se reinicia la pc de procesamiento 10.10.20.14	ISR		Process/Analysis Program		new	2013-09-10T18:01:07-05:00	2013-09-10T18:01:07-05:00	Esta pc estaba corriendo scanssh desde un usuario test, se eliminó el usuario y todos los procesos relacionados a este, se tuvo que reiniciar la PC	dsuarez
Milestone 2013_09 Topside Long Pulse	971	10 Sep 9:36 Calibración de ATRs-TRs	ISR		Antennas		new	2013-09-10T17:58:00-05:00	2013-09-10T17:58:00-05:00		dsuarez
Milestone 2013_09 Topside Long Pulse	970	10 Sep 7:32 Se levanta el Tx	ISR		Transmitters		new	2013-09-10T17:57:19-05:00	2013-09-10T17:57:19-05:00		dsuarez
Milestone 2013_09 Topside Long Pulse	969	10 Sep 7:30 Cae Tx	ISR		Transmitters		new	2013-09-10T17:56:30-05:00	2013-09-10T17:56:30-05:00		dsuarez
Milestone 2013_09 Topside Long Pulse	968	10 Sep 13:50  Se habilita la RF	ISR		Transmitters		new	2013-09-10T14:42:17-05:00	2013-09-10T14:42:17-05:00	"se habilita la rf. 
Se elimino la interferencia bajando la llave que alimenta la antena principal; Posiblemente los módulos de control Abs.
Para futuras pruebas considerar en el descarte de posibles fallas.  "	rtadeo
Milestone 2013_09 Topside Long Pulse	967	10 Sep 12:19  RF	ISR		Transmitters		new	2013-09-10T12:44:01-05:00	2013-09-10T12:44:01-05:00	Se deshabilita la RF para Pruebas	rtadeo
Milestone 2013_09 Topside Long Pulse	966	10 Sep 11:56  Falla screen	ISR		Transmitters		new	2013-09-10T12:19:33-05:00	2013-09-10T12:19:33-05:00	Falla de la fuente de Screen PA3(Des habilitación del circuito de control)	rtadeo
Milestone 2013_09 Topside Long Pulse	965	10 Sep 09:25  Falla screen	ISR		Transmitters		new	2013-09-10T09:57:29-05:00	2013-09-10T09:57:29-05:00	"
Falla de la fuente de Screen  del PA 1(des habilitación por el circuito de control)"	rtadeo
Milestone 2013_09 Topside Long Pulse	964	10 Sep 08:00 Mensaje de error mostrado en el logbook	ISR		General	DCordova	new	2013-09-10T08:21:04-05:00	2013-09-10T08:21:04-05:00	"Se ha venido observando el siguiente mensaje cada vez que se sube un ticket, durante el turno
Warning: The ticket has been created, but an error occurred while sending notifications: [Errno 110] Connection timed out "	dcordova
Milestone 2013_09 Topside Long Pulse	963	10 Sep 00:00 Se detiene programa de procesamiento por el cambio de hora	ISR		Process/Analysis Program	DCordova	new	2013-09-10T08:16:23-05:00	2013-09-10T08:47:14-05:00	Se detiene el programa de procesamiento, se vuelve a reiniciar y generar graficos de ruido, Faraday, RTI, y densidades	dcordova
Milestone 2013_09 Topside Long Pulse	962	10 Sep 07:30 Revision de TR	ISR		Reception	DCordova	new	2013-09-10T07:53:50-05:00	2013-09-10T07:53:50-05:00	Se revisa TR A, el cual fue cambiado, se observa que se ha quemado condensador de sintonia de alto voltaje	dcordova
Milestone 2013_09 Topside Long Pulse	961	10 Sep 06:45 Cambio de TR de recepcion en el canal A	ISR		Reception	DCordova	new	2013-09-10T07:26:36-05:00	2013-09-10T07:26:36-05:00	"Se observa que el nivel de ruido del canal se habia incrementado en 3dB (5:20 am), se cambia de TR y observa que el ruido del canal A disminuye y se compara al canal B.
Noise A: 54.01 dB
Noise B: 55.07 dB"	dcordova
Milestone 2013_09 Topside Long Pulse	960	10 de Setyiembre 07:00 Lectura de Potencia	ISR		Transmitters		new	2013-09-10T07:25:09-05:00	2013-09-10T07:25:09-05:00	"06:00 
Tx1 38 Kw
Tx3 4 Kw
3950 VAC 300Kw
07:00 
Tx1 38 Kw
Tx3 4 Kw
3950 VAC 300Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	959	10 Sep 05:34 Calibracion de chisperos	ISR		Spark Gaps	ACoronado	new	2013-09-10T07:17:14-05:00	2013-09-10T07:17:14-05:00	Calibracion de ATR y TR	dcordova
Milestone 2013_09 Topside Long Pulse	958	10 Sep 01:42 Calibracion de chisperos	ISR		Spark Gaps	ACoronado	new	2013-09-10T07:16:04-05:00	2013-09-10T07:16:04-05:00	Calibracion de ATR y TR	dcordova
Milestone 2013_09 Topside Long Pulse	957	09 Sep 21:37 Calibracion de chisperos	ISR	JRO Staff	Spark Gaps	ACoronado	new	2013-09-10T07:13:51-05:00	2013-09-10T07:13:51-05:00	Calibracion de ATR y TR	dcordova
Milestone 2013_09 Topside Long Pulse	956	Lectura de Potencia	ISR		Transmitters		new	2013-09-10T05:25:03-05:00	2013-09-10T05:25:03-05:00	"10 Set 2013
03:00 
Tx1 38 Kw
Tx3 4 Kw
3950VAC 300Kw
03:44 y 03:56  cae fuente de screen PA Tx1
04:00 
Tx1 38 Kw
Tx3 4 Kw
3950 VAC 300Kw
05:00 
Tx1 38 Kw
Tx3 4 Kw
3950 VAC 300Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	955	Lectura de Potencia	ISR		Transmitters		new	2013-09-10T02:26:26-05:00	2013-09-10T02:26:26-05:00	"10 Set 2013
00:00 
Tx1 40 Kw
Tx3 4.5 Kw
4000VAC 300Kw
01:00 
Tx1 40 Kw
Tx3 4.5 Kw
4000 VAC 300Kw
01:10 y 01:30 cae fuente de screen PA Tx1
02:00 
Tx1 38 Kw
Tx3  4 Kw
3950 VAC 300Kw
"	vquesada
Milestone 2013_09 Topside Long Pulse	954	09 Sep 00:00 Figuras de rtis, espectros, potencias, ruidos y resultados	ISR		Start experiment	DCordova	new	2013-09-10T00:19:41-05:00	2013-09-10T00:19:41-05:00		dcordova
Milestone 2013_09 Topside Long Pulse	952	Lectura de potencias	ISR		Transmitters		new	2013-09-09T21:33:07-05:00	2013-09-09T21:33:07-05:00	"09 Set2013
20:00 
Tx1 40 Kw
Tx3 4.5 Kw
4000VAC 300Kw
21:00 
Tx1 40 Kw
Tx3 4.5 Kw
4000VAC 300Kw"	vquesada
Milestone 2013_09 Topside Long Pulse	951	09 Set 18:06 Inicio de experimento Topside Long Pulse	ISR		Start experiment		new	2013-09-09T19:13:28-05:00	2013-09-09T19:13:28-05:00	"-Se programa el Divisor de Frecuencia debido a desincronizaci'on, se ven pulsos de 1000km de Ipp.
"	rabad
Milestone 2013_09 Topside Long Pulse	950	09 Set 18:06 Inicio de experimento Topside Long Pulse	ISR		Start experiment		new	2013-09-09T19:13:26-05:00	2013-09-09T19:13:26-05:00	"-Se programa el Divisor de Frecuencia debido a desincronizaci'on, se ven pulsos de 1000km de Ipp.
"	rabad
Milestone 2013_09 Topside Long Pulse	949	09 Set 12:25 Log Created	ISR		Start experiment		new	2013-09-09T12:45:15-05:00	2013-09-09T12:45:15-05:00	The log for the Topside Long Pulse is active 	ryanque
Milestone 2013_09 Topside Long Pulse	948	09 Set 12:24 Antenna Impedance	ISR		Antennas		new	2013-09-09T12:42:40-05:00	2013-09-09T12:43:36-05:00	"VSWR

WUP 1.02
WDN 1.01
NUP 1.08 - 49.98 MHz 1.06
NDN 1.07 - 49.98 MHz 1.01
EUP 1.01
EDN 1.06 - 49.98 MHz 1.01
SDN 1.08 - 49.98 MHz 1.00
SUP 1.02"	ryanque
Milestone 2013_07_1 EW_Drift+Faraday	932	30 Jul 23:55 Lectura de Potencias	ISR	JRO Staff	Transmitters		new	2013-07-31T01:17:39-05:00	2013-08-06T09:56:43-05:00	"30 de Julio del 2013
20:00
Tx1 15 Kw, +5.5 dBm
Tx2 19 Kw, +6.2 dBm
Tx4 9 Kw, + 5 dbm
V:4000Vac,360 Kw
20:28 Caida de fuente screen PA2
21:00
Tx1 15 Kw
Tx2 19 Kw
Tx4 9 Kw
V:4000Vac,360 Kw
22:00
Tx1 15 Kw
Tx2 19 Kw
Tx4 9 Kw
V:4000Vac,360 Kw
23:00
Tx1 14 Kw
Tx2 18 Kw
Tx4 9 Kw
V: 3950 Vac,350 Kw
31 de Julio del 2013
00:00
Tx1 14 Kw
Tx2 18 Kw
Tx4 9 Kw
V: 3950 Vac,350 Kw
00:45 Caida de fuente screen PA2
01:00
Tx1 14 Kw
Tx2 18 Kw
Tx4 9 Kw
V: 3950 Vac,350 Kw"	vquesada
Milestone 2013_07_1 EW_Drift+Faraday	931	30 Jul 18:80 Se cambia TR de Canal D para ver si cambia	ISR		Reception	P Condor	new	2013-07-30T19:51:56-05:00	2013-07-30T19:51:56-05:00	Se cambia TR de Canal D para ver si cambia	pcondor
Milestone 2013_07_1 EW_Drift+Faraday	930	30 Jul 18:07  Se Desconecta cables de Faraday para acomodarlos	ISR		Acquisition system	P Condor	new	2013-07-30T19:50:48-05:00	2013-07-30T19:50:48-05:00	Desconecta cables de Faraday para acomodarlos	pcondor
Milestone 2013_07_1 EW_Drift+Faraday	929	30 Jul 17:30 Inicio de experimento EW_Drifts+Faraday	ISR		Start experiment	P Condor	new	2013-07-30T19:49:16-05:00	2013-07-30T19:49:16-05:00	 Inicio de experimento EW_Drifts+Faraday	pcondor
Milestone 2013_07_1 EW_Drift+Faraday	928	30 Jul 12:04 Antenna Impedance	ISR		Antennas		new	2013-07-30T12:10:22-05:00	2013-07-30T12:11:19-05:00	"SUP 1.08
SDN 1.03 (Centered 49.94)
EDN 1.09 (Centered 50.03)
EUP 1.02
NUP 1.10 (Centered 50.00)
NDN 1.05 (Centered 49.98)
WDN 1.04 (Centered 49.95)
WUP 1.01"	ryanque
Milestone 2013_07_1 EW_Drift+Faraday	927	30 Jul 08:40 Log for Experiment Jul 30 EW Drift+Faraday	ISR		Start experiment		new	2013-07-30T08:46:54-05:00	2013-07-30T08:46:54-05:00	"The log for the ISR School has been activated
EW-Drift + Faraday"	ryanque
Milestone 2013_07 EW_Drift + Faraday	1084	08 Oct 01:00 Datos en Madrigal	ISR		Process/Analysis Program		new	2013-10-08T00:26:19-05:00	2013-10-08T00:26:19-05:00	Los datos procesados estan en Madrigal.	pcondor
Milestone 2013_07 EW_Drift + Faraday	1012	24 de Setiembre 2013 Lectura de Potencia	ISR		Transmitters		new	2013-09-24T03:30:22-05:00	2013-09-24T03:30:22-05:00	"01:00
Tx1 6 Kw <> -0.1 dBm
Tx2 6 Kw <> +4.2 dBm
Tx3 15 Kw<>+4.0 dB
Driver 4  -11.7 dBm
01:45 y 01:50 crowbar por caida de tension
02:00
Tx1 9 Kw <> -1.4 dBm
Tx2 9 Kw <> +4.5 dBm
Tx3 15 Kw <> +4.2 dB
Driver 4 -11.5 dBm
03:00
Tx1 9 Kw <> +1.4 dBm
Tx2 9 Kw <> +4.5 dBm
Tx3 15 Kw <> +4.2 dB
Driver 4 -11.5 dBm"	vquesada
Milestone 2013_07 EW_Drift + Faraday	926	12 Jul 15:05 Resumen de lectura de potencias TX	ISR		Transmitters		new	2013-07-12T15:24:07-05:00	2013-07-12T15:24:07-05:00	"Viernes 12 de Julio 2013
08:00
Tx1 9 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de linea:3950 VAC 320 Kw
09:00
Tx1 9 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3830 VAC 310 Kw
10:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3820 VAC 300 Kw
11:00
Tx1 7 Kw
Tx2 10 Kw
Tx3 18 Kw
Voltaje de linea:3800 VAC 300 Kw
12:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de linea:3900 VAC 320 Kw
13:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de linea:3900 VAC 320 Kw
14:00
Tx1 8 Kw
Tx2 10 Kw
Tx3 18 Kw
Voltaje de linea:3800 VAC 300 Kw
15:00
Tx1 8 Kw
Tx2 10 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 300 Kw
15:05 TXs OFF"	ryaya
Milestone 2013_07 EW_Drift + Faraday	925	RTI 12 de julio	ISR		Plot		new	2013-07-12T15:19:20-05:00	2013-08-17T21:27:59-05:00	RTI final del experimento	vquesada
Milestone 2013_07 EW_Drift + Faraday	923	12 Jul 07:35 Niveles de ruido	ISR		Reception	D. Cordova	new	2013-07-12T07:49:37-05:00	2013-07-12T07:49:37-05:00	"EWDrift
A:24.43 dB
B:24.24 dB
C:24.03 dB
D:24.05 dB
Faraday
A:39.59 dB
B:39.36 dB"	dcordova
Milestone 2013_07 EW_Drift + Faraday	919	12 Jul 07:00 Lectura de Potencia	ISR	JRO Staff	Transmitters		new	2013-07-12T07:15:59-05:00	2013-08-06T10:01:02-05:00	"Viernes 12 de Julio 2013
02:00
Tx1 9 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea:3900 VAC 320 Kw
03:00
Tx1 9 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea:3900 VAC 320 Kw
04:00
Tx1 9 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea:3900 VAC 320 Kw
05:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 310 Kw
06:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 310 Kw
07:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 310 Kw"	vquesada
Milestone 2013_07 EW_Drift + Faraday	917	12 Jul 06:15 Ajuste de chisperos ATRs y TRs	ISR		Spark Gaps	A.Belleza	new	2013-07-12T06:42:54-05:00	2013-07-12T06:42:54-05:00		dcordova
Milestone 2013_07 EW_Drift + Faraday	916	12 Jul 05:30 Se observa que programa Faraday no actualiza graficas	ISR		Process/Analysis Program	D. Cordova	new	2013-07-12T06:30:18-05:00	2013-07-12T06:30:18-05:00	"05:30 Se observa que programa Faraday no actualiza graficas
Se observa que la pc de adquisicion esta trabajando
Se entra a linea de comandos y se ve con ""df"" que el disco para Faraday no esta montado
Se sigue el procedimiento del manual pero no funciona, y esto se debio a que no se ve la pc de Farday adquisicion
Se reviso la pc de adquisicion y se encontro que el cable de red esta haciendo un falso contacto, se ajusto un poco y volvio a conectarse
6:00 Se volvio a correr el programa de procesamiento y genero los graficos que debia generarse"	dcordova
Milestone 2013_07 EW_Drift + Faraday	915	11 Jul 23:16 Ajuste de chisperos ATRs y TRs	ISR		Start experiment	A.Belleza	new	2013-07-12T02:25:44-05:00	2013-07-12T02:25:44-05:00		dcordova
Milestone 2013_07 EW_Drift + Faraday	914	11 Jul 19:50 Ajuste de chisperos ATRs y TRs	ISR		Spark Gaps	A.Belleza	new	2013-07-12T02:24:38-05:00	2013-07-12T02:24:38-05:00		dcordova
Milestone 2013_07 EW_Drift + Faraday	913	12 Jul 02:08 Ruido observados en la adquisicion	ISR		Reception	D. Cordova	new	2013-07-12T02:21:39-05:00	2013-07-12T02:21:39-05:00	"EWDrift
A:26.05 dB 
B:26.51 dB 
C:26.48 dB
D:26.10 dB
Faraday
A:41.72 dB
B:41.46 dB"	dcordova
Milestone 2013_07 EW_Drift + Faraday	912	12 Jul 01:00 Se observa que programa SignalChain no actualiza graficas	ISR		Process/Analysis Program	D. Cordova	new	2013-07-12T02:17:11-05:00	2013-07-12T02:17:11-05:00	" 01:00 Se observa que programa SignalChain no actualiza graficas
 01:02 Se reinicia programa SignalChain, se observa que actualizan las graficas"	dcordova
Milestone 2013_07 EW_Drift + Faraday	911	12 Jul 01:00 Lectura de Potencia	ISR		Transmitters	V. Quesada	assigned	2013-07-12T01:30:41-05:00	2013-08-06T10:01:45-05:00	"Jueves 11 de Julio 2013
20:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de linea:4020 VAC 330 Kw
21:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de linea:4020 VAC 330 Kw
22:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de linea:4020 VAC 330 Kw
23:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de linea:4020 VAC 330 Kw
12 de Julio 2013
00:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de linea:4020 VAC 330 Kw
01:00
Tx1 9 Kw
Tx2 12 Kw
Tx3 22 Kw
Voltaje de linea:3900 VAC 320 Kw"	vquesada
Milestone 2013_07 EW_Drift + Faraday	910	12 Jul 00:19 Desincroniza PC de EWDRIFTS	ISR		Break Experiment	D. Cordova	new	2013-07-12T01:06:10-05:00	2013-07-12T01:15:05-05:00	"00:19 Se desincroniza PC de EWDrifts, se detiene ese experimento
00:24  Se  reinicia experimento
00:30 Se desincroniza de nuevo PC de EWDrifts, se detienen Faraday y EWdrifts
00:33 Se reinician experimentos
00:40 Se observa que procesamiento de Faraday no funciona
00:45 Se reinicia Faraday"	dcordova
Milestone 2013_07 EW_Drift + Faraday	909	12 Jul 00:00 Graficas de rtis, resultados y espectros	ISR		Process/Analysis Program	D. Cordova	new	2013-07-12T00:12:31-05:00	2013-07-12T00:12:31-05:00		dcordova
Milestone 2013_07 EW_Drift + Faraday	908	11 Jul 11:45 Graficas de rtis, resultados y espectros	ISR		Process/Analysis Program	D. Cordova	new	2013-07-11T23:54:56-05:00	2013-07-11T23:54:56-05:00		dcordova
Milestone 2013_07 EW_Drift + Faraday	907	11 Jul 9:10 Ruido observados en la adquisicion	ISR		Acquisition system	D. Cordova	new	2013-07-11T21:27:49-05:00	2013-07-11T21:27:49-05:00	"EWDrift
A:26.97 dB      CoherAB: 0.06
B:27.76 dB      CoherCD: 0.125
C:27.17 dB
D:27.08 dB
Faraday
A:42.44 dB
B:42.08 dB
"	dcordova
Milestone 2013_07 EW_Drift + Faraday	906	11 Jul 19:50 Ajuste de chisperos y mejora en la diferencia de ruido de A y B EW-Drift	ISR		Reception	D. Cordova	new	2013-07-11T21:17:31-05:00	2013-07-11T21:17:31-05:00	Se ajusto los chisperos y la diferencua de ruido entre A y B es 0.6dB	dcordova
Milestone 2013_07 EW_Drift + Faraday	905	11 Jul 19:44 diferencia de ruido entre canal A y B mayor a 1dB	ISR		Reception	D. Cordova	new	2013-07-11T21:13:59-05:00	2013-07-11T21:18:14-05:00	"Se observa que el ruido entre los canales A y B son:
A:24.96dB
B:26.87dB"	dcordova
Milestone 2013_07 EW_Drift + Faraday	904	11 Jul 14:00 Lectura de Potencia	ISR		Transmitters	rtadeo	new	2013-07-11T20:03:52-05:00	2013-07-11T20:03:52-05:00	"11/07/2013
 hora      Tx      Fill        Pot(inc)
15:00      1       16.5        8Kw     
           2       16.5       11Kw     
           3       16.5       18Kw
16:00      1       16.5        8Kw     
           2       16.5       11Kw     
           3       16.5       18Kw
17:00      1       16.5        8Kw     
           2       16.5       11Kw     
           3       16.5       19Kw
18:00      1       16.5        8Kw     
           2       16.5       11Kw     
           3       16.5       19Kw
19:00      1       16.5        8Kw    4050VAC  3f    
           2       16.5       11Kw     310Kw
           3       16.5       22Kw



 

"	rtadeo
Milestone 2013_07 EW_Drift + Faraday	903	11 Jul 19:44 Se calibra chisperos de A y B	ISR		Antennas	P. Condor	new	2013-07-11T20:03:19-05:00	2013-07-11T20:03:19-05:00	 Se calibra chisperos de A y B por diferencia de ruido es mayor de 2 db	pcondor
Milestone 2013_07 EW_Drift + Faraday	902	11 Jul 19:03 Caida de transmisor	ISR		Transmitters	P. Condor	new	2013-07-11T19:15:34-05:00	2013-07-11T19:15:34-05:00	Caida de transmisor por falla de la linea.	pcondor
Milestone 2013_07 EW_Drift + Faraday	901	11 Jul 18:54 Figuras del turno de dia	ISR		Process/Analysis Program	P. Condor	new	2013-07-11T19:05:27-05:00	2013-07-11T19:05:27-05:00	Se pone los rtis, resultados y espectros del turno de dia.	pcondor
Milestone 2013_07 EW_Drift + Faraday	900	11 Jul 17:35 Ajuste de chisperos ch A y B Rx	ISR		Antennas	W. Rojas	new	2013-07-11T19:03:27-05:00	2013-07-11T19:03:27-05:00	Ajuste de chisperos ch A y B Rx. Diferencia de ruido  A y B se elevo mas de 1 db. Se corregio a menos de 1 db haciendo esto de revision de chisperos.	pcondor
Milestone 2013_07 EW_Drift + Faraday	899	11 Jul 15:44 Ajuste de chisperos ATRs y TRs	ISR		Antennas	W. Rojas	new	2013-07-11T19:01:09-05:00	2013-07-11T19:01:09-05:00	Ajuste de chisperos ATRs y TRs	pcondor
Milestone 2013_07 EW_Drift + Faraday	898	11 Jul 12:25 Ajuste de chisperos ATRs y TRs	ISR		Antennas	W. Rojas	new	2013-07-11T19:00:29-05:00	2013-07-11T19:00:29-05:00	Ajuste de chisperos ATRs y TRs	pcondor
Milestone 2013_07 EW_Drift + Faraday	897	11 Jul 14:00 Lectura de Potencia	ISR		Transmitters	rtadeo	new	2013-07-11T15:16:57-05:00	2013-07-11T19:58:46-05:00	"11/07/2013
hora      Tx    Fill     Pot(inc)
08:00      1     16.5      8Kw     3900  3F
           2     16.5     12Kw       310KW
           3     16.5     20Kw
09:00      1     16.5      8Kw     
           2     16.5     11Kw
           3     16.5     19Kw
10:00      1     16.5      7Kw     
           2     16.5     11Kw
           3     16.5     18Kw
11:00      1     16.5      7Kw     
           2     16.5     11Kw
           3     16.5     18Kw
12:00      1     16.5      8Kw  3950VAC  3F     
           2     16.5     12Kw    310KW
           3     16.5     20Kw
13:00      1     16.5      7Kw     
           2     16.5     11Kw
           3     16.5     17Kw
14:00      1     16.5      8Kw     
           2     16.5     12Kw
           3     16.5     20Kw






"	rtadeo
Milestone 2013_07 EW_Drift + Faraday	886	11 Jul 07:00 Lectura de Potencia	ISR	JRO Staff	Transmitters		new	2013-07-11T07:50:01-05:00	2013-08-06T10:04:30-05:00	"Miercoles 10 de Julio 2013
20:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 23 Kw
Voltaje de linea:4050 VAC 330 Kw
21:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 23 Kw
Voltaje de linea:4050 VAC 330 Kw
22:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 23 Kw
Voltaje de linea:4050 VAC 330 Kw
23:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 23 Kw
Voltaje de linea:4050 VAC 330 Kw
Jueves 11 de Julio 2013
00:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 23 Kw
Voltaje de linea:3900 VAC 320 Kw
01:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 310 Kw
02:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 310 Kw
03:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de linea:3850 VAC 310 Kw
04:00
Tx1 9Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea:3900 VAC 310 Kw
05:00
Tx1 9Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea:3900 VAC 310 Kw
06:00
Tx1 9Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea: 3900 VAC 310 Kw
07:00
Tx1 9Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de linea:3900 VAC 310 Kw"	vquesada
Milestone 2013_07 EW_Drift + Faraday	885	11 Jul 05:58 Ajuste de chisperos ATR-s y TR-s	ISR		Spark Gaps	J.Lavado	new	2013-07-11T06:10:28-05:00	2013-07-11T06:10:28-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	884	11 Jul 01:52 Ajuste de chisperos ATR-s y TR-s	ISR		Spark Gaps	J.Lavado	new	2013-07-11T02:08:24-05:00	2013-07-11T02:08:24-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	883	10 Jul 21:44 Ajuste de ATR-s y TR-s	ISR		Spark Gaps	J.Lavado	new	2013-07-11T00:38:02-05:00	2013-07-11T00:38:02-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	882	10 Jul 23:59 Plots de EW_Drifts	ISR		Plot	I. Manay	new	2013-07-11T00:19:16-05:00	2013-07-11T00:19:16-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	881	10 Jul 23:55 Plots de Faraday	ISR		Plot	I. Manay	new	2013-07-11T00:13:05-05:00	2013-07-11T00:13:05-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	880	10 Jul 19:50 Resumen de lectura de potencias TX	ISR		Transmitters		new	2013-07-10T19:56:21-05:00	2013-07-10T19:57:52-05:00	"Miercoles 10 de Julio
15:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 20 Kw
Voltaje de Línea 3920 VAC, 320 Kw.
16:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de Línea 3980 VAC, 330 Kw.
17:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de Línea 3980 VAC, 330 Kw
18:00
Tx1 9 Kw
Tx2 12 Kw
Tx3 22 Kw
Voltaje de Línea 3980 VAC, 330 Kw.
19:00
Tx1 9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de Línea 4000 VAC, 330 Kw.
"	ryaya
Milestone 2013_07 EW_Drift + Faraday	879	10 Jul 14:00 Resumen de lectura de potencias TX	ISR		Transmitters		new	2013-07-10T14:25:57-05:00	2013-07-10T14:25:57-05:00	"Miercoles 10 de Julio
08:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de Linea 3920 VAC, 320 Kw.
09:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de Linea 3900 VAC, 320 Kw.
10:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 19 Kw
Voltaje de Linea 3850 VAC, 320 Kw
11:00
Tx1 8 Kw
Tx2 11 Kw
Tx3 19 Kw
Voltaje de Linea 3900 VAC, 320 Kw.
12:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de Linea 3980 VAC, 320 Kw.
13:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 21 Kw
Voltaje de Linea 3980 VAC, 330 Kw
14:00
Tx1 7 Kw
Tx2 10 Kw
Tx3 18 Kw
Voltaje de Linea 3800 VAC, 300 Kw"	ryaya
Milestone 2013_07 EW_Drift + Faraday	878	10 Jul 08:44 Falla fuente SCREEN PA 1	ISR		Transmitters		new	2013-07-10T08:57:33-05:00	2013-07-10T08:57:33-05:00	Falla fuente SCREEN PA 1, falsa alarma de circuito de interlock.	ryaya
Milestone 2013_07 EW_Drift + Faraday	877	10 Jul 00:00 Graficas de rtis, resultados y espectros	ISR		Process/Analysis Program	P. Condor	new	2013-07-10T07:29:52-05:00	2013-07-10T07:29:52-05:00	Graficas de rtis, spectros y resultados de drifts y faraday	pcondor
Milestone 2013_07 EW_Drift + Faraday	876	10 Jul 06:02 Falla por accion de crowbar	ISR	JRO Staff	Transmitters	rtadeo	new	2013-07-10T07:20:53-05:00	2013-07-10T07:20:53-05:00	Variacion en la linea AC	rtadeo
Milestone 2013_07 EW_Drift + Faraday	875	10 Jul 05:59 Caida de transmisor	ISR		Transmitters	P. Condor	new	2013-07-10T07:16:26-05:00	2013-07-10T07:16:26-05:00	Caida de transmisor. Problema del alto voltaje	pcondor
Milestone 2013_07 EW_Drift + Faraday	873	10 Jul 02:58 Ajuste de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-07-10T07:08:44-05:00	2013-07-10T07:08:44-05:00	Ajuste de ATRs y TRs	pcondor
Milestone 2013_07 EW_Drift + Faraday	872	10 Jul 04:15  Falla screen	ISR	Others	Transmitters	rtadeo	new	2013-07-10T07:03:52-05:00	2013-07-10T07:03:52-05:00	PA .1	rtadeo
Milestone 2013_07 EW_Drift + Faraday	870	09 Jul 23:00  Falla por caida de crowbar	ISR	Others	Transmitters	rtadeo	new	2013-07-10T06:54:25-05:00	2013-08-20T18:01:09-05:00	"Variacion en la linea AC
Se repone a las 23:02"	rtadeo
Milestone 2013_07 EW_Drift + Faraday	869	09 Jul 22:08 Ajuste de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-07-10T06:53:30-05:00	2013-07-10T06:53:30-05:00	Ajuste de ATRs y TRs	pcondor
Milestone 2013_07 EW_Drift + Faraday	868	09 Jul 19:00 Lectura de Potencia	ISR	JRO Staff	Transmitters		new	2013-07-09T19:35:43-05:00	2013-08-06T10:03:49-05:00	"Martes 9 de Julio
15:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de Linea 3890 VAC, 320 Kw.
16:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de Linea 3890 VAC, 320 Kw.
17:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 19 Kw
Voltaje de Linea 3980 VAC, 320 Kw
18:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de Linea 3980 VAC, 320 Kw.
19:00
Tx1 0 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de Linea 3980 VAC, 330 Kw.
19:20 Crowbar por caida de tension"	vquesada
Milestone 2013_07 EW_Drift + Faraday	867	09 Jul 18:10 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	J.Lavado	new	2013-07-09T19:22:57-05:00	2013-07-09T19:22:57-05:00	Ajuste de chisperos ATR's y TR's.	rabad
Milestone 2013_07 EW_Drift + Faraday	866	09 Jul 14:26 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	J.Lavado	new	2013-07-09T16:08:58-05:00	2013-07-09T16:08:58-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	865	09 Jul 09:40 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	J.Lavado	new	2013-07-09T16:08:10-05:00	2013-07-09T16:09:41-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	864	09 Jul 09:34 Cae transmisores	ISR		Transmitters		new	2013-07-09T16:07:34-05:00	2013-08-20T17:53:35-05:00	"09:34 Cae transmisores por tensión
09:35 Se habilita transmisor"	rabad
Milestone 2013_07 EW_Drift + Faraday	861	09 Jul 06:01 Problemas transmisores	ISR		Transmitters		new	2013-07-09T16:02:17-05:00	2013-08-20T18:02:05-05:00	"- Cae tensi'on
Se levanta el TX a las 6:02"	rabad
Milestone 2013_07 EW_Drift + Faraday	860	09 Jul 05:53 Se habilita transmisores	ISR		Transmitters		new	2013-07-09T15:59:03-05:00	2013-07-09T15:59:03-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	859	09 Jul 05:50 Ca'ida de tensi'on (Transmisores)	ISR		Transmitters		new	2013-07-09T14:49:11-05:00	2013-07-09T14:49:11-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	858	09 Jul 05:45 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	A. Coronado	new	2013-07-09T14:47:54-05:00	2013-07-09T14:47:54-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	857	09 Jul 01:18 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	A. Coronado	new	2013-07-09T14:46:51-05:00	2013-07-09T14:46:51-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	856	08 Jul 21:36 Se reinicia experimento EW_Drift	ISR		Acquisition system		new	2013-07-09T14:32:31-05:00	2013-07-09T14:32:31-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	855	09 Jul 14:00 Lectura de Potencia	ISR	JRO Staff	Transmitters		new	2013-07-09T14:12:00-05:00	2013-08-06T10:02:50-05:00	"Martes 9 de Julio
08:00
Tx1  8 Kw
Tx2 12 Kw
Tx3 18 Kw
Voltaje de Linea 3950 VAC, 320 Kw.
09:00
Tx1  8 Kw
Tx2 12 Kw
Tx3 18 Kw
Voltaje de Linea 3950 VAC, 320 Kw.
09:37 Crowbar por caida de tension
10:00
Tx1  8 Kw
Tx2 12 Kw
Tx3 19 Kw
Voltaje de Linea 3850 VAC, 320 Kw
11:00
Tx1 8 Kw
Tx2 12 Kw
Tx3 19 Kw
Voltaje de Linea 3980 VAC, 320 Kw.
12:00
Tx1  9 Kw
Tx2 13 Kw
Tx3 23 Kw
Voltaje de Linea 4040 VAC, 330 Kw.
13:00
Tx1  9 Kw
Tx2 13 Kw
Tx3 22 Kw
Voltaje de Linea 4040 VAC, 330 Kw
14:00
Tx1  8 Kw
Tx2 12 Kw
Tx3 20 Kw
Voltaje de Linea 3890 VAC, 310 Kw"	vquesada
Milestone 2013_07 EW_Drift + Faraday	854	08 Ju 19:45 Reinicio del experimento FARADAY	ISR		Acquisition system	Rita Abad	new	2013-07-09T14:06:15-05:00	2013-07-09T14:06:15-05:00	Luego del test realizado se deja adquiriendo.	rabad
Milestone 2013_07 EW_Drift + Faraday	853	08 Jul 14:30-19:40 Problemas de sincronizaci'on con el experimento FARADAY	ISR		Acquisition system		new	2013-07-09T14:00:45-05:00	2013-07-09T14:00:45-05:00	"-Entre las 14:30 hasta 19:40 se tuvo problemas de sincronismo en el experimento de Faraday.
-Se revisaron que los pulsos (reloj y sincronismo) estuvieran llegando bien.
-Se cambio de cable serial y se reinicio varias veces la adquisici'on.
-Se realizo un mantenimiento al CR de FARADAY.
-Se cambio el pulso de reloj externo por uno de mayor amplitud originado por el CR de EW_Drift.
-De 19:30 a 19:45 se adquirio solo ruido para revisar si aun se continuaban viendo los pulsos de EW_Drift en los 'ultimos ocho IPPs de Faraday.

"	rabad
Milestone 2013_07 EW_Drift + Faraday	852	08 Jul 23:58 Plots de EW_Drift	ISR		Plot	I. Manay	new	2013-07-09T00:44:25-05:00	2013-07-09T00:44:25-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	851	08 Jul 23:55 Plots de Faraday	ISR		Plot	I. Manay	new	2013-07-09T00:04:55-05:00	2013-07-09T00:04:55-05:00		rabad
Milestone 2013_07 EW_Drift + Faraday	850	08 Jul 21:34 Problemas con experimento EW_Drift	ISR		Acquisition system	I. Manay	new	2013-07-08T22:27:10-05:00	2013-07-08T22:27:10-05:00	Datos movidos en altura.	imanay
Milestone 2013_07 EW_Drift + Faraday	849	08 Jul 21:01 Experimento Faraday fue reestablecido	ISR		Acquisition system	I. Manay	new	2013-07-08T22:08:59-05:00	2013-07-08T22:08:59-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	848	08 Jul 21:00 Calibración de ATR's y TR's	ISR		Spark Gaps	A. Coronado	new	2013-07-08T22:04:15-05:00	2013-07-08T22:04:15-05:00		imanay
Milestone 2013_07 EW_Drift + Faraday	847	08 Jul 20:50 Problemas con experimento Faraday	ISR		Acquisition system	I. Manay	new	2013-07-08T21:57:44-05:00	2013-07-08T21:59:56-05:00	Datos de Faraday movidos en altura. Los valores indicados por los displays del controlador de radar variaban. Se reinició todo el sistema Faraday, incluyendo la PC de adquisición (Clon de PC radar)	imanay
Milestone 2013_07 EW_Drift + Faraday	846	08 Jul 19:45 Problemas con experimento Faraday	ISR		Acquisition system	I. Manay	new	2013-07-08T21:34:53-05:00	2013-07-08T21:34:53-05:00	Se reinició el experimento Faraday usando el clon de PC Radar. Se configuró controlador de radar, DDS y se corrió el batch de adquisición.	imanay
Milestone 2013_07 EW_Drift + Faraday	845	08 Jul 14:06 Calibraci'on de ATR's y TR's	ISR		Spark Gaps		new	2013-07-08T14:16:21-05:00	2013-07-08T14:16:21-05:00	- Calibraci'on de chisperos.	rabad
Milestone 2013_07 EW_Drift + Faraday	844	08 Jul 13:10 Se reinicia experimento FARADAY	ISR		Acquisition system		new	2013-07-08T13:32:39-05:00	2013-07-08T13:32:39-05:00	"- Se cambia PC RADAR por un clon.

