﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2293	11 07 19:31 Transmitter report	ctipacti	somebody	"08:00 TX Power Sample (-70 dB coupling)
TX1 4.0 Vpp
TX3 3.9 Vpp
Line Voltage 4000 VAC, 270 KW
08:39 PA1 screen power suppl failure
09:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 260 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 260 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 260 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.9 Vpp
Line Voltage 4070 VAC, 290 KW
12:45 TX1 Failure - Change to TX4
13:25 TX ON
14:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.6 Vpp
Line Voltage 4100 VAC, 260 KW
15:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.6 Vpp
Line Voltage 4050 VAC, 260 KW
15:45 TX OFF - Spark gap replacement
16:55 TX ON
17:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.6 Vpp
Line Voltage 4050 VAC, 260 KW
18:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.6 Vpp
Line Voltage 4050 VAC, 260 KW
19:00 TX Power Sample (-70 dB coupling)
TX3 3.7 Vpp
TX4 3.6 Vpp
Line Voltage 4050 VAC, 260 KW"	Transmitter	new	normal	2025_11 All ISR	ISR				