﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2341	02 13 19:30 Transmitter report	ryaya	somebody	"07:50 LV ON
08:06 HV ON
08:50 TX Power Sample (-73 dB coupling)
TX3 3.7 Vpp
TX4 3.7 Vpp
Line Voltage 4060 VAC, 280 KW
10:00 TX Power Sample (-73 dB coupling)
TX3 3.7 Vpp
TX4 3.7 Vpp
11:00 TX Power Sample (-73 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4000 VAC, 280 KW
12:00 TX Power Sample (-73 dB coupling)
TX3 3.7 Vpp
TX4 3.7 Vpp
13:45 Problem with the high-pressure pump. Replacement procedure conducted.
16:20 LV ON
16:35 HV ON
16:54 TX Power Sample (-73 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4060 VAC, 280 KW
18:00 TX Power Sample (-73 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
19:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4080 VAC, 280 KW
"	Transmitter	new	normal	2026_01 ISCOD Polar Vortex (All ISR)	ISR				