- Se reinicia adquisici'on de FARADAY con la nueva PC."	rabad
Milestone 2013_07 EW_Drift + Faraday	843	08 Jul 12:14 Problemas transmisores	ISR		Start experiment		new	2013-07-08T12:26:29-05:00	2013-07-08T12:26:29-05:00	"- Ca'ida de tensi'on en transmisores.
- Se repone de inmediato."	rabad
Milestone 2013_07 EW_Drift + Faraday	842	08 Jul 11:06 Se cuelga PC RADAR (Faraday)	ISR		Acquisition system		new	2013-07-08T12:09:42-05:00	2013-07-08T12:09:42-05:00	"- PC Radar no bootea. 
- Por el momento no se va tomar Faraday hasta que se logre levantar el clon de PC RADAR."	rabad
Milestone 2013_07 EW_Drift + Faraday	840	08 Jul 11:52 Se restablece transmisores	ISR		Transmitters		new	2013-07-08T12:04:56-05:00	2013-07-08T12:04:56-05:00	- se repone transmisores, sale experimento EW_Drift.	rabad
Milestone 2013_07 EW_Drift + Faraday	839	08 Julio 11:47 Problemas en transmisores	ISR		Transmitters		new	2013-07-08T12:01:53-05:00	2013-07-08T12:01:53-05:00	- Ca'ida de tensi'on.	rabad
Milestone 2013_07 EW_Drift + Faraday	838	08 Julio 10:56 Calibraci'on de ATR's y TR's	ISR		Spark Gaps		new	2013-07-08T11:15:24-05:00	2013-07-08T11:15:24-05:00	-Calibraci'on de chisperos.	rabad
Milestone 2013_07 EW_Drift + Faraday	837	08 Julio 10:46 Se reinicia adquisici'on de Faraday	ISR		Acquisition system		new	2013-07-08T11:00:32-05:00	2013-07-08T11:00:32-05:00	- Se desincronizaci'on de datos de PC-RADAR, experimento Faraday.	rabad
Milestone 2013_07 EW_Drift + Faraday	836	08 Julio 08:30 Se reinicia el experimento EW_Drift+Faraday	ISR		General		new	2013-07-08T10:10:08-05:00	2013-07-08T10:10:08-05:00	"- Se reinicia varias veces debido a que se desincroniza el Controlador de Radar de Faraday.

- Se reprograma Controlador de Faraday. "	rabad
Milestone 2013_07 EW_Drift + Faraday	835	08 Julio 08:00 Inicio del experimento EW_Drift+Faraday	ISR		Start experiment		new	2013-07-08T09:53:18-05:00	2013-07-08T09:53:18-05:00	- Se inicia el experimento EW_Drift+Faraday.	rabad
Milestone 2013_07 EW_Drift + Faraday	834	05 Julio 2013 18:30 prueba de experimento Faraday	ISR	JRO Staff	Process/Analysis Program	Luis Condori	new	2013-07-05T19:51:38-05:00	2013-07-05T19:51:38-05:00	Prueba con datos validos (30 minutos de prueba), los resultados se ven bien.	lcondori
Milestone 2013_07 EW_Drift + Faraday	833	04 Jul 10:01 Log for experiment Jul EW Drift + Faraday Activated	ISR	Others	Start experiment		new	2013-07-04T10:12:39-05:00	2013-07-04T10:12:39-05:00	The log has been created	ryanque
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	1456	04 Abr  12:30 Transmitter Power mesearuments	ISR		Transmitters		new	2014-04-04T09:39:54-05:00	2014-04-04T09:39:54-05:00	"04/04/2014
08:00 TX Power sample (-70 dB coupling)
1 +6.1 dBm
2 +1.3 dBm/ +4.5 dBm
4 +1.8 dBm
Voltage line and power: 3950 VAC, 295 KW 
09:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +1.2 dBm/ +4.2 dBm
4 +1.4 dBm
Voltage line and power: 3800 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +1.2 dBm/ +4.2 dBm
4 +1.4 dBm
Voltage line and power: 3800 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
1 +5.8 dBm
2 +1.3 dBm/ +4.4 dBm
4 +1.6 dBm
 
12:00 TX Power sample (-70 dB coupling)
1 +6.2 dBm
2 +1.6 dBm/ +4.6 dBm
4 +2.0 dBm
Voltage line and power: 4000 VAC, 300 KW
----------------------------------------
12:30 End (off transmitter)"	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	1119	05 de Noviembre 2013 04:15 Lectura de Potencias	ISR		Transmitters		new	2013-11-05T03:16:52-05:00	2013-11-05T03:16:52-05:00	"05 de Noviembre
00:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
01:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
02:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
03:00
Tx1: +6.2 dBm
Tx2: +1.9, +5 dBm 
Tx4: +1.8 dBm
Voltaje de linea:4000 Vac, 300 Kw
04:00
Tx1: +5.4 dBm
Tx2: +1.8, +5 dBm 
Tx4: +1.6 dBm
Voltaje de linea:3950 Vac, 300 Kw"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	1083	08 Oct 01:00 Datos en Madrigal	ISR+Imaging		Process/Analysis Program		new	2013-10-08T00:25:05-05:00	2013-10-08T00:25:05-05:00	Los datos procesados esta en Madrigal.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	832	03 May 08:30 EW_Drifts plots	ISR+Imaging		Plot	P Condor	new	2013-05-03T08:30:11-05:00	2013-05-03T08:30:11-05:00		pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	831	03 May 08:25 Faraday Plots	ISR+Imaging		Plot	P Condor	new	2013-05-03T08:27:41-05:00	2013-05-03T08:41:00-05:00		pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	830	03 May 07:00 Lecturas de Potencia	ISR		Transmitters	Victor Quesada	new	2013-05-03T07:22:39-05:00	2013-05-16T13:06:56-05:00	"03 de Mayo 2013
00:00 S conecta TR EW-DRIFT
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 14 KW,4050 Vac, 300Kw
01:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 14 KW,4050 Vac, 300Kw
02:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 13 KW,4050 Vac, 300Kw
03:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 13 KW,4050 Vac, 300Kw
04:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 13 KW,4050 Vac, 300Kw
05:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 13 KW,4050 Vac, 300Kw
06:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 14 KW,4050 Vac, 300Kw
06:16 Crowbar por caida de voltaje
07:00
TX Pow. (Inc.)
1 13 KW
2 9 KW
3 14 KW,4050 Vac, 300Kw
07:12 Caida de fuente Screen PA Tx3"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	829	03 May 07:11 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-03T07:21:54-05:00	2013-05-03T07:21:54-05:00	 Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	828	03 May 06:55 Paso de la Luna	ISR+Imaging		Physical Phenomena	P Condor	new	2013-05-03T07:08:45-05:00	2013-05-03T07:08:45-05:00	Paso de la Luna. Es visto en los espectros de EW_Drifts.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	827	03 May 06:14 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-03T06:55:16-05:00	2013-05-03T06:55:16-05:00	Caida de Tx.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	826	03 May 05:39 Se cuelga pc de Faraday	ISR+Imaging		Acquisition system	P Condor	new	2013-05-03T06:54:33-05:00	2013-05-03T06:54:33-05:00	Se cuelga pc de Faraday. Se reinicia de nuevo todo.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	825	03 May 05:31 Desincronizacion de Faraday	ISR+Imaging		Acquisition system	P Condor	new	2013-05-03T06:53:20-05:00	2013-05-03T06:53:20-05:00	Desincronizacion de Faraday. Se vuelve a ejecutar el batch.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	824	03 May 05:01 Calibracion de ATRs	ISR+Imaging		Antennas	A. Belleza	new	2013-05-03T06:51:19-05:00	2013-05-03T06:51:19-05:00	Calibracion de ATRs.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	823	03 May 03:51 Desincronizacion de Faraday	ISR+Imaging		Acquisition system	P Condor	new	2013-05-03T06:49:53-05:00	2013-05-03T06:49:53-05:00	 Desincronizacion de Faraday. Se vuelve a ejecutar el batch.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	822	03 May 06:16 Crowbar	ISR		Transmitters	Victor Quesada	new	2013-05-03T06:23:22-05:00	2013-05-16T13:08:35-05:00	06:16 Crowbar por caida de voltaje	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	821	03 May 00:01 Figuras de Imaging	ISR+Imaging		Plot	P. Condor	new	2013-05-03T03:11:08-05:00	2013-05-16T13:18:50-05:00	Figuras de Imaging	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	820	03 May 00:00 Figuras de rtis, espectros, potencias, ruidos y resultados	ISR+Imaging		Plot	P Condor	new	2013-05-03T02:37:35-05:00	2013-05-16T13:19:39-05:00	Figuras de rtis, espectros, potencias, ruidos y resultados de EW_Drifts y Faraday	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	819	02 May 23:21 Ajuste de ATRs	ISR+Imaging		Antennas	A. Belleza	new	2013-05-03T02:35:17-05:00	2013-05-03T02:35:17-05:00	Ajuste de ATRs	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	818	02 May 21:47 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-03T02:34:03-05:00	2013-05-03T02:34:03-05:00	 Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	817	02 May 23:00 Lectura de Potencias	ISR		Start experiment	Victor Quesada	new	2013-05-03T00:07:29-05:00	2013-05-16T13:09:42-05:00	"
02 de mayo 2013
20:00 
TX Pow. (Inc.)
1 9 KW
2 9 KW
3 14 KW,4020 Vac, 300Kw
21:00
TX Pow. (Inc.)
1 9 KW
2 9 KW
3 14 KW,4020 Vac, 300Kw
21:44 Crowbar por caida de voltaje
22:00
TX Pow. (Inc.)
1 9 KW
2 9 KW
3 14 KW,4020 Vac, 300Kw
23:00
TX Pow. (Inc.)
1 9 KW
2 9 KW
3 14 KW,4020 Vac, 300Kw"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	816	02 May 19:00 lectura de las potencias y variacion de la linea AC	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-05-02T19:13:10-05:00	2013-05-02T19:13:10-05:00	"02 de Mayo 2013
 08:00
 Tx1 13 Kw
 Tx2 8 Kw
 Tx3 13 KW, 3900 Vac, 300 Kw
 09:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 12 KW, 3850 Vac, 300 Kw
 10:00
 Tx1 12 Kw
 Tx2 7 Kw
 Tx3 12 KW.
 11:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 12 KW
 12:00
 Tx1 13 Kw
 Tx2 9 Kw
 Tx3 13 KW, 3950 Vac, 300 Kw
 13:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 12 KW
 14:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 12 KW, 3850Vac, 290 Kw
 14:00 Falla Screen PA 2.
 15:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 12 KW
16:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 13 KW
16:03 Se desconecta el TR de EWD (32p)
17:00
 Tx1 8 Kw
 Tx2 9 Kw
 Tx3 14 KW
18:00
 Tx1 8 Kw
 Tx2 9 Kw
 Tx3 14 KW
19:00
 Tx1 8 Kw
 Tx2 9 Kw
 Tx3 14 KW."	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	815	02 May 17:57 Reinicia Adquisicion en ARES	ISR+Imaging		Acquisition system	dsuarez	new	2013-05-02T18:09:13-05:00	2013-05-16T16:31:56-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	814	02 May 17:44 Se cuelga PC ARES	ISR+Imaging		Acquisition system	dsuarez	new	2013-05-02T18:08:37-05:00	2013-05-16T16:33:15-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	813	02 May 17:32 Perdio Sincronimo EWDrifts ARES	ISR+Imaging		Acquisition system	dsuarez	new	2013-05-02T18:08:03-05:00	2013-05-16T16:34:37-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	812	02 May 17:05 El usuario local reinicia el procesamiento de Faraday	ISR+Imaging		Process/Analysis Program	dsuarez	new	2013-05-02T18:04:51-05:00	2013-05-16T16:35:14-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	811	02 May 16:05 Inicia Experimento Imaging	ISR+Imaging		Start experiment	dsuarez	new	2013-05-02T18:04:11-05:00	2013-05-16T16:37:30-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	810	02 May 16:01 El usuario local detiene el procesamiento de Faraday	ISR+Imaging		Process/Analysis Program	dsuarez	new	2013-05-02T18:03:21-05:00	2013-05-16T16:38:08-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	809	02 May 14:00 Falla de Fuente  SCREEN	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-05-02T14:17:34-05:00	2013-05-02T14:17:34-05:00	Falla de la fuente de Screen del PA 1. (2v)	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	808	29 Abr 20:00 Problemas con EW_Drift y canal A de Imaging	ISR+Imaging		Reception	Rita Abad	new	2013-05-02T14:14:31-05:00	2013-05-02T14:14:31-05:00	Debido a problemas en EW_Drift y en el canal A de Imaging se revisan cables y conexiones, por tal motivo se reconecta todo de nuevo. 	rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	807	29 Abr 19:33 Problemas con PC de procesamiento (dos monitores)	ISR+Imaging		Process/Analysis Program	Rita Abad	assigned	2013-05-02T11:34:52-05:00	2013-05-02T14:17:12-05:00	No se puede ingresar al IDL luego de ser minizada la ventana de procesamiento.  	rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	806	29 Abr 18:53 Se prenden los 03 DDS	ISR+Imaging		General	Rita Abad	new	2013-05-02T11:30:49-05:00	2013-05-02T11:30:49-05:00		rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	805	29 Abr 18:50 Se apagan los 3 DDS para verificar problemas en datos.	ISR+Imaging		General	rabad	assigned	2013-05-02T11:30:00-05:00	2013-05-02T11:48:55-05:00		rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	804	29 Abr 18:48 No se visualiza el SKY NOISE en la página web del ROJ	ISR+Imaging		General	Rita Abad	new	2013-05-02T11:28:42-05:00	2013-05-02T11:28:42-05:00		rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	803	29 Abr 18:30 Se quita RF del canal E de Imaging	ISR+Imaging		General	Rita Abad	new	2013-05-02T11:27:07-05:00	2013-05-02T11:27:07-05:00	"En el canal E de Imaging se visualiza un DC. Entonces se quita el TR y se cambia de pre-amplificador con carga. 

También se observo que el aislamiento del DDS no es suficiente, debido a que cuando se quita la RFB que se envia al Txs esta aun se ve en el procesamiento y al parecer contamina la RFA enviada a los Txs generando interferencia. Por tal motivo se desconecta el pulso que genera a la RFB en el DDS y de esta manera se elimina la interferencia que se veía en los canales de Imaging y con mayor fuerza en el canal E. (Se debería realizar un test para detectar de manera más precisa el problema)
"	rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	802	02 May 09:42 Calibración de Chisperos ATRs y TRs	ISR+Imaging		Antennas	dsuarez	new	2013-05-02T09:44:52-05:00	2013-05-16T16:38:35-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	801	01 May 22:03 Crowbar por caida del voltaje	ISR+Imaging		Transmitters	Victor Quesada	new	2013-05-02T08:23:20-05:00	2013-05-02T08:23:20-05:00	Crowbar por caida del voltaje	rabad
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	800	02 May  07:00 se colgo PC- ARES (EW Drift)	ISR+Imaging		Acquisition system	Marcos Inonan	assigned	2013-05-02T07:50:50-05:00	2013-05-02T10:25:01-05:00		minonan
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	799	02 May 08:00 Lectura de Potencias	ISR+Imaging		Transmitters	Victor Quesada	new	2013-05-02T07:07:39-05:00	2013-05-02T10:07:58-05:00	"02 de Mayo 2013
00:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
01:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
02:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
03:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
04:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
05:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
06:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw
06:54 Crowbar por caida de voltaje
07:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 14 KW, 4080 Vac, 320 Kw"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	798	01 May 24:00 Figuras de rtis, espectros, ruido y Parametros EW Drift	ISR		Plot		new	2013-05-02T06:21:31-05:00	2013-05-16T15:26:34-05:00		minonan
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	797	02 May 00:00 Lectura de Potencias	ISR+Imaging		Transmitters	Victor Quesada	assigned	2013-05-02T00:44:49-05:00	2013-05-16T13:13:38-05:00	"01 de Mayo 2013
20:00
Tx1 9 Kw
Tx2 9 Kw
Tx3 18 KW, 4080 Vac, 320 Kw
21:00
Tx1 9 Kw
Tx2 9 Kw
Tx3 18 KW, 4080 Vac, 320 Kw
22:00
Tx1 9 Kw
Tx2 9 Kw
Tx3 18 KW, 4080 Vac, 320 Kw
22:03 y 22:07 Crowbar con caida de voltaje
23:00
Tx1 9 Kw
Tx2 9 Kw
Tx3 18 KW, 4080 Vac, 320 Kw
23:12 Crowbar con caida de voltaje"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	796	01 May 24:00 Figuras de rtis, espectros, ruido y Parametros	ISR		Plot		new	2013-05-02T00:13:09-05:00	2013-05-16T16:36:06-05:00		minonan
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	795	01 May 23:12 Crowbar	ISR+Imaging		Transmitters	Victor Quesada	assigned	2013-05-01T23:14:18-05:00	2013-05-02T10:25:55-05:00	crowbar por caida de  voltaje	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	794	01 May 20:07 Crowbar	ISR+Imaging		Transmitters	Victor Quesada	assigned	2013-05-01T22:10:34-05:00	2013-05-02T10:26:23-05:00	Crowbar por caida del voltaje	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	793	01 May 21:00 PC de procesamiento colgada	ISR+Imaging		Process/Analysis Program	Marcos Inonan	assigned	2013-05-01T21:25:32-05:00	2013-05-16T13:11:21-05:00	Se colgo la pc de procesamiento. Se reinicio luego de 10 minutos.	minonan
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	792	01 May 19:58 Resumen lectura de potencias TX	ISR+Imaging		Transmitters	Rommel	new	2013-05-01T19:57:28-05:00	2013-05-02T10:19:40-05:00	"08:00 TX     Pow. (Inc.)
       1     14 KW
       2      8 KW
       3     17 KW
09:00 TX     Pow. (Inc.)
       1     14 KW
       2      8 KW
       3     17 KW
10:00 TX     Pow. (Inc.)
       1     14 KW
       2      9 KW
       3     16 KW
11:00 TX     Pow. (Inc.)
       1     13 KW
       2      8 KW
       3     16 KW
12:00 TX     Pow. (Inc.)
       1     14 KW
       2      9 KW
       3     17 KW
13:00 TX     Pow. (Inc.)
       1     14 KW
       2      9 KW
       3     17 KW
14:00 TX     Pow. (Inc.)
       1     14 KW
       2      9 KW
       3     17 KW
15:00 TX     Pow. (Inc.)
       1     14 KW
       2      9 KW
       3     17 KW
16:00 TX     Pow. (Inc.)  Cambio de pulso TX 1
       1      8 KW
       2      8 KW
       3     17 KW
17:00 TX     Pow. (Inc.)
       1      8 KW
       2      8 KW
       3     17 KW
18:00 TX     Pow. (Inc.)
       1      8 KW
       2      8 KW
       3     17 KW
19:00 TX     Pow. (Inc.)
       1      8 KW
       2      8 KW
       3     17 KW"	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	791	01 May 19:35 Se cambia TR de canal B	ISR+Imaging		Acquisition system	P Condor	new	2013-05-01T19:39:38-05:00	2013-05-02T10:27:31-05:00	 Se cambia TR de canal B-EW_Drifts porque  habia mas de 1 db de diferencia de ruido con canal A.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	790	01 May 18:47 Se colgo ARES	ISR+Imaging		Process/Analysis Program	P Condor	new	2013-05-01T19:19:32-05:00	2013-05-02T10:27:48-05:00	Se colgo la PC ARES. Se vuelve a iniciar el batch de EW_Drifts.	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	789	01 May 16:25 Calibracion de ATRs y TRs	ISR+Imaging		Antennas	W. Rojas	new	2013-05-01T19:17:34-05:00	2013-05-02T10:28:16-05:00	Calibracion de los ATRs y TRs	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	788	01 May 15:41 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-01T19:16:40-05:00	2013-05-02T10:28:36-05:00	Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	787	01 May 14:16 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-01T19:16:06-05:00	2013-05-02T10:28:59-05:00	Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	786	01 May 13:18 Calibracion de TRs y ATRs	ISR+Imaging		Antennas	W Rojas	new	2013-05-01T19:15:29-05:00	2013-05-02T10:31:04-05:00	Calibracion de los TRs y ATRs	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	785	01 May 12:39 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-01T19:14:24-05:00	2013-05-02T10:31:20-05:00	Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	784	01 May 10:40 Falla en Transmisor de Faraday	ISR+Imaging		Transmitters	P Condor	new	2013-05-01T19:13:32-05:00	2013-05-02T10:36:30-05:00	 Falla en Transmisor de Faraday, se arregla	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	783	01 May 10:26 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-01T19:12:16-05:00	2013-05-02T10:36:20-05:00	 Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	782	01 May 10:20 Calibracion de los TRs y TRs	ISR+Imaging		Start experiment	W. Rojas	new	2013-05-01T19:11:22-05:00	2013-05-02T10:36:09-05:00	Calibracion de los TRs y TRs	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	781	01 May 09:27 Caida de Tx	ISR+Imaging		Transmitters	P Condor	new	2013-05-01T19:10:17-05:00	2013-05-02T10:35:59-05:00	Caida de Tx	pcondor
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	780	01 May 18:10 Falla interlock PA1	ISR+Imaging		Transmitters	Rommel	new	2013-05-01T18:12:57-05:00	2013-05-02T10:35:47-05:00	Problema con interlock PA1 que deshabilita su fuente de SCREEN quitando permiso de RF de los transmisores.	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	779	01 May 15:40 Falla fuente principal	ISR+Imaging		Transmitters	Rommel	new	2013-05-01T15:47:05-05:00	2013-05-02T10:35:33-05:00	Falla fuente 20 KV	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	778	01 May 14:16 Falla fuente principal	ISR+Imaging		Transmitters	Rommel	new	2013-05-01T14:18:09-05:00	2013-05-02T10:35:23-05:00	Falla fuente 20 KV	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	777	01 May 12:40 Falla interlock PA1	ISR+Imaging		Transmitters	Rommel	new	2013-05-01T12:42:22-05:00	2013-05-02T10:35:08-05:00	Falla de interlock PA2 deshabilita su fuente de SCREEN quitando permiso de RF principal.	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	776	01 May 10:40 Falla rele de permiso RF PA3	ISR+Imaging		Transmitters	Rommel	new	2013-05-01T12:02:38-05:00	2013-05-02T10:34:58-05:00	Falla en rele de permiso RF PA3, se cambia de contacto del rele de permiso de RF principal asumiendo contacto defectuoso que afecta a los permisos individuales de cada PA. 	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	775	01 May 10:40 Falla rele de permiso de RF PA2	ISR		Transmitters	Rommel	new	2013-05-01T10:43:59-05:00	2013-05-16T15:44:55-05:00	Falla rele de permiso de RF individual del PA2, se cambia por rele auxiliar.	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	774	1 May 10:32 Falla rele de permiso RF	ISR		Transmitters	Rommel	new	2013-05-01T10:35:50-05:00	2013-05-16T15:37:29-05:00	Se presenta falla en el rele de permiso de RF de los transmisores, se restablece des-habilitado y volviendo a habilitar el permiso de RF	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	773	01 May 10:27 Falla fuente principal	ISR		Transmitters	Rommel	new	2013-05-01T10:29:53-05:00	2013-05-16T15:38:22-05:00	Falla fuente principal 20 KV	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	772	01 May 09:27 Falla Interlock	ISR		Transmitters	Rommel	new	2013-05-01T09:31:03-05:00	2013-05-16T15:39:34-05:00	Falla interlock PA2, se des-habilita fuente Screen PA2 que des-habilita permiso de RF de los transmisores.	ryaya
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	771	01 May 07:33 Calibracion de ATR's y TR's	ISR+Imaging		Antennas	A. Coronado	new	2013-05-01T07:43:03-05:00	2013-05-02T10:34:44-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	770	01 May 03:00 Lectura de potencias	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-05-01T07:23:26-05:00	2013-05-16T13:14:36-05:00	"03:00
 Tx1 13 Kw
 Tx2 8 Kw
 Tx3 16 Kw
 04:00
 Tx1 13 Kw
 Tx2 8 Kw
 Tx3 16 Kw.
 05:00
 Tx1 13 Kw
 Tx2 8 Kw
 Tx3 16 Kw, 4000 Vac, 300 Kw
 06:00
 Tx1 13 Kw
 Tx2 9 Kw
 Tx3 17 Kw.
 07:00
Tx1 14 Kw
 Tx2 9 Kw
 Tx3 18 Kw, 4050 Vac, 310 Kw.
"	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	769	01 May 05:01 Se reinicia adquisición de PC Ares.	ISR+Imaging		Acquisition system	I. Manay	new	2013-05-01T05:06:25-05:00	2013-05-02T10:34:20-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	768	01 May 04:57 Se cuelga PC Ares.	ISR+Imaging		Acquisition system	I. Manay	new	2013-05-01T05:05:34-05:00	2013-05-02T10:34:06-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	767	01 May 03:00 Calibración de ATR's y TR's	ISR+Imaging		Antennas	A. Coronado	new	2013-05-01T03:07:34-05:00	2013-05-02T10:33:49-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	766	01 May 02:48 Falla de Fuente de Screen	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-05-01T02:54:36-05:00	2013-05-02T10:33:37-05:00	PA 2	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	765	01 May 02:00 Falla de Fuente de HV	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-05-01T02:29:52-05:00	2013-05-02T10:33:25-05:00	Circuito Crowbar	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	764	01 May 02:00 Variacion de la potencia y lineas de  AC	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-05-01T02:28:50-05:00	2013-05-02T10:32:45-05:00	"30 Abril del 2013
 20:00
 Tx1 9 Kw
 Tx2 9 Kw
 Tx3 18 Kw, 4060 Vac, 310 Kw.
 21:00
 Tx1 9 Kw
 Tx2 9 Kw
 Tx3 18 Kw, 4060 Vac, 310 Kw.
 22:00
 Tx1 9 Kw
 Tx2 9 Kw
 Tx3 17 Kw, 3900 Vac, 310 Kw
 23:00
 Tx1 8 Kw
 Tx2 8 Kw
 Tx3 16 Kw, 3900 Vac, 300 Kw.
 00:00
Se conecta TR
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 16 Kw, 3900 Vac, 300 Kw.
 01:00
 Tx1 12 Kw
 Tx2 8 Kw
 Tx3 16 Kw
 02:00
 Tx1 13 Kw
 Tx2 8 Kw
 Tx3 17 Kw, 3900 Vac, 300 Kw."	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	763	01 May 00:14 Error de logs en carga de gráficos de Imaging	ISR+Imaging		Plot	I. Manay	new	2013-05-01T00:17:28-05:00	2013-05-02T10:32:30-05:00	Gráficos de RTi y Coherencia de Imaging son mayores a 1Mbyte. Cuando se trata de adjuntar en el logs reporta un error que el máximo tamaño de archivo adjunto es de 262Kbyte.	imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	762	01 May 00:03 Imaging Plots	ISR+Imaging		Plot	I. Manay	new	2013-05-01T00:04:09-05:00	2013-05-02T10:32:08-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	761	30 Abr 23:13 Calibración de ATR's y TR's	ISR+Imaging		Antennas	A. Coronado	new	2013-04-30T23:58:03-05:00	2013-05-02T10:31:48-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	760	30 Abr 23:55 Faraday Plots	ISR+Imaging		Plot	I. Manay	new	2013-04-30T23:52:15-05:00	2013-05-02T10:31:35-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	759	30 Abr 23:50 EW_Drift plots	ISR+Imaging		Plot	I. Manay	new	2013-04-30T23:49:25-05:00	2013-05-02T10:29:16-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	758	30 Abr 21:27 Se cuelga PC Ares. Se reinicia PC y adquisición	ISR+Imaging		Acquisition system	I. Manay	new	2013-04-30T21:38:44-05:00	2013-05-02T10:28:04-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	757	30 Abr 20:27 Se produce cambio de turno	ISR+Imaging		General	I. Manay	new	2013-04-30T20:47:47-05:00	2013-05-02T10:24:28-05:00		imanay
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	756	30 Abr 18:52 Ajuste de Chisperos TRs y ATRs	ISR+Imaging		Antennas	dsuarez	new	2013-04-30T19:16:52-05:00	2013-05-16T16:36:58-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	755	30 Abr 16:40 Ajuster de chisperos TRs y ATRs	ISR+Imaging		Antennas	dsuarez	new	2013-04-30T19:16:04-05:00	2013-05-16T16:39:24-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	754	30 Abr 20:00 Lectutra de Potencias	ISR+Imaging		Transmitters	Victor Quesada	assigned	2013-04-30T19:09:58-05:00	2013-05-02T11:43:49-05:00	"30 de Abril 2013
13:00
Tx1 14 Kw
Tx2  9 Kw
Tx3 17 Kw, 4050 Vac, 310 Kw.
14:00
Tx1 13 Kw
Tx2  9 Kw
Tx3 17 Kw, 4050 Vac, 310 Kw.
15:00
Tx1 13 Kw
Tx2  8 Kw
Tx3 16 Kw, 4050 Vac, 310 Kw
16:00
Se desconecto TR EW-DRIFT en el panel de Tomp B
Tx1  7 Kw
Tx2  9 Kw
Tx3 16 Kw, 3900 Vac, 300 Kw.
17:00
Tx1  9 Kw
Tx2  9 Kw
Tx3 18 Kw, 3900 Vac, 300 Kw.
18:00
Tx1  9 Kw
Tx2  9 Kw
Tx3 17 Kw, 4050 Vac, 310 Kw
19:00
Tx1  9 Kw
Tx2  9 Kw
Tx3 19 Kw, 3900 Vac, 300 Kw.
"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	753	30 Abr 16:05 Inicia Adquisicion con JARS para IMAGING	ISR+Imaging		Start experiment	dsuarez	new	2013-04-30T16:34:21-05:00	2013-05-16T16:40:04-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	752	30 Abr 13:28 Ajuste de chisperos ATRs y TRs	ISR		Antennas	dsuarez	new	2013-04-30T16:33:06-05:00	2013-05-16T16:45:31-05:00		dsuarez
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	751	30 Abr 12:00 Lectura de Potencias	ISR+Imaging		Transmitters		new	2013-04-30T12:52:25-05:00	2013-05-16T15:48:11-05:00	"30 de Abril 2013
08:00
Tx1 9 Kw
Tx2 9 Kw
Tx3 16 Kw, 4050 Vac, 310 Kw.
08:10 Se conecta TR EW-DRIFT
09:00
Tx1 16 Kw
Tx2  9 Kw
Tx3 16 Kw, 4050 Vac, 310 Kw.
09:06 Cae fuente de screen PA Tx1.
09:58 Cae fuente de screen y fuente HV
10:00
Tx1 13 Kw
Tx2 8 Kw
Tx3 16 Kw, 4050 Vac, 310 Kw
11:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 15 Kw, 3900 Vac, 300 Kw.
12:00
Tx1 13 Kw
Tx2 9 Kw
Tx3 17 Kw, 3900 Vac, 300 Kw.
"	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	750	30 Abr 09:58 Crowbar	ISR+Imaging		Transmitters		new	2013-04-30T10:05:34-05:00	2013-05-16T15:53:37-05:00	09:58 Cae fuente de Screen PA Tx1, Tambien cae fuente HV	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	749	30 Abr 09:06 Cae  Fuentre de Screen TX1	ISR		Transmitters		new	2013-04-30T09:09:16-05:00	2013-05-16T15:52:11-05:00	09:06 Cae fuente de screen  PA Tx1	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	748	30 Abr 08:10 TR EW-DRIFT	ISR+Imaging		Transmitters		new	2013-04-30T08:18:01-05:00	2013-05-16T15:41:47-05:00	08:10 Se conecta TR EW-Drift(32 Pulsos al Tx1)	vquesada
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	747	30 Abr 07:09 Falla por el circuito crowbar	ISR+Imaging		Transmitters	rtadeo	new	2013-04-30T07:20:03-05:00	2013-05-02T10:22:05-05:00	Caida de la fuente de alta por variacion en la linea AC (Crowbar)	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	746	30 Abr 06:33 Calibracion de sprak gaps	ISR		Spark Gaps	dcordova	assigned	2013-04-30T06:35:33-05:00	2013-05-16T16:47:49-05:00	"Se calibraron los chispero en las siguientes horas:
01:36
05:55
"	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	745	30 Abr 04:32 Problema con el sistema de adquisicion de EWDRIFT	ISR		Acquisition system	dcordova	assigned	2013-04-30T06:33:47-05:00	2013-05-16T16:46:46-05:00	"Se congelo de nuevo la pc EWDRIFT de adquisicion, se reinicio esta y se copiaron los archivos a partir del set 29, 4:39 Se reinicio la adquisicion, pero, esta vez, la adquisiion comenzo en el siguiente set respecto del ultimo
"	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	744	30 Abr 03:15 Problema de desincronizacion con el sistema de adquisicion de Faraday	ISR		Start experiment	dcordova	assigned	2013-04-30T06:30:21-05:00	2013-05-16T16:49:31-05:00	Se desincronizaron los datos de Faraday, se volvio a cargar pulsos y reiniciar adquisicion 	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	743	30 Abr 03:07 Problema con el sistema de adquisicion de EWDRIFT	ISR		Acquisition system	dcordova	assigned	2013-04-30T06:28:07-05:00	2013-05-16T16:42:01-05:00	"Fallo la adquisicion de la PC de EWDrift, se observo que se congelo la pantalla y aparecia un mensaje de error en un archivo, este mensaje aparecio en la barra inferior derecha. 
Se reinicio la PC y salio mensaje de revision de disco por error por el chkdks, el cual omiti para iniciar la adquisision. Se inicio la adquisision pero se observo que esta comenzo en el set 29, como el ultimo set era el 50, comenzo a sobreescribir en los archivos.
Luego se movio los datos al desktop para que los nuevos archivos no modifiquen a los antiguos, se observo que este proceso era lento; se corrio la adquisicion y se colgo, de nuevo, la pc.
Se reinicio la pc y en esta ocasion se paso el chkdsk, los datos se trasladaron de c: a f:, se observo que el traslado fue mucho mas rapido. 
4:00 Se reinicio la adquisicion y comenzo a adquirir a partir del set 29.
"	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	742	30 Abr 06:11 Falla de Screen	ISR+Imaging	Others	Transmitters	rtadeo	assigned	2013-04-30T06:18:29-05:00	2013-05-02T10:21:41-05:00	Falla de la fuente Screen del PA 3.	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	741	30 Abr 05:53 Falla circuito crowbar	ISR+Imaging		Transmitters	rtadeo	new	2013-04-30T06:03:12-05:00	2013-05-02T10:20:31-05:00	Caida de alta por Crowbar	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	740	30 Abr 04:40 Se habilita la RF de TX3	ISR+Imaging		Transmitters	rtadeo	new	2013-04-30T04:53:13-05:00	2013-05-02T10:20:10-05:00		rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	739	30 Abr 04:35 Se deshabilita la RF del TX3	ISR+Imaging		Transmitters	rtadeo	new	2013-04-30T04:51:57-05:00	2013-05-02T10:15:21-05:00	Falla de la PC d Adq.	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	738	30 Abr 04:07 Se deshabilita la RF de tx3	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-04-30T04:50:12-05:00	2013-05-02T10:14:56-05:00	Se habilita los pulsos de EW-Drift	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	737	30 Abr 03:26 Se habilita la RF de TX1 y TX2	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-04-30T04:39:02-05:00	2013-05-02T10:14:20-05:00	se Habilita los pulsos de Faraday	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	736	30 Abr 03:00 Se deshabilita la RF	ISR+Imaging	Others	Transmitters	rtadeo	new	2013-04-30T04:36:14-05:00	2013-05-02T10:13:42-05:00	(FAlla)no responde la PC de Adq. de EW_drift	rtadeo
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	735	30 Abr 00:00 Detiene JARS	ISR		Acquisition system	dcordova	assigned	2013-04-30T00:29:23-05:00	2013-05-16T16:48:39-05:00	"Se detiene JARS a medianoche y se conecta cable de CR a DDS.
Se apago CR y JARS"	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	734	30 Abr 00:00 Imagenes de Drift y Faraday	ISR		Plot	dcordova	assigned	2013-04-30T00:05:51-05:00	2013-05-16T15:28:22-05:00		dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	733	29 Abr 23:00 Observacion respecto al procesamiento de Imagenes	ISR		Process/Analysis Program	dcordova	assigned	2013-04-29T22:58:59-05:00	2013-05-16T16:50:15-05:00	23:00 Se observa que los datos mostrados entre el procesamiento y la adquisiscion es de 2 minutos, asi se encontro este desfase de tiempo desde las 8pm	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	732	29 Abr 22:10 Problema con seleccion de monitor de procesamiento	ISR		General	dcordova	assigned	2013-04-29T22:56:42-05:00	2013-05-16T16:52:51-05:00	"22:10 Problema con el KVM de la pc de procesamiento, el tercer monitor compartido entre Faraday+EWDridft e Imaging, no vuelve a seleccionar monitor de PC de Imaging, por ello se conecta otro monitor, luego se continua en este modo de manera normal
"	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	731	"29 Abr 20:00 Arco en linea de 6"" de Tx1"	ISR		General	dcordova	assigned	2013-04-29T22:22:19-05:00	2013-05-16T16:53:15-05:00	20:00 Se escucha arco electrico en linea de Tx1, se apagan los tranmisores; se revisa la linea y encuentra linea floja en el zotano, se corrige y vuelve a levantar el Tx	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	730	29 Abr 21:15 Finaliza reconexion de lineas	ISR		General	dcordova	assigned	2013-04-29T21:39:41-05:00	2013-05-16T16:54:14-05:00	"8:00 Se volvio a reconectar cables de los 3 experimentos por alta coherencia en experimento EW-Drift, luego se revisaron los cables y retiraron dos cables rg58 y se observo que la coherencia mejoro.
Posteriormente, se encontro que el canal A de imagenes tenia mucho ruido, se reviso esa linea y encontro que el cable de entrada a JARS fallaba, se reemplazo este y se arreglo la señal de ruido."	dcordova
Milestone 2013_04_1 EW_Drift+Faraday+Imaging 29/04-03/05	729	29 Abr 17:40 VSWR de cada cuarto de antena	ISR+Imaging		Start experiment		new	2013-04-29T17:49:07-05:00	2013-05-02T08:24:35-05:00	"WUP 1.03
WDN 1.03
NDN 1.07
NUP 1.09
EUP 1.09
EDN 1.08
SDN 1.07
SUP 1.02"	ryanque
Milestone 2013_04 EW_Drift+Faraday+Imaging	1085	08 Oct 01:30 Datos en Madrigal	ISR+Imaging		Process/Analysis Program		new	2013-10-08T00:30:26-05:00	2013-10-08T00:30:26-05:00	Los datos procesados estan en Madrigal.	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	726	13 Abr 08:27 Caída de tensión - transmisores	ISR+Imaging		Transmitters		new	2013-04-22T17:34:11-05:00	2013-04-22T17:34:11-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	725	13 Abr 05:43 Calibración de ATR´s y TR´s	ISR+Imaging		Spark Gaps		new	2013-04-22T17:33:19-05:00	2013-04-22T17:33:19-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	724	13 Abr 04:28 Se reinicia procesamiento de IMAGING	ISR+Imaging		Process/Analysis Program		new	2013-04-22T17:32:39-05:00	2013-04-22T17:32:39-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	723	13 Abr 04:00 Se reinicia adquisición en PC JARS	ISR+Imaging		Acquisition system		new	2013-04-22T17:31:52-05:00	2013-04-22T17:31:52-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	722	13 Abr 03:43 JARS se queda sin espacio en el disco de datos.	ISR+Imaging		Acquisition system		new	2013-04-22T17:31:10-05:00	2013-04-22T17:31:10-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	721	13 Abr 03:10  Problemas con programa de procesamiento	ISR+Imaging		Process/Analysis Program	Rita Abad	new	2013-04-22T17:29:16-05:00	2013-04-22T17:29:16-05:00	Se reinicia procesamiento EW_Drift, problemas con la licencia de IDL y error de conexión a Internet. Luego que se recupera conexión a Internet se ejecuta nuevamente IDL.	rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	720	19 Abr 07:54 Se levanta transmisor	ISR		Transmitters	P Condor	new	2013-04-19T08:00:03-05:00	2013-04-19T08:00:03-05:00	Se levanta transmisor	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	719	19 Abr 07:49 Caida de transmisor	ISR		Transmitters	P Condor	new	2013-04-19T07:59:24-05:00	2013-04-19T07:59:24-05:00	Caida de transmisor	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	718	19 Abr 07:45 Falla de fuente de HV driver	ISR		Transmitters	rtadeo	new	2013-04-19T07:59:22-05:00	2013-04-19T07:59:22-05:00	"Falla de fuente de 10kv que alimenta al driver 1 y 2.

