2329	11 13 07:12 Transmitter report	ryaya	somebody	"12/11/25

21:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.7 Vpp
Line Voltage 4000 VAC, 250 KW
22:00 TX Power Sample (-73 dB coupling)
TX3 3.5 Vpp
TX4 3.7 Vpp
Line Voltage 4050 VAC, 250 KW
23:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4100 VAC, 250 KW

13/11/25

00:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4100 VAC, 250 KW
01:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
02:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
03:10 TX Power Sample (-73 dB coupling)
TX3 3.7 Vpp
TX4 3.7 Vpp
Line Voltage 4050 VAC, 250 KW
04:00 TX Power Sample (-73 dB coupling)
TX3 3.7 Vpp
TX4 3.7 Vpp
Line Voltage 4080 VAC, 250 KW
05:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4050 VAC, 250 KW
06:00 TX Power Sample (-73 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4050 VAC, 250 KW
07:00 TX Power Sample (-73 dB coupling)
TX3 3.8 Vpp
TX4 3.8 Vpp
Line Voltage 4050 VAC, 250 KW"	Transmitter	new	normal	2025_11 All ISR	ISR				