Opened 2 years ago
#901 new Transmitter
11 03 19:00 Transmitter Report
Reported by: | vquesada | Owned by: | vquesada |
---|---|---|---|
Priority: | normal | Milestone: | 2022_11 HAD |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
08:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.5 Vpp
Line Voltage 4080 VAC, 350 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.5 Vpp
Line Voltage 4080 VAC, 350 KW
09:39 Crowbar
10:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.5 Vpp
Line Voltage 4080 VAC, 350 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.5 Vpp
Line Voltage 4080 VAC, 350 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.5 Vpp
Line Voltage 4080 VAC, 350 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.5 Vpp
Line Voltage 4080 VAC, 350 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.4 Vpp
Line Voltage 4050 VAC, 350 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.4 Vpp
Line Voltage 4050 VAC, 350 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.4 Vpp
Line Voltage 4050 VAC, 350 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.4 Vpp
Line Voltage 4050 VAC, 350 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.4 Vpp
Line Voltage 4050 VAC, 350 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.4 Vpp
Line Voltage 4050 VAC, 350 KW