Ademas se quemo el indicador luminoso de la fuente de screen del Driver 2 "	rtadeo
Milestone 2013_04 EW_Drift+Faraday+Imaging	717	19 Abr 07:17 Se reinicia PC de Faraday	ISR		Acquisition system	P Condor	new	2013-04-19T07:58:11-05:00	2013-04-19T07:58:11-05:00	Se reinicia PC de Faraday, se colgo	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	716	19 Abr 07:07 Falla de fuente de Screen	ISR	Others	Transmitters	rtadeo	new	2013-04-19T07:31:00-05:00	2013-04-19T07:31:00-05:00	falla Screen	rtadeo
Milestone 2013_04 EW_Drift+Faraday+Imaging	715	19 Abr 06:59 Se reinicia batch de Faraday	ISR		Acquisition system	P Condor	new	2013-04-19T07:05:10-05:00	2013-04-19T07:05:10-05:00	Se reinicia batch de Faraday, se empieza a adquirir de nuevo.	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	714	18 Abr 24:00 Figuras de rtis, espectros, ruido y Parametros	ISR		Plot	P Condor	new	2013-04-19T06:53:45-05:00	2013-05-16T16:58:45-05:00	Figuras de rtis, espectros, ruido y resultados	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	713	19 Abr 06:41 Ajuste de TRs y ATRs	ISR		Antennas	A. Coronado	new	2013-04-19T06:46:04-05:00	2013-04-19T06:46:04-05:00	Ajuste de TRs y ATRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	712	19 Abr 06:32 Caida de transmisor	ISR		Transmitters	P Condor	new	2013-04-19T06:45:02-05:00	2013-04-19T06:45:02-05:00	Caida de transmisor	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	711	19 Abr 05:57 Caida de transmisor	ISR		Transmitters	P Condor	new	2013-04-19T06:44:18-05:00	2013-04-19T06:44:18-05:00	Caida de transmisor	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	710	19 Abr 06:30 Falla de fuente de HV	ISR	Others	Transmitters	rtadeo	new	2013-04-19T06:42:36-05:00	2013-04-19T06:42:36-05:00	Circuito Crowbar	rtadeo
Milestone 2013_04 EW_Drift+Faraday+Imaging	709	19 Abr 05:55 Falla de fuente de HV	ISR	Others	Transmitters	rtadeo	new	2013-04-19T06:41:28-05:00	2013-04-19T06:41:28-05:00	Circuito Crowbar	rtadeo
Milestone 2013_04 EW_Drift+Faraday+Imaging	708	19 Abr 03:39 Se reinicia Pc de Faraday	ISR		Acquisition system	P Condor	new	2013-04-19T06:40:14-05:00	2013-04-19T06:40:14-05:00	Se reinicia Pc de Faraday, porque se colgo.	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	707	18 Abr 21:55 caida de fuente de HV	ISR	Others	Transmitters	rtadeo	new	2013-04-19T06:40:08-05:00	2013-04-19T06:40:08-05:00	Circuito crowbar	rtadeo
Milestone 2013_04 EW_Drift+Faraday+Imaging	706	19 Abr 02:37 Ajuste de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-04-19T06:39:18-05:00	2013-04-19T06:39:18-05:00	Ajuste de ATRs y TRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	705	18 Abr 21:59 Ajuste de TRs y ATRs	ISR		Antennas	A. Coronado	new	2013-04-19T06:38:12-05:00	2013-04-19T06:38:12-05:00	Ajuste de TRs y ATRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	704	18 Abr 21:58 Se levanta Tx	ISR		Transmitters	P Condor	new	2013-04-19T06:36:57-05:00	2013-04-19T06:36:57-05:00	Se levanta Tx, se continua con la toma de datos.	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	703	18 Abr 21:52 Caida de transmisor	ISR		Transmitters	P Condor	new	2013-04-19T06:35:51-05:00	2013-04-19T06:35:51-05:00	Caida de transmisor	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	702	18 Abr 17:10 Se inicia Faraday pero solo ruido (sin TX)	ISR		Acquisition system	I. Manay	new	2013-04-19T06:32:42-05:00	2013-04-19T06:32:42-05:00	Se inicia Faraday pero solo ruido (sin TX)	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	701	18 Abr 17:39 Ajuste de ATrs y Trs	ISR		Antennas	w. Rojas	new	2013-04-19T06:31:08-05:00	2013-04-19T06:31:08-05:00	Ajuste de ATrs y Trs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	700	(18 Abr 19:50) Incidencias del área TX	ISR		Transmitters	Rommel	new	2013-04-18T20:02:47-05:00	2013-04-18T20:02:47-05:00	"08:00 TX    Power(Inc.)
       1       6 KW
       2       7 KW
       3      12 KW
09:00 TX    Power(Inc.)
       1       6 KW
       2       7 KW
       3      12 KW
09:30 Ajuste de sintonía Driver 1  
10:00 TX    Power(Inc.)
       1       10 KW
       2       6 KW
       3      11 KW
10:55 Se realiza verificación de excitación Driver 1
11:00 TX    Power(Inc.)
       1       11 KW
       2       8 KW
       3      13 KW
12:00 TX    Power(Inc.)
       1       12 KW
       2       8 KW
       3      14 KW
12:40 Cambio critico en la tensión de linea deshabilita transmisores. Se deshabilita PA3 y se continua solo EW DRIFT con dos TX (PA1 y PA2)
15:30 TX    Power(Inc.)
       1       5 KW
       2       7 KW
15:55 TX    Power(Inc.)
       1       5 KW
       2       12 KW
17:00 TX    Power(Inc.)
       1       0 KW      Se quitan los pulsos de este TX por exp. imagenes
       2       14 KW
18:00 TX    Power(Inc.)
       1       0 KW
       2       14 KW
19:00 TX    Power(Inc.)
       1       0 KW
       2       14 KW


"	ryaya
Milestone 2013_04 EW_Drift+Faraday+Imaging	699	(18 Abr 12:40) Variación de tensión de línea y caída del sistema de TX	ISR		Transmitters	Rommel	new	2013-04-18T17:48:26-05:00	2013-04-18T17:48:26-05:00	"Al promediar las 12:40 se presenta una variación brusca de la tensión de línea. Esta variación provoca la des-habilitación de los transmisores y el reinicio de la PC de control. 
Al intentar reiniciar la transmisión se detecta problema de sobrecarga e la fuente de alta tensión principal.
Se realizan diferentes pruebas determinándose un problema en el transmisor PA 3 por tanto se dispone no utilizarlo en adelante mientras no se corrige el error de este transmisor. "	ryaya
Milestone 2013_04 EW_Drift+Faraday+Imaging	698	(18 Abr 09:30) Problemas con Driver 1- Exp. Faraday	ISR		Transmitters	Rommel	new	2013-04-18T17:28:40-05:00	2013-04-18T17:28:40-05:00	Se encuentra problema de sintonía del Driver 1, al parecer el problema inicio el día 17 con una caída de potencia considerable en el PA 1 que se usa en el experimento de FARADAY. El día de hoy se corrige el problema encontrado notándose en los resultados del RTI de los días correspondientes (17-18/04/13).	ryaya
Milestone 2013_04 EW_Drift+Faraday+Imaging	697	18 Abr 16:30 Se inicia adquisicion de Imaging: Con TX	ISR		Acquisition system	I. Manay	new	2013-04-18T16:47:21-05:00	2013-04-18T16:47:21-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	696	18 Abr 16:00 Se inicia adquisicion de Imaging: Solo ruido	ISR		Acquisition system	I. Manay	new	2013-04-18T16:46:41-05:00	2013-04-18T16:46:41-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	695	18 Abr 15:58 Se reinicia toma de datos	ISR		Acquisition system	I. Manay	new	2013-04-18T16:40:45-05:00	2013-04-18T16:40:45-05:00	Debido a problemas con TX3, ya no se adquieren datos de Faraday. Para adquirir EW_Drift se transmite por TX2, ya no por TX3.	imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	694	18 Abr 13:00 Problemas para levantar TX	ISR		Transmitters	I. Manay	new	2013-04-18T16:36:04-05:00	2013-04-18T16:36:04-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	693	18 Abr 12:40 Caida de tension reinicia PC radar (Faraday)	ISR		Acquisition system	I. Manay	new	2013-04-18T16:35:10-05:00	2013-04-18T16:35:10-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	692	18 Abr 12:40 Caida de tension en TX	ISR		Transmitters	I. Manay	new	2013-04-18T16:34:06-05:00	2013-04-18T16:34:06-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	691	18 Abr 11:35 Calibración de ATR's y TR's	ISR		Antennas	I. Manay	new	2013-04-18T11:40:35-05:00	2013-04-18T11:40:35-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	690	18 Abr 11:20 Observacion datos de PC radar (Faraday)	ISR		Plot	I. Manay	new	2013-04-18T11:28:28-05:00	2013-04-18T11:28:28-05:00	El canal A de Faraday presenta una caida de la potencia del eco. Se sospecha que la potencia de salida del transmisor se ha reducido desde las 6pm del dia anterior.	imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	689	18 Abr 10:35 Reinicio de adquisición de PC radar (Faraday)	ISR		Acquisition system	I. Manay	new	2013-04-18T10:46:06-05:00	2013-04-18T10:46:06-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	688	18 Abr 08:28 Calibración de ATR's y TR's	ISR		Antennas	W. Rojas	new	2013-04-18T08:34:21-05:00	2013-04-18T08:34:21-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	687	18 Abr 07:00 Lectura de Potencias	ISR		Transmitters	Victor Quesada Reyes	new	2013-04-18T07:24:58-05:00	2013-05-16T16:58:07-05:00	"17 de Abril 2013
20:00
Tx1 6 Kw
Tx2 8 Kw
Tx3 13 Kw 4000 Vac 310 Kw
20:11 Cae fuente de screen PA1
20:40 HV off para ajustar linea de transmision en la Ues
21:00
Tx1 6 Kw
Tx2 8 Kw
Tx3 143Kw 4000 Vac 310 Kw
22:00
Tx1 6 Kw
Tx2 8 Kw
Tx3 13 Kw 4000 Vac 310 Kw
22:53 Crowbar por caida de voltaje
23:00
Tx1 6 Kw
Tx2 8 Kw
Tx3 13 Kw 4000 Vac 310 Kw
18 de Abril 2013
00:00
Tx1 6 Kw
Tx2 8 Kw
Tx3 13 Kw 3930Vac 300 Kw
01:00
Tx1 11 Kw
Tx2 8 Kw
Tx3 12 Kw 3930Vac 300 Kw
02:00
Tx1 11 Kw
Tx2 8 Kw
Tx3 12 Kw 4000 Vac 310 Kw
03:00
Tx1 11 Kw
Tx2 8 Kw
Tx3 12 Kw 4000 Vac 310 Kw
04:00
Tx1 6 Kw
Tx2 7 Kw
Tx3 12 Kw 3900Vac 300 Kw
05:00
Tx1 6 Kw
Tx2 7 Kw
Tx3 12 Kw 3900 Vac 300 Kw
06:00
Tx1 6 Kw
Tx2 7 Kw
Tx3 12 Kw 3900 Vac 300 Kw
07:00
Tx1 6 Kw
Tx2 7 Kw
Tx3 12 Kw 3900 Vac 300 Kw"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	686	18 Abr 07:17 Ruidos de los experimentos	ISR		Start experiment		new	2013-04-18T07:19:45-05:00	2013-05-16T16:59:36-05:00	"7:17 Se anotan los ruidos de los experimentos:
Faraday Noise
A: 48 dB
B: 48 dB
Drift Noise
A: 27.53 dB B: 27.32 dB
C: 27.88 dB D: 28.29 dB"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	685	18 Abr 04:50 Paso de la Galaxia	ISR		Physical Phenomena		new	2013-04-18T04:59:02-05:00	2013-05-16T17:00:17-05:00		dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	684	18 Abr 04:29 Ajuste de chisperos	ISR		Spark Gaps		new	2013-04-18T04:56:29-05:00	2013-05-16T17:05:28-05:00		dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	683	18 Abr 02:48 Desincronizan datos de Faraday	ISR		Acquisition system		new	2013-04-18T04:55:51-05:00	2013-05-16T17:01:01-05:00	"2:48 Se desincronizan datos de Faraday, se detiene programa de adquisicion y RC.
2:57 Se reinicia RC y adquisicion de Faraday
3:17 Se reinicia programa de visualizacion de Ne de Faraday porque dejo de funcionar"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	682	18 Abr 01:03 Desincronizan datos de Faraday	ISR		Acquisition system		new	2013-04-18T04:53:19-05:00	2013-05-16T17:01:45-05:00	"1:03 Se desincronizan datos de Faraday, se detiene programa de adquisicion y RC.
1:09 Se reinicia RC y adquisiscion de Faraday"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	681	18 Abr 00:30 Ajuste de chisperos	ISR		Spark Gaps	dcordova	assigned	2013-04-18T00:50:47-05:00	2013-05-16T17:07:41-05:00		dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	680	18 Abr 00:46 Ruidos de los experimentos	ISR		Start experiment	dcordova	assigned	2013-04-18T00:49:50-05:00	2013-05-16T17:08:41-05:00	"23:27 Se anotan los ruidos de los experimentos:
Faraday Noise
A: 47 dB
B: 48 dB
Drift Noise
A: 27.32 dB B: 27.23 dB
C: 27.53 dB D: 27.97 dB
Se observa que el ruido de Faraday se ha restablecido a 50dB"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	679	17 Abr 23:12 Se detiene por si solo el programa de visualizacion de imagenes de IMAGING	ISR		Start experiment	dcordova	assigned	2013-04-17T23:51:30-05:00	2013-05-16T17:06:24-05:00	"23:12 Se detiene por si solo el programa de visualizacion de imagenes de IMAGING
23:25 Se vuelve a reiniciar programa de visualizacion de imagenes de IMAGING"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	678	17 Abr 23:27 Ruidos de los experimentos	ISR		Start experiment		new	2013-04-17T23:38:57-05:00	2013-05-16T17:26:25-05:00		dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	677	17 Abr 22:50 Caida de TX	ISR		General	dcordova	assigned	2013-04-17T23:21:20-05:00	2013-05-16T17:39:04-05:00	"10:50 Caen Transmisores por variacion en el voltaje de linea
10:55 Levantan transmisores"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	676	17 Abr 21:37 Ruido de los experimentos	ISR		General	dcordova	assigned	2013-04-17T21:41:43-05:00	2013-05-16T17:39:51-05:00	"21:37 Se anotan los ruidos de los experimentos:
Faraday Noise
A: 92 dB
B: 88 dB
Drift Noise
A: 26.75 dB    B: 26.38 dB
C: 27.20 dB    D: 27.48 dB
Imaging Noise
1: 44.79 dB    5: 44.81 dB
2: 42.92 dB    6: 45.63 dB
3: 42.54 dB    7: 44.42 dB
4: 44.77 dB    8: 46.16 dB
Ademas, se observa presencioa de SPread F desde las 7pm"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	675	17 Abr 20:54 Ruidos de los experimentos	ISR		Start experiment	dcordova	assigned	2013-04-17T21:37:03-05:00	2013-05-16T17:10:05-05:00	"20:54 Se anotan los ruidos de los experimentos:
Faraday Noise
A: 92 dB
B: 89 dB
Drift Noise
A: 26.56 dB    B: 26.09 dB
C: 26.80 dB    D: 27.07 dB

Se observa que el ruido en Faraday es mucho mas alto, por 40dB, que el indicado en el manual de Faraday (50dB), se realizo la consulta a P.Condor e indico que el experimento esta corriendo bien.
 "	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	674	17 Abr 20:45 Apagado temporal de transmisores	ISR		Break Experiment		new	2013-04-17T21:23:18-05:00	2013-05-16T16:56:59-05:00	"20:45 Se detiene transmisor porque se observa arco en la U de la linea NUP, se ajusta abrazaderas que se encontraba floja
20:50 Se levanta de nuevo el transmisor y no se observa arco electrico"	dcordova
Milestone 2013_04 EW_Drift+Faraday+Imaging	673	17 Abr 16:03 Se quita RF2 de EW_drift	ISR		Acquisition system	P Condor	new	2013-04-17T20:08:33-05:00	2013-04-17T20:08:33-05:00	Se quita RF2 de EW_drift, que en el DDS bajo monitor de ARES es RF1	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	672	17 Abr 16:00 Se Inicia Imaging	ISR		Acquisition system	P Condor	new	2013-04-17T20:06:57-05:00	2013-04-17T20:06:57-05:00	Se Inicia Imaging	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	671	17 Abr 15:44 Canal D de EW_Drift se calibra TR	ISR		Antennas	P Condor	new	2013-04-17T20:06:09-05:00	2013-04-17T20:06:09-05:00	Canal D de EW_Drift se calibra TR	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	670	17 Abr 18:01 Se syncronizo o se ejecuta de nuevo Faraday	ISR		Process/Analysis Program	P Condor	new	2013-04-17T20:04:36-05:00	2013-04-17T20:04:36-05:00	Se syncronizo o se ejecuta de nuevo Faraday	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	669	17 Abr 17:50 Se inicia toma de datos	ISR		Process/Analysis Program	P Condor	new	2013-04-17T20:03:25-05:00	2013-04-17T20:03:25-05:00	 Se inicia toma de datos	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	668	17 Abr 17:41 Se para todo para reiniciar el sistema	ISR		Acquisition system	P Condor	new	2013-04-17T20:02:42-05:00	2013-04-17T20:02:42-05:00	Se para todo para reiniciar el sistema	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	667	17 Abr 15:15 Se vuelve a lo normal	ISR		Acquisition system	P Condor	new	2013-04-17T20:00:59-05:00	2013-04-17T20:00:59-05:00	 Se vuelve a lo normal	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	666	17 Abr 15:13 Se cambia entradas de Faraday	ISR		Acquisition system	P Condor	new	2013-04-17T19:59:57-05:00	2013-04-17T19:59:57-05:00	Se cambia entradas de Faraday Rxs desde TRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	665	17 Abr 15:10 Se vuelve a lo normal	ISR		Acquisition system	P Condor	new	2013-04-17T19:58:39-05:00	2013-04-17T19:58:39-05:00	Se vuelve a lo normal Faraday	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	664	17 Abr 15:08 Cambio de entradas	ISR		Acquisition system	P Condor	new	2013-04-17T19:57:34-05:00	2013-04-17T19:57:34-05:00	Cambio de entradas de FARADAY RFA y RFB en panel de Faraday	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	663	17 Abr 15:01 Ajustes de TRs	ISR		Antennas	A. Belleza	new	2013-04-17T19:56:17-05:00	2013-04-17T19:56:17-05:00	Ajustes de TRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	662	17 Abr 14:35 Se para la toma  de datos	ISR		Antennas	P Condor	new	2013-04-17T19:55:24-05:00	2013-04-17T19:55:24-05:00	Se para la toma  de datos para revisar Ues de FARADAY	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	661	17 Abr 14:07 Aumento de ruido Ch A Faraday	ISR		Process/Analysis Program	P Condor	new	2013-04-17T19:54:05-05:00	2013-04-17T19:54:05-05:00	Aumento de ruido Ch A Faraday. Puede ser por chisperos?	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	660	17 Abr 14:01 Ajuste de ATRs	ISR		Antennas	A. Belleza	new	2013-04-17T19:36:54-05:00	2013-04-17T19:36:54-05:00	 Ajuste de ATRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	659	17 Abr 09:56 Ajuste de ATRs	ISR		Antennas	A. Belleza	new	2013-04-17T19:35:59-05:00	2013-04-17T19:35:59-05:00	Ajuste de ATRs	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	658	17 Abr 09:52 Ajuste de TR	ISR		Antennas	A. Belleza	new	2013-04-17T19:34:57-05:00	2013-04-17T19:34:57-05:00	Ajuste de TR	pcondor
Milestone 2013_04 EW_Drift+Faraday+Imaging	657	17 Abr 07:47 Calibración de ATR's y TR´s	ISR		Antennas	W. Rojas	new	2013-04-17T07:50:12-05:00	2013-04-17T07:50:12-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	656	Lectura de Potencia	ISR		Transmitters	Victor Quesada Reyes	new	2013-04-17T07:32:50-05:00	2013-04-17T07:32:50-05:00	"16 de Abril 2013
20:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
21:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
22:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
22:43 Crowbar por caida de voltaje
23:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
17 de Abril 2013
00:00
Tx1 11 Kw
Tx2 7  Kw
Tx3 13 Kw 3930Vac 300 Kw
01:00
Tx1 11 Kw
Tx2 7  Kw
Tx3 13 Kw 3930Vac 300 Kw
02:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
03:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
04:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
05:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
06:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw
07:00
Tx1 12 Kw
Tx2 8  Kw
Tx3 14 Kw 4000Vac 310 Kw"	imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	655	17 Abr 05:49 Calibración de ATR's y TR's	ISR		Antennas	W. Rojas	new	2013-04-17T06:18:47-05:00	2013-04-17T06:18:47-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	654	17 Abr 02:45 Calibración de ATR's  TR's	ISR		Antennas	W. Rojas	new	2013-04-17T02:50:51-05:00	2013-04-17T02:50:51-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	653	17 Abr 00:02 Se detiene adquisición de Imaging	ISR		Acquisition system	I. Manay	new	2013-04-17T00:06:34-05:00	2013-04-17T00:07:14-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	652	16 Abr 23:50 Plot de EW_Drift	ISR		Plot	I. Manay	new	2013-04-16T23:47:40-05:00	2013-04-16T23:47:40-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	651	16 Abr 23:40 Plots de Faraday	ISR		Plot	I. manay	new	2013-04-16T23:38:13-05:00	2013-04-16T23:38:13-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	650	16 Abr 23:14 Calibración de ATR's y TR's	ISR		Antennas	W. Rojas	new	2013-04-16T23:25:16-05:00	2013-04-16T23:25:16-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	649	16 Abr 22:45 Se repone TX	ISR		Transmitters	I. Manay	new	2013-04-16T23:03:56-05:00	2013-04-16T23:03:56-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	648	16 Abr 22:43 Caída de TX	ISR		Transmitters	I. Manay	new	2013-04-16T23:03:21-05:00	2013-04-16T23:03:21-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	647	16 Abr 20:18 Calibración de ATR´s y TR´s	ISR		Antennas	W. Rojas	new	2013-04-16T23:01:18-05:00	2013-04-16T23:01:18-05:00		imanay
Milestone 2013_04 EW_Drift+Faraday+Imaging	646	13 Abr 02:59 Se reinicia PC-ARES (EW_Drift)	ISR+Imaging		Acquisition system		new	2013-04-16T15:42:07-05:00	2013-04-16T15:42:07-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	645	13 Abr 02:36 Problemas de conexión a internet	ISR+Imaging		Process/Analysis Program		new	2013-04-16T15:38:03-05:00	2013-04-16T15:38:03-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	644	13 Abr 02:21 Calibración de los ATRs y TRs	ISR+Imaging		Spark Gaps		new	2013-04-16T15:35:27-05:00	2013-04-16T15:35:27-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	643	13 Abr 00:10 Se ejecuta el programa de procesamiento de EW_Drift	ISR+Imaging		Process/Analysis Program		new	2013-04-16T15:30:04-05:00	2013-04-16T15:30:04-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	642	13 Abr 00:00 Se detiene programa de procesamiento de EW_Drift	ISR+Imaging		Process/Analysis Program	dsuarez	new	2013-04-16T14:15:50-05:00	2013-04-16T14:15:50-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	641	12 Abr 22:59 Calibración de ATRs y TRs	ISR+Imaging		Spark Gaps		new	2013-04-16T14:00:56-05:00	2013-04-16T14:00:56-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	640	12 Abr 19:56 Calibración de los ATRs y TRs	ISR+Imaging		Spark Gaps		new	2013-04-16T13:58:09-05:00	2013-04-16T14:00:05-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	639	12 Abr 18:18 Se prende transmisores	ISR+Imaging		Transmitters		new	2013-04-16T13:56:54-05:00	2013-04-16T13:59:19-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	638	12 Abr 18:14 Se apagó transmisores	ISR+Imaging		Transmitters		new	2013-04-16T13:56:07-05:00	2013-04-16T13:58:58-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	637	12 Abr 17:00 Inicio de experimento ISR+Imaging	ISR+Imaging		Start experiment		new	2013-04-16T13:54:31-05:00	2013-04-16T13:54:31-05:00		dsuarez
Milestone 2013_04 EW_Drift+Faraday+Imaging	636	11 Abr 22.00 FIN DE TURNO	ISR+Imaging		End experiment		new	2013-04-16T13:53:03-05:00	2013-04-16T13:53:03-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	635	11 Abr 20:05 Calibración de los TRs y ATRs	ISR+Imaging		Spark Gaps	J. Lavado	new	2013-04-16T13:51:27-05:00	2013-04-16T13:51:27-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	634	11 Abr 18:58 Se prende transmisores	ISR+Imaging		Acquisition system	R. Abad	new	2013-04-16T13:49:35-05:00	2013-04-16T13:49:35-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	633	11 Abr 18:56 Se apagó transmisores	ISR+Imaging		Transmitters	R. Abad	new	2013-04-16T13:48:21-05:00	2013-04-16T13:48:21-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	632	11 Abr 18:33 Se reinicia la adquisición de datos, EW_Drift (PC ARES)	ISR+Imaging		Acquisition system	R. Abad	new	2013-04-16T13:47:01-05:00	2013-04-16T13:47:01-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	631	11 Abr 18:30 Se cuelga la adquisición PC ARES (EW_Drift)	ISR+Imaging		Acquisition system	R. Abad	new	2013-04-16T13:45:57-05:00	2013-04-16T13:45:57-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	630	11 Abr 18:00 Se prende TXs	ISR+Imaging		Transmitters		new	2013-04-16T13:39:13-05:00	2013-04-16T13:39:13-05:00		rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	629	11 Abr 17:55 Problemas  en TXs	ISR+Imaging		Transmitters	R. Abad	new	2013-04-16T13:37:20-05:00	2013-04-16T13:37:20-05:00	Se cae transmisores.	rabad
Milestone 2013_04 EW_Drift+Faraday+Imaging	628	11 Abr 17:09 Inicio del experimento ISR+Imaging	ISR+Imaging	Others	Start experiment	R. Abad	new	2013-04-16T13:35:31-05:00	2013-04-16T13:35:31-05:00	Se inicia experimento ISR(EW_Drift+Faraday)+Imaging.	rabad
Milestone 2013_03 HYBRID 2 mode	573	13 Mar 15:00 FIN de experimento HYBRID-2	ISR		End experiment	Rita Abad	new	2013-03-13T16:27:56-05:00	2013-03-13T16:27:56-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	572	13 Mar 10:19 Calibraci'on de los ATRs y TRs	ISR		Spark Gaps	Rita Abad	new	2013-03-13T11:08:01-05:00	2013-03-13T11:08:01-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	571	12 Mar 17:01 Calibraci'on de los ATRs y TRs	ISR		Spark Gaps	P Condor	new	2013-03-13T11:06:52-05:00	2013-03-13T11:06:52-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	570	12 Mar 11:51 Calibraci'on de ATRs y TRs	ISR		Spark Gaps	P Condor	new	2013-03-13T11:06:05-05:00	2013-03-13T11:06:05-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	569	07 Mar 20:10 Problemas transmisores	ISR		Transmitters	Daniel Suarez	new	2013-03-13T10:59:57-05:00	2013-03-13T10:59:57-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	568	07 Mar 18:55 Se reinicia adquisici'on	ISR		Acquisition system	Daniel Suarez	new	2013-03-13T10:59:20-05:00	2013-03-13T10:59:20-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	567	07 Mar 18:49 Se cuelga PC ARES	ISR		Acquisition system	Daniel Suarez	new	2013-03-13T10:57:47-05:00	2013-03-13T10:57:47-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	566	07 Mar 18:28 Se reinicia adquisici'on	ISR		Acquisition system	Daniel Suarez	new	2013-03-13T10:54:11-05:00	2013-03-13T10:54:11-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	565	07 Mar 18:24 Se cuelga PC ARES	ISR		Acquisition system	Rita Abad	new	2013-03-13T10:53:31-05:00	2013-03-13T10:53:31-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	564	07 Mar 18:00 Se reinicia adquisici'on	ISR		Acquisition system	Daniel Suarez	new	2013-03-13T10:52:27-05:00	2013-03-13T10:52:27-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	563	07 Mar 17:57 Se cuelga PC ARES	ISR		Acquisition system	Daniel Suarez	new	2013-03-13T10:50:08-05:00	2013-03-13T10:50:08-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	562	07 Mar 16:00 Calibraci'on de chisperos ATRs y TRs	ISR		Spark Gaps	Rita Abad	new	2013-03-13T10:49:18-05:00	2013-03-13T10:49:18-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	561	07 Mar 12:08 Calibraci'on chisperos ATRs y TRs	ISR		Spark Gaps	Rita Abad	new	2013-03-13T10:46:47-05:00	2013-03-13T10:46:47-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	560	07 Mar 09:39 Se reinicia adquisici'on PC ARES	ISR		Acquisition system	Rita Abad	new	2013-03-13T10:43:16-05:00	2013-03-13T10:43:16-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	559	07 Mar 09:34 Se cuelga PC ARES	ISR		Acquisition system	Rita Abad	new	2013-03-13T10:42:34-05:00	2013-03-13T10:42:34-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	558	07 Mar 08:36 Calibraci'on ATRs y TRs	ISR		Spark Gaps	Rita Abad	new	2013-03-13T10:32:47-05:00	2013-03-13T10:32:47-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	557	11 Mar 17:38 Calibraci'on de los ATRs y TRs	ISR		Spark Gaps	Rita Abad	new	2013-03-13T10:24:51-05:00	2013-03-13T10:24:51-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	556	11 Mar 16:55  Se detiene procesamiento	ISR		Process/Analysis Program	Rita Abad	new	2013-03-13T10:12:37-05:00	2013-03-13T10:12:37-05:00	- Usuario local solicita detener procesamiento por cinco minutos.	rabad
Milestone 2013_03 HYBRID 2 mode	555	11 Mar 13:42 Calibraci'on de los ATRs y TRs	ISR		Spark Gaps	Rita Abad	new	2013-03-13T09:36:19-05:00	2013-03-13T09:36:19-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	554	11 Mar 12:28 Se soluciona problemas en transmisores	ISR		Transmitters	Rita Abad	new	2013-03-13T09:35:19-05:00	2013-03-13T09:35:19-05:00	- Sale transmisores	rabad
Milestone 2013_03 HYBRID 2 mode	553	11 Mar 12:20 Problemas Transmisores	ISR		Transmitters	Rita Abad	new	2013-03-13T09:32:13-05:00	2013-03-13T09:32:13-05:00	- No se transmite.	rabad
Milestone 2013_03 HYBRID 2 mode	552	11 Mar 09:36 Se reinicia adquisicion	ISR		Acquisition system	Rita Abad	new	2013-03-13T09:27:27-05:00	2013-03-13T09:27:27-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	551	11 Mar 09:31 Se reinicia PC ARES	ISR		Acquisition system	Rita Abad	new	2013-03-13T09:24:43-05:00	2013-03-13T09:24:43-05:00	- Se cuelga PC ARES aparentemente por mover datos mientras estaba adquiriendo.	rabad
Milestone 2013_03 HYBRID 2 mode	550	11 Mar 09:17 Se detiene monitoreo	ISR		Process/Analysis Program	Rita Abad	new	2013-03-13T09:22:22-05:00	2013-03-13T10:34:10-05:00	- Usuario local detiene procesamiento para mover datos de PC ARES.	rabad
Milestone 2013_03 HYBRID 2 mode	549	11 Mar 09:12 Se soluciona problemas en Transmisores	ISR		Transmitters	Rita Abad	new	2013-03-13T09:17:57-05:00	2013-03-13T09:17:57-05:00	- Sale transmisores, y se soluciona problema de picos en alta tension.	rabad
Milestone 2013_03 HYBRID 2 mode	548	11 Mar 09:00 Problemas Transmisores	ISR		Transmitters	Rita Abad	new	2013-03-13T09:14:19-05:00	2013-03-13T09:14:19-05:00	- No sale transmisores por problemas con picos en alta tension.	rabad
Milestone 2013_03 HYBRID 2 mode	547	11 Mar 08:50 Se inicia experimento HYBRID 2	ISR		Start experiment	Rita Abad	new	2013-03-13T09:08:31-05:00	2013-03-13T09:08:31-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	546	13 Mar 00:00 Figuras de procesamiento	ISR		Plot	I. Manay	new	2013-03-13T04:06:08-05:00	2013-03-13T04:06:08-05:00		imanay
Milestone 2013_03 HYBRID 2 mode	545	13 Mar 03:01 Calibración de ATR's y TR's	ISR		Spark Gaps	A. Coronado	new	2013-03-13T03:15:55-05:00	2013-03-13T03:15:55-05:00		imanay
Milestone 2013_03 HYBRID 2 mode	544	12 Mar 22:12 Calibración de ATR's y TR's	ISR		Spark Gaps	A. Coronado	new	2013-03-12T22:52:24-05:00	2013-03-12T22:52:24-05:00		imanay
Milestone 2013_03 HYBRID 2 mode	543	12 Mar 00:00 Figuras de Procesamiento	ISR		Process/Analysis Program	P Condor	new	2013-03-12T07:34:09-05:00	2013-03-12T07:38:30-05:00	Se coloca las figuras de Rti, noise, profile de power y parametros.	pcondor
Milestone 2013_03 HYBRID 2 mode	542	12 Mar 06:23 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-12T07:32:23-05:00	2013-03-12T07:32:23-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 HYBRID 2 mode	541	12 Mar 03:36 Se colgo la PC ARES	ISR		Acquisition system	P Condor	new	2013-03-12T07:31:39-05:00	2013-03-12T07:31:39-05:00	Se reinicia ARES despues de que se colgo. Volviendo ejecutar el programa Hybrido2.bat.	pcondor
Milestone 2013_03 HYBRID 2 mode	540	12 Mar 01:52 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-12T07:29:46-05:00	2013-03-12T07:29:46-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 HYBRID 2 mode	539	12 Mar 00:26 Caida de Transmisor	ISR		Transmitters	P Condor	new	2013-03-12T07:28:42-05:00	2013-03-12T07:28:42-05:00	 Caida de Transmisor	pcondor
Milestone 2013_03 HYBRID 2 mode	538	12 Mar 00:22 Caida de Transmisor	ISR		Transmitters	P Condor	new	2013-03-12T07:27:16-05:00	2013-03-12T07:27:16-05:00	Caida de Transmisor	pcondor
Milestone 2013_03 HYBRID 2 mode	537	11 Mar 21:44 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-12T07:25:54-05:00	2013-03-12T07:25:54-05:00	 Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 HYBRID 2 mode	536	07 Mar 00:00 Figuras	ISR		Process/Analysis Program	P Condor	new	2013-03-07T07:20:34-05:00	2013-03-07T07:20:34-05:00	Figuras de power, RTi, noise y parametros	pcondor
Milestone 2013_03 HYBRID 2 mode	535	07 Mar 03:02 Calibracion de chisperos ATRs y TRs	ISR		Antennas	J Lavado	new	2013-03-07T07:16:06-05:00	2013-03-07T07:16:06-05:00	Calibracion de chisperos ATRs y TRs	pcondor
Milestone 2013_03 HYBRID 2 mode	534	06 Mar 21:30 Calibracion de chisperos ATRs y TRs	ISR		Antennas	J Lavado	new	2013-03-07T07:15:07-05:00	2013-03-07T07:15:07-05:00	Calibracion de chisperos ATRs y TRs	pcondor
Milestone 2013_03 HYBRID 2 mode	533	06 Mar 20:00 Caida de Transmisor	ISR		Transmitters	P Condor	new	2013-03-07T07:13:37-05:00	2013-03-07T07:13:37-05:00	Caida de Transmisor	pcondor
Milestone 2013_03 HYBRID 2 mode	532	06 Mar 16:25 Problemas Transmisores	ISR		Transmitters		new	2013-03-06T17:37:38-05:00	2013-03-06T17:37:38-05:00	- No sale Transmisores por caída de tensión.	rabad
Milestone 2013_03 HYBRID 2 mode	531	06 Mar 16:07 Calibración de TRs	ISR		Spark Gaps		new	2013-03-06T17:36:26-05:00	2013-03-06T17:36:26-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	530	06 Mar 15:00 Se reinicia la PC-ARES	ISR		Acquisition system		new	2013-03-06T17:35:27-05:00	2013-03-06T17:35:27-05:00	"- Se cuelga la PC-ARES.
- Se reinicia PC-ARES y adquisición de datos."	rabad
Milestone 2013_03 HYBRID 2 mode	529	06 Mar 14:24 Se reinicia PC-ARES	ISR		Acquisition system		new	2013-03-06T17:34:01-05:00	2013-03-06T17:34:01-05:00	Se cuelga PC ARES y se reinicia. Luego se reinicia la adquisición de datos.	rabad
Milestone 2013_03 HYBRID 2 mode	528	06 Mar 13:30 Calibración de chisperos	ISR		Spark Gaps		new	2013-03-06T17:32:31-05:00	2013-03-06T17:32:31-05:00		rabad
Milestone 2013_03 HYBRID 2 mode	527	06 Mar 12:15 Prueba con sistema JARS	ISR		Acquisition system		new	2013-03-06T17:30:01-05:00	2013-03-06T17:30:01-05:00	Se apaga el CR de JARS para descartar que este sea o el sistema de adquisición JARS, sin embargo, se corrobora que el JARS origina una interferencia el causa un aparente corrimiento de pulsos en los datos de HYBRID 2 (PC-ARES).	rabad
Milestone 2013_03 HYBRID 2 mode	526	06 Mar 12:10 Se apaga sistema de adquisición JARS	ISR		Acquisition system		new	2013-03-06T17:27:10-05:00	2013-03-06T17:27:10-05:00	Se apaga JARS porque posiblemente cause interferencia en los datos adde HYBRID 2 adquiridos por PC-ARES.	rabad
Milestone 2013_03 HYBRID 2 mode	525	06 Mar 11:54  Se repone RF	ISR		Transmitters		new	2013-03-06T17:25:12-05:00	2013-03-06T17:25:12-05:00	Despues de programar el CR.	rabad
Milestone 2013_03 HYBRID 2 mode	524	06 Mar 11:53 Se reinicia Controlador de Radar	ISR		Acquisition system		new	2013-03-06T17:23:56-05:00	2013-03-06T17:23:56-05:00	Se quita RF y se reiniciar el Controlador de radar para corregir corrimiento del pulso.	rabad
Milestone 2013_03 HYBRID 2 mode	523	06 Mar 11:48 Se reinicia adquisición	ISR		Acquisition system		new	2013-03-06T17:19:52-05:00	2013-03-06T17:19:52-05:00	- Se reinicia la adquisición en PC-ARES para corregir corrimiento del pulso.	rabad
Milestone 2013_03 HYBRID 2 mode	522	06 Mar 10:51 Cambios en la etapa de recepción (Pre-amplificadores)	ISR		Reception		new	2013-03-06T17:17:10-05:00	2013-03-06T17:17:10-05:00	"-Se aumenta un pre-amplificador de 16dB de ganancia a cada uno de los canales CHA y CHB.
      
