﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2324	11 12 19:00 Transmitter Report	vquesada	somebody	"08:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4050 VAC, 260 KW
09:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.9 Vpp
Line Voltage 4100 VAC, 270 KW
10:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.9 Vpp
Line Voltage 4100 VAC, 270 KW
11:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.9 Vpp
Line Voltage 4100 VAC, 270 KW
12:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4100 VAC, 270 KW
13:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4100 VAC, 270 KW
14:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4100 VAC, 270 KW
14:25 ABS failure
15:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4100 VAC, 270 KW
16:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4100 VAC, 270 KW
17:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4100 VAC, 270 KW
18:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4080 VAC, 270 KW
18:40 ABS failure
      HV OFF
18:53 HV ON
19:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4080 VAC, 270 KW










"	Transmitter	new	normal	2025_11 All ISR	ISR				