Opened 3 years ago

#561 new Transmitter

11 04 19:18 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2021_11 MRI Drifts + MST
Component: ISR Version:
Keywords: Cc:

Description

08:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 310 KW
08:19 HV OFF (Dipole repair)
08:41 HV ON
09:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 310 KW
09:25 Power Outage
12:52 LV ON
13:07 HV ON
13:20 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX4 5.3 Vpp
Line Voltage 4000 VAC, 310 KW
13:35 PA1 Screen power supply failure
14:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX4 5.3 Vpp
Line Voltage 4050 VAC, 320 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 320 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 320 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 320 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 320 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4050 VAC, 320 KW

Change History (0)

Note: See TracTickets for help on using tickets.