   CHA-> 2 Pre-Amp + Att(8dB)+ 1 Pre-Amp + 1 Pre-Amp
   CHB-> 2 Pre-Amp + Att(4dB)+ 1 Pre-Amp + 1 Pre-Amp
   CHC-> Att(30dB)+Att(8dB) "	rabad
Milestone 2013_03 HYBRID 2 mode	521	06 Mar 10:15  Sistema de recepción	ISR		Reception		new	2013-03-06T17:10:10-05:00	2013-03-12T15:29:45-05:00	- Se divide la señal de la antena con splitters, para adquirir en paralelo con el sistema JARS.	Rita Abad
Milestone 2013_03 HYBRID 2 mode	520	06 Mar 10:00   Inicio del experimento HYBRID 2	ISR		Start experiment	Rita Abad	new	2013-03-06T15:36:12-05:00	2013-03-06T15:36:12-05:00	"Se corrigieron varios problemas presentado:

1.- Controlador de Radar no generaba adecuadamente los pulsos de la configuración del *.racp. Se resolvio cambiando de CR.

2.- Diferencia en el nivel de ruido entre los canales A y B (apróx. 15dB). Se resolvio cambiando de Transmisor.
"	rabad
Milestone 2013_03 DriftHighAltitude	627	21 Mar 12:20 FIN de experimento DriftHighAltitude	ISR		End experiment	Rita Abad	new	2013-03-25T12:07:48-05:00	2013-03-25T12:07:48-05:00		rabad
Milestone 2013_03 DriftHighAltitude	626	21 Mar 10:50 Problemas transmisores	ISR		Spark Gaps	R Yaya	new	2013-03-21T12:14:51-05:00	2013-03-21T12:14:51-05:00	Cae screen PA1.	rabad
Milestone 2013_03 DriftHighAltitude	625	21 Mar 11:40 Calibraci'on de los ATR's	ISR		Spark Gaps	W Rojas	new	2013-03-21T12:10:52-05:00	2013-03-21T12:10:52-05:00		rabad
Milestone 2013_03 DriftHighAltitude	624	21 Mar 09:51 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	W Rojas	new	2013-03-21T12:10:04-05:00	2013-03-21T12:10:04-05:00		rabad
Milestone 2013_03 DriftHighAltitude	623	21 Mar 08:25 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	W Rojas	new	2013-03-21T12:09:11-05:00	2013-03-21T12:09:11-05:00		rabad
Milestone 2013_03 DriftHighAltitude	622	21 Mar 07:24 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-21T07:36:45-05:00	2013-03-21T07:36:45-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 DriftHighAltitude	621	21 Mar 03:38 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-21T07:06:54-05:00	2013-03-21T07:06:54-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 DriftHighAltitude	620	21 Mar 01:30 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-21T07:06:20-05:00	2013-03-21T07:06:20-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 DriftHighAltitude	619	21 Mar 00:00 Figuras de Procesamiento	ISR		Process/Analysis Program	P Condor	new	2013-03-21T07:04:16-05:00	2013-03-21T07:04:16-05:00	Se pone las figuras de RTi, espectro y el promedio y los drifts del dia 20 de marzo 2013	pcondor
Milestone 2013_03 DriftHighAltitude	618	20 Mar 23:05 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-21T07:02:17-05:00	2013-03-21T07:07:42-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 DriftHighAltitude	617	20 Mar 21:30 Calibracion de ATRs y TRs	ISR		Antennas	A. Coronado	new	2013-03-21T07:01:27-05:00	2013-03-21T07:01:27-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2013_03 DriftHighAltitude	616	Lecturas de Potencia Txs	ISR		Transmitters	Victor Quesada Reyes	new	2013-03-20T19:16:39-05:00	2013-03-20T19:16:39-05:00	"08:00
Tx 1 39 Kw 
Tx 2 38 Kw, 4050 VAC, 350 Kw
09:00
Tx 1 34 Kw 
Tx 2 32 Kw, 3880 VAC, 320 Kw
10:00
Tx 1 34 Kw 
Tx 2 32 Kw
11:00
Tx 1 33 Kw 
Tx 2 31 Kw, 3850 VAC, 310 Kw
12:00
Tx 1 38 Kw 
Tx 2 36 Kw, 4000 VAC, 350 Kw
13:00
Tx 1 37 Kw 
Tx 2 35 Kw
14:00
Tx 1 37 Kw 
Tx 2 35 Kw
15:00
Tx 1 33 Kw 
Tx 2 30 Kw, 3850 VAC, 320 Kw
16:00
Tx 1 33 Kw 
Tx 2 36 Kw
17:00
Tx 1 33 Kw 
Tx 2 36 Kw
18:00
Tx 1 38 Kw 
Tx 2 36 Kw, 4000 VAC, 330 Kw
19:00
Tx 1 34 Kw 
Tx 2 33 Kw"	rtadeo
Milestone 2013_03 DriftHighAltitude	615	20 Mar 18:48 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	J Lavado	new	2013-03-20T19:01:55-05:00	2013-03-20T19:01:55-05:00		rabad
Milestone 2013_03 DriftHighAltitude	614	20 Mar 17:47 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	J Lavado	new	2013-03-20T19:01:21-05:00	2013-03-20T19:01:21-05:00		rabad
Milestone 2013_03 DriftHighAltitude	613	20 Mar 16:23 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	J Lavado	new	2013-03-20T19:00:41-05:00	2013-03-20T19:00:41-05:00		rabad
Milestone 2013_03 DriftHighAltitude	612	20 Mar 14:50 Calibraci'on de TR's	ISR		Spark Gaps	J Lavado	new	2013-03-20T15:31:32-05:00	2013-03-20T15:31:32-05:00		rabad
Milestone 2013_03 DriftHighAltitude	611	20 Mar 14:03 Calibraci'on de chisperos de RXs	ISR		Spark Gaps	J Lavado	new	2013-03-20T15:30:49-05:00	2013-03-20T15:30:49-05:00		rabad
Milestone 2013_03 DriftHighAltitude	610	20 Mar 11;12 Calibraci'on ATR's y TR's	ISR		Spark Gaps	Rita Abad	new	2013-03-20T15:30:01-05:00	2013-03-20T15:30:01-05:00		rabad
Milestone 2013_03 DriftHighAltitude	609	20 Mar 08:34 Se reinicia la adquisici'on de datos	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:47:07-05:00	2013-03-20T09:47:07-05:00		rabad
Milestone 2013_03 DriftHighAltitude	608	20 Mar 08:32 Se reinicia la PC ARES	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:46:40-05:00	2013-03-20T09:46:40-05:00		rabad
Milestone 2013_03 DriftHighAltitude	607	20 Mar 08:30 Se colg'o PC ARES	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:46:05-05:00	2013-03-20T09:46:05-05:00		rabad
Milestone 2013_03 DriftHighAltitude	606	19 Mar 19:00 Problemas con programaci'on en PC ARES	ISR		Acquisition system	P Condor	new	2013-03-20T09:40:25-05:00	2013-03-20T09:40:25-05:00	Problemas con el programa de adquisici'on de PC ARES.	rabad
Milestone 2013_03 DriftHighAltitude	605	19 Mar 18:16 Se reinicia adquisici'on	ISR		Acquisition system	P Condor	new	2013-03-20T09:38:44-05:00	2013-03-20T09:38:44-05:00	Se cuelga PC ARES.	rabad
Milestone 2013_03 DriftHighAltitude	604	19 Mar 18:04 Se reinicia adquisici'on	ISR		Acquisition system	P Condor	new	2013-03-20T09:37:37-05:00	2013-03-20T09:37:37-05:00	Se cuelga PC ARES	rabad
Milestone 2013_03 DriftHighAltitude	603	19 Mar 17:50 Se inicia transmisi'on	ISR		General	P Condor	new	2013-03-20T09:36:31-05:00	2013-03-20T09:36:31-05:00		rabad
Milestone 2013_03 DriftHighAltitude	602	19 Mar 17:45 Reinicio de adquisici'on de datos	ISR		Acquisition system	P Condor	new	2013-03-20T09:35:19-05:00	2013-03-20T09:35:19-05:00	Se reinicia la adquisici'on datos, luego de solucionar los problemas electricos.                 	rabad
Milestone 2013_03 DriftHighAltitude	601	19 Mar 17:39 Corte de flu'ido el'ectrico	ISR		Acquisition system	P Condor	new	2013-03-20T09:19:58-05:00	2013-03-20T09:19:58-05:00	Problemas con las conexiones electricas en el laboratorio de Operaciones.	rabad
Milestone 2013_03 DriftHighAltitude	600	19 Mar 16:48 Calibraci'on de ATR's y TR's	ISR		Spark Gaps	Rita Abad	new	2013-03-20T09:18:18-05:00	2013-03-20T09:18:18-05:00		rabad
Milestone 2013_03 DriftHighAltitude	599	19 Mar 16:04 Se reinicia sistema de adquisici'on	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:17:31-05:00	2013-03-20T09:17:31-05:00	Se reinicia la adquisici'on de datos.	rabad
Milestone 2013_03 DriftHighAltitude	598	19 Mar 15:56 Problemas con la energ'ia electrica del sistema de adquisici'on	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:16:15-05:00	2013-03-20T09:16:15-05:00	Problemas con la instalaci'on electrica en el laboratorio de operaciones, por tal motivo el sistema de adquisici'on se queda sin energ'ia. 	rabad
Milestone 2013_03 DriftHighAltitude	597	19 Mar 15:07 Se reinicio adquisici'on	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:13:23-05:00	2013-03-20T09:13:23-05:00	"-Se colgo PC ARES
- Se reinicio PC y luego la adquisici'on"	rabad
Milestone 2013_03 DriftHighAltitude	596	19 Mar 14:30 Se aumento potencia, Transmisores.	ISR		Transmitters	Rita Abad	new	2013-03-20T09:12:22-05:00	2013-03-20T09:12:22-05:00	"Se aumento de potencia.
Se cambia de transmisor, inicialmente estaba saliendo ATRAD1 (TX1) y ATRAD2 (TX2), luego del cambio se esta saliendo con ATRAD3 (TX1) y ATRAD2 (TX2)."	rabad
Milestone 2013_03 DriftHighAltitude	595	19 Mar 14:25 Se reinicia adquisici'on	ISR		Acquisition system	Rita Abad	new	2013-03-20T09:07:19-05:00	2013-03-20T09:07:19-05:00	Se cuelga PC ARES	rabad
Milestone 2013_03 DriftHighAltitude	594	19 Mar 14:00 Problemas en transmisores	ISR		Transmitters	Rita Abad	new	2013-03-20T09:03:32-05:00	2013-03-20T09:03:32-05:00		rabad
Milestone 2013_03 DriftHighAltitude	593	19 Mar 12:20 Problemas transmisores	ISR		Transmitters	Rita Abad	new	2013-03-20T09:02:25-05:00	2013-03-20T09:02:25-05:00		rabad
Milestone 2013_03 DriftHighAltitude	592	19 Mar 12:15 Problemas transmisores	ISR		Transmitters	Rita Abad	new	2013-03-20T08:59:10-05:00	2013-03-20T08:59:10-05:00		rabad
Milestone 2013_03 DriftHighAltitude	591	19 Mar 12:01 Se reinicia adquisici'on	ISR		Acquisition system	Rita Abad	new	2013-03-20T08:58:36-05:00	2013-03-20T08:58:36-05:00	"- Se colgo PC ARES.
- Se reinicia PC ARES y adquisici'on."	rabad
Milestone 2013_03 DriftHighAltitude	590	19 Mar 11:50 Calibraci'on de ATR's y TRS	ISR		Spark Gaps	Rita Abad	new	2013-03-20T08:56:08-05:00	2013-03-20T08:56:08-05:00		rabad
Milestone 2013_03 DriftHighAltitude	589	19 Mar 09:13 Los canales A y B son colocados en su posici'on original	ISR		Acquisition system	Rita Abad	new	2013-03-20T08:51:59-05:00	2013-03-20T08:51:59-05:00	Los canales A y B se devuelven a su posici'on original y se continua con la adquisici'on.	rabad
Milestone 2013_03 DriftHighAltitude	588	19 Mar 09:11 Se intercambian los canales A y B (en recepci'on)	ISR		Reception	Rita Abad	new	2013-03-20T08:43:38-05:00	2013-03-20T08:43:38-05:00	Se intercambian los canales A y B provenientes de la antena, en la Jaula de Faraday, para descartar problemas que se visualizan en el procesamiento.	rabad
Milestone 2013_03 DriftHighAltitude	587	20 Mar 07:08 Calibración de ATR's y TR's	ISR		Spark Gaps	W. Rojas	new	2013-03-20T07:10:02-05:00	2013-03-20T07:10:02-05:00		imanay
Milestone 2013_03 DriftHighAltitude	586	20 Mar 05:20 Calibración de ATR's y TR's	ISR		Spark Gaps	W. Rojas	new	2013-03-20T05:22:29-05:00	2013-03-20T05:22:29-05:00		imanay
Milestone 2013_03 DriftHighAltitude	585	20 Mar 03:45 Falla del Driver Nro2	ISR	Others	Transmitters	rtadeo	new	2013-03-20T04:21:17-05:00	2013-03-20T04:46:37-05:00		rtadeo
Milestone 2013_03 DriftHighAltitude	584	20 Mar 02:11 Calibración de ATR's y TR's	ISR		Spark Gaps	W. Rojas	new	2013-03-20T02:45:47-05:00	2013-03-20T02:45:47-05:00		imanay
Milestone 2013_03 DriftHighAltitude	583	20 Mar 00:17 Calibración de ATR's y TR's	ISR		Spark Gaps	W. Rojas	new	2013-03-20T02:45:04-05:00	2013-03-20T02:45:04-05:00		imanay
Milestone 2013_03 DriftHighAltitude	582	20 Mar 00:00 Figuras de Procesamiento	ISR		Plot	I. Manay	new	2013-03-20T00:04:24-05:00	2013-03-20T00:04:24-05:00		imanay
Milestone 2013_03 DriftHighAltitude	581	19 Mar 21:27 Falla en Modulo de antena	ISR	Others	Transmitters	rtadeo	new	2013-03-19T22:51:45-05:00	2013-03-19T22:51:45-05:00		rtadeo
Milestone 2013_03 DriftHighAltitude	580	19 Mar 20:54 Falla Fuente Screen PA1	ISR	Others	Transmitters		new	2013-03-19T22:50:27-05:00	2013-03-19T22:50:27-05:00		rtadeo
Milestone 2013_03 DriftHighAltitude	579	19 Mar 20:30 Falla Fuente Screen PA1	ISR	Others	Transmitters	rtadeo	new	2013-03-19T22:48:34-05:00	2013-03-19T22:48:34-05:00		rtadeo
Milestone 2013_03 DriftHighAltitude	578	19 Mar 21:29 Se repuso Tx	ISR		Antennas	I. Manay	new	2013-03-19T21:49:53-05:00	2013-03-19T21:49:53-05:00	Ya no se observaba arco.	imanay
Milestone 2013_03 DriftHighAltitude	577	19 Mar 21:27 Se apagó Tx	ISR		Antennas	I. Manay	new	2013-03-19T21:48:29-05:00	2013-03-19T21:48:29-05:00	Se apagó Tx para corregir chispa en uno de los módulos del cuarto Sur. Había un corto circuito entra la malla y la línea.	imanay
Milestone 2013_03 DriftHighAltitude	576	19 Mar 20:50 Calibración de los ATR's y TR's	ISR		Spark Gaps	I. Manay	new	2013-03-19T21:44:55-05:00	2013-03-19T21:45:40-05:00		imanay
Milestone 2013_03 DriftHighAltitude	575	19 Mar 20:12 Se reinicia la toma de datos con sistema ARES	ISR		Acquisition system	I. Manay	new	2013-03-19T21:43:03-05:00	2013-03-19T21:43:03-05:00	El archivo de configuración del sistema de adquisición estaba seteado para adquirir de 8am a 7pm. Se hizo el cambio para que adquiera de forma continua.	imanay
Milestone 2013_03 DriftHighAltitude	574	19 Mar 08:25 Inicio del experimento DriftHighAltitude	ISR		Start experiment	Rita Abad	new	2013-03-19T10:44:47-05:00	2013-03-19T10:44:47-05:00	"- Se  inicia el experimento, siendo el sistema de adquisición la Echotek y PC ARES.
- El sistema esta sincronizado con la Digisonda."	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	727	23 Abr 14:00 Ya esta los datos en Madrigal	ISR		Process/Analysis Program	P Condor	new	2013-04-23T14:57:24-05:00	2013-04-23T14:57:24-05:00	Ya esta los datos en Madrigal desde marzo.	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	519	14 Dic 15:20 Fin de la toma de datos	ISR		End experiment	ryanque	new	2012-12-22T11:57:10-05:00	2012-12-22T11:57:10-05:00	Se finaliza la toma de datos ISCOD Diciembre 11-14 2012	ryanque
Milestone 2012_12 ISCOD Campaign Dec 11-14	508	20 Dec 10:48   Datos de EW_Drift+Faraday en PUMA	ISR		General	Rita Abad	new	2012-12-20T10:56:09-05:00	2012-12-20T10:56:09-05:00	- Los datos de la campaña EW_Drift+FARADAY Dec(11-14), ya fueron subidos al PUMA. 	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	507	14 Dic 15:04 Finaliza el turno	ISR		End experiment		new	2012-12-14T15:13:09-05:00	2013-08-17T21:29:28-05:00	Se adjunta los graficos del presente dia	dsuarez
Milestone 2012_12 ISCOD Campaign Dec 11-14	506	14 Dic 15:05 Lectura de Potencias	ISR	Others	Transmitters	rtadeo	new	2012-12-14T15:08:23-05:00	2012-12-14T15:08:23-05:00	"Fin de Toma de Datos
Lista de Lesctura de potencias de los TX1,TX2,TX3."	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	505	14 Dic 14:47 se inicia nuevamente la adquisicion	ISR		Acquisition system		new	2012-12-14T14:52:01-05:00	2013-08-17T21:31:06-05:00		dsuarez
Milestone 2012_12 ISCOD Campaign Dec 11-14	504	14 Dic 14:40 Se Cuelga PC-Ares	ISR		Acquisition system		new	2012-12-14T14:50:29-05:00	2013-08-17T21:30:25-05:00		dsuarez
Milestone 2012_12 ISCOD Campaign Dec 11-14	503	14 Dic 12:18 Falla de Fuente Scree PA1	ISR	Others	Transmitters	rtadeo	new	2012-12-14T12:18:39-05:00	2012-12-14T12:18:39-05:00		rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	502	14 Dic 09:55 Calibracion de chisperos ATRs-TRs	ISR		Spark Gaps		new	2012-12-14T10:08:22-05:00	2013-08-17T21:33:36-05:00		dsuarez
Milestone 2012_12 ISCOD Campaign Dec 11-14	501	14 Dic 07:40 Falla de alto voltaje (Crowbar)	ISR	Others	Transmitters	rtadeo	new	2012-12-14T09:01:49-05:00	2012-12-14T09:01:49-05:00	Causado por variacion tension en la linea de AC	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	500	14 Dic 07:40 Caen transmisores	ISR		Break Experiment	D.Cordova	new	2012-12-14T07:44:16-05:00	2012-12-14T07:44:16-05:00	Caen transmisores y vuelven a encenderse a las 7:43am	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	499	14 Dic 07:26 Pierde datos PC ARES  EWDrifts	ISR		Break Experiment		new	2012-12-14T07:32:30-05:00	2012-12-14T07:32:30-05:00	Comienza a perde datos PC AARES, se reinicia adquisicion a las 7:28 y dejo de perder datos	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	498	14 Dic 07:07 Graficos de los datos del experimento	ISR		Plot	dcordova	assigned	2012-12-14T07:09:04-05:00	2012-12-14T07:13:21-05:00		dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	497	14 Dic 07:10 Lectura de Potencia	ISR		Transmitters		new	2012-12-14T07:02:27-05:00	2012-12-22T11:53:57-05:00	"20:00
TX   Pow. Inc
1      7  KW
2      11 KW
3      22 KW
21:00
TX   Pow. Inc
1      7  KW
2      11 KW
3      22 KW
23:00
TX   Pow. Inc
1      7  KW
2      11 KW
3      22 KW
00:00
TX   Pow. Inc
1      7  KW
2      11 KW
3      22 KW
01:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW
02:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW
03:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW
04:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW
05:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW
06:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW
07:00
TX   Pow. Inc
1      6  KW
2      11 KW
3      21 KW"	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	496	14 Dic 04:47 Pierde datos PC Faraday	ISR		Start experiment	D.Cordova	new	2012-12-14T05:36:34-05:00	2012-12-14T05:36:34-05:00	La PC que se utiliza en FARADAY pierde datos, luego reinicia automaticamente la adquisicion.	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	495	14 Dec 04:31 Calibracion de ATR-s	ISR		Start experiment	A. Belleza	new	2012-12-14T05:34:01-05:00	2012-12-14T05:34:01-05:00		dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	494	14 Dic 04:15 Variacion de la fase de la CCF	ISR		Start experiment	dcordova	assigned	2012-12-14T05:32:41-05:00	2012-12-14T05:32:58-05:00	Se observa que la fase de la CCF de A y B varia de 0 a +/-180, luego del pase de HYDRA la fase de la CCF vuelve a ceero	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	493	14 Dic 04:14 Pase de HYDR A	ISR		Physical Phenomena		new	2012-12-14T05:30:19-05:00	2012-12-14T05:30:19-05:00	Se observa el pase de Hydra en los canales A y B; en los canales C y D, se observo 30 minutos antes aproximadamente.	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	492	14 Dic 02:55 Comienza a formarse la curva Ne	ISR		Physical Phenomena		new	2012-12-14T05:27:17-05:00	2012-12-14T05:27:17-05:00		dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	491	14 Dic 01:25 Calibracion de chisperos	ISR		Spark Gaps	A. Belleza	assigned	2012-12-14T02:02:33-05:00	2012-12-14T04:57:13-05:00	Se observa un incremento de ruido durante algunos minutos	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	490	14 Dic 01:11 Se reinicia el experimento	ISR		Start experiment	dcordova	assigned	2012-12-14T01:26:01-05:00	2012-12-14T01:31:30-05:00	Se reinicia el experimento 	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	489	14 Dic 01:05 Se cuelga la CP ARES	ISR		Break Experiment	dcordova	assigned	2012-12-14T01:24:45-05:00	2012-12-14T01:33:03-05:00	Se congela PC ARES, se reinicia esta; tambien se detiene experimento Faraday y detiene la transmision	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	488	13 Dic 23:58 Graficos del dia 13 de diciembre	ISR		Acquisition system	dcordova	assigned	2012-12-13T23:54:41-05:00	2012-12-14T00:15:56-05:00		dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	487	13 Dic 22:28 Disminucion en la tension de linea	ISR		Transmitters	V. Quesada	assigned	2012-12-13T23:04:17-05:00	2012-12-14T06:50:34-05:00	Disminuye la tension de linea durante un par de minutos	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	486	13 Dic 22:18 Calibracion de chisperos	ISR		Start experiment	A. Belleza	assigned	2012-12-13T23:02:50-05:00	2012-12-14T04:57:49-05:00	Se vuelve a ajustar los chisperos, se observa que disminuye la coherencia a 0.2 @ 800Km	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	485	13 Dic 22:20 Decremento en la coherencia @ 800km	ISR		Start experiment	dcordova	assigned	2012-12-13T23:01:19-05:00	2012-12-13T23:09:35-05:00	"22:20 La coherencia dismuye a 0.25
"	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	484	13 Dic 22:08 Incremento en la coherencia @ 800km	ISR		Start experiment	dcordova	assigned	2012-12-13T22:59:27-05:00	2012-12-13T23:09:49-05:00	Se observa el incremento de la coherencia @ 800Km a 0.4	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	483	13 Dic 21:45 Incremento de ruido por calibracion de chispero	ISR		Start experiment	dcordova	assigned	2012-12-13T22:08:31-05:00	2012-12-13T23:09:59-05:00	La calibracion de los chisperos de las 21:43 tambien genero un aumento en el nivel de ruido, lo cual se puede observar en el rti de Drifts; luego de la rectificacion en la calibracion, los niveles de ruido se reestablecieron	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	482	13 Dic 21:43 Calibracion de chisperos	ISR		Start experiment	A. Belleza	assigned	2012-12-13T21:54:02-05:00	2012-12-14T04:58:09-05:00	Se calibran los chisperos de los TR y ATR, se observo que aumento la diferencia de ruido entre los canales A y B (0.8dB), luego de unos minutos la diferencia disminuyo a 0.6dB	dcordova
Milestone 2012_12 ISCOD Campaign Dec 11-14	481	13 Dec 19:58 Resumen potencias e incidencias TX	ISR		Transmitters		new	2012-12-13T20:00:39-05:00	2012-12-13T20:00:39-05:00	Adjunto resumen de incidencias y potencias registradas en el transmisor	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	480	13 Dec 19:10 Calibración de TRs y ATRs	ISR		Spark Gaps	Walter Rojas	new	2012-12-13T19:55:50-05:00	2012-12-13T19:55:50-05:00	Ajuste de chisperos.	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	479	13 Dec 18:21 Se cuelga PC ARES - EW_DRIFT	ISR		Acquisition system	Rita Abad	new	2012-12-13T19:50:32-05:00	2012-12-13T19:59:27-05:00	"Se cuelga PC ARES.

