Opened 4 years ago

#42 new Transmitter

01 06 19:30 Transmitter report

Reported by: ryaya Owned by: somebody
Priority: normal Milestone: 2021 ISCOD (ISR+Imaging)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

08:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 5.90 Vpp
TX4 5.90 Vpp
Line Voltage 4050 VAC, 280 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Line Voltage 4020 VAC, 290 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.80 Vpp
Line Voltage 4050 VAC, 290 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.80 Vpp
Line Voltage 4020 VAC, 290 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 6.00 Vpp
TX4 6.10 Vpp
Line Voltage 4120 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.80 Vpp
Line Voltage 4020 VAC, 290 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 6.10 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
Line Voltage 4100 VAC, 290 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
Line Voltage 4100 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 6.10 Vpp
TX3 6.00 Vpp
TX4 6.00 Vpp
Line Voltage 4100 VAC, 300 KW
17:35 D2 ON "IMAGING"
18:00 TX Power Sample (-70 dB coupling)
TX1 6.10 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
D2 1.30 Vpp
Line Voltage 4100 VAC, 290 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 6.10 Vpp
TX3 5.90 Vpp
TX4 6.00 Vpp
D2 1.30 Vpp
Line Voltage 4100 VAC, 290 KW

Change History (0)