﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
318	08 23 19:40 Transmitter report	rtadeo	somebody	"14:30 LV ON
15:30 HV ON
16:00 TX Power Sample (-70 dB coupling)
TX1 3.70 Vpp
TX4 3.50 Vpp
Line Voltage 4050 VAC, 240 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 3.60 Vpp
TX4 3.40 Vpp
Line Voltage 4050 VAC, 240 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 3.70 Vpp
TX4 3.40 Vpp
Line Voltage 4000 VAC, 220 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 3.70 Vpp
TX4 3.40 Vpp
Line Voltage 4000 VAC, 220 KW
"	Transmitter	new	normal	2021_08 MLT	ISR				