18:22 Se reinicia PC y programa de procesamiento."	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	478	13 Dec 16:51 Calibración de TRs	ISR		Spark Gaps	Jose Lavado	new	2012-12-13T16:54:02-05:00	2012-12-13T16:54:02-05:00	Calibración solo de TRs. 	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	477	13 Dec 15:30 Se desincroniza data FARADAY	ISR		Acquisition system	Rita Abad	new	2012-12-13T16:01:28-05:00	2012-12-13T16:01:28-05:00	Se reinicia adquisición y procesamiento de datos de FARADAY. 	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	476	13 Dec 13:40 Calibración de TRs y ATRs	ISR		Spark Gaps	Jose lavado	new	2012-12-13T15:41:38-05:00	2012-12-13T15:58:52-05:00	Ajuste de chisperos	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	475	13 Dec 13:20 Se reinicia PC de procesamiento	ISR		Process/Analysis Program	Rita Abad	new	2012-12-13T15:23:16-05:00	2012-12-13T19:58:24-05:00	"Debido a que los programas de EW_Drift y Faraday se detuvieron, se reinicio la PC de procesamiento y todos sus programas.
La adquisición no se detuvo en ningún momento."	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	474	13 Dec 11:20 Desincronización de data FARADAY	ISR		Acquisition system	Rita Abad	new	2012-12-13T12:03:52-05:00	2012-12-13T12:12:19-05:00	Se desincroniza el envio de la data FARADAY y se reinicia a las 11:21 adquisición en PC RADAR.	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	473	13 Dec 08:35 Falsa alarma de TX1	ISR		Transmitters	Rommel Yaya	new	2012-12-13T12:01:28-05:00	2012-12-13T12:11:43-05:00	Se deja de transmitir por falsa alarma del TX1.	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	472	13 Dec 10:45 Falla interlock local	ISR		Transmitters		new	2012-12-13T10:52:26-05:00	2012-12-13T10:52:26-05:00	Falsa alarma en interlock local de PA 1 deshabilita transmisión. Se corrige error y se habilita transmisión. 	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	471	13 Dec 08:34 Falla interlock local	ISR		Transmitters		new	2012-12-13T09:17:04-05:00	2012-12-13T09:17:04-05:00	Falla fuente de SCREEN PA1 por falsa alarma en interlock local, se corrige falla y se habilita transmisión.	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	470	13 Dic 07:30 Se logra subir potencia	ISR		Transmitters	P. Condor	new	2012-12-13T07:42:43-05:00	2012-12-13T07:42:43-05:00	Se logra subir un poco mas de potencia lo que estaba bajando. Se sigue chequeando transmisores	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	469	13 Dic 06:40 Falla del PA1	ISR	Others	Transmitters	rtadeo	new	2012-12-13T07:42:13-05:00	2012-12-13T07:42:13-05:00	Se Baja la potencia del Pa1	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	466	13 Dic 07:08 Ajustes de ATRs y TRs	ISR		Antennas	A. Belleza	new	2012-12-13T07:40:10-05:00	2012-12-13T07:40:10-05:00	Ajustes de ATRs y TRs	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	465	13 Dic 07:02 Se apaga transmisor	ISR		Transmitters	P. Condor	new	2012-12-13T07:39:12-05:00	2012-12-13T09:31:47-05:00	"Se apaga transmisor para arreglar y ver porque hay baja potencia.
Se prendio a las 7:10 am."	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	464	13 Dic 06:50 Figuras del 12-12-2012	ISR		Process/Analysis Program	P. Condor	new	2012-12-13T07:29:45-05:00	2012-12-13T09:33:39-05:00	Figuras de rtis, espectros y resultados de EW_drifts y Faraday del 12-12-2012	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	463	13 Dic 06:36 Se colgo ARES	ISR		Process/Analysis Program	P Condor	new	2012-12-13T07:23:26-05:00	2012-12-13T07:23:26-05:00	"Se colgo la PC ARES. Se reseteo y volvio ejecutar el batch de EW_Drifts.
"	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	462	13 Dic 04:15 Calibracion ATRs	ISR		Antennas	A. Belleza	new	2012-12-13T07:22:06-05:00	2012-12-13T07:22:06-05:00	Calibracion ATrs	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	461	13 Dic 01:31 Calibracion de ATRs	ISR		Antennas	A. Belleza	new	2012-12-13T03:27:00-05:00	2012-12-13T03:27:00-05:00	Calibracion de ATRs	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	460	13 Dic 00:22 Se vuelve a correr FARADAY	ISR		Acquisition system	P Condor	new	2012-12-13T03:22:42-05:00	2012-12-13T03:22:42-05:00	Se vuelve a correr la adquisicion de FARADAY, despues que los graficos se pararon a 23;30 pero seguia tomando datos. Y a 00:18 se desincronizo.	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	459	12 Dic 23:22 Caida de transmisor Falla Crowbar	ISR		Transmitters	P Condor	new	2012-12-13T03:20:11-05:00	2012-12-13T09:29:55-05:00	Caida del transmisor, se levanta sin problema 23:24.	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	458	12 Dic 19:59 Se apaga TX debido a chispeo en antena Cuarto Oeste	ISR		Transmitters	P Condor	new	2012-12-13T03:18:21-05:00	2012-12-13T09:21:09-05:00	"Se apaga el TX para corregir el chispeo en el cuarto oeste de la antena.
A las 08:06 se vuelve a prender el TX"	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	457	12 Dic 20:05 Calibracion de ATRs y TRs	ISR		Antennas	P Condor	new	2012-12-13T03:16:25-05:00	2012-12-13T03:16:25-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	456	12 Dic 19:59 Chispas en malla antena Cuarto Oeste Modulo 13	ISR		Antennas	P Condor	new	2012-12-13T03:13:18-05:00	2012-12-13T09:03:17-05:00	"Se apaga el transmisor para revisar las chispas en la malla de la antena. Se corrige este problema.
La malla del cuarto Oeste Modulo 13 se había pegado a la linea de TX de la antena."	pcondor
Milestone 2012_12 ISCOD Campaign Dec 11-14	454	12 Dec 18:37 Calibracion de ATR-s y TR-s	ISR		Start experiment		new	2012-12-12T19:38:50-05:00	2012-12-12T19:38:50-05:00		minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	453	12 Dec 15:17 Calibracion de ATR-s y TR-s	ISR		Start experiment		new	2012-12-12T19:38:35-05:00	2012-12-12T19:38:35-05:00		minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	452	12 Dec 12:02 Calibracion de ATR-s y TR-s	ISR		Start experiment		new	2012-12-12T19:38:20-05:00	2012-12-12T19:38:20-05:00		minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	451	12 Dec 19:20 Resumen de incidencias y potencias TX	ISR		Transmitters		new	2012-12-12T19:21:17-05:00	2012-12-12T19:21:17-05:00	Adjunto resumen de incidencias, potencias del transmisor e información de tensión de línea.	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	450	12 Dec 14:05 Cambio repentino de potencia en Canales A, B y C EW Drift	ISR		Process/Analysis Program		new	2012-12-12T14:17:53-05:00	2012-12-12T14:17:53-05:00	A pesar que se revisó chisperos y no hay paso de la Galaxia, Hydra, Sol ni de la Luna	minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	449	12 Dec 13:40 Cambio repentino de potencia en Canales A, B y C EW Drift	ISR		Process/Analysis Program		new	2012-12-12T14:17:18-05:00	2012-12-12T14:17:18-05:00	A pesar que se revisó chisperos y no hay paso de la Galaxia, Hydra, Sol ni de la Luna	minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	448	12 Dec 11:50 Cambio repentino de potencia en Canales A, B y C EW Drift	ISR		Process/Analysis Program		new	2012-12-12T14:16:12-05:00	2012-12-12T14:16:12-05:00	A pesar que se revisó chisperos y no hay paso de la Galaxia, Hydra, Sol ni de la Luna	minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	447	12 Dec 10:58 Renaudación de programa de procesamiento EW_Drift	ISR		Process/Analysis Program		new	2012-12-12T13:27:45-05:00	2012-12-12T13:27:45-05:00		minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	446	12 Dec 10:40 Detencion de programa de procesamiento EW_Drift	ISR		Process/Analysis Program		new	2012-12-12T13:26:01-05:00	2012-12-12T13:26:01-05:00	El programa de procesamiento se detuvo de manera repentina, pero la adquisicion continuó de manera normal	minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	444	12 Dec 09:10 Calibracion de ATR-s y TR-s	ISR		General		new	2012-12-12T09:51:34-05:00	2012-12-12T09:51:34-05:00	Incremento repentino de ruido en los canales A  y B	minonan
Milestone 2012_12 ISCOD Campaign Dec 11-14	443	12 Dec 09:30 Falla fuente SCREEN PA1	ISR		Transmitters		new	2012-12-12T09:43:48-05:00	2012-12-12T09:43:48-05:00	Falla fuente SCREEN PA 1 des habilitando permiso de RF por unos instantes.	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	442	12 Dec 07:43 Reinicio de adquisicion en PC radar (Faraday)	ISR		Acquisition system	Ivan Manay	new	2012-12-12T07:48:55-05:00	2012-12-12T07:48:55-05:00	Los datos estaban desincronizados.	imanay
Milestone 2012_12 ISCOD Campaign Dec 11-14	441	12 Dec 07:04 Calibracion de ATR-s y TR-s	ISR		Spark Gaps	Americo Coronado	new	2012-12-12T07:17:54-05:00	2012-12-12T07:17:54-05:00		imanay
Milestone 2012_12 ISCOD Campaign Dec 11-14	440	12 Dic 07:00 Transmisores-Potencia	ISR	Others	Transmitters	rtadeo	new	2012-12-12T07:02:38-05:00	2012-12-12T07:02:38-05:00		rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	439	12 Dic 05:49  Caida de Transmisores	ISR	Others	Transmitters	rtadeo	new	2012-12-12T05:52:36-05:00	2012-12-12T05:52:36-05:00	Falla Screen PA1 causado por variacion en la linea de AC	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	438	12 Dic 05:45  Caida de Transmisores	ISR	Others	Transmitters	rtadeo	new	2012-12-12T05:50:41-05:00	2012-12-12T05:50:41-05:00	Falla de la fuente screen PA 1	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	437	12 Dec 03:38 Calibracion de ATR-s y TR-s	ISR		Spark Gaps	Americo Coronado	new	2012-12-12T04:04:51-05:00	2012-12-12T04:04:51-05:00		imanay
Milestone 2012_12 ISCOD Campaign Dec 11-14	436	12 Dic 00:00  Caida de Transmisores	ISR	Others	Transmitters	rtadeo	new	2012-12-12T01:09:10-05:00	2012-12-12T01:09:10-05:00	Falla fuente screen PA1	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	435	12 Dec 00:10 Calibración de ATR's y TR's	ISR		Spark Gaps	Americo Coronado	new	2012-12-12T00:19:41-05:00	2012-12-12T00:19:41-05:00		imanay
Milestone 2012_12 ISCOD Campaign Dec 11-14	434	12 Dec 00:05 Graficos dia 346 (11 Dec)	ISR		Plot	Ivan Manay	new	2012-12-12T00:08:55-05:00	2012-12-12T00:12:05-05:00		imanay
Milestone 2012_12 ISCOD Campaign Dec 11-14	433	11 Dic 22:38 Caida de Transmisores (Crowbar)	ISR	Others	Transmitters	rtadeo	new	2012-12-11T22:42:24-05:00	2012-12-11T22:42:24-05:00	Causado por variacion en la linea AC	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	432	11 Dic 21:25 Caida de Transmisores (Crowbar)	ISR	Others	Transmitters	rtadeo	new	2012-12-11T22:08:36-05:00	2012-12-11T22:21:49-05:00	Causado por variacion en la linea de AC	rtadeo
Milestone 2012_12 ISCOD Campaign Dec 11-14	431	11 Dec 20:35 Calibración de los ATR's y TR's	ISR		Spark Gaps	Americo Coronado	new	2012-12-11T20:57:35-05:00	2012-12-11T20:57:35-05:00		imanay
Milestone 2012_12 ISCOD Campaign Dec 11-14	430	11 Dec 19:40 Reporte de incidencias del transmisor y resumen de potencias	ISR		Transmitters		new	2012-12-11T19:42:49-05:00	2012-12-11T19:42:49-05:00	Adjunto resumen de incidencias e información adicional de los transmisores	ryaya
Milestone 2012_12 ISCOD Campaign Dec 11-14	429	11 Dec 19:10  Calibración de TR's y ATR's	ISR		Spark Gaps	Walter Rojas	new	2012-12-11T19:42:08-05:00	2012-12-11T19:42:08-05:00	Ajuste de chisperos	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	428	11 Dec 17:15  Calibración de TR's y ATR's	ISR		Spark Gaps	Walter Rojas	new	2012-12-11T19:41:25-05:00	2012-12-11T19:41:25-05:00	Ajuste de chisperos	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	427	11 Dec 14:10 Caída de Fuente de alta tensión Transmisor	ISR		Transmitters	Rommel Yaya	new	2012-12-11T14:20:41-05:00	2012-12-11T14:20:41-05:00	Caída de fuente de alta tensión de 20 KW - Transmisores	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	426	11 Dec 13:59  Calibración de TR's y ATR's	ISR		Spark Gaps	Walter Rojas	new	2012-12-11T14:12:19-05:00	2012-12-11T14:12:19-05:00	Se realiza ajuste de chisperos.	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	425	11 Dec 10:53  Calibración de TR's y ATR's	ISR		Spark Gaps		new	2012-12-11T14:07:05-05:00	2012-12-11T14:09:09-05:00	Se realizó el ajuste a los chisperos.	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	424	11 Dec 08:23-10:57 Altura máxima de datos	ISR		Start experiment		new	2012-12-11T11:14:04-05:00	2012-12-11T14:04:43-05:00	- La altura máxima de datos es de 400 km es la máxima potencia donde llega el transmisor.	rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	423	11 Dec 09:05 Caída de Transmisor	ISR		Transmitters	Rita Abad	new	2012-12-11T10:41:21-05:00	2012-12-11T10:41:21-05:00		rabad
Milestone 2012_12 ISCOD Campaign Dec 11-14	422	11 Dec 08:23 Inicio de experimento EW_Drift+Faraday	ISR		Start experiment		new	2012-12-11T09:19:49-05:00	2012-12-22T11:15:44-05:00	"El turno empezo a las 8:23 am.
Debido a problemas en la movilidad llegó a las 7:40 am se empezo tarde. El Jefe de Area de Operaciones ya esta informado."	ryanque
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	728	23 Abr 14:00 Ya esta los datos en Madrigal	ISR		Process/Analysis Program	P Condor	new	2013-04-23T14:58:31-05:00	2013-04-23T14:58:31-05:00	Ya esta los datos en Madrigal desde Febrero.	pcondor
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	518	21 Dic 23:14 Derrame en la resistencia descarga Banco de Condensadores	ISR		Transmitters	ryanque	new	2012-12-22T09:32:57-05:00	2012-12-22T09:33:37-05:00	"Hay un derrame en aceite de la resistencia de descarga del TX 3.
El turno se finaliza"	ryanque
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	517	19 Dec  22:05 FIN de experimento EW_Drift+Faraday+Imaging	ISR		End experiment	Rita Abad	new	2012-12-20T16:24:56-05:00	2012-12-20T16:24:56-05:00	Se finaliza el experimento EW_Drift+Faraday+Imaging con los sistemas de adquisición Echotek-PC-ARES, Echotek-PC-RADAR y JARS.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	516	19 Dec 19:28 Atenuación de 1 dB (canal D - EW_Drift )	ISR		Reception	Rita Abad	new	2012-12-20T14:35:29-05:00	2012-12-20T14:35:29-05:00	Se atenua 1 dB al canad D de EW_Drift.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	515	19 Dec 19:16 Calibración de TRs	ISR		Spark Gaps	Alejandro Belleza	new	2012-12-20T14:31:21-05:00	2012-12-20T14:31:21-05:00	Ajuste de chisperos en todos los TRs	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	514	19 Dec 18:47 Revisión de conexiones	ISR		Reception	Rita Abad	new	2012-12-20T14:28:17-05:00	2012-12-20T14:28:17-05:00	Se revisaron las conexiones de recepción en la Jaula de Faraday debido a problemas en el nivel de ruido del experimento EW_Drift. Sin embargo, las variaciones del nivel de ruido continuan.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	513	19 Dec 18:10 Configurando Beacon en Exp. Imaging	ISR		General	Rita Abad	new	2012-12-20T14:17:38-05:00	2012-12-20T14:17:38-05:00	Debido al cambio de configuración y que el Controlador de Radar JARS tuvo problemas en la configuración ocasiono interferencia en el experimento EW_Drift.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	512	19 Dec 17:55 Calibración de TRs	ISR		Spark Gaps	Alejandro Belleza	new	2012-12-20T11:14:23-05:00	2012-12-20T11:14:23-05:00	Ajuste de chisperos en todos los TRs.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	511	19 Dec 17:48 Calibración ATR 4	ISR		Spark Gaps	Alejandro Belleza	new	2012-12-20T11:12:59-05:00	2012-12-20T11:12:59-05:00	Ajuste de chisperos en ATR4.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	510	19 Dec 17:38  Se reinicia PC ARES (EW_Drift)	ISR		Acquisition system	Rita Abad	new	2012-12-20T11:10:47-05:00	2012-12-20T11:10:47-05:00	Se cuelga la PC ARES y se reinicia.	rabad
Milestone 2012_12 EW_Drift + Faraday + Imaging Dec 18 - 21	509	19 Dec 17:33  Inicio de Exp.  EW_Drift+Faraday+Imaging	ISR		Start experiment	Rita Abad	new	2012-12-20T10:59:39-05:00	2012-12-20T10:59:39-05:00	"Se inicia la toma de datos para el experimento EW_Drift+Faraday+Imaging.

"	rabad
Milestone 2012_09 ISCOD Campaign Sep 04-07	421	07 Nov 15:00 Se sube datos a Madrigal	ISR		Process/Analysis Program	P Condor	new	2012-11-08T14:08:24-05:00	2012-11-08T14:08:57-05:00	Se sube los datos de EW_Drifts a Madrigal de los dias 04-07 de setiembre.	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	417	11 Sep 15:00 Finalizado de copiado de datos a PUMA	ISR		End experiment		new	2012-10-11T08:28:54-05:00	2012-10-11T08:28:54-05:00	Todos los datos del turnos ISCOD Sep 2012 estan en PUMA ...	ryanque
Milestone 2012_09 ISCOD Campaign Sep 04-07	416	07 Sep 15:10 Finaliza el turno	ISR		End experiment		new	2012-10-10T10:47:54-05:00	2012-10-10T10:47:54-05:00	El turno finalizó a las 15:10	ryanque
Milestone 2012_09 ISCOD Campaign Sep 04-07	415	03:48 Ajuste de TRs y ATRs	ISR		Antennas	A Belleza	new	2012-09-07T05:41:49-05:00	2012-10-03T12:04:35-05:00	Ajuste de TRs y ATRs	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	414	00:20 Se arregla Transmisor de Faraday	ISR		Transmitters	P Condor	new	2012-09-07T05:41:00-05:00	2012-10-03T12:05:00-05:00	Se arregla Transmisor de Faraday	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	413	00:10 07 Set 2012 Caida del transmisor para revisar el de FARADAY	ISR		Transmitters	P Condor	new	2012-09-07T05:40:14-05:00	2012-10-03T12:05:18-05:00	Caida del transmisor para revisar el de FARADAY	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	412	Plots del 06 set 2012	ISR		Process/Analysis Program	P Condor	new	2012-09-07T05:29:10-05:00	2012-10-03T12:05:42-05:00	Figuras de rtis y resultados EW_Drifts y Faraday	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	411	22:52 Ajuste de ATrs y TRs	ISR		Antennas	A Belleza	new	2012-09-07T05:19:00-05:00	2012-10-03T12:05:59-05:00	Ajuste de ATrs y TRs	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	410	20:03 Perdio Sincronismo EW_Drifts	ISR		Acquisition system	P Condor	new	2012-09-07T05:17:34-05:00	2012-10-03T12:06:32-05:00	Perdio Sincronismo EW_Drifts	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	409	17:00 Calibracion de ATrs y Trs	ISR		Antennas	J Lavado	new	2012-09-07T05:16:23-05:00	2012-10-03T12:06:54-05:00	Calibracion de ATrs y Trs	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	408	15:45 Caida de Transmisor	ISR		Transmitters	D Suarez	new	2012-09-07T05:15:07-05:00	2012-10-03T12:07:16-05:00	Caida de Transmisor	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	407	10:40 Calibracion de ATRs y TRs	ISR		Antennas	J Lavado	new	2012-09-07T05:13:53-05:00	2012-10-03T12:07:31-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	406	08:41 06 set 2012 Perdio Sincronismo	ISR		Acquisition system	R Abad	new	2012-09-07T04:57:27-05:00	2012-10-03T12:07:55-05:00	Perdio Sincronismo la adquisicion de FARADAY	pcondor
Milestone 2012_09 ISCOD Campaign Sep 04-07	405	Problema con el GPS time server	ISR	JRO Staff	General	Luis Condori	new	2012-09-06T08:31:59-05:00	2012-10-03T12:08:15-05:00	El dia 5 de Setiembre, alrededor de las 08:00AM se encontro que el GPS que controla el tiempo en el servidor habia perdido sincronismo, no detectaba satelites, dano valores incoherentes al software del servidor de tiempo, se reseteo el GPS y el programa del servicio de tiempo, y se reajusto el tiempo en las computadoras de adquisicion.	lcondori
Milestone 2012_09 ISCOD Campaign Sep 04-07	404	05:30 Ajuste ATR's y TR's	ISR		Spark Gaps	Walter Alvarado	new	2012-09-06T05:34:14-05:00	2012-10-03T12:08:34-05:00		imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	403	03:17 Se reinicia adquisición de PC radar	ISR		Acquisition system	Iván Manay	new	2012-09-06T03:21:40-05:00	2012-10-03T12:08:48-05:00	Datos no sincrónicos	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	402	03:11 Se reinicia adquisición de PC Radar	ISR		Acquisition system	Iván Manay	new	2012-09-06T03:20:56-05:00	2012-10-03T12:09:16-05:00	Datos en PC radar estaban desincronizados.	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	401	03:01 Se reinicia toma de datos en PC Ares: Experimento EW_Drift	ISR		Acquisition system	Iván Manay	new	2012-09-06T03:15:03-05:00	2012-10-03T12:09:33-05:00		imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	400	02:59 Se cuelga PC Ares	ISR		Acquisition system	Iván Manay	new	2012-09-06T03:09:12-05:00	2012-10-03T12:09:52-05:00	Se reinicia PC Ares	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	399	00:24 Se calibró chisperos ATR's y TR's	ISR		Start experiment	Walter Alvarado	new	2012-09-06T01:22:28-05:00	2012-10-03T12:10:09-05:00		imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	398	00:22 Se reinicia la adquisición en PC radar	ISR		Acquisition system	Iván Manay	new	2012-09-06T01:21:38-05:00	2012-10-03T12:10:28-05:00	No habia sincronía en los datos	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	397	00:10 Se cuelga PC Ares	ISR		Acquisition system	Iván Manay	new	2012-09-06T01:20:17-05:00	2012-10-03T12:10:50-05:00	La PC Ares se colgó dos veces: 00:10 y 00:23	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	396	05-09-12 23:59 Reinicio de toma de datos	ISR		Acquisition system	Iván Manay	new	2012-09-06T01:17:10-05:00	2012-10-03T12:11:10-05:00	Se reinicia la toma de datos de EW_Drift	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	395	05/09/12 23:22 Problemas con PC Ares	ISR		Acquisition system	Iván Manay	new	2012-09-06T01:14:48-05:00	2012-10-03T12:11:26-05:00	PC Ares se cuelga. Se reinicia PC. Se reinicia la adquisición, pero este genereba un mensaje de error de no poder configurar a la echotek. El problema era que cada vez que se reiniciaba la PC, se ejecuta el programa de adquisición de otro experimento. Se solucionó temporalmente cancelando dicho programa en el task manager.	imanay
Milestone 2012_09 ISCOD Campaign Sep 04-07	394	Sucesos de la noche del 4 de Setiembre	ISR		Process/Analysis Program		new	2012-09-05T05:31:54-05:00	2012-10-03T12:11:39-05:00	"20:05 Problema con la adquisision de la PC Drifts, se reinicio el programa
20:15 Problema con la adquisision de la PC Drifts, se reinicio el programa

21:32 Calibracion de chisperos

01:28 Calibracion de chisperos"	dcordova
Milestone 2012_09 ISCOD Campaign Sep 04-07	393	10:24 INICIO de Exp. EW_Drift + Faraday	ISR	Others	Start experiment	Rita Abad	new	2012-09-04T11:49:00-05:00	2012-10-03T12:11:54-05:00	- Se inicia la toma de datos del experimento EW_Drift + Faraday.	rabad
Milestone 2012_09 ISCOD Campaign Sep 04-07	392	07:00 Inicio del test de EW_Drift+Faraday	ISR	Others	General	Rita Abad	new	2012-09-04T11:41:38-05:00	2012-10-03T12:12:13-05:00	"- Se adquiere con los sistemas de adquisición: 1 Echotek + PC Radar y 3 Echotek + PC ARES.
-Se cambia el DDS de FARADAY porque no originaba el FLIP.
"	rabad
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	420	22 Oct 16:30 Subida de datos a Madrigal	ISR		Process/Analysis Program	P Condor	new	2012-10-22T16:45:19-05:00	2012-10-22T16:45:19-05:00	Se sube los datos procesados de EW_Drifts del 16 al 18 de julio a Madrigal.	pcondor
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	391	Lectura de Potencias Txs	ISR	JRO Staff	Transmitters		new	2012-07-17T07:02:09-05:00	2012-07-17T07:02:09-05:00	"16 de Julio del 2012
21:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
22:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
23:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
17 del Julio del 2012
00:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
01:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
02:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
03:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
04:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
05:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW
06:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 K W
3 16.5V 22 KW
07:00 TX Potencia
1 16.5V 6 KW
2 16.6V 10 KW 
3 16.5V 22 KW"	vquesada
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	390	06:20 Ajuste de ATR's y TR's	ISR	JRO Staff	Spark Gaps	Alejandro Belleza	new	2012-07-17T06:25:51-05:00	2012-07-17T06:25:51-05:00		imanay
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	389	04:40 Se reiniciaron visores de EW_Drift y Faraday en PC de 3 monitores	ISR	JRO Staff	Process/Analysis Program	Iván Manay	new	2012-07-17T05:02:34-05:00	2012-07-17T05:02:34-05:00		imanay
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	388	04:10 Se reinició PC de 3 monitores	ISR	JRO Staff	Process/Analysis Program	Iván Manay	new	2012-07-17T05:00:50-05:00	2012-07-17T05:00:50-05:00	Ya que no se podia abrir IDL para procesar EW_Drift, se intentó cerrarlo desde linea de comnados (Comando kill). Como lo anterior no dio resultados, se cortó el visor de datos de Faraday y se reinició la PC de tres monitores. 	imanay
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	387	03:30 Se colgó visor de datos de EW_Drift	ISR	JRO Staff	Process/Analysis Program	Iván Manay	new	2012-07-17T04:54:56-05:00	2012-07-17T04:54:56-05:00	Se cerró IDL y no se podía volver a abrir. Aparecía mensaje de no poder lanzar la aplicación.	imanay
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	386	Resumen TX	ISR	JRO Staff	Transmitters		new	2012-07-16T20:28:57-05:00	2012-07-16T20:28:57-05:00	"15:10 LV ON
15:20 HV ON
15:42 TX  Potencia
       1     9 KW
       2    12 KW 
       3    20 KW
       Falla fuente 10 KV Driver 1 y Driver 2
16:09 TX  Potencia
       1     6 KW
       2     8 KW 
       3    16 KW
17:17 Falla Screen PA
17:30 Falla fuente 10 KV Driver 1 y Driver 2, se quita thyratron del Driver 2
18:40 TX  Potencia
       1     6 KW
       2     9 KW 
       3    21 KW
19:30 TX  Potencia
       1     7 KW
       2    11 KW 
       3    22 KW
20:20 TX  Potencia
       1     6 KW
       2    11 KW 
       3    22 KW"	ryaya
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	385	Controlador Error	ISR	JRO Staff	General	Luis COndori	new	2012-07-16T20:21:25-05:00	2012-07-16T20:21:25-05:00	Los Pulsos del  controlador de radar del Experimento EW perdieron sincronismo, produjo patron extra~no en los pulsos del TX que involucro malos datos en ambos experimentos.	lcondori
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	384	Plot ESF	ISR	JRO Staff	Process/Analysis Program	Luis Condori	new	2012-07-16T19:47:40-05:00	2012-07-16T19:47:40-05:00	ESF en progreso, primeor lo vieron los anales A y B(desde las 18:30 +/-) y luego los canales C y D y los de Faraday ( despues de las 07:10 +/-).	lcondori
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	383	plots Faraday	ISR	JRO Staff	Plot	Luis Condori	new	2012-07-16T18:13:19-05:00	2012-07-16T18:13:19-05:00	Plots de Parametros y perfiles de potencia del experimento Faraday, KP index tinde a disminuir	lcondori
Milestone 2012_07 EWDrift + Faraday GeoMagnetic Storm Jul 14.	382	Start experiment	ISR	JRO Staff	Start experiment	Luis Condori.	new	2012-07-16T17:51:25-05:00	2012-07-16T17:51:25-05:00	Inicio del experimento 16:55LT (16 de Julio del 2012)	lcondori
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	419	16 Oct 16:40 Subida de datos a Madrigal	ISR		Process/Analysis Program	P Condor	new	2012-10-16T16:43:11-05:00	2012-10-16T16:43:11-05:00	Se subio a Madrigal los datos de Drifts y su promedio para los dias del 12, 13, 14 y 15 de junio del 2012.	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	381	Resumen TX	ISR	JRO Staff	Transmitters		new	2012-06-15T14:55:42-05:00	2012-06-15T14:55:42-05:00	"08:00 
TX 1:    8KW
TX 3:   20KW
08:09 RF OFF 
Cambio de conexión al hibrido de transmisión para el PA1.
09:00 
TX 1:    8KW
TX 3:   19KW
10:00  
TX 1:   10KW
TX 3:   20KW
10:05
CAE FUENTE SCREEN PA1
11:00 
TX 1:    9KW
TX 3:   19KW
12:00
CAE FUENTE SCREEN PA1 
TX 1:   10KW
TX 3:   21KW
13:00 
TX 1:    9KW
TX 3:   19KW
14:00 
TX 1:    8KW
TX 3:   18KW
"	ryaya
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	380	06:25 Ajustes de Atr	ISR	JRO Staff	Antennas	A. Belleza	new	2012-06-15T07:50:03-05:00	2012-06-15T07:50:03-05:00	Ajustes de Atr	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	379	01:00 Falla de transmisor	ISR	JRO Staff	Transmitters	rtadeo	new	2012-06-15T05:50:56-05:00	2012-06-15T05:54:05-05:00	"Se produce una falla del transmisor PA2 ocacionado por fuga de agua(interior)
solo se transmiten los PA1 y PA3"	rtadeo
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	378	03:50 Ajustes de chisperos	ISR	JRO Staff	Antennas	A. Belleza	new	2012-06-15T05:38:35-05:00	2012-06-15T05:38:35-05:00	Ajustes de chisperos	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	377	01:59 Se vuelve a ejecutar batch EW_Drifts	ISR	JRO Staff	Acquisition system	P. Condor	new	2012-06-15T05:37:54-05:00	2012-06-15T05:37:54-05:00	Se vuelve a ejecutar batch EW_Drifts porque se habia desincronizado.	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	376	01:57 Calibracion de Tr	ISR	JRO Staff	Antennas	A. Belleza	new	2012-06-15T05:36:25-05:00	2012-06-15T05:36:25-05:00	Calibracion de Tr	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	375	01:54 Se inicia todo	ISR	JRO Staff	Acquisition system	P.Condor	new	2012-06-15T05:35:45-05:00	2012-06-15T05:35:45-05:00	Se inicia todo de nuevo despues de prender los Tx se ejecuta los programas de adquisicion y procesamiento.	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	374	01:30 Se apaga los transmisores	ISR	JRO Staff	Transmitters	P. Condor	new	2012-06-15T05:34:07-05:00	2012-06-15T05:34:07-05:00	Se apaga los transmisores, para solucionar TX2 que tiene muchas reflejadas y da poca potencia. Despues se descubre que es problema con el PA	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	373	01:00 15 jun 2012 Tx2 tiene muchas reflejadas	ISR	JRO Staff	Transmitters	P. Condor	new	2012-06-15T05:32:16-05:00	2012-06-15T05:32:16-05:00	Tx2 tiene muchas reflejadas se va ver porque	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	372	00:10 Plots del 14 junio 2012	ISR	JRO Staff	Process/Analysis Program	P. Condor	new	2012-06-15T00:11:49-05:00	2012-06-15T00:11:49-05:00	Figuras de rtis, Spectros y resultados del 14-06-12	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	371	21:44 Calibracion de chisperos	ISR	JRO Staff	Antennas	A. Belleza	new	2012-06-14T21:51:32-05:00	2012-06-14T21:51:32-05:00	Calibracion de chisperos	pcondor
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	370	Resumen TX	ISR	JRO Staff	Transmitters		new	2012-06-14T19:41:15-05:00	2012-06-14T19:41:15-05:00	"08:00
TX1    8KW
TX2   12KW
TX3   18KW
09:00
TX1    8KW
TX2   10KW
TX3   18KW
10:00
TX1    8KW
TX2   11KW
TX3   19KW
11:00
TX1    8KW
TX2   11KW
TX3   18KW
12:00
TX1    8KW
TX2   12KW
TX3   20KW
13:00
TX1    8KW
TX2   12KW
TX3   20KW
14:00
TX1    8KW
TX2   11KW
TX3   18KW
15:00
TX1    8KW
TX2   11KW
TX3   18KW
16:00
TX1    8KW
TX2   11KW
TX3   19KW
17:00
TX1    8KW
TX2   11KW
TX3   20KW
18:00
TX1    8KW
TX2   11KW
TX3   18KW
19:00
TX1    8KW
TX2   12KW
TX3   20KW
"	ryaya
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	369	Class-M solar Flare	ISR	JRO Staff	Physical Phenomena	Luis Condori	new	2012-06-14T09:45:04-05:00	2012-06-14T09:45:04-05:00	"Evento de solar flar clase ""M"" detectado por el radar"	lcondori
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	368	Fenomeno detectado por el Radar	ISR	JRO Staff	Physical Phenomena	Luis Condori	new	2012-06-14T09:34:23-05:00	2012-06-14T09:34:23-05:00	Se  vuelve a presentar el mismo fenomeno de los dias anteriores a esta hora (09:30AM LT) se nota fuerte incremento en los canales A y B	lcondori
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	367	Lecturas de Potencia Txs	ISR	JRO Staff	Transmitters		new	2012-06-14T07:12:51-05:00	2012-06-14T07:12:51-05:00	"13 de Junio del 2012
20:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 12Kw
3 16.5V 20Kw
Voltaje de linea: 3980 VAC, 310 Kw
21:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 12Kw
3 16.5V 20 Kw
Voltaje de linea: 3980 VAC, 310 Kw
21:44 Crowbar por caida de tension
22:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 12Kw
3 16.5V 20 Kw
Voltaje de linea: 3980 VAC, 310 Kw
22:37 Crowbar por caida de tension
23:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 3980 VAC, 310 Kw
14 de Junio del 2012
00:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
01:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
02:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
03:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
04:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
04:35 Crowbar por caida de tension
05:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
06:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw
07:00 
Tx Fil Pot
1 16.5V 8 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Voltaje de linea: 2980 VAC, 310 Kw"	vquesada
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	366	06:47 Calibración de chisperos	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-06-14T06:49:13-05:00	2012-06-14T06:49:13-05:00	Calibración de ATR's y TR's	imanay
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	365	04:33 Caída de transmisores	ISR	JRO Staff	Transmitters		new	2012-06-14T04:48:45-05:00	2012-06-14T04:48:45-05:00		imanay
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	364	02:59 Calibración de chisperos	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-06-14T03:01:36-05:00	2012-06-14T03:01:36-05:00	Calibración de ATR's y TR's	imanay
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	363	23:21 Calibración chisperos	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-06-13T23:24:49-05:00	2012-06-13T23:24:49-05:00	Calibración de chisperos ATR's y TR's.	imanay
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	362	22:40 Reinicio manual de ADQ. de PC radar	ISR	JRO Staff	Acquisition system		new	2012-06-13T22:43:23-05:00	2012-06-13T22:43:23-05:00		imanay
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	361	22:38 Reinicio automático de ADQ de PC radar	ISR	JRO Staff	Acquisition system	Iván Manay	new	2012-06-13T22:42:47-05:00	2012-06-13T22:42:47-05:00		imanay
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	360	Resumen TX	ISR	JRO Staff	Transmitters		new	2012-06-13T20:01:46-05:00	2012-06-13T20:01:46-05:00	"15:20
TX1    8KW
TX2   10KW
TX3   18KW
16:00
TX1    8KW
TX2   11KW
TX3   18KW
17:00
TX1    8KW
TX2   10KW
TX3   18KW
18:00
TX1    8KW
TX2   11KW
TX3   18KW
19:00
TX1    8KW
TX2   12KW
TX3   20KW"	ryaya
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	359	Resumen TX	ISR	JRO Staff	General		new	2012-06-13T14:10:57-05:00	2012-06-13T14:10:57-05:00	"08:00 
TX1     9KW
TX2    11KW
TX3    20KW
09:00 
TX1     8KW
TX2    11KW
TX3    19KW
10:00 
TX1     8KW
TX2    10KW
TX3    18KW
11:00 
TX1     8KW
TX2    10KW
TX3    18KW
12:00 
TX1     8KW
TX2    11KW
TX3    20KW
13:00 
TX1     8KW
TX2    11KW
TX3    19KW
14:00 
TX1     8KW
TX2    10KW
TX3    18KW
"	ryaya
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	358	(10:02) Fuente HV	ISR	JRO Staff	Transmitters		new	2012-06-13T10:25:13-05:00	2012-06-13T10:25:13-05:00	Cae fuente 20KV por transitorio, se vuelve a encender y todo funciona normalmente	ryaya
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	357	(07:58) Fuente HV	ISR	JRO Staff	Transmitters		new	2012-06-13T08:09:12-05:00	2012-06-13T08:09:12-05:00	Cae fuente 20KV por transitorio, se vuelve a activar y todo funciona normalmente.	ryaya
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	356	Caen los Transmisores	ISR	JRO Staff	General		new	2012-06-13T07:41:36-05:00	2012-06-13T07:41:36-05:00	7:32 Caen los transmisores grandes, se observo una fluctuacion en la tension de linea, se restablecio la salida de los transmisores	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	355	Imagen de Drift del 13 de Junio a las 7:30am	ISR	JRO Staff	General		new	2012-06-13T07:32:01-05:00	2012-06-13T07:32:01-05:00		dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	354	Lecturas de Potencia Txs	ISR	JRO Staff	General		new	2012-06-13T07:27:30-05:00	2012-06-13T07:27:30-05:00	"12 de Junio del 2012
20:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 22 Kw
Potencia de linea: 4000 VAC, 310 Kw
21:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw
22:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw
23:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw
00:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4030 VAC, 310 Kw
01:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw
02:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4030 VAC, 310 Kw
03:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4030 VAC, 310 Kw
04:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4030 VAC, 310 Kw
05:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw
06:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw
07:00 
Tx Fil Pot
1 16.5V 9 Kw
2 16.5V 13Kw
3 16.5V 21 Kw
Potencia de linea: 4000 VAC, 310 Kw"	vquesada
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	353	02:49  CALIBRACIÓN DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-06-13T02:53:41-05:00	2012-06-13T02:53:41-05:00	Calibración de chisperos ATR's y TR's.	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	352	La PC RADAR pierde sincronismo en la adquisicion	ISR	JRO Staff	General		new	2012-06-13T00:54:38-05:00	2012-06-13T00:54:38-05:00	"00:44 La PC RADAR pierde sincronismo en la adquisiscion, por ello se detuvo y volvio a cargar programa de adquisicion.
Esta desincronizacion se observo en el la potencia de ruido y el calculo de Faraday"	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	351	Obesrvacion de la senial en el RTI	ISR	JRO Staff	General		new	2012-06-13T00:18:45-05:00	2012-06-13T00:18:45-05:00	00:15 El cielo esta tranquilo, no se observa presencia de spread-F en el RTI, se observa incremento del ruido por el paso de la galaxia	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	350	Se detiene programa para calculo de Faraday por cuenta propia	ISR	JRO Staff	General		new	2012-06-13T00:14:08-05:00	2012-06-13T00:14:08-05:00	Con el cambio de dia, se interrumpe de forma inesperada el programa para el calculo de Faraday, se vuelve a reiniciar el programa y continua el procesamiento	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	349	Screenshot del dia 12 de Junio	ISR	JRO Staff	General		new	2012-06-12T23:48:06-05:00	2012-06-12T23:48:06-05:00		dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	348	22:10 CALIBRACIÓN DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-06-12T22:13:38-05:00	2012-06-12T22:15:21-05:00	Calibración de chisperos ATR's y TR's.	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	347	Graficos de Drifts de las 7pm	ISR	JRO Staff	General		new	2012-06-12T20:06:12-05:00	2012-06-12T20:06:12-05:00	"Se detuvo programa de Drifsts a la 7:50, se volvio a correr /users/users/Workspace/IDL_GUI/drifts/Batchs/ew_drifts_12jun2012.pro
Se muestran graficos de Drifts, "	dcordova
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	346	18:00 Calibracion de ATrs y TRs	ISR	JRO Staff	Antennas	J. Lavado	new	2012-06-12T19:47:18-05:00	2012-06-12T19:47:18-05:00	Calibracion de ATrs y TRs	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	345	POTENCIA DEL TX	ISR	JRO Staff	Transmitters	rtadeo	new	2012-06-12T17:29:31-05:00	2012-06-12T17:29:31-05:00	"HORA   TX     Fill     POT(kW)   lINEA
08:10   1      16.5      8       3950VAC 3F
        2      16.5      10       300kW
        3      16.5      18      
10:30   1      16.5      8       3990VAC 3F      
        2      16.5      10
        3      16.5      19
11:00   1      16.5      8
        2      16.5      10
        3      16.5      18
12:03  Falla de HV por variacion en la Linea VAC
13:00   1      16.5      9
        2      16.5      11
        3      16.5      20
14:00   1      16.5      8
        2      16.5      10
        3      16.5      19
15:00   1      16.5      8
        2      16.5      11
        3      16.5      20
16:00   1      16.5      8
        2      16.5      11
        3      16.5      20
17:00   1      16.5      9
        2      16.5      11
        3      16.5      21
    



"	rtadeo
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	344	15:44 Reinicia adquisicion de datos PC RADAR	ISR	JRO Staff	Acquisition system	R. Abad	new	2012-06-12T16:07:16-05:00	2012-06-12T16:07:16-05:00	Pierde sincronismo.	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	343	15:31 Reinicio de adquisicion de datos PC RADAR	ISR	JRO Staff	Acquisition system	R. Abad	new	2012-06-12T16:05:43-05:00	2012-06-12T16:05:43-05:00	Pierde sincronismo	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	342	15:17 Reinicio de adquisicion de datos PC RADAR	ISR	JRO Staff	Acquisition system	R. Abad	new	2012-06-12T16:04:50-05:00	2012-06-12T16:04:50-05:00	Pierde sincronismo	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	341	13:45 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-06-12T16:03:47-05:00	2012-06-12T16:03:47-05:00	Ajuste de chisperos	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	340	12:03 Caida Transmisor	ISR	JRO Staff	Transmitters	Rafael tadeo	new	2012-06-12T16:02:24-05:00	2012-06-12T16:02:24-05:00		rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	339	10:52 calibracion de ATRs y TRs	ISR	JRO Staff	Spark Gaps	J. Lavado	new	2012-06-12T15:37:59-05:00	2012-06-12T15:37:59-05:00	Ajuste de chisperos ATRs y TRs	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	338	08:58 Se cambia atenuador de paso por uno fijo, Canal B EW_Drift	ISR	JRO Staff	Reception	Rita Abad	new	2012-06-12T14:00:16-05:00	2012-06-12T14:00:16-05:00	"-el nivel del ruido del canal B de EW_Drift variaba demasiado, por eso se decidio cambiar el atenuador de paso de la jaula de Faraday por un atenuador fijo de 1dB, en el canal B de EW_Drift. 

