Opened 4 years ago

Last modified 4 years ago

#241 new Transmitter

06 09 06:00 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2021_06 HAE
Component: ISR Version:
Keywords: Cc:

Description

08/06/2021

17:20 LV ON
17:57 HV ON
18:30 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
19:48 PA1 Screen Power Supply Failure
20:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW

09/06/2021

00:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.30 Vpp
Line Voltage 4020 VAC, 290 KW
02:15 CROWBAR
03:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.40 Vpp
Line Voltage 4050 VAC, 290 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.40 Vpp
Line Voltage 4050 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.40 Vpp
Line Voltage 4050 VAC, 290 KW
05:53 HV OFF
06:10 LV OFF

Change History (1)

comment:1 Changed 4 years ago by ctipacti

  • Milestone set to 2021_06 HAE
Note: See TracTickets for help on using tickets.