﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2532	05 28 07:30 Transmitter report	rtadeo	somebody	"20:00 TX Power Sample (-70 dB coupling)
TX3 5.2 Vpp
TX4 5.2 Vpp
Line Voltage 4100 VAC, 220 KW
21:00 TX Power Sample (-70 dB coupling)
TX3 5.2 Vpp
TX4 5.2 Vpp
Line Voltage 4100 VAC, 220 KW
22:00 TX Power Sample (-70 dB coupling)
TX3 5.2 Vpp
TX4 5.2 Vpp
Line Voltage 4100 VAC, 220 KW
23:00 TX Power Sample (-70 dB coupling)
TX3 5.2 Vpp
TX4 5.2 Vpp
Line Voltage 4100 VAC, 220 KW
00:00 TX Power Sample (-70 dB coupling)
TX3 5.2 Vpp
TX4 5.2 Vpp
Line Voltage 4100 VAC, 220 KW
00:30 RF: OFF - Clock Master failure
00:45 Crowbar HV
02:37 RF:ON 
02:40 TX Power Sample (-70 dB coupling)
TX3 5.3 Vpp
TX4 5.3 Vpp
Line Voltage 4150 VAC, 280 KW
03:00 TX Power Sample (-70 dB coupling)
TX3 5.3 Vpp
TX4 5.3 Vpp
Line Voltage 4150 VAC, 280 KW
03:30 RF : OFF - PA3: Crowbar circuit  failure
03:57 RF : ON
04:00 TX Power Sample (-70 dB coupling)
TX3 5.3 Vpp
TX4 5.3 Vpp
Line Voltage 4150 VAC, 280 KW
05:00 TX Power Sample (-70 dB coupling)
TX3 5.3 Vpp
TX4 5.3 Vpp
Line Voltage 4150 VAC, 280 KW
06:00 TX Power Sample (-70 dB coupling)
TX3 5.3 Vpp
TX4 5.3 Vpp
Line Voltage 4150 VAC, 280 KW
07:00 TX Power Sample (-70 dB coupling)
TX3 5.3 Vpp
TX4 5.3 Vpp
Line Voltage 4150 VAC, 280 KW



"	Transmitter	new	normal	2026_05 ISCOD CONGS-26	ISR				