﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
781	06 21 19:30 Transmitter report	ryaya	somebody	"08:40 HV ON
09:00 ATRAD 1, 2 ON (Oblique)
09:00 TX Power Sample (-70 dB coupling)
TX3 5.1 Vpp
TX4 5.0 Vpp
Line Voltage 4090 VAC, 290 KW
10:00 TX Power Sample (-70 dB coupling)
TX3 5.1 Vpp
TX4 5.2 Vpp
Line Voltage 4090 VAC, 300 KW
11:00 TX Power Sample (-70 dB coupling)
TX3 5.0 Vpp
TX4 5.2 Vpp
Line Voltage 4080 VAC, 300 KW
12:00 TX Power Sample (-70 dB coupling)
TX3 5.0 Vpp
TX4 5.2 Vpp
Line Voltage 4080 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX3 4.9 Vpp
TX4 5.2 Vpp
Line Voltage 4080 VAC, 300 KW
15:00 TX Power Sample (-70 dB coupling)
TX3 4.9 Vpp
TX4 5.2 Vpp
Line Voltage 4080 VAC, 300 KW
16:00 ATRAD 1, 2 OFF
16:00 TX Power Sample (-70 dB coupling)
TX3 4.9 Vpp
TX4 5.2 Vpp
Line Voltage 4060 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX3 4.9 Vpp
TX4 5.2 Vpp
Line Voltage 4060 VAC, 300 KW
17:40 ATRAD 1, 2 ON
18:00 TX Power Sample (-70 dB coupling)
TX3 4.8 Vpp
TX4 5.2 Vpp
Line Voltage 4060 VAC, 300 KW
19:00 TX Power Sample (-70 dB coupling)
TX3 4.8 Vpp
TX4 5.2 Vpp
Line Voltage 4030 VAC, 300 KW

"	Transmitter	new	normal	2022_06 ISCOD (EWDrift+Oblique+150km)	ISR				