-Despues del cambio el nivel del ruido se mantiene mas estable."	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	337	08:33 Calibracion de chisperos ChA y ChB	ISR	JRO Staff	Antennas	J. Lavado	new	2012-06-12T13:46:19-05:00	2012-06-12T13:46:19-05:00	Calibracion de chisperos ChA y ChB	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	336	08:28 Caida de transmisor	ISR	JRO Staff	Transmitters	P Condor	new	2012-06-12T13:44:28-05:00	2012-06-12T13:44:28-05:00	Caida del Transmisor	rabad
Milestone 2012_06 EWDrift + Faraday ISCOD Campaign	335	08:04 Inicio toma de datos	ISR	JRO Staff	General	P. Condor	new	2012-06-12T13:43:20-05:00	2012-06-12T13:43:20-05:00	Inicio del experimento	rabad
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	418	11 Oct 17:30 Subida de datos a Madrigal	ISR		Process/Analysis Program	P Condor	new	2012-10-11T17:35:53-05:00	2012-10-22T17:44:21-05:00	Se sube los datos procesados de EW_Drifts mayo 2012 a Madrigal	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	334	05:53 Calibración ATR's y TR's	ISR	JRO Staff	Spark Gaps	Alejandro Belleza	new	2012-05-25T05:47:48-05:00	2012-05-25T05:47:48-05:00		imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	333	03:02 Reinicio manual de adquisición de PC radar	ISR	JRO Staff	Acquisition system	Iván Manay	new	2012-05-25T03:00:12-05:00	2012-05-25T03:00:12-05:00		imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	332	03:00 Reinicio automático de adquisición de PC radar	ISR	JRO Staff	Acquisition system	Iván Manay	new	2012-05-25T02:59:34-05:00	2012-05-25T02:59:34-05:00		imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	331	02:42 Calibración de ATR's	ISR	JRO Staff	Spark Gaps	Alejandro Belleza	new	2012-05-25T02:37:18-05:00	2012-05-25T02:37:18-05:00		imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	330	01:27 Reinicio manual de la adquisición de PC radar	ISR	JRO Staff	Acquisition system	Iván Manay	new	2012-05-25T01:31:15-05:00	2012-05-25T01:33:39-05:00	Se verificó datos de PC radar y al ver pérdida de sincronía se reinició la adquisición de forma manual.	imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	329	00:57 Reinicio automático de adquisición de PC radar	ISR	JRO Staff	Acquisition system	Iván Manay	new	2012-05-25T01:29:02-05:00	2012-05-25T01:33:14-05:00	La adquisición se reinicio sola.	imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	328	22: 35 Calibración ATR's y TR's	ISR	JRO Staff	Spark Gaps	Alejandro Belleza	new	2012-05-24T22:32:10-05:00	2012-05-24T22:34:18-05:00		imanay
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	327	Lecturas de potencia Txs	ISR	JRO Staff	General		new	2012-05-24T19:05:42-05:00	2012-05-24T19:05:42-05:00	"Resumen de potencia de transmisores:
24 de Junio del 2012
08:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11Kw
3 16.5V 19 Kw
Potencia de linea: 3980 VAC, 300 Kw
09:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 22 Kw
Potencia de linea: 3980 VAC, 300 Kw
10:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 22 Kw
Potencia de linea: 3980 VAC, 300 Kw
11:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 22 Kw
Potencia de linea: 3980 VAC, 300 Kw
12:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 22 Kw
Potencia de linea: 3980 VAC, 300 Kw
13:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 22 Kw
Potencia de linea: 3980 VAC, 300 Kw
14:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 21 Kw
Potencia de linea: 3910 VAC, 300 Kw
15:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 21 Kw
Potencia de linea: 3910 VAC, 300 Kw
15:40 Cae screen PA tx3
16:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 21 Kw
Potencia de linea: 3910 VAC, 300 Kw
17:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 21 Kw
Potencia de linea: 3950 VAC, 300 Kw
18:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 21 Kw
Potencia de linea: 3910 VAC, 300 Kw
19:00 
Tx Fil  Pot
1 16.5V 9 Kw
2 16.5V 11 Kw
3 16.5V 21 Kw
Potencia de linea: 3910 VAC, 300 Kw"	vquesada
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	326	15:37 caida de transmisor	ISR	JRO Staff	Transmitters	Luis COndori	new	2012-05-24T17:31:41-05:00	2012-05-24T17:31:41-05:00	15:37 a 15:42 Transmisores OFF	lcondori
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	325	15:20 Ajuste de chisperos	ISR	JRO Staff	Spark Gaps	Luis Condori	new	2012-05-24T15:15:32-05:00	2012-05-24T15:15:32-05:00	15:19 a 15:22 ajuste general de chisperos.	lcondori
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	324	07:50 Imagenes	ISR	JRO Staff	General		new	2012-05-24T07:45:10-05:00	2012-05-24T07:45:10-05:00	Plots de rtis, espectros power y resultados	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	323	07:42 Caida de transmisor	ISR	JRO Staff	Transmitters	P. Condor	new	2012-05-24T07:40:24-05:00	2012-05-24T07:40:24-05:00	Caida del transmisor	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	322	07:14 Inicio de toma de datos	ISR	JRO Staff	Process/Analysis Program	P. Condor	new	2012-05-24T07:39:00-05:00	2012-05-24T07:39:00-05:00	Se reinicia la toma de datos despues de cambiar el transformador en Tramsmisores.	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	321	06:20 Caida de Transmisor	ISR	JRO Staff	General	P. Condor	new	2012-05-24T07:35:54-05:00	2012-05-24T07:35:54-05:00	Se detiene la toma de datos, Caida del transmisor por problema con un transformador	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	320	CALIBRACION DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-05-24T03:44:29-05:00	2012-05-24T03:44:29-05:00	Calibracion de chisperos ATR's y TR's.	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	319	CALIBRACION DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-05-23T23:15:15-05:00	2012-05-23T23:15:15-05:00	Calibracion  de chisperos ATR's y TR's.	pcondor
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	318	Potencia de Transmisores	ISR	JRO Staff	Transmitters		new	2012-05-23T19:17:38-05:00	2012-05-23T19:17:38-05:00	"Resumen de potencia de transmisores:
23 de Junio del 2012
08:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 3930 VAC, 300 Kw
09:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 3930 VAC, 300 Kw
10:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 3930 VAC, 300 Kw
12:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 3930 VAC, 300 Kw
13:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw

14:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw
15:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw
16:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw
17:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw
18:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw
19:00 
Tx   Fil     Pot
1    16.5V  9 Kw
2    16.5V  13 Kw
3    16.5V  21 Kw
Potencia de linea: 4000 VAC, 310 Kw
19:17 Crowbar por caida de voltaje"	vquesada
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	317	Manual de Operaciones del experimento EW_Drift+Faraday	ISR	Others	General	Rita Abad	new	2012-05-23T15:53:56-05:00	2012-05-23T15:53:56-05:00	Manual de Operaciones para la configuración del experimento EW_Drift+Faraday.	rabad
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	316	13:30 Calibración de chisperos	ISR	Others	Spark Gaps	W. Rojas	new	2012-05-23T15:47:34-05:00	2012-05-23T15:47:34-05:00	- ajuste de ATR´s y TR´s	rabad
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	315	09:17 Calibración de chisperos ATR´s y TR´s	ISR	Others	Spark Gaps	Rita Abad	new	2012-05-23T15:46:06-05:00	2012-05-23T15:46:06-05:00	- Ajuste de chisperos ATR´s y TR´s	rabad
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	314	(07:41) Resumen de estado transmisores	ISR	JRO Staff	Transmitters		new	2012-05-23T07:44:15-05:00	2012-05-23T07:44:15-05:00	"          TX        Potencia(Inc)
21:00     1            8KW
          2           12KW
          3           20KW
22:00     1            8KW
          2           12KW
          3           20KW
23:00     1            8KW
          2           12KW
          3           20KW
00:00     1            8KW
          2           12KW
          3           20KW
01:00     1            8KW
          2           12KW
          3           20KW
02:00     1            9KW
          2           13KW
          3           21KW
03:00     1            8KW
          2           12KW
          3           20KW
04:00     1            8KW
          2           12KW
          3           20KW
05:00     1            8KW
          2           12KW
          3           20KW
06:00     1            8KW
          2           12KW
          3           20KW
06:28    CAE FUENTE SCREEN PA3
07:00     1            9KW
          2           13KW
          3           21KW"	ryaya
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	313	Interferencia en los cuatro canales de EWDrift	ISR	JRO Staff	General		new	2012-05-23T07:11:32-05:00	2012-05-23T07:11:32-05:00	7:00 se observa incremento de ruido de la senial de los 4 canales de EWDrift, la cual no se debe a Hydra o Galaxia: se observo en el switchyard que el sparkgap del TX3 estaba pegado por la escoria, se ajusto de nuevo este y el nivel de ruido se recupero	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	312	CALIBRACION DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-05-23T06:48:33-05:00	2012-05-23T06:48:33-05:00	Calibracion de chisperos ATR's y TR's.	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	311	Baja la senial de ruido en el canal A de EW Drift	ISR	JRO Staff	General		new	2012-05-23T02:42:37-05:00	2012-05-23T02:42:37-05:00	2:40 el ruido del canala A baja a 18dB, esto se debe a que se formo escoria en los chisperos de los TR, se calibro chispero y el ruido se recupero a 33dB	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	310	CALIBRACION DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-05-23T02:22:21-05:00	2012-05-23T02:22:21-05:00	Calibracion de chisperos ATR's y TR's.	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	309	Desincronizacion en los datos de Faraday	ISR	JRO Staff	General		new	2012-05-23T01:52:28-05:00	2012-05-23T01:52:28-05:00	1:45 Se observa que los datos de Faraday se desincronizan, normalmente el bloque de datos comienza con los pulsos de transmision en la altura cero, pero a aprtir de la 1:25 comienza a diferente altura. Se detiene y reinicia la adquisicion en PC radar, se genera correctamente los datos	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	308	CALIBRACION DE CHISPEROS	ISR	JRO Staff	Antennas		new	2012-05-22T22:53:21-05:00	2012-05-22T22:53:21-05:00	Calibracion de chisperos ATR's y TR's.	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	307	Problema con programa para elcalculo de EW-Drift	ISR	JRO Staff	General	dcordova	new	2012-05-22T20:44:20-05:00	2012-05-22T20:44:20-05:00	EL programa ew_drifts_21may2012 genero mensaje de problemas de procesamiento a las 8:35, por ello se volvio a correr a las 8:45	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	306	Problema con programa para elcalculo de EW-Drift	ISR	JRO Staff	General	Darwin	new	2012-05-22T20:43:58-05:00	2012-05-22T20:43:58-05:00	EL programa ew_drifts_21may2012 genero mensaje de problemas de procesamiento a las 8:35, por ello se volvio a correr a las 8:45	dcordova
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	305	15:00 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2012-05-22T14:58:31-05:00	2012-05-22T14:58:31-05:00	"hora     tx      fil      Pot(KW)     Linea AC
15:00     1       16.5      8          3950Vac
          2       16.5      12     
          3       16.5      20"	rtadeo
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	304	Manuales de Procesamiento de datos	ISR	JRO Staff	Process/Analysis Program	Luis Condori	new	2012-05-22T14:55:22-05:00	2012-05-22T14:55:22-05:00	Estos son los manuales para el procesamiento de datos de ambos experimentos	lcondori
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	303	14:30 Lectura de potencia - Tension	ISR	JRO Staff	Transmitters	rtadeo	new	2012-05-22T14:30:18-05:00	2012-05-22T14:32:23-05:00	"hora        TX          Fil       Pot(Kw)   Linea(VAC)  Pot-Linea(KW)
14:30       1           16.5      8            3950  3F    290     
            2           16.5      12            
            3           16.5      20    "	rtadeo
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	302	13:45 Baja de linea de tension AC	ISR	JRO Staff	Transmitters	rtadeo	new	2012-05-22T14:21:28-05:00	2012-05-22T14:21:28-05:00	"Caida de linea de tension, con una variacion de mas de 100VAC
"	rtadeo
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	301	Caida de transmisores	ISR	JRO Staff	Transmitters	Luis Condori	new	2012-05-22T14:04:04-05:00	2012-05-22T14:04:04-05:00	13:45- 14:05(+/-)Debido a una caida abrupta en la linea de alta tension	lcondori
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	300	Tormenta magnetica	ISR	JRO Staff	Process/Analysis Program	Luis Condori	new	2012-05-22T12:13:30-05:00	2012-05-22T12:13:30-05:00	Hay una tormenta magnetica en progreso, detectado por los magnetometros y por el radar(experimento Drift)	lcondori
Milestone 2012_05 EWDrift + Faraday ISCOD Campaign	299	Inicio de Expeprimento	ISR	JRO Staff	Start experiment	Luis Condori	new	2012-05-22T12:10:27-05:00	2012-05-22T12:10:27-05:00	El experimento empezo alrededor de la 08:20AM	lcondori
Milestone 2012_04 Experimento Oblicuo Abril 24-25	298	Anomalia en experimento oblicuo resuelto (reporte)	ISR	JRO Staff	General	Luis Condori	new	2012-04-26T12:01:59-05:00	2012-09-26T10:16:14-05:00	"El dia de ayer 26 de Abril se encontro el niple de conexion de la ""U"", proveniente del sur UP con restoe de material calcinado que no permitia hacer buen contacto en el punto de conexion.

Los sintomas principales son(eran):
- En los datos procesados se veia un bumping en los perfiles de potencia, la estimacion de la densidad era erratica, no habia estimacion de temperaturas, en resumen era notorio que los datos no eran los esperados, estaban contaminados de alguna forma con informacion no natural.

- En el transmisor se veia que en la salida de los transmisores ademas del pulso propio de salida del transmisor se presentaba un cross-talk del otro transmisor con niveles comparables.

Despues de realizar la correccion correspondiente, se volvio a tomar datos(26 abril 2012), con resultados satisfactorios."	lcondori
Milestone 2012_04 Experimento Oblicuo Abril 24-25	297	Cambio de antena a 4.5degrees	ISR	JRO Staff	General	Luis Condori	new	2012-04-25T13:29:29-05:00	2012-10-03T12:01:36-05:00	Despues de ralizar el cambio de antena a la posicion 4.5grados, todoavia se nota la anomalia en los datos, en la densidad faraday se ven los bumps, y no es posible estimar temperaturas.	lcondori
Milestone 2012_04 Experimento Oblicuo Abril 24-25	296	datos anormales en Faraday On-Axis	ISR	JRO Staff	General	Luis Condori	new	2012-04-25T09:23:19-05:00	2012-10-03T12:02:21-05:00	"Los dias 23, 24 y 25 de Abril se programo tomar datos en el modo EW_Drift+Faraday, pero el procesamiento para el experimento Faraday dio extra~nos resultados, habia un ""bump"" que se adicionaba en los perfiles de densidad y no se tenia estimacion de temperaturas.
Se realizo chequeo de las linea de recepcion , antenas, ABS, transmision, etc. y   no se detecto anormalidad aparente.

Par el dia de hoy 25 de Abril, 2012, se ha programado tomar datos por una hora (de 9 a 10 AM) par tenerlo como referencia y luego hacer cambio de antena a la posicion oblicua conocida como 4.5 grados."	lcondori
Milestone 2012_01 ISCOD Campaign Jan 12-23	295	09:00- 09:44 Test del TX3, con pulsos de EW_Drift	ISR	JRO Staff	General	Rita Abad	new	2012-01-23T11:02:03-05:00	2012-10-03T12:13:42-05:00	"Se realiza test al TX3 con los pulsos de EW_Drift y se mantiene la configuración y antena del experimento EW_DRIFT+FARADAY.

09:16 Prueba de TX3 sin screen.
09:18 Prueba de TX3 con screen
09:27 Prueba con RF

En todas las pruebas el nivel de coherencia y fase estaban bien. "	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	294	22-01-12 / 18:03 FIN de experimento	ISR	JRO Staff	End experiment	L.Condori	new	2012-01-23T10:53:19-05:00	2012-10-03T12:14:37-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	293	22-01-12 / 17:16 Continua campo magnético perturbado	ISR	JRO Staff	General	L.Condori	new	2012-01-23T10:52:27-05:00	2012-10-03T12:15:22-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	292	22-01-12 / 15:24 Calibración de ATRS y TRS	ISR	JRO Staff	Spark Gaps	A. Coronado	new	2012-01-23T10:51:45-05:00	2012-10-03T12:16:14-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	291	22-01-12 / 13:32 Caída del campo magnético	ISR	JRO Staff	General	L.Condori	new	2012-01-23T10:50:34-05:00	2012-10-03T12:17:17-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	290	22-01-12 / 13:05 Se prende GPS	ISR	JRO Staff	General	L.Condori	new	2012-01-23T10:49:46-05:00	2012-10-03T12:17:54-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	289	22-01-12 / 13:03 Caída de tensión	ISR	JRO Staff	Transmitters	L.Condori	new	2012-01-23T10:48:37-05:00	2012-10-03T12:19:48-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	288	22-01-12 / 12:30 Calibración de ATRS y TRS	ISR	JRO Staff	Spark Gaps	A. Coronado	new	2012-01-23T10:46:09-05:00	2012-10-03T12:20:09-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	287	22-01-12 / 12:08 Cae campo magnético	ISR	JRO Staff	General	L.Condori	new	2012-01-23T10:45:23-05:00	2012-10-03T12:20:31-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	286	22-01-12 / 11:06  Pico del ruido del Cielo	ISR	JRO Staff	General	L.Condori	new	2012-01-23T10:44:35-05:00	2012-10-03T12:21:47-05:00	Estamos saliendo de la zona del pico del ruido del cielo (10:30).	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	285	22-01-12 / 09:17 Calibración de ATRS y TRS	ISR	JRO Staff	Spark Gaps	A. Coronado	new	2012-01-23T10:42:28-05:00	2012-10-03T12:22:06-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	284	22-01-12 / 07:44 Variaciones en campo magnético	ISR	JRO Staff	General	L.Condori	new	2012-01-23T10:41:14-05:00	2012-10-03T12:23:08-05:00	"Campo magnético cae en 100 nT
Solar Flare X-Ray 1.0-8.0 A subiendo a C2"	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	283	22-01-12 / 06:26 Calibración de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Alvarado	new	2012-01-23T10:38:19-05:00	2012-10-03T12:23:50-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	282	22-01-12 / 03:52 Calibración de ATRS y TRS del canal C	ISR	JRO Staff	Spark Gaps	W. Alvarado	new	2012-01-23T10:36:18-05:00	2012-10-03T12:24:09-05:00	Ajuste de chisperos del canal C	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	281	22-01-12 / 01:45 Calibración de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Alvarado	new	2012-01-23T10:35:18-05:00	2012-10-03T12:24:44-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	280	22-01-12 / 01:08 Caída de Tensión	ISR	JRO Staff	Transmitters		new	2012-01-23T10:34:29-05:00	2012-10-03T12:25:16-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	279	22-01-12 / 00:35 Calibración de ATRS y TRS del canal A	ISR	JRO Staff	Spark Gaps	W. Alvarado	new	2012-01-23T10:32:05-05:00	2012-10-03T12:26:19-05:00	Calibración de chisperos del canal A	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	278	22-01-12 / 00:23 Calibración de ATRS y TRS del canal C	ISR	JRO Staff	Spark Gaps	W. Alvarado	new	2012-01-23T10:30:30-05:00	2012-10-03T12:26:36-05:00	Calibracion de chispero del canal C	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	277	21-01-12 / 22:36 Calibración ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Alvarado	new	2012-01-23T10:29:29-05:00	2012-10-03T12:27:02-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	276	21-01-12 / 18:36 Se inicia la toma de datos	ISR	JRO Staff	Start experiment	Rita Abad	new	2012-01-23T10:27:06-05:00	2012-10-03T12:27:34-05:00	"- Se inicia toma de datos.
18:50-19:00 Baja el nivel de ruido del canal B, por escoria en chispero. "	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	275	21-01-12 / 10:00 Se detiene experimento por corte de energía (LUZ del SUR)	ISR	JRO Staff	General	Rita Abad	new	2012-01-23T10:16:32-05:00	2012-10-03T12:27:53-05:00	"
- Se detiene experimento por corte de energía.

- Luz del Sur corto la energía exactamente a las 10:30, pero desde las 09:36 hubo caída de tensión en Jicamarca."	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	274	09:35 Caida de tension	ISR	JRO Staff	Transmitters	R. Abad	new	2012-01-21T09:37:00-05:00	2012-10-03T12:28:12-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	273	09:09 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Rojas	new	2012-01-21T09:07:57-05:00	2012-10-03T12:28:40-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	272	2012-01-21/ 07:15 - Caída de Tension en Linea PA2	ISR	JRO Staff	General		new	2012-01-21T07:43:23-05:00	2012-10-03T12:29:07-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	271	2012-01-21/ 06:29 - Ajuste de Chisperos ATRs y TRs	ISR	JRO Staff	General		new	2012-01-21T07:42:53-05:00	2012-10-03T12:29:39-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	270	2012-01-21/ 04:31 - Ajuste de Chisperos ATRs	ISR	JRO Staff	General		new	2012-01-21T07:41:50-05:00	2012-10-03T13:39:57-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	269	2012-01-21/ 02:36 - Ajuste de Chisperos ATRs y TRs	ISR	JRO Staff	General		new	2012-01-21T07:41:18-05:00	2012-10-03T13:40:56-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	268	2012-01-21/ 01:42 - Hydra Canales A y B	ISR	JRO Staff	General		new	2012-01-21T07:40:43-05:00	2012-10-03T13:41:57-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	267	2012-01-21/ 01:15 - Hydra Canales C y D	ISR	JRO Staff	General		new	2012-01-21T07:40:11-05:00	2012-10-03T13:42:13-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	266	2012-01-21/ 00:23 - Ajuste de Chisperos ATRs	ISR	JRO Staff	General		new	2012-01-21T07:38:47-05:00	2012-10-03T13:42:50-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	265	2012-01-20/ 23:34 - Ajuste de Chisperos TRs	ISR	JRO Staff	General		new	2012-01-21T07:38:03-05:00	2012-10-03T13:43:12-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	264	2012-01-20/ 22:26 - Ajuste de Chisperos ATRs	ISR	JRO Staff	General		new	2012-01-21T07:37:29-05:00	2012-10-03T13:43:34-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	263	2012-01-20/ 21:33 - Ajuste de Chisperos TRs	ISR	JRO Staff	General		new	2012-01-21T07:36:56-05:00	2012-10-03T13:43:55-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	262	2012-01-20/ 20:22 - Ajuste de ATRs	ISR	JRO Staff	General		new	2012-01-21T07:36:15-05:00	2012-10-03T13:44:57-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	261	Incidencias en el transmisor	ISR	JRO Staff	Transmitters		new	2012-01-20T19:32:30-05:00	2012-10-03T13:45:14-05:00	"
Hora     TX     Potencia
08:00     1        32KW
          2        33KW
09:20     1        32KW
          2        33KW
10:30     1        32KW
          2        33KW
10:38 RF OFF, HV OFF cambio en tungstenos
10:56 HV ON
10:58 Cae fuente SCREEN PA1
11:32 Crowbar fuente 20KV
11:45     1        31KW
          2        31KW
12:00     1        35KW
          2        35KW
12:20 Crowbar fuente 20KV
12:25 Crowbar fuente 20KV, se realiza limpieza de circuito crowbar
12:45 Cae fuente SCREEN PA1
14:00     1        30KW
          2        30KW
15:00     1        30KW
          2        31KW
16:00     1        29KW
          2        29KW
17:00     1        31KW
          2        32KW
18:00     1        31KW
          2        31KW
19:00     1        31KW
          2        31KW"	ryaya
Milestone 2012_01 ISCOD Campaign Jan 12-23	260	16:30 ajuste de chispero del canal B	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-01-20T17:48:30-05:00	2012-10-03T13:45:38-05:00	Hay residuos en los chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	259	16:10 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-01-20T17:47:50-05:00	2012-10-03T13:46:15-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	258	11:30 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-01-20T17:46:49-05:00	2012-10-03T13:46:32-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	257	10:39 Cambio de chisperos ATrs	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-01-20T10:40:25-05:00	2012-10-03T13:46:53-05:00	"Cambio de chisperos ATRs en el pico de la galaxia. El cambio se debe a desagaste.
Se apagan los transmisores para poder hacer el cambio."	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	256	10:20 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-01-20T10:39:28-05:00	2012-10-03T13:47:24-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	255	08:10 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	J.Lavado	new	2012-01-20T10:38:58-05:00	2012-10-03T13:47:54-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	254	Lectura de Potencias	ISR	JRO Staff	General		new	2012-01-20T07:09:32-05:00	2012-10-03T13:48:24-05:00	"19 de  Enero 2012

20:00 1 16.5 V 35 Kw, 4080 Vac, 350 Kv
     2 16.5 V 35 Kw
21:00 1 16.5 V 35 Kw, 4080 Vac, 350 Kv
     2 16.5 V 35 Kw
22:00 1 16.5 V 34 Kw, 4050 Vac, 340 Kv
     2 16.5 V 34 Kw
23:00 1 16.5 V 33 Kw
     2 16.5 V 33 Kw

20 de Enero 2012

01:00 1 16.5 V 33 Kw
     2 16.5 V 33 Kw
02:00 1 16.5 V 32 Kw, 4000 Vac, 350 Kv
     2 16.5 V 32 Kw
03:00 1 16.5 V 32 Kw
     2 16.5 V 32 Kw
04:00 1 16.5 V 31 Kw, 3950 Vac, 340 Kv
     2 16.5 V 31 Kw
05:00 1 16.5 V 31 Kw
     2 16.5 V 31 Kw
06:00 1 16.5 V 32 Kw, 3980 Vac, 350 Kv
     2 16.5 V 32 Kw
07:00 1 16.5 V 33 Kw
     2 16.5 V 33 Kw"	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	253	06:15 Calibración chisperos, canal A	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-20T06:14:47-05:00	2012-10-03T13:48:55-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	252	06:03 Calibración de ATRs y TRs	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-20T06:00:58-05:00	2012-10-03T13:49:22-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	251	03:18 Calibración de chisperos, canal C	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-20T03:17:53-05:00	2012-10-03T13:49:44-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	250	00:57 Calibración de ATR's y TR's	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-20T00:55:39-05:00	2012-10-03T13:50:04-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	249	21:51 Calibración ATRs y TRs	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-19T21:49:34-05:00	2012-10-03T13:50:26-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	248	20:03 Ajuste de chisperos canal D	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-19T20:13:59-05:00	2012-10-03T13:50:42-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	247	17:23 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Rojas	new	2012-01-19T17:38:58-05:00	2012-10-03T13:50:57-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	246	16:43 Se quita RF a TXs por 5 min	ISR	JRO Staff	Antennas	W. Rojas y A. Coronado	new	2012-01-19T17:37:35-05:00	2012-10-03T13:51:19-05:00	"Se quita RF, debido a que se noto chispasos en el modulo 8 del cuarto Este de la Antena Principal.

Se realiza mantenimiento a la linea de alimentacion (cambio y ajuste de tornillos sueltos) en el modulo 8."	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	245	14:29 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Rojas	new	2012-01-19T15:26:12-05:00	2012-10-03T13:51:39-05:00	Claibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	244	11:10 Calibracion de TRS en canal B	ISR	JRO Staff	Spark Gaps	W. Rojas	new	2012-01-19T15:24:56-05:00	2012-10-03T13:51:56-05:00	Ajuste de chisperos del canal B	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	243	11:15 Se detecta X-Ray Solar Flares	ISR	JRO Staff	General	R. Abad	new	2012-01-19T15:11:28-05:00	2012-10-03T13:52:22-05:00	"Segun la pagina space Weather.com X-Ray Solar Flares aparecen desde las 08:40 aproximadamente.

En Jicamarca se vio con mayor intensidad desde 11:15 hasta 02:00. Este fenomeno continuo hasta un poco mas de las 15:00 pero con menor intensidad.  "	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	242	10:15 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Rojas	new	2012-01-19T10:12:28-05:00	2012-10-03T13:52:39-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	241	08:28 Caida de tension	ISR	JRO Staff	Transmitters	R. Tadeo	new	2012-01-19T08:28:54-05:00	2012-10-03T13:54:22-05:00		rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	240	07:58 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	W. Rojas	new	2012-01-19T08:03:23-05:00	2012-10-03T13:54:36-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	239	Graficas de RTI, Drifts	ISR	JRO Staff	Process/Analysis Program	Percy Condor	new	2012-01-19T07:31:19-05:00	2012-10-03T13:55:13-05:00	Plot de rtis, drifts, espectros del 18-01-2012 y 19-01-2012 hasta las 08:00 horas	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	238	Lecturas de Potencias	ISR	JRO Staff	General		new	2012-01-19T07:04:39-05:00	2012-10-03T13:55:33-05:00	"18 de Enero 2012

20:00 1 16.5V 33  Kw
21:00 1 16.5V 33  Kw, 4020 Vac, 350 Kw
     2 16.5V 37  Kw
22:00 1 16.5V 33  Kw
     2 16.5V 37  Kw
23:00 1 16.5V 33  Kw
     2 16.5V 37  Kw

19 Enero 2012

00:00 1 16.5V 33  Kw
     2 16.5V 37  Kw
01:00 1 16.5V 33  Kw
     2 16.5V 37  Kw
02:00 1 16.5V 33  Kw
     2 16.5V 37  Kw
03:00 1 16.5V 31  Kw
     2 16.5V 34  Kw, 3950 Vac, 350 Kw
04:00 1 16.5V 31  Kw
     2 16.5V 34  Kw
05:00 1 16.5V 31  Kw
     2 16.5V 33  Kw, 3920 Vac, 330 Kw
06:00 1 16.5V 32  Kw
     2 16.5V 35  Kw, 3950 Vac, 430 Kw
07:00 1 16.5V 32  Kw
     2 16.5V 35  Kw"	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	237	06:10 AJUSTE DE CHISPEROS ATRs y TRs.	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-19T06:09:37-05:00	2012-10-03T13:56:08-05:00	AJUSTE DE CHISPEROS ATRs y TRs.	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	236	03:05 AJUSTE DE CHISPEROS ATRs y TRs.	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-19T03:04:20-05:00	2012-10-03T13:56:24-05:00	AJUSTE DE CHISPEROS ATRs y TRs.	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	235	00:23 AJUSTE DE CHISPEROS ATRs y TRs	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-19T00:22:42-05:00	2012-10-03T13:56:39-05:00	AJUSTE DE CHISPEROS ATRs y TRs.	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	234	21:26 AJUSTE DE CHISPEROS ATRs y TRs.	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-18T21:28:38-05:00	2012-10-03T13:57:00-05:00	AJUSTE DE CHISPEROS ATRs y TRs.	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	233	19;11 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	jose lavado	new	2012-01-18T19:10:48-05:00	2012-10-03T13:57:28-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	232	17:10 Calibracion de TR del canal C	ISR	JRO Staff	Spark Gaps	Jose Lavado	new	2012-01-18T17:10:40-05:00	2012-10-03T13:57:44-05:00	calibracion del chispero del canal C.	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	231	16:35 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	Jose Lavado	new	2012-01-18T17:09:33-05:00	2012-10-03T13:58:02-05:00	Calibracion de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	230	14:14 Calibracion de ATRs y TRs	ISR	JRO Staff	Spark Gaps	Karim Kuyeng	new	2012-01-18T14:27:08-05:00	2012-10-03T13:58:30-05:00	Calibracion de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	229	12:30 Perdida de datos	ISR	JRO Staff	Acquisition system	Karim Kuyeng	new	2012-01-18T14:26:20-05:00	2012-10-03T13:58:53-05:00	El sistema de adquisicion pierde datos debido a que se exigio demasiado la PC ARES cuando por error se dejo corriendo el programa Display para visualizar RAW DATA.	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	228	11:44 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	Jose Lavado	new	2012-01-18T11:57:22-05:00	2012-10-03T13:59:10-05:00	Calibracion de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	227	10:50 Caida de tension	ISR	JRO Staff	Transmitters	Karim Kuyeng	new	2012-01-18T11:07:46-05:00	2012-10-03T13:59:29-05:00	Caida de tension	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	226	09:15 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	J. Lavado	new	2012-01-18T09:29:35-05:00	2012-10-03T13:59:54-05:00	Calibracion de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	225	17-01-2012 / 17:56 Cambio de TR en el canal C	ISR	JRO Staff	Reception	Luis Condori	new	2012-01-18T09:24:17-05:00	2012-10-03T14:01:07-05:00	Cambio del TR en el canal C, debido a que tenia una diferencia de 1 dB con respecto a los otros canales.	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	224	08:00 Coherencia del ruido	ISR	JRO Staff	General	Karim Kuyeng	new	2012-01-18T08:18:18-05:00	2012-10-03T14:01:25-05:00	"La coherencia del ruido en las alturas de arriba ha desaparecido de nuevo. Por ahora todo esta bien

Puede ser problema de alguna fuente en los transmisores que esta generando este ruido intenso que se mete en los canales y hace que la coherencia del ruido suba.
"	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	223	07:16 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:16:12-05:00	2012-10-03T14:01:47-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	222	06:53 Reinicio de adquisicion - Falla en puerto paralelo	ISR	JRO Staff	Acquisition system	M.Inonan	new	2012-01-18T08:15:45-05:00	2012-10-03T14:02:04-05:00	"Cuando se trata de programar el DDS y divisor con la PC Ares se nota que el puerto paralelo esta fallando, por lo que la programacion de esos equipos se realiza con la pc que esta debajo de Ares.

