2634	08 18 19:00 Transmitter report	rtadeo	somebody	"
07:50 LV ON
08:05 Test Faraday
11:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
11:30 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
11:59 Off Screen PA1
12:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
14:40 ABS Mismatch
15:20 RF ON
15:20 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
16:19 ABS MISMATCH
16:33 RF ON
17:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 270 KW

"	Start Experiment	new	normal	2026_08 All ISR (DP+EWDrifts)	ISR				