307	06 26 16:00 Transmitter report	rtadeo	somebody	"08:00 LV ON
08:10 HV ON
08:30 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX4 5.60 Vpp
Line Voltage 4000 VAC, 300 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX4 5.60 Vpp
Line Voltage 4000 VAC, 300 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX4 5.60 Vpp
Line Voltage 4000 VAC, 300 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX4 5.60 Vpp
Line Voltage 4000 VAC, 300 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX4 5.70 Vpp
Line Voltage 4000 VAC, 310 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX4 5.70 Vpp
Line Voltage 4000 VAC, 310 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX4 5.70 Vpp
Line Voltage 4000 VAC, 310 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX4 5.60 Vpp
Line Voltage 4000 VAC, 300 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX4 5.60 Vpp
Line Voltage 4000 VAC, 300 KW
16:01 OFF TX "	Transmitter	new	normal	2021_06 EWDrifts + Oblique	ISR				