"	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	221	06:23 FAlla en UPS	ISR	JRO Staff	General	M.Inonan	new	2012-01-18T08:13:30-05:00	2012-10-03T14:02:32-05:00	"Ocurre falla en el UPS que alimenta los sistemas de adquisicion y de procesamiento.
Se ha retirado el UPS de la pc de adquisicion para cualquier futura eventualidad.
"	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	220	06:20 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:08:03-05:00	2012-10-03T14:03:26-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	219	04:15 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:07:18-05:00	2012-10-03T14:04:00-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	218	02:31 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:06:54-05:00	2012-10-03T14:04:36-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	217	00:35 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:04:38-05:00	2012-10-03T14:05:42-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	216	17/01/2012, 23:21 calibracion de los TRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:04:07-05:00	2012-10-03T14:05:58-05:00	Se ajustan los TRs de B y C	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	215	17/01/2012, 22:28 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	A.Belleza	new	2012-01-18T08:03:07-05:00	2012-10-03T14:07:06-05:00	calibracion de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	214	(07:30) Incidencias en el transmisor	ISR	JRO Staff	Transmitters		new	2012-01-18T07:28:32-05:00	2012-10-03T14:07:42-05:00	"Lectura de Potencias e incidencias en el TX
17/01/2012
Hora      TX        Potencia
20:40      1          35 KW
           2          41 KW
21:40 Se ajusta niveles de potencia en PA1 y PA2 por saturación de los Drivers
21:40      1          muestra +6 dBm  <>  39.8 KW
           2          muestra +6 dBm  <>  39.8 KW
22:30      1          32 KW
           2          36 KW
23:00      1          33 KW
           2          37 KW

18/01/2012
00:00 CROWBAR en fuente 20KV
00:05      1          32 KW
           2          35 KW
01:00      1          33 KW
           2          35 KW
02:00      1          32 KW
           2          35 KW
03:00      1          32 KW
           2          35 KW
04:00      1          31 KW
           2          34 KW
05:00      1          31 KW
           2          34 KW
06:00      1          31 KW
           2          33 KW
06:40  RF OFF por problemas en sistema de adquisición
07:00      1          32 KW
           2          35 KW
 









"	ryaya
Milestone 2012_01 ISCOD Campaign Jan 12-23	213	Transmisor 2 saturado	ISR	JRO Staff	Transmitters		new	2012-01-17T21:43:33-05:00	2012-10-03T14:08:00-05:00	"Se corrigio la potencia del tranmisor debido a que estaba saturado 
De 21.36 a 21.40"	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	212	Lectura de Potencias	ISR	JRO Staff	Transmitters		new	2012-01-17T19:13:13-05:00	2012-10-03T14:18:53-05:00	"17 Enero del 2012
08:00   2   16.5V  30 Kw, 4080 Vac, 260 Kw
09:00   2   16.5V  28 Kw
10:00   2   16.5V  29 Kw
10:15   HV OFF para poner en funcionamiento Tx1
10:25   LV OFF
11:15   LV ON
11:20   HV ON
11:30   1   16.5V   31  Kw
        2   16.5V   36  Kw
11:39   1   16.5V   32  Kw, +6.3 dBm
        2   16.5V   37  Kw, +6.0 dBm
11:39   1   16.5V   33  Kw, Scrn Diver: 650 VDC
        2   16.5V   36  Kw, Scrn Diver: 500 VDC
11:49   1   16.5V   41  Kw, +6.2 dBm
        2   16.5V   41  Kw, +6.2 dBm
12:19 Crowbar por caida de tension
13:00   1   16.5V   35  Kw, 4000 Vac, 350 Kw
        2   16.5V   39  Kw
13:10 Cae fuente de fuente de screen Tx1
14:00   1   16.5V   33  Kw
        2   16.5V   36  Kw
15:00   1   16.5V   33  Kw
        2   16.5V   36  Kw
16:00   1   16.5V   33  Kw, 3960 Vac, 340 Kw
        2   16.5V   37  Kw
17:00   1   16.5V   33  Kw
        2   16.5V   37  Kw
18:00   1   16.5V   35  Kw, 4020 Vac, 360 Kw
        2   16.5V   40  Kw
19:00   1   16.5V   36  Kw
        2   16.5V   41  Kw, 4050Vac, 370 Kw"	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	211	Ruido a las 11:57am	ISR	JRO Staff	General	Dcordova	new	2012-01-17T11:57:31-05:00	2012-10-03T14:19:06-05:00	"A: 30.65 dB
B: 31.34 dB
C: 29.88 dB
D: 30.52 dB"	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	210	Reinicio de experimento con 2 transmisores	ISR	JRO Staff	General		new	2012-01-17T11:47:11-05:00	2012-10-03T14:19:21-05:00	11:44 Se reinicia el experimento con dos transmisores Tx1 y Tx2	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	209	Detiene radar a las 10:15 am	ISR	JRO Staff	Spark Gaps	Dcordova	new	2012-01-17T11:07:52-05:00	2012-10-03T14:19:33-05:00	"10:15 se detiene transmision y recepcion para cambio de chispero y habilitar Tx1, para ello se va a conectar al H3.
"	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	208	Ruido a las 8:32am	ISR	JRO Staff	General		new	2012-01-17T08:41:38-05:00	2012-10-03T14:19:45-05:00	"Debido a que la senial en B disminuyo mas de 2 dB, se cambio TR.
Los valores del ruido a las 8:38 son:
A: 29.06 dB
B: 29.69 dB
C: 28.38 dB
D: 29.09 dB"	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	207	(07:30) Lectura de potencias y tensión de línea	ISR	JRO Staff	Transmitters		new	2012-01-17T07:37:53-05:00	2012-10-03T14:19:57-05:00	"16/01/2012
Hora  TX  Potencia
21:00  2    29KW
22:00  2    29KW
23:00  2    28KW
17/01/2012
00:00  2    28KW
01:00  2    27KW
02:00  2    27KW
03:00  2    27KW
04:00  2    27KW
05:00  2    27KW
06:00  2    27KW
07:00  2    28KW"	ryaya
Milestone 2012_01 ISCOD Campaign Jan 12-23	206	17-01-2012 / 06:56 Ajuste de ATRs	ISR	JRO Staff	General		new	2012-01-17T07:24:55-05:00	2012-10-03T14:20:08-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	205	17-01-2012 / 06:00 Ajuste de ATRs	ISR	JRO Staff	General		new	2012-01-17T07:24:33-05:00	2012-10-03T14:20:21-05:00	Solo quedan dos tungstenos	dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	204	17-01-2012 / 05:00 Ajuste de ATRs	ISR	JRO Staff	General		new	2012-01-17T07:23:49-05:00	2012-10-03T14:20:31-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	203	17-01-2012 / 03:03 Ajuste de ATRs	ISR	JRO Staff	General		new	2012-01-17T07:23:28-05:00	2012-10-03T14:20:43-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	202	17-01-2012 / 01:30 Pase de Hydra por canal C y D	ISR	JRO Staff	General		new	2012-01-17T07:22:42-05:00	2012-10-03T14:20:54-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	201	17-01-2012 / 00:56 Ajuste de ATRs	ISR	JRO Staff	General		new	2012-01-17T07:21:29-05:00	2012-10-03T14:21:04-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	200	Lectura de Potencioas	ISR	JRO Staff	Transmitters	Victor Quesada	new	2012-01-16T19:21:53-05:00	2012-10-03T14:21:23-05:00	"16 de Enero del 2012
08:25 2 16.5V +4.9 dbm  30.90 Kw
09:00 2 16.5V +4.8 dbm  30.20 Kw
10:00 2 16.5V +4.8 dbm  30.20 Kw
11:00 2 16.5V +4.8 dbm  30.20 Kw
12:00 2 16.5V +4.8 dbm  30.20 Kw
13:00 2 16.5V +4.8 dbm  30.20 Kw
14:00 2 16.5V +4.9 dbm  30.90 Kw
15:00 2 16.5V +4.9 dbm  30.90 Kw
16:00 2 16.5V +4.8 dbm  30.20 Kw
17:00 2 16.5V +4.8 dbm  30.20 Kw
18:00 2 16.5V +4.8 dbm  30.20 Kw
19:00 2 16.5V +4.8 dbm  30.20 Kw"	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	199	Importante: CCF Coherence	ISR	JRO Staff	General		new	2012-01-16T14:34:07-05:00	2012-10-03T14:21:33-05:00	Se observa que el valor de la coherencia tiene que ser baja, como muestra la figura1, en las alturas altas donde no hay senial solo ruido (a partir de 500Km): por ello se debe observar que la fase entre AB y CD debe verse aleatoria (figura 2) y no tienda a un color (figura 3).	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	198	Reinicia sistema de adquisicion	ISR	JRO Staff	General		new	2012-01-16T12:19:40-05:00	2012-10-03T14:21:52-05:00	"12:12 Se reinicia sistema de adquisicion
Se vuelve a cargar programa de procesamiento"	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	197	Comportamiento anomalo del campo	ISR	JRO Staff	Other Instruments		new	2012-01-16T11:13:13-05:00	2012-10-03T14:22:04-05:00	Se observa que el el campo en Piura y Jicamarca es extranio, se adujanta los graficos de estos campos magneticos	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	196	Actualizacion de hora	ISR	JRO Staff	General		new	2012-01-16T09:31:10-05:00	2012-10-03T14:22:16-05:00	8:08 Se ajusta el servidor de tiempo porque se encontro apagado el GPS Garmin. El retrazo fue de 3 minutos.	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	195	Ruido a las 8:17am	ISR	JRO Staff	General		new	2012-01-16T08:16:47-05:00	2012-10-03T14:22:27-05:00	"hora: 8:18:30
A: 28.71 dB
B: 29.78 dB
C: 27.41 dB
D: 28.88 dB"	dcordova
Milestone 2012_01 ISCOD Campaign Jan 12-23	194	Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2012-01-16T07:03:27-05:00	2012-10-03T14:22:43-05:00	"
15 Enero 2012
20:00        2     16.5V       32 Kw         4100 VAC, 230 Kw
21:00        2     16.5V       32 Kw         4100 VAC, 220 Kw
22:00        2     16.5V       32 Kw         
23:00        2     16.5V       32 Kw         
16 Enero 2012
00:00        2     16.5V       30 Kw         4050 VAC, 220 Kw
01:00        2     16.5V       30 Kw         4050 VAC, 220 Kw
02:00        2     16.5V       30 Kw         
03:00        2     16.5V       30 Kw         4050 VAC, 220 Kw
04:17        2     16.5V       +4.5dBm       4050 VAC, 220 Kw
05:00        2     16.5V       +5.0dBm         
06:00        2     16.5V       +4.5dBm         
07:00        2     16.5V       +4.5dBm       4050 VAC, 220 Kw

"	rtadeo
Milestone 2012_01 ISCOD Campaign Jan 12-23	193	06:05 Calibración de ATR's y TR's	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-16T06:04:51-05:00	2012-10-03T14:22:57-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	192	03:45 Calibración de ATR's y TR's	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-16T03:44:14-05:00	2012-10-03T14:23:12-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	191	00:50 Calibración de ATR's y TR's	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-16T00:52:35-05:00	2012-10-03T14:23:25-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	190	21: 44 Ajuste de chisperos ATRs y TRs	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-15T21:49:13-05:00	2012-10-03T14:23:37-05:00		imanay
Milestone 2012_01 ISCOD Campaign Jan 12-23	189	Lecturas de Potencias	ISR	JRO Staff	Transmitters		new	2012-01-15T19:28:32-05:00	2012-10-03T14:23:54-05:00	"15 de Enero del 2012
08:25  2    16.5V   31 Kw, 4050 Vac, 260 Kw
09:00  2    16.5V   31 Kw
10:00  2    16.5V   30 Kw
11:00  2    16.5V   31 Kw
12:00  2    16.5V   30 Kw, 4050 Vac, 260 Kw
13:00  2    16.5V   31 Kw
14:00  2    16.5V   31 Kw
15:00  2    16.5V   32 Kw, 4100 Vac, 260 Kw
16:00  2    16.5V   32 Kw
16:22 Crowbar por caida de tension
17:00  2    16.5V   32 Kw
18:00  2    16.5V   32 Kw
19:00  2    16.5V   32 Kw"	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	188	18:16 Calibracion de ATRS y TRS	ISR	JRO Staff	Spark Gaps	Rita Abad	new	2012-01-15T19:02:09-05:00	2012-10-03T14:24:06-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	187	16:18 Caida de tension	ISR	Others	Transmitters	Rita Abad	new	2012-01-15T16:25:51-05:00	2012-10-03T14:24:23-05:00	Caida de tension, fuente de alta tension	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	186	15:50 Calibracion ATRs y TRs	ISR	Others	Spark Gaps	Rita Abad	new	2012-01-15T16:24:32-05:00	2012-10-03T14:24:35-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	185	13:38 Calibracion ATRs y TRs	ISR	Others	Spark Gaps	Rita Abad	new	2012-01-15T16:23:42-05:00	2012-10-03T14:25:09-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	184	10:56 Calibracion de ATRs y TRs	ISR	Others	Spark Gaps	Rita Abad	new	2012-01-15T16:22:55-05:00	2012-10-03T14:25:31-05:00	Ajuste de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	183	08:45 Calibracion ATRs y TRs	ISR	Others	Transmitters	Rita Abad	new	2012-01-15T16:22:03-05:00	2012-10-03T14:25:43-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	182	15-01-12 Plots	ISR	JRO Staff	Process/Analysis Program	P. Condor P.	new	2012-01-15T08:04:25-05:00	2012-10-03T14:26:03-05:00	Figuras de rti, Drfits y espectros	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	181	15-01-12 07:13 Ajuste de Chisperos	ISR	JRO Staff	Antennas	P. Condor P.	new	2012-01-15T08:01:09-05:00	2012-10-03T14:26:20-05:00	Ajuste de Chisperos ATrs y Trs	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	180	15-01-12 05:30 Ajuste de Chisperos	ISR	JRO Staff	Antennas	P. Condor P.	new	2012-01-15T08:00:40-05:00	2012-10-03T14:26:31-05:00	Ajuste de Chisperos ATrs y Trs	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	179	15-01-12 03:30 Ajuste de Chisperos	ISR	JRO Staff	Antennas	P. Condor P.	new	2012-01-15T07:54:51-05:00	2012-10-03T14:26:50-05:00	Ajuste de Chisperos ATrs y Trs	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	178	15-01-12 01:08 Ajuste de Chisperos	ISR	JRO Staff	Antennas	P. Condor P.	new	2012-01-15T07:53:48-05:00	2012-10-03T14:27:07-05:00	Ajuste de chisperos ATrs y Trs	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	177	14-01-12 23:20 Ajuste de Chisperos	ISR	JRO Staff	Antennas	P. Condor P.	new	2012-01-15T07:52:42-05:00	2012-10-03T14:27:20-05:00	Ajuste de Chisperos Atrs y Trs	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	176	14-01-12 22:08 Ajuste de Chisperos	ISR	JRO Staff	Antennas	P. Condor P.	new	2012-01-15T07:51:19-05:00	2012-10-03T14:27:34-05:00	Ajsute de Chisperos ATRs y Trs	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	175	Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2012-01-15T07:49:57-05:00	2012-10-03T14:27:45-05:00	"14 Enero del 2012
00:00 2 16.5V 30 Kw, 3950 VAC, 260 Kw
01:00 2 16.5V 29 Kw
02:00 2 16.5V 29 Kw
14/01/2012

hora         Tx        Fil        Pot          linea
20:10 Crowbar por subida de tensión
20:55 Crowbar por subida de tensión
21:05 Crowbar por subida de tensión
21:05         2         16.5      30           4000Vac
22:00         2         16.5      30           4000Vac
23:00         2         16.5      31           4050Vac
15/01/2012
00:00         2         16.5      30           4000Vac
01:00         2         16.5      20           3950Vac
02:00         2         16.5      29           3950Vac
03:00         2         16.5      30           4000Vac
04:00         2         16.5      30           4000Vac
05:00         2         16.5      30           4000Vac
06:00         2         16.5      29           3950Vac
07:00         2         16.5      30           4050Vac
07:25   falla ckto crowbar"	rtadeo
Milestone 2012_01 ISCOD Campaign Jan 12-23	174	14-01-12 21:04 Caida de Tension	ISR	JRO Staff	Transmitters	P. Condor P.	new	2012-01-15T07:49:53-05:00	2012-10-03T14:27:58-05:00	Caida de Tension	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	173	14-01-12 19:55 Caida de Tension	ISR	JRO Staff	Transmitters	P Condor P.	new	2012-01-15T07:48:02-05:00	2012-10-03T14:28:13-05:00	Caida de Tension	pcondor
Milestone 2012_01 ISCOD Campaign Jan 12-23	172	19:55 Caida de tension	ISR	Others	Transmitters	Rita Abad	new	2012-01-14T20:05:50-05:00	2012-10-03T14:28:28-05:00	Caida de alta tension	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	171	18:55 Se reinicia experimento	ISR	Others	Start experiment	Rita Abad	new	2012-01-14T19:53:41-05:00	2012-10-03T14:28:46-05:00	"No se realizan cambios.
Sale solo experimento EW_Drift. "	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	170	17:10 Se detiene experimento para colocar bomba de agua	ISR	Others	Transmitters	Ing. Otto	new	2012-01-14T19:17:48-05:00	2012-10-03T14:29:02-05:00	"
Se detiene experimento para colocar la bomba de agua que se llevo a reparar, lamentablemente no paso la prueba pues a los minutos de estar operativa comenzo a fallar (salio humo)."	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	169	16:15 Calibracion ATRs y TRs	ISR	Others	Spark Gaps	J. Lavado	new	2012-01-14T17:04:15-05:00	2012-10-03T14:30:39-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	168	12:20 Calibracion de ATRs y TRs	ISR	Others	Spark Gaps	J. Lavado	new	2012-01-14T12:21:32-05:00	2012-10-03T14:31:10-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	167	08:30 calibracion de los ATRs y TRs	ISR	Others	Spark Gaps	J. Lavado	new	2012-01-14T08:39:47-05:00	2012-10-03T14:31:44-05:00	Calibracion de chisperos	rabad
Milestone 2012_01 ISCOD Campaign Jan 12-23	166	Lecturas de Potencias	ISR	JRO Staff	Transmitters		new	2012-01-14T07:19:32-05:00	2012-10-03T14:31:59-05:00	"14 Enero del 2012
00:00  2  16.5V  30 Kw, 3950 VAC, 260 Kw
01:00  2  16.5V  29 Kw
02:00  2  16.5V  29 Kw
02.39 Crowbar por caida de tensión
03:00  2  16.5V  30 Kw
04:00  2  16.5V  30 Kw, 3950 Vac, 260 Kw
04:50 Crowbar por caida de tensión
05:00  2  16.5V  29 Kw
06:00  2  16.5V  31 Kw
07:00  2  16.5V  31 Kw "	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	165	2012-01-14/ 06:45 - Ajuste de Chisperos ATRs y TRs	ISR	JRO Staff	General		new	2012-01-14T06:55:49-05:00	2012-10-03T14:32:18-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	164	2012-01-14/ 04:45 - Caída de Tension en Linea	ISR	JRO Staff	General		new	2012-01-14T06:55:15-05:00	2012-10-03T14:32:34-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	163	2012-01-14/ 04:30 - Ajuste de Chisperos ATRs y TRs	ISR	JRO Staff	General		new	2012-01-14T06:54:33-05:00	2012-10-03T14:32:55-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	162	2012-01-14/ 02:33 - Caída de Tension en Linea	ISR	JRO Staff	General		new	2012-01-14T06:53:37-05:00	2012-10-03T14:33:10-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	161	2012-01-14/ 02:10 - Hydra, canales A y B	ISR	JRO Staff	General		new	2012-01-14T06:52:48-05:00	2012-10-03T14:33:22-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	160	2012-01-14/ 02:05 - Ajuste de Chisperos TRs y ATRs	ISR	JRO Staff	General		new	2012-01-14T06:51:31-05:00	2012-10-03T14:33:45-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	159	2012-01-14/ 01:40 - Hydra en los canales C y D	ISR	JRO Staff	General		new	2012-01-14T06:49:43-05:00	2012-10-03T14:34:14-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	158	Lectura de potencias	ISR	JRO Staff	Transmitters		new	2012-01-14T04:06:30-05:00	2012-10-03T14:34:26-05:00	"12 de Enero del 2012
20:00
Tx    Fil         Pot Inc.
2     16.5 V      29 Kw 
21:00
Tx    Fil         Pot Inc.
2     16.5 V      29 Kw 
22:00
Tx    Fil         Pot Inc.
2     16.5 V      30Kw 
22:15 Crowbar por caida de tension
23:00
Tx    Fil         Pot Inc.
2     16.5 V      30 Kw 
23:36 Crowbar por caida de tension"	vquesada
Milestone 2012_01 ISCOD Campaign Jan 12-23	157	2012-01-14/ 00:12 - Ajuste de Chisperos ATRs y TRs	ISR	JRO Staff	General		new	2012-01-14T00:31:01-05:00	2012-10-03T14:34:42-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	156	2012-01-13/ 23:33 - Caída de Tension en Linea	ISR	JRO Staff	General		new	2012-01-14T00:30:08-05:00	2012-10-03T14:34:57-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	155	2012-01-13/ 22:38 - Caída de Tension en Linea	ISR	JRO Staff	General		new	2012-01-14T00:29:45-05:00	2012-10-03T14:35:07-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	154	2012-01-13/ 22:10 - Caída de Tension en Linea	ISR	JRO Staff	General		new	2012-01-14T00:27:15-05:00	2012-10-03T14:35:18-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	153	2012-01-13/ 21:40 - Ajuste de Chisperos ATRs y TRs	ISR	JRO Staff	General	Daniel Suarez	new	2012-01-14T00:24:59-05:00	2012-10-03T14:35:30-05:00		dsuarez
Milestone 2012_01 ISCOD Campaign Jan 12-23	152	Lectura de Potencia-Linea de Voltaje	ISR	JRO Staff	Transmitters	rtadeo	new	2012-01-13T19:45:28-05:00	2012-10-03T14:35:40-05:00	"12/Enero/2012
Hora 19:30    Tx2    Fil 16.5V     Pot(Kw):20Kw  Linea:4050Vac 3F 
21:00    Cambio de pulso 3.59%
22:00       2        16.5           32Kw             4020Vac  3F
23:00       2        16.5           32Kw 
13/Enero/2012            
00:00       2        16.5           32Kw 
01:00       2        16.5           32Kw
02:00       2        16.5           30Kw
03:00       2        16.5           31Kw
04:00       2        16.5           32Kw
05:00       2        16.5           29Kw   3900VAC 3F
06:00       2        16.5           29Kw
07:00       2        16.5           30Kw   crowbar
08:00       2        16.5           30Kw
09:00       2        16.5           28Kw
10:00       2        16.5           30Kw
11:00       2        16.5           31Kw
12:00       2        16.5           30Kw    4050VAC
13:00       2        16.5           29Kw    3950vac
14:00       2        16.5           28Kw    3900VAC
15:00       2        16.5           28Kw
16:00       2        16.5           26Kw    3890VAC
17:00       2        16.5           29Kw    3850VAC
18:00       2        16.5           29Kw    4000VAC
19:00       2        16.5           30Kw
19:45       2        16.5           29Kw







"	rtadeo
Milestone 2012_01 ISCOD Campaign Jan 12-23	151	2012_Enero_12 - 20:57 - Cambio en los pulsos	ISR	JRO Staff	Acquisition system	Karim Kuyeng	new	2012-01-13T19:32:18-05:00	2012-10-03T14:35:51-05:00	"Ya que solo está saliendo EW_ Drift entonces se cambian los pulsos para que ya no se espere a la parte de Faraday.
Ahora solo se tiene EW_Drift que es:

secuencia de pulsos: 128 Tx ON + 32 Tx OFF

Pulso sincronismo cada 160 veces(""out160.jam"") el pulso de la digisonda (en vez de los 300 que se tienen en EW_Drift + Faraday)."	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	150	2012_Enero_12 - 20:00 Inicio de experimento	ISR	JRO Staff	Start experiment	Karim Kuyeng	new	2012-01-13T19:29:43-05:00	2012-10-03T14:36:02-05:00	Luego de las pruebas se inicia el experimento usando los pulsos como si salieran EW_Drift+ Faraday, aunque solo se está adquiriendo y transmitiendo EW_Drift.	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	149	2012_Enero_12 - 19:00 Pruebas de experimento	ISR	JRO Staff	General	Karim Kuyeng	new	2012-01-13T19:28:30-05:00	2012-10-03T14:36:13-05:00	"Problemas con el transmisor Tx3 y con el Tx1, además del problema que tenemos solo una bomba de baja presión funcionando hacen que el experimento se corra con solo EW_Drift (no Faraday).
"	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	148	19:29 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	W.Rojas	new	2012-01-13T19:24:50-05:00	2012-10-03T14:37:54-05:00	Calibración de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	147	17:23 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	W.Rojas	new	2012-01-13T19:24:22-05:00	2012-10-03T14:38:08-05:00	Calibración de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	146	14:24 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	W.Rojas	new	2012-01-13T19:22:38-05:00	2012-10-03T14:38:30-05:00	Ajuste de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	145	(12:10) calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	W.Rojas	new	2012-01-13T19:21:50-05:00	2012-10-03T14:38:46-05:00		kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	144	09:38 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	W.Rojas	new	2012-01-13T19:20:45-05:00	2012-10-03T14:39:03-05:00	Ajuste de chisperos	kkuyeng
Milestone 2012_01 ISCOD Campaign Jan 12-23	143	07:30 calibracion de los ATRS y TRS	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-13T07:35:22-05:00	2012-10-03T14:39:16-05:00		murco
Milestone 2012_01 ISCOD Campaign Jan 12-23	142	04:45 calibracion de los ATRS	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-13T04:46:57-05:00	2012-10-03T14:39:27-05:00		murco
Milestone 2012_01 ISCOD Campaign Jan 12-23	141	04:20 calibracion de los ATRS	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-13T04:22:07-05:00	2012-10-03T14:39:39-05:00		murco
Milestone 2012_01 ISCOD Campaign Jan 12-23	140	03:13 calibracion de los TRS	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-13T03:17:29-05:00	2012-10-03T14:39:52-05:00		murco
Milestone 2012_01 ISCOD Campaign Jan 12-23	139	01:53 calibracion de los ATRS yTRS	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-13T01:55:47-05:00	2012-10-03T14:40:04-05:00		murco
Milestone 2012_01 ISCOD Campaign Jan 12-23	138	22:26 calibracion de los ATRS yTRS	ISR	JRO Staff	Antennas	Walter Alvarado	new	2012-01-12T22:28:31-05:00	2012-10-03T14:40:17-05:00		murco
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	137	07:30 - Error de Lectura online, salto en tiempo	ISR	JRO Staff	General	Daniel Suarez	new	2011-12-01T07:38:50-05:00	2012-10-03T14:42:02-05:00		dsuarez
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	136	05:37 Calibración de chisperos ATRs - TRs	ISR	JRO Staff	General	Walter Alvarado	new	2011-12-01T05:40:17-05:00	2012-10-03T14:42:50-05:00		dsuarez
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	135	(01:56) RF off	ISR	JRO Staff	Transmitters		new	2011-12-01T02:15:22-05:00	2012-10-03T14:43:05-05:00	Cae fuente Screen PA1, se reestablece y todo funciona normalmente	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	134	01:57 Calibración de chisperos ATRs - TRs	ISR	JRO Staff	General	Walter Alvarado	new	2011-12-01T02:03:02-05:00	2012-10-03T14:43:19-05:00		dsuarez
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	133	Imagenes del dia 30-11-2011	ISR	JRO Staff	General	Daniel Suarez	new	2011-12-01T00:11:35-05:00	2012-10-03T14:43:37-05:00		dsuarez
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	132	Calibracion de TRs y ATRs	ISR	JRO Staff	General	Walter Alvarado	new	2011-11-30T22:33:30-05:00	2012-10-03T14:43:51-05:00		dsuarez
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	131	16:15 Falla transmisores	ISR	Others	Transmitters	Rita Abad	new	2011-11-30T17:03:36-05:00	2012-10-03T14:44:03-05:00	"
- Cay'o fuente de alta tensi'on."	rabad
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	130	13:40 Calibraci'on ATRs y TRs	ISR	Others	Spark Gaps	Rita Abad	new	2011-11-30T16:49:19-05:00	2012-10-03T14:44:15-05:00	"
- Calibraci'on ATRs y TRs"	rabad
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	129	10:40 Calibraci'on  ATRs y TRs	ISR	Others	Spark Gaps	Rita Abad	new	2011-11-30T16:48:14-05:00	2012-10-03T14:44:26-05:00	"
- Calibraci'on de ATRs y TRs"	rabad
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	128	09:23 Falla TXs (Fuente TX1)	ISR	Others	Transmitters	Rita Abad	new	2011-11-30T16:45:45-05:00	2012-10-03T14:44:40-05:00	"

- Problemas con la fuente de TX1"	rabad
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	127	07:36 30-11-11 Calibracion de ATRs y TRs	ISR	JRO Staff	Antennas	A. Belleza	new	2011-11-30T07:45:08-05:00	2012-10-03T14:44:51-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	126	04:33 Perdio Sincronismo	ISR	JRO Staff	Process/Analysis Program	Percy Condor	new	2011-11-30T07:44:10-05:00	2012-10-03T14:45:05-05:00	Perdio Sincronismo, se reinicio DP_Faraday	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	125	04:32 30-11-11 Calibracion de ATRs y TRs	ISR	JRO Staff	Antennas	A. Belleza	new	2011-11-30T07:40:59-05:00	2012-10-03T14:45:19-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	124	(07:20) RF off	ISR	JRO Staff	Transmitters		new	2011-11-30T07:32:57-05:00	2012-10-03T14:45:37-05:00	Cae fuente de Screen PA1, se reestablece y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	123	(05:50) RF off	ISR	JRO Staff	Transmitters		new	2011-11-30T06:06:30-05:00	2012-10-03T14:45:50-05:00	Cae fuente Screen PA1, se reestablece y todo funciona normalmente	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	122	17:36 Calibracion de ATRs y TRs	ISR	JRO Staff	Antennas	A. Coronado	new	2011-11-30T01:02:02-05:00	2012-10-03T14:46:04-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	121	18:30 Perdio Sincronismo	ISR	JRO Staff	Process/Analysis Program	L. Condori	new	2011-11-30T00:58:59-05:00	2012-10-03T14:46:16-05:00	Perdio Sincronismo Faraday	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	120	23:48 Calibracion de ATRs y TRs	ISR	JRO Staff	Antennas	A. Belleza	new	2011-11-30T00:44:58-05:00	2012-10-03T14:46:29-05:00	Calibracion de ATRs y TRs	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	119	20:35 Calibracion de ATRs	ISR	JRO Staff	Antennas	A. Belleza	new	2011-11-30T00:36:27-05:00	2012-10-03T14:46:47-05:00	20:35 Calibracion de ATRs	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	118	Grafica 29-11-2011	ISR	JRO Staff	Plot	Percy Condor	new	2011-11-30T00:21:12-05:00	2012-10-03T14:47:02-05:00	Graficas de RTI, power, Espectros de EW_Drifts+Faraday	pcondor
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	117	(22:00) HV off	ISR	JRO Staff	Transmitters		new	2011-11-29T22:09:46-05:00	2012-10-03T14:47:41-05:00	Cae fuente de alta tensión (20 KV), se reestablece y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	116	(21:55) HV off	ISR	JRO Staff	Transmitters		new	2011-11-29T22:03:59-05:00	2012-10-03T14:47:54-05:00	Cae fuente de alta tensión (20 KV), se reestablece y todo funciona normalmente	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	115	Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-11-29T19:05:02-05:00	2012-10-03T14:48:21-05:00	"29 de Noviembre del 2011
08:00
Tx Fil Pot. Inc.
1 16.5 V 5 Kw
2 16.5 V 9 Kw
3 16.5 V 20 Kw
Votaje de Linea: 3860 VAC 
09:00
Tx Fil Pot. Inc.
1 16.5 V 5 Kw
2 16.5 V 9 Kw
3 16.5 V 20 Kw
Votaje de Linea: 3860 VAC 250 Kw
10:00
Tx Fil Pot. Inc.
1 16.5 V 4.5 Kw
2 16.5 V 8 Kw
3 16.5 V 18 Kw
Votaje de Linea: 3750 VAC 250 Kw
11:00
Tx Fil Pot. Inc.
1 16.5 V 5 Kw
2 16.5 V 9 Kw
3 16.5 V 20 Kw
Votaje de Linea: 3750 VAC 290 Kw
11:50
Falla Screen PA1
11:59
Falla Screen PA1
12:14
Tx Fil Pot. Inc.
1 16.5 V 5.5 Kw
2 16.5 V 9.5 Kw
3 16.5 V 22 Kw
Votaje de Linea: 3950 VAC 300 Kw
13:30
Tx Fil Pot. Inc.
1 16.5 V 5 Kw
2 16.5 V 8 Kw
3 16.5 V 18 Kw
14:00
Tx Fil Pot. Inc.
1 16.5 V 4.5 Kw
2 16.5 V 8 Kw
3 16.5 V 15 Kw
Votaje de Linea: 3800 VAC 280 Kw
15:00
Tx Fil Pot. Inc.
1 16.5 V 5 Kw
2 16.5 V 9 Kw
3 16.5 V 18 Kw
16:00
Tx Fil Pot. Inc.
1 16.5 V 5 Kw
2 16.5 V 8.5 Kw
3 16.5 V 18 Kw
Votaje de Linea: 3820 VAC 290 Kw
18:00
Tx Fil Pot. Inc.
1 16.5 V 6  Kw
2 16.5 V 11 Kw
3 16.5 V 18 Kw
Votaje de Linea: 4000 VAC 290 Kw
19:00
Tx Fil Pot. Inc.
1 16.5 V 6.5 Kw
2 16.5 V 11 Kw
3 16.5 V 22 Kw
Votaje de Linea: 4000 VAC 300 Kw

"	rtadeo
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	114	Lecturas de Potencia	ISR	JRO Staff	Transmitters		new	2011-11-29T07:17:49-05:00	2012-10-03T14:48:43-05:00	"28 de Noviembre del 2011
20:10
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       19  Kw
Votaje de Linea: 4050 VAC 295 Kw
21:00
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       19  Kw
Votaje de Linea: 4050 VAC 295 Kw
22:00
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       19  Kw
Votaje de Linea: 4050 VAC 295 Kw
23:00
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       19  Kw
Votaje de Linea: 4050 VAC 295 Kw

29 de Novimbre del 2011
00:00
Tx     Fil           Pot. Inc.
1      16.5 V        6  Kw
2      16.5 V        9  Kw
3      16.5 V       18  Kw
Votaje de Linea: 3850 VAC 285 Kw
01:00
Tx     Fil           Pot. Inc.
1      16.5 V        6  Kw
2      16.5 V       10  Kw
3      16.5 V       21  Kw
Votaje de Linea: 3950 VAC 290 Kw
02:00
Tx     Fil           Pot. Inc.
1      16.5 V        6  Kw
2      16.5 V       10  Kw
3      16.5 V       21  Kw
Votaje de Linea: 3850 VAC 285 Kw
03:00
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       21  Kw
Votaje de Linea: 4000 VAC 295 Kw
04:00
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       21  Kw
Votaje de Linea: 4000 VAC 295 Kw
05:00
Tx     Fil           Pot. Inc.
1      16.5 V        7  Kw
2      16.5 V       11  Kw
3      16.5 V       21  Kw
Votaje de Linea: 4000 VAC 295 Kw
06:00
Tx     Fil           Pot. Inc.
1      16.5 V        6  Kw
2      16.5 V       10  Kw
3      16.5 V       20  Kw
Votaje de Linea: 3850 VAC 290 Kw
07:00
Tx     Fil           Pot. Inc.
1      16.5 V        6  Kw
2      16.5 V       10  Kw
3      16.5 V       21  Kw
Votaje de Linea: 3950 VAC 295 Kw"	vquesada
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	113	06:00 Calibracion ATRs y TRs	ISR	JRO Staff	General		new	2011-11-29T07:13:45-05:00	2012-10-03T14:48:53-05:00		imanay
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	112	22: 46 Calibracion ATRs	ISR	JRO Staff	Spark Gaps		new	2011-11-28T22:50:15-05:00	2012-10-03T14:49:05-05:00		imanay
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	111	Cae screen PA TX1	ISR	JRO Staff	Transmitters		new	2011-11-28T21:09:59-05:00	2012-10-03T14:49:40-05:00	21:05 Cae fuente de screen PA TX1	vquesada
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	110	calibracion de chisperos	ISR	JRO Staff	General		new	2011-11-28T18:57:04-05:00	2012-10-03T14:49:50-05:00	18:52 horas	minonan
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	109	(17:48) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T17:57:57-05:00	2012-10-03T14:50:02-05:00	Cae fuente de Screen PA1, se reestablece y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	108	(17:30) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T17:52:22-05:00	2012-10-03T14:50:13-05:00	Cae fuente de Screen PA3, se reestablece y todo funciona normalmente	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	107	Calibracion de chisperos	ISR	JRO Staff	General		new	2011-11-28T15:58:10-05:00	2012-10-03T14:50:25-05:00	"Calibracion de chisperos
15:58 horas"	minonan
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	106	Reinicio de sistema de adquisicion	ISR	JRO Staff	Acquisition system		new	2011-11-28T15:55:56-05:00	2012-10-03T14:50:38-05:00	"Se reinicio la adquisicion del experimento EW-Drift debido a q se sospecho de una interferencia.
De 15:42 - 15:47 horas"	minonan
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	105	(14:45) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T15:00:58-05:00	2012-10-03T14:50:54-05:00	Cae fuente de alta tensión (Crowbar de protección) por presencia de transitorio. Se reestablece y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	104	(12:07) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T12:18:56-05:00	2012-10-03T14:51:09-05:00	Cae fuente Screen PA1, los problemas que se presentan son debido a fallas en los reles de control, los circuitos de control basados en logica de reles tiende a fallar por agotamiento de los elementos mecanicos de los reles que los componen, haciendo que por instantes algunos se desconecten haciendo fallar al sistema. Se reestablece y todo funciona normalmente	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	103	(11:54) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T12:06:18-05:00	2012-10-03T14:51:20-05:00	Cae fuente Screen PA1, fallan reles de control, se reestablece y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	102	calibracion de chisperos	ISR	JRO Staff	General		new	2011-11-28T12:03:45-05:00	2012-10-03T14:51:31-05:00	Calibracion de chisperos	minonan
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	101	(11:47) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T11:55:47-05:00	2012-10-03T14:52:43-05:00	Cae fuente Screen PA2, fallas en los reles de control. Se reestablece y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	100	(10.58) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T11:18:24-05:00	2012-10-03T14:52:09-05:00	Cae fuente de Screen PA1, se retiran indicadores luminosos para evitar sobrecarga de la fuente del circuito de control que ocasiona estas fallas. Se reestablece el transmisor y todo funciona normalmente.	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	99	(10:40) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T10:55:27-05:00	2012-10-03T14:53:07-05:00	Cae fuente Screen PA1, se reestablece y todo funciona normalmente	ryaya
Milestone 2011_11 1 ISCOD Campaign Nov 28 - Dic 01	98	(08:20) RF off	ISR	JRO Staff	Transmitters		new	2011-11-28T10:53:07-05:00	2012-10-03T14:53:22-05:00	Cae fuente de Screen PA2, se reestablece y todo funciona normalmente	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	97	14:30-16:30 Test de experimento EW DRIFT + FARADAY	ISR	Others	General	Rita Abad	new	2011-11-24T17:00:57-05:00	2012-10-03T14:56:03-05:00	"
- Test de ruído, con TXs.

