Opened 3 years ago

#533 new Transmitter

11 01 07:15 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2021_10 COSMIC
Component: ISR Version:
Keywords: Cc:

Description

31/10/2021

20:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
20:56 CROWBAR
21:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4080 VAC, 250 KW

01/11/2021

00:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4080 VAC, 250 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
01:36 CROWBAR
02:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.8 Vpp
Line Voltage 4080 VAC, 300 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 4.2 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 250 KW