Opened 3 years ago

#318 new Transmitter

08 23 19:40 Transmitter report

Reported by: rtadeo Owned by: somebody
Priority: normal Milestone: 2021_08 MLT
Component: ISR Version:
Keywords: Cc:

Description

14:30 LV ON
15:30 HV ON
16:00 TX Power Sample (-70 dB coupling)
TX1 3.70 Vpp
TX4 3.50 Vpp
Line Voltage 4050 VAC, 240 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 3.60 Vpp
TX4 3.40 Vpp
Line Voltage 4050 VAC, 240 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 3.70 Vpp
TX4 3.40 Vpp
Line Voltage 4000 VAC, 220 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 3.70 Vpp
TX4 3.40 Vpp
Line Voltage 4000 VAC, 220 KW