﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
356	09 22 07:30 Transmitter report	ryaya	somebody	"21/09/2021

21:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4050 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.7 Vpp
TX4 5.8 Vpp
D2  1.3 Vpp 
Line Voltage 4080 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4050 VAC, 290 KW

22/09/2021

00:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4050 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4060 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4080 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4060 VAC, 290 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4050 VAC, 290 KW
04:12 CROWBAR
04:20 Exchanger 2 turned off
05:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp 
Line Voltage 4050 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
TX4 5.6 Vpp
D2  turned off 
Line Voltage 4030 VAC, 290 KW
07:00 PA 1 control failure
07:40 PA 1 control failure"	Transmitter	new	normal	2021_09 ISCOD + AFOSR	ISR+Imaging				