﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
58	01 08 07:15 Transmitter report	ctipacti	somebody	"'''07/01/21'''

20:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW

'''08/01/21'''

00:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 6.10 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4100 VAC, 290 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 6.10 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4000 VAC, 290 KW"	Transmitter	new	normal	2021 ISCOD (ISR+Imaging)	ISR+Imaging				