﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
486	10 27 19:00 Transmitter Report	vquesada	vquesada	"07:50 LV ON
07:57 HV ON
08:10 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp -- with splitter
TX3 4.1 Vpp -- with splitter
Line Voltage 4100 VAC, 270 KW
09:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.1 Vpp 
Line Voltage 4100 VAC, 270 KW
'''Tx1''
Incident:+6.5 dBm --1.1 MW
Reflected: -11.8 dBm
'''T3'''
Incident:-2.5 dBm --1.2 MW
Reflected: -13.0 dBm
10:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
10:20 HV OFF
11:00 HV ON
11:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.1 Vpp 
Line Voltage 4080 VAC, 270 KW
12:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
13:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
14:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
15:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
16:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
17:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
18:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
19:00 TX Power Sample (-70 dB Coupling)
TX1 4.3 Vpp 
TX3 4.2 Vpp 
Line Voltage 4080 VAC, 270 KW
"	Transmitter	new	normal	2021_10 SOLAR	ISR				