  "	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	96	15:00 OFF TRANSMISORES	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T15:59:40-05:00	2012-10-03T14:56:35-05:00	SE APAGA TRANSMISORES TX1,TX2,TX3.	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	95	14:00 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T15:55:26-05:00	2012-10-03T14:56:52-05:00	"TX1: 8 KW
TX2: 10 KW
TX3: 15 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	94	13:00 Lectora de la Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T15:54:47-05:00	2012-10-03T14:57:09-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 15 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	93	12:00 Lectora de la Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T15:53:55-05:00	2012-10-03T14:57:19-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 16 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	92	11:20 Lectora de la Potencia-Linea de Voltaje	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T15:52:31-05:00	2012-10-03T14:57:29-05:00	"TX1: 7  KW
TX2: 10 KW
TX3: 14 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	91	10:00 Lectora de la Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T15:51:16-05:00	2012-10-03T14:57:42-05:00	"TX1: 7 KW
TX2: 10 KW
TX3: 14 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	90	15:00 FIN EW_DRIFT+FARADAY	ISR	Others	End experiment	Rita Abad	new	2011-09-23T15:01:20-05:00	2012-10-03T14:57:55-05:00	"FIN DE EXPERIMENTO EW_DRIFT+FARADAY
"	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	89	09:30 Lectora de la Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T09:47:24-05:00	2012-10-03T14:58:06-05:00	"TX1: 8 KW
TX2: 10 KW
TX3: 14 KW
"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	88	09:17 calibración del CHA  EW_DRIFT	ISR	Others	General	Rita Abad	new	2011-09-23T09:21:33-05:00	2012-10-03T14:58:17-05:00	Se calibra nuevamente el canal A de EW DRIFT, debido a que se fue la señal del canal.	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	87	8:40 calibracion de los ATRS yTRS	ISR	Others	Spark Gaps	waltter rojas	new	2011-09-23T08:46:03-05:00	2012-10-03T14:58:34-05:00	calibracion de los chisperos	dsuarez
Milestone 2011_09 ISCOD Campaign Sep 21-23	86	08:30 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-23T08:32:03-05:00	2012-10-03T14:58:50-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 16 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	85	07:10 Variación de la tensión de línea	ISR	JRO Staff	Transmitters		new	2011-09-23T07:10:08-05:00	2012-10-03T14:59:05-05:00	Gráfico de la variación de la tensión de línea del 22 al 23 de Setiembre	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	84	07:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T07:01:00-05:00	2012-10-03T14:59:15-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	83	06:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T06:09:49-05:00	2012-10-03T14:59:27-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	82	05:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T05:03:23-05:00	2012-10-03T14:59:41-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	81	04:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T04:04:17-05:00	2012-10-03T14:59:57-05:00	"TX1: 7 KW
TX2: 11 KW
TX3: 16 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	80	03:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T03:19:39-05:00	2012-10-03T15:00:10-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 16 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	79	02:40 Calibración de chisperos	ISR	JRO Staff	Antennas	Walter Alvarado	new	2011-09-23T02:45:13-05:00	2012-10-03T15:00:25-05:00	Calibración de chisperos ATRs y TRs.	dsuarez
Milestone 2011_09 ISCOD Campaign Sep 21-23	78	02:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T02:07:41-05:00	2012-10-03T15:00:34-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 16 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	77	01:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T01:27:39-05:00	2012-10-03T15:00:45-05:00	"TX1: 7 KW
TX2: 11 KW
TX3: 16 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	76	00:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-23T00:25:08-05:00	2012-10-03T15:00:55-05:00	"TX1: 8 KW
TX2: 11 KW
TX3: 16 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	75	00:00 Plots	ISR	JRO Staff	Plot	Daniel Suarez	new	2011-09-22T23:59:49-05:00	2012-10-03T15:01:06-05:00	Graficos del dia 22/09/2011	dsuarez
Milestone 2011_09 ISCOD Campaign Sep 21-23	74	23:30 Falla PA2	ISR	JRO Staff	Transmitters		new	2011-09-22T23:36:38-05:00	2012-10-03T15:01:28-05:00	Se deshabilita Screen PA2 por problemas de contacto en rele de control	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	73	23:15 Calibracion de Chisperos	ISR	JRO Staff	Antennas	Walter Alvarado	new	2011-09-22T23:17:00-05:00	2012-10-03T15:01:46-05:00	Se calibraron los chisperos ATRs y TRs	dsuarez
Milestone 2011_09 ISCOD Campaign Sep 21-23	72	23:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T23:07:53-05:00	2012-10-03T15:02:08-05:00	"TX1: 9 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	71	22:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T22:13:11-05:00	2012-10-03T15:02:20-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	70	21:30 Crowbar	ISR	JRO Staff	Transmitters		new	2011-09-22T21:37:59-05:00	2012-10-03T15:02:34-05:00	Falla fuente de 20 KV	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	69	21:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T21:08:22-05:00	2012-10-03T15:02:53-05:00	"TX1: 9 KW
TX2: 12 KW
TX3: 18 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	68	08:30 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T20:47:26-05:00	2012-10-03T15:03:06-05:00	"TX1: 9 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	67	19:00 Lectura de Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-22T19:01:07-05:00	2012-10-03T15:03:35-05:00	"TX1: 9 Kw
TX2: 13 Kw
TX3: 18 Kw
Voltaje de linea:4050 Vac
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	66	18:20 calibracion de chisperos atrs-trs	ISR	JRO Staff	General	jose lavado	new	2011-09-22T18:28:53-05:00	2012-10-03T15:03:50-05:00	calibracion de chisperos atrs-trs	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	65	18:00  Lectura de  Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-22T17:59:22-05:00	2012-10-03T15:04:48-05:00	"TX1:  9 Kw
TX2: 13 Kw
TX3: 18 Kw
Voltaje de linea:4050 Vac
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	64	17:00 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T17:07:10-05:00	2012-10-03T15:05:07-05:00	"TX1 8kw 
TX2 12kw 
TX3 16kw


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	63	17:00 falla de la fuente de alta	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T17:06:05-05:00	2012-10-03T15:05:18-05:00	"circuito crowbar

"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	62	16:20 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T16:27:35-05:00	2012-10-03T15:05:36-05:00	"TX1 7kw 
TX2 11kw 
TX3 15kw
"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	61	15:00 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T15:41:07-05:00	2012-10-03T15:05:51-05:00	"TX1 7kw 
TX2 11kw 
TX3 15kw
"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	60	14:05 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T15:39:26-05:00	2012-10-03T15:06:03-05:00	"TX1 6kw 
TX2 9kw 
TX3 14kw

"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	59	13:45 Se apaga la fuente de alta de los transmisores	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T15:35:41-05:00	2012-10-03T15:06:23-05:00	reparacion del techo de calamina en el cuarto de condensadores de la fuente de 20KVdc	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	58	15:02 Cayo Tx 1	ISR	Others	Transmitters	Rita Abad	new	2011-09-22T15:05:50-05:00	2012-10-03T15:06:37-05:00	Cayo Tx1	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	57	13:50 Se apaga transmisores	ISR	Others	Transmitters	Rita Abad	new	2011-09-22T14:01:54-05:00	2012-10-03T15:07:07-05:00	se apagan los transmisores debido a problemas externoa de mantenimiento del techo. 	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	56	13:30 Lectura de la Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T13:29:13-05:00	2012-10-03T15:07:31-05:00	"TX1 7kw 
TX2 11kw 
TX3 14kw
"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	55	12:20 calibracion de chisperos atrs -trs	ISR	Others	Spark Gaps	jose lavado	new	2011-09-22T12:26:25-05:00	2012-10-03T15:07:57-05:00	calibracion de chisperos atrs-trs	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	54	12:00 Lectura de la Potencia-Voltaje de Linea	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T12:02:04-05:00	2012-10-03T15:08:10-05:00	"TX1 8kw 3950VAC 3F
TX2 12kw 300kW
TX3 16kw


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	53	11:00 Lectura de la Potencia-Voltaje de Linea	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T11:11:13-05:00	2012-10-03T15:08:22-05:00	"TX1 6kw 3800VAC 3F
TX2 10kw 250kW
TX3 14kw


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	52	09:36 Faraday - Sistema de adquisicion pierde sincronizacion	ISR	Others	Acquisition system	Rita Abad	new	2011-09-22T10:14:27-05:00	2012-10-03T15:08:34-05:00	El sistema de adquisicion pierde sincronizacion, se reinicia el sistema - PC RADAR, Exp. Faraday.	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	51	10:00 Lectura de la Potencia-Voltaje de Linea	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T10:13:24-05:00	2012-10-03T15:09:00-05:00	"TX1 7kw  3850VAC 3F
TX2 10kw 285kW
TX3 15kw"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	50	09:00 Lectura de Potencia- Voltaje de Linea	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T09:07:34-05:00	2012-10-03T15:09:25-05:00	"TX1  7  KW   3850VAC 3 fases
TX2  11 KW   285KW
TX3  15 KW "	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	49	08:13 Lectura de Potencia	ISR	JRO Staff	Transmitters	rtadeo	new	2011-09-22T08:46:38-05:00	2012-10-03T15:09:38-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 16 KW


"	rtadeo
Milestone 2011_09 ISCOD Campaign Sep 21-23	48	08:33 calibracion de chisperos	ISR	JRO Staff	Spark Gaps	jose lavado	new	2011-09-22T08:44:14-05:00	2012-10-03T15:09:50-05:00	calibracion de chisperos atrs trs 	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	47	07:17 Variación de voltaje de línea	ISR	JRO Staff	Transmitters		new	2011-09-22T07:15:30-05:00	2012-10-03T15:10:08-05:00	Se muestra la variación referencial del voltaje de línea	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	46	07:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T07:10:30-05:00	2012-10-03T15:10:20-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	45	06:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T06:27:36-05:00	2012-10-03T15:10:31-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	44	05:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T05:13:08-05:00	2012-10-03T15:10:44-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	43	04:19 calibracion de los ATRS y TRS	ISR	JRO Staff	Spark Gaps	walter rojas	new	2011-09-22T04:19:42-05:00	2012-10-03T15:10:55-05:00		imanay
Milestone 2011_09 ISCOD Campaign Sep 21-23	42	04:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T03:58:30-05:00	2012-10-03T15:11:07-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	41	03:51 No ploteo en EW+Drifts	ISR	JRO Staff	Plot	I.Manay	new	2011-09-22T03:58:28-05:00	2012-10-03T15:11:21-05:00	El programa de ploteo muestra mensaje de error y pregunta si desea continuar con el archivo actual. Se hizo click en NO. Revisando los datos crudos en ARES si aparecen los archivos.	imanay
Milestone 2011_09 ISCOD Campaign Sep 21-23	40	03:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T02:59:12-05:00	2012-10-03T15:11:35-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	39	02:42 Crowbar	ISR	JRO Staff	Transmitters		new	2011-09-22T02:49:13-05:00	2012-10-03T15:11:52-05:00	Falla fuente 20KV-Crowbar	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	38	02:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T02:02:40-05:00	2012-10-03T15:12:04-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	37	01:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T00:58:40-05:00	2012-10-03T15:12:20-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	36	00:12 calibracion de los ATRS yTRS	ISR	JRO Staff	Spark Gaps	walter rojas	new	2011-09-22T00:12:22-05:00	2012-10-03T15:12:44-05:00		imanay
Milestone 2011_09 ISCOD Campaign Sep 21-23	35	00:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-22T00:12:10-05:00	2012-10-03T15:12:56-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	34	23:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-21T23:23:20-05:00	2012-10-03T15:13:20-05:00	"TX1: 8 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	33	10:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-21T22:35:39-05:00	2012-10-03T15:13:33-05:00	"TX1: 9 KW
TX2: 12 KW
TX3: 17 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	32	21:58 Crowbar	ISR	JRO Staff	Transmitters		new	2011-09-21T22:01:15-05:00	2012-10-03T15:13:42-05:00	Cae fuente 20 KV	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	31	21:00 Lectura de potencias	ISR	JRO Staff	Transmitters		new	2011-09-21T21:34:40-05:00	2012-10-03T15:13:55-05:00	"TX        Fil         Pot. Inc.
1         16.5v          9 KW
2         16.5v          13 KW
3         16.5v          18 KW"	ryaya
Milestone 2011_09 ISCOD Campaign Sep 21-23	30	21:20 Reinicio de adquisición de Faraday	ISR	JRO Staff	Acquisition system	I. Manay	new	2011-09-21T21:32:37-05:00	2012-10-03T15:14:08-05:00	"En archivos:
 d2011264149.r
 d2011264150.r
se observa pulso de transmisor en los 8 ultimos perfiles.

"	imanay
Milestone 2011_09 ISCOD Campaign Sep 21-23	29	20:38 calibración ATRs y TRs	ISR	JRO Staff	Spark Gaps	I.Manay	new	2011-09-21T20:50:52-05:00	2012-10-03T15:14:19-05:00		imanay
Milestone 2011_09 ISCOD Campaign Sep 21-23	28	19:40 cambio de turno	ISR	JRO Staff	Plot	I.Manay	new	2011-09-21T19:38:40-05:00	2012-10-03T15:14:31-05:00	"Se hace el cambio de turno con K.Kuyeng
Los graficos hasta ahora son los que se adjuntan."	imanay
Milestone 2011_09 ISCOD Campaign Sep 21-23	27	19:00 Lectura de Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T18:57:58-05:00	2012-10-03T15:14:44-05:00	"Lectura de Potencias
Tx1: 9 Kw
Tx2: 13 Kw
Tx3: 18 Kw
Voltaje de linea : 4000 VAC
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	26	18:00 Lectura de Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T18:02:33-05:00	2012-10-03T15:15:04-05:00	"Lectura de Potencias
Tx1: 9 Kw
Tx2: 13 Kw
Tx3: 18 Kw
Voltaje de linea : 4000 VAC
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	25	17:23 Problemas transmisores	ISR	Others	Transmitters	Rita Abad	new	2011-09-21T17:26:33-05:00	2012-10-03T15:15:17-05:00	Se cayeron las fuentes de TX1, TX2 y TX3.	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	24	17: 26 Crowbar	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T17:26:14-05:00	2012-10-03T15:15:28-05:00	Crowbar por caida d voltaje	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	23	17:00 Lectura de Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T17:09:05-05:00	2012-10-03T15:15:41-05:00	"Lectura de Potencias
Tx1: 9 Kw
Tx2: 12 Kw
Tx3: 17 Kw
Voltaje de linea : 4000 VAC
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	22	16:00  Lectura de  Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T16:09:17-05:00	2012-10-03T15:15:52-05:00	"Lectura de Potencias
Tx1: 9 Kw
Tx2: 12 Kw
Tx3: 17 Kw
Voltaje de linea : 4000 VAC
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	21	calibracion	ISR	Others	Spark Gaps	Jose Lavado	new	2011-09-21T15:10:33-05:00	2012-10-03T15:16:10-05:00	calibracion de chisperos de todos los ATrs y Trs.	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	20	14:10 Crowbar	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T14:14:44-05:00	2012-10-03T15:16:25-05:00	Crowbar por caida de voltaje	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	19	14:12 crowbar failure	ISR	Others	Transmitters	Rita Abad	new	2011-09-21T14:14:42-05:00	2012-10-03T15:16:41-05:00	Sobre carga, las fuentes de los tres transmisores cayeron. 	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	18	13:00 Lectura de Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T12:59:07-05:00	2012-10-03T15:16:50-05:00	"Lectura de Potencias
Tx1: 9 Kw
Tx2: 12 Kw
Tx3: 17 Kw
Voltaje de linea : 4000 VAC
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	17	12:08  Lectura de  Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T12:06:51-05:00	2012-10-03T15:17:02-05:00	"Lectura de Potencias
Tx1: 9 Kw
Tx2: 12 Kw
Tx3: 17 Kw
Voltaje de linea : 4000 VAC
Potencia de linea: 310 Kw"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	16	10:51 Problemas transmisores	ISR	Others	Transmitters	Rita Abad	new	2011-09-21T10:55:26-05:00	2012-10-03T15:17:14-05:00	Se cayeron los tres transmisores Tx1, Tx2 y Tx3, debido a un sobre voltaje.Afecta ambos experimentos EW_Drift+Faraday.	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	15	10:50 Crowbar	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T10:53:20-05:00	2012-10-03T15:17:46-05:00	Cae fuente de placa 20 Kv por caida de tension	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	14	10:43 ventilacion	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T10:43:08-05:00	2012-10-03T15:18:11-05:00	Se arranca ventilador derecho por que se incremente la temperatura en la sala de transmisores.	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	13	10:03 Problemas transmisores	ISR	Others	Transmitters	Rita Abad	new	2011-09-21T10:35:22-05:00	2012-10-03T15:18:22-05:00	Se cayo la fuente del Tx1,  el cual sale con el experimento FARADAY.	rabad
Milestone 2011_09 ISCOD Campaign Sep 21-23	12	09:00 Cambio de Tx Tomco	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T09:33:43-05:00	2012-10-03T15:18:34-05:00	"09:00 Se cambia Tx Tomco A (por que tiene muy baja salida) por el Tomco B
Lectura  de Potencias
Tx1: 8  Kw
Tx2: 11 Kw
Tx3: 15 Kw
Voltaje de linea : 3900 VAC
Potencia de linea:  290 Kw
"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	11	09:10 Calibración chisperos	ISR	JRO Staff	Spark Gaps	Jose Lavado	new	2011-09-21T09:24:00-05:00	2012-10-03T15:18:45-05:00	Se calibran los chisperos ATr y Tr	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	10	09:03 NUevo TOMCO para Tx3	ISR	JRO Staff	Transmitters	Karim Kuyeng	new	2011-09-21T09:19:03-05:00	2012-10-03T15:18:55-05:00	YA se cambio el TOMCO para el transmisor Tx3 y ahora se está obteniendo una mejor senhal como se muestra en el grafico adjunto	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	9	08:56 problemas con transmisor Tx3	ISR	JRO Staff	Transmitters	Karim Kuyeng	new	2011-09-21T09:17:10-05:00	2012-10-03T15:19:04-05:00	Se apaga el TOMCO para el Tx3 para cambiarlo por otro porque no está excitando mucho el driver y la potencia final está baja.	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	8	08:15  Lectura de  Potencias	ISR	JRO Staff	Transmitters	V. Quesada	new	2011-09-21T08:20:12-05:00	2012-10-03T15:19:15-05:00	"Tx1: 7  Kw
Tx2: 11 Kw
Tx3: 12 Kw
Voltaje de linea: 2900 VAC
Potencia de linea: 260 KW"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	7	07:30 Mediciones de Potencia	ISR	JRO Staff	Transmitters	V: Quesada	new	2011-09-21T07:49:29-05:00	2012-10-03T15:19:24-05:00	"Tx     Fil       Pot
1      16.5      8  Kw
2      16.5      12 Kw
3      16:5      12 Kw
Votaje de Linea:4000 VAC"	vquesada
Milestone 2011_09 ISCOD Campaign Sep 21-23	6	07:35 Inicio experimento	ISR	JRO Staff	Start experiment	Karim Kuyeng	new	2011-09-21T07:38:43-05:00	2012-10-03T15:19:33-05:00	"Luego de haber calibrado los canales de recepción se tienen las siguientes atenuaciones:

EW_Drift
A: 0dB (sin atenuador)
B: 0dB
C: 0dB (sin atenuador)
D: 0dB
E(Faraday A): 0dB
F (Faraday B): 2dB

Se inicia experimento"	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	5	07:35 sinc relojes de sistemas	ISR	JRO Staff	Acquisition system	Karim Kuyeng	new	2011-09-21T07:35:38-05:00	2012-10-03T15:19:53-05:00	Se sincronizan los relojes de los sistemas de adquisición con el reloj de la pc de procesamiento.	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	4	07:00  calibration start	ISR	JRO Staff	General	Karim Kuyeng	new	2011-09-21T07:34:48-05:00	2012-10-03T15:20:10-05:00	"Se prenden transmisores y se calibran los canales de recepción además de calibrar chisperos.

"	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	3	20set2011-20:30 Test	ISR	JRO Staff	End experiment	Karim Kuyeng	new	2011-09-21T06:36:13-05:00	2012-10-03T15:20:21-05:00	SE finaliza el test, pero se deja a los sistemas tomando ruido.	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	2	20set2011- Test	ISR	JRO Staff	Reception	Karim Kuyeng	new	2011-09-21T06:35:24-05:00	2012-10-03T15:20:32-05:00	"Se corrigen errores en la parte de recepci[on (conexión de cables intercambiados en Faraday y conexión de canales en las antenas de EW_Drift)
"	kkuyeng
Milestone 2011_09 ISCOD Campaign Sep 21-23	1	20set2011-19:14 Test	ISR	JRO Staff	Start experiment	Karim Kuyeng	new	2011-09-21T06:34:03-05:00	2012-10-03T15:20:42-05:00	Se inicia teste de experimento luego de problemas con el transmisor tx2.	kkuyeng
Milestone 	2077	20 Aug 19:55 Transmitter power measurements	ISR		Transmitters		new	2017-08-20T20:07:29-05:00	2017-08-20T20:07:29-05:00	"16:00 LV ON
16:18 HV ON
      TX#     Inc. Power
       1      +2.2 dBm
       3      +6.6 dBm
       4      +2.2/5.0 dBm
      Line Power: 4050 Vac @ 270KW
17:05 HV OFF (Antenna request)
17:20 HV ON
17:47 PA1 screen power supply alarm
18:00 D2 ON Ïmaging""
      TX#     Inc. Power
       1      +2.4 dBm
       3      +6.8 dBm
       4      +2.4 dBm
       D2     -7.0 dBm
19:00
      TX#     Inc. Power
       1      +2.5 dBm
       3      +6.8 dBm
       4      +2.6 dBm
       D2     -7.0 dBm


"	ryaya
Milestone 	2064	08 Jan 19:00 Transmitter Power Measuremen	ISR		Start experiment		new	2015-01-08T19:17:53-05:00	2015-01-08T19:17:53-05:00	"08:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
09:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
10:00 TX Power sample (-70 dB coupling)
Tx1 +4.0 dBm
Tx4 +4.0 dBm
Line voltage and power: 4050 VAC, 290 KW8
11:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
12:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
13:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
14:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4000 VAC, 290 KW8
15:00 TX Power sample (-70 dB coupling)
Tx1 +3.8 dBm
Tx4 +3.8 dBm
Line voltage and power: 4000 VAC, 290 KW8
16:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
17:00 HV OFF
17:07 HV ON
17:07 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
18:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
19:00 TX Power sample (-70 dB coupling)
Tx1 +3.9 dBm
Tx4 +3.9 dBm
Line voltage and power: 4050 VAC, 295 KW8
"	vquesada
Milestone 	1970	18 DEC 17:50 Faraday synchronized	ISR		Start experiment		new	2014-12-18T18:42:32-05:00	2014-12-18T18:42:32-05:00		dlume
Milestone 	1969	18 DEC 11:49 Faraday desynchronized	ISR		Start experiment		new	2014-12-18T18:41:07-05:00	2014-12-18T18:41:07-05:00		dlume
Milestone 	1968	18 DEC 17:37 Problems with channel A receiver	ISR		Start experiment		new	2014-12-18T18:39:53-05:00	2014-12-18T18:39:53-05:00		dlume
Milestone 	1967	18 DEC 17:35 transmitter falls	ISR		Start experiment		new	2014-12-18T18:37:07-05:00	2014-12-18T18:37:07-05:00		dlume
Milestone 	1966	18 DEC 17:28 Imaging experiment was started	ISR		Start experiment		new	2014-12-18T18:35:15-05:00	2014-12-18T18:35:15-05:00		dlume
Milestone 	1965	18 DEC 16:00 calibration of ATR and TR	ISR		Start experiment		new	2014-12-18T18:34:07-05:00	2014-12-18T18:34:07-05:00		dlume
Milestone 	1964	18 DEC 14:15 recovering transmission	ISR		Start experiment		new	2014-12-18T18:33:45-05:00	2014-12-18T18:33:45-05:00		dlume
Milestone 	1963	18 DEC 14:10 transmitter falls	ISR		Start experiment		new	2014-12-18T18:31:52-05:00	2014-12-18T18:31:52-05:00		dlume
Milestone 	1962	18 DEC 12:41 Restarted processing data PC (Faraday,EW_drift)	ISR		Start experiment		new	2014-12-18T18:30:15-05:00	2014-12-18T18:30:15-05:00		dlume
Milestone 	1961	18 DEC 12:30 calibration of ATR and TR	ISR		Start experiment		new	2014-12-18T18:29:34-05:00	2014-12-18T18:29:34-05:00		dlume
Milestone 	1960	18 DEC 12:25 Stopped processing data EW_drift and Faraday	ISR		Start experiment		new	2014-12-18T18:29:08-05:00	2014-12-18T18:29:08-05:00		dlume
Milestone 	1959	18 DEC 12:10 Restarted processing data PC (Faraday,EW_drift)	ISR		Start experiment		new	2014-12-18T18:28:35-05:00	2014-12-18T18:28:35-05:00		dlume
Milestone 	1958	18 DEC 12:04 Stopped processing data PC Faraday	ISR		Start experiment		new	2014-12-18T18:26:01-05:00	2014-12-18T18:26:01-05:00		dlume
Milestone 	1957	18 DEC 11:49 Faraday synchronized	ISR		Start experiment		new	2014-12-18T18:20:52-05:00	2014-12-18T18:20:52-05:00		dlume
Milestone 	1956	18 DEC 11:42 Faraday desynchronization	ISR		Start experiment		new	2014-12-18T18:19:22-05:00	2014-12-18T18:19:22-05:00		dlume
Milestone 	1955	18 DEC 11:33 Stopped processing data EW_drift	ISR		Start experiment		new	2014-12-18T18:16:29-05:00	2014-12-18T18:16:29-05:00		dlume
Milestone 	1954	18 DEC 09:00 Step moon	ISR		Start experiment		new	2014-12-18T18:12:21-05:00	2014-12-18T18:12:21-05:00		dlume
Milestone 	1953	18 DEC 08:40 TR change channel A	ISR		Start experiment		new	2014-12-18T18:06:50-05:00	2014-12-18T18:06:50-05:00		dlume
Milestone 	1952	18 DEC 08:30 calibration of ATR and TR	ISR		Start experiment		new	2014-12-18T18:05:41-05:00	2014-12-18T18:05:41-05:00		dlume
Milestone 	1951	18 DEC 08:30 TR change channel A	ISR		Start experiment		new	2014-12-18T18:03:45-05:00	2014-12-18T18:03:45-05:00		dlume
Milestone 	1910	16 Dec 08:00 Operation Time	ISR		General	P. Condor	new	2014-12-16T08:10:46-05:00	2014-12-16T08:10:46-05:00	"EW_Drift Farday Imaging
P Condor
1) !9:50-07:50
2) T operation 12 h
3 T stop         --"	pcondor
Milestone 	1700	22  September 19:15 Transmitter Power Measurements	ISR		Start experiment		new	2014-09-22T16:30:38-05:00	2014-09-22T16:30:38-05:00	"22  September 2014
14:55 LV ON
15:30 HV ON
15:50 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.4, 5.5 dBm
Tx4 +2.2 dBm
Line voltage and power: 4070 VAC, 320 KW
16:30 TX Power sample (-70 dB coupling)
Tx1 +5.7 dBm
Tx2 +2.4, 5.5 dBm
Tx4 +2.2 dBm
Line voltage and power: 4070 VAC, 320 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 +5.5 dBm
Tx2 +2.5, 5.5 dBm
Tx4 +2.0 dBm
Line voltage and power: 4050 VAC, 320 KW
17:45 TX Power sample (-70 dB coupling)
Tx1 +5.6 dBm
Tx2 +2.5 dBm
Tx4 +2.2 dBm
D3 -8.6 dbm
Line voltage and power: 4100 VAC, 320 KW
19:00 TX Power sample (-70 dB coupling)
Driver 3 ON (D3)
Tx1 +5.6 dBm
Tx2 +2.5 dBm
Tx4 +2.3 dBm
D3 -8.6 dbm
Line voltage and power: 4100 VAC, 320 KW"	vquesada
Milestone 	1649	22 Jul 19:06 Spark gaps adjusment	ISR		Spark Gaps	wrojas	new	2014-07-21T23:40:27-05:00	2014-07-21T23:40:27-05:00		imanay
Milestone 	1438	03 Apr 07:10 Transmitter Power measurements	ISR		Transmitters		new	2014-04-03T04:27:21-05:00	2014-04-03T04:27:21-05:00	07:07 Crowbar by voltage drop.	vquesada
Milestone 	1268	23 Ene 12:05 Subio la coherencia de los canales Ay B	ISR		Process/Analysis Program	DCordova	new	2014-01-23T18:27:00-05:00	2014-01-23T18:27:00-05:00	"Sube la coherencia de A y  B esto se debio al paso del sol por uno de los lobulos laterales del haz de la antena
El efecto duro hasta las 12:25"	dcordova
Milestone 	1235	22 Enero 2014-07:05 Lectura de Potencias	ISR		Start experiment		new	2014-01-22T07:49:11-05:00	2014-01-22T07:49:11-05:00	"22 de Enero 2014
00:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.3 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 310 Kw
01:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.3 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 310 Kw
02:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.3 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 310 Kw
03:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.3 dBm 
Tx4: +1.7 dBm
Voltaje de linea:3950 Vac, 310 Kw
04:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.2 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3880 Vac, 300 Kw
05:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.2 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3880 Vac, 300 Kw
06:00
Tx1: +6.3 dBm
Tx2: +2.1 dBm/+5.1 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3880 Vac, 300 Kw
07:00
Tx1: +6.3 dBm
Tx2: +2.3 dBm/+5.2 dBm 
Tx4: +1.5 dBm
Voltaje de linea:3880 Vac, 300 Kw"	vquesada
Milestone 	1196	09 Ene 18:20 Calibracion de las ATRS y TRS	ISR		Antennas		new	2014-01-09T20:29:21-05:00	2014-01-09T20:29:21-05:00		dcordova
Milestone 	1195	15:54 Se prende el sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:28:53-05:00	2014-01-09T20:28:53-05:00	Disminuye la presencia de picos. Se aprecian colas en el electrochorro	dcordova
Milestone 	1194	09 Ene 15:29 Se apaga el sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:27:36-05:00	2014-01-09T20:27:36-05:00	Aun se aprecia la presencia de picos.	dcordova
Milestone 	1193	09 Ene 15:24 Se prende el sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:26:39-05:00	2014-01-09T20:26:39-05:00		dcordova
Milestone 	1192	09 Ene 15:08 Se apaga sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:26:05-05:00	2014-01-09T20:26:05-05:00	Siguen presentes los picos causados por JARS. Se cambia de modulo JARS	dcordova
Milestone 	1191	09 Ene 15:05 Se prende el sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:25:08-05:00	2014-01-09T20:25:08-05:00		dcordova
Milestone 	1190	09 Ene 15:00 Calibracion de ATRS y TRS	ISR		Antennas		new	2014-01-09T20:24:25-05:00	2014-01-09T20:24:25-05:00		dcordova
Milestone 	1189	09 Ene 14:58 Se apaga el sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:23:29-05:00	2014-01-09T20:23:29-05:00	Picos producidos por el sistema JARS	dcordova
Milestone 	1188	09 Ene 14:20 Aparecen interferencias en los espectros	ISR		Plot		new	2014-01-09T20:20:50-05:00	2014-01-09T20:20:50-05:00		dcordova
Milestone 	1187	09 Ene 12:00 Calibracion de ATRS y TRS	ISR		Antennas		new	2014-01-09T20:14:57-05:00	2014-01-09T20:14:57-05:00		dcordova
Milestone 	1186	09 Ene 11:27 Se reinicia el sistema de adquisicion	ISR		Acquisition system		new	2014-01-09T20:13:18-05:00	2014-01-09T20:13:18-05:00		dcordova
Milestone 	1185	09 Ene 09:40 El canal 4 presenta un ruido menor	ISR		Plot		new	2014-01-09T20:12:36-05:00	2014-01-09T20:12:36-05:00		dcordova
Milestone 	1184	09 Ene 09:00 Calibracion de ATRS y TRS	ISR		Antennas		new	2014-01-09T20:11:25-05:00	2014-01-09T20:11:25-05:00		dcordova
Milestone 	1183	09 Ene 08:40 Se deshabilito el envio FTP para ISR, MST y EEJ	ISR		Plot		new	2014-01-09T19:07:53-05:00	2014-01-09T19:07:53-05:00		dcordova
Milestone 	1102	29 Oct 14:35 Lectura de Potencia	ISR		Transmitters		new	2013-10-30T13:31:12-05:00	2013-10-30T13:31:12-05:00	"30 de Octubre del 2013
05:30 LV  ON
05:50 HV  ON
06:05
Tx1: 13 Kw
Tx3: 18 Kw
Votaje de Linea: 4000 VAC 290Kw
06:15
Tx1: 16 Kw <>+2.0 dBm
Tx3: 20 Kw <>+2.1 dBm
Votaje de Linea: 4000 VAC, 290 Kw
07:00
Tx1: 19 Kw <>+2.7 dBm
Tx3: 22 Kw <>+2.7 dBm
Votaje de Linea: 4000 VAC, 290 Kw
08:00
Tx1: 19 Kw <>+2.7 dBm
Tx3: 22 Kw <>+2.7 dBm
Votaje de Linea: 3900 VAC, 290 Kw
09:00
Tx1: 19 Kw 
Tx3: 29 Kw
Votaje de Linea: 3900 VAC, 290 Kw
10:00
Tx1: 16 Kw <>+2.3 dBm
Tx3: 21 Kw <>+2.3 dBm
Votaje de Linea: 3900 VAC, 290 Kw
11:00
Tx1: 17 Kw 
Tx3: 21 Kw 
Votaje de Linea: 3900 VAC, 290 Kw
12:00
Tx1: 18 Kw <>+2.7 dBm
Tx3: 22 Kw <>+2.7 dBm
Votaje de Linea: 3900 VAC, 290 Kw
13:00
Tx1: 16 Kw 
Tx3: 20 Kw 
Votaje de Linea: 3900 VAC, 290 Kw
14:00
Tx1: 16 Kw <>+2.5 dBm
Tx3: 21 Kw <>+2.5 dBm
Votaje de Linea: 3900 VAC, 290 Kw
"	vquesada
Milestone 	1008	12 Sep 13:45 Lectura de Potencia	ISR		Start experiment		new	2013-09-12T14:08:16-05:00	2013-09-12T14:08:16-05:00	"12:00
Tx1: 36 Kw
Tx3: 4 Kw
3850 Vac, 295 Kw
13:00
Tx1: 36 Kw
Tx3: 4 Kw
3850 Vac, 295 Kw
13:45 HV OFF
14:00 LV OFF"	vquesada
Milestone 	953	Lectura de potencias	ISR		Start experiment		new	2013-09-09T23:29:43-05:00	2013-09-09T23:29:43-05:00	"09 Set 2013
22:00 
Tx1 40 Kw
Tx3 4.5 Kw
4000VAC 300Kw
23:00 
Tx1 40 Kw
Tx3 4.5 Kw
4000VAC 300Kw"	vquesada