Opened 4 years ago

#37 new Transmitter

01 06 07:15 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2021 ISCOD (ISR+Imaging)
Component: ISR+Imaging Version: 1.0
Keywords: Cc:

Description

20:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 6.00 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4120 VAC, 280 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 6.00 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4120 VAC, 280 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 6.00 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4120 VAC, 280 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 6.20 Vpp
TX3 6.00 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4120 VAC, 280 KW
00:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4010 VAC, 280 KW
06:05 OFF Imaging
07:00 TX Power Sample (-70 dB coupling)
TX1 6.00 Vpp
TX3 5.80 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 280 KW