﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2608	08 11 20:00 Transmitter report	ctipacti	somebody	"07:50 LV ON
08:25 HV ON
08:43 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
Line Voltage 4020 VAC, 290 KW
09:11 RF OFF (Acquisition restart)
09:28 RF ON 
10:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
Line Voltage 4020 VAC, 190 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
Line Voltage 4020 VAC, 190 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.6 Vpp
Line Voltage 4020 VAC, 280 KW
12:04 Crowbar
12:28 RF OFF (acquisition restart)
12:30 RF ON
12:40 Crowbar
13:25 Crowbar
13:37 RF ON (Only Imaging)
13:51 PA1 Screen power supply failure
14:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4050 VAC, 190 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4050 VAC, 190 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4070 VAC, 190 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4070 VAC, 190 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4050 VAC, 190 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
Line Voltage 4050 VAC, 190 KW"	Transmitter	new	normal	2026_08 ISCOD (Perseids)	ISR				