Opened 3 years ago
Last modified 3 years ago
#539 new Transmitter
11 01 19:38 Transmitter report
Reported by: | rtadeo | Owned by: | somebody |
---|---|---|---|
Priority: | normal | Milestone: | 2021_10 COSMIC |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
01/11/2021
08:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.9 Vpp
Line Voltage 4100 VAC, 250 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.9 Vpp
Line Voltage 4080 VAC, 250 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.9 Vpp
Line Voltage 4080 VAC, 250 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 250 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 250 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 250 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.4 Vpp
Line Voltage 4050 VAC, 250 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
The attenuation of the samples in all cases is 73dB of coupling.