Opened 3 years ago
#451 new Transmitter
10 18 20:00 Transmitter Report
Reported by: | rtadeo | Owned by: | somebody |
---|---|---|---|
Priority: | normal | Milestone: | 2021_10 HAE |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
10:45 HV ON
10:46 RF ON
11:04:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.5 Vpp
Line Voltage 4050 VAC, 250 KW
11:30 RF OFF and HV OFF
11:30 Failure of the Atrad2, it is exchanged for the Atrad1
11:30 Atrad4 control alarm, it is changed to the Atrad3.
12:20 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp (5.6dBm)
TX3 5.7 Vpp (5.7dBm)
Line Voltage 4050 VAC, 300 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4050 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4050 VAC, 300 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 300 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 6.0 Vpp
Line Voltage 4050 VAC, 300 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.8 Vpp
Line Voltage 4060 VAC, 300 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.9 Vpp
Line Voltage 4060 VAC, 300 KW
20:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.9 Vpp
Line Voltage 4060 VAC, 300 KW