Opened 7 hours ago
#2288 new Transmitter
11 07 07:25 Transmitter report
| Reported by: | rtadeo | Owned by: | somebody |
|---|---|---|---|
| Priority: | normal | Milestone: | 2025_11 All ISR |
| Component: | ISR | Version: | |
| Keywords: | Cc: |
Description
20:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 4.0 Vpp
Line Voltage 4100 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 4.0 Vpp
Line Voltage 4100 VAC, 290 KW
21:04 RF OFF (ALARM ABS)
21:07 RF ON
21:30 RF OFF/ON (ALARM ABS)
21:31 RF OFF (ALARM ABS)
21:32 RF ON
21:42 RF OFF
21:44 TX OFF (REPLACEMENT OF CONTROL CARD AND FIBER OPTIC CONVERTER)
22:19 TX ON
23:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 4.0 Vpp
Line Voltage 4000 VAC, 290 KW
00:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 4.0 Vpp
Line Voltage 4000 VAC, 290 KW
00:20 RF OFF/ON (ALARM ABS)
00:59 RF OFF (ALARM ABS)
01:01 RF ON
01:05 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.8 Vpp
Line Voltage 4000 VAC, 290 KW
01:50 TX OFF (ALARM ABS:FIBER OPTIC CONVERTER REPLACEMENT)
02:05 TX ON
02:05 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.8 Vpp
Line Voltage 4000 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.8 Vpp
Line Voltage 4000 VAC, 290 KW
03:42 RF OFF (ALARM ABS)
03:45 RF ON
04:00 TX Power Sample (-70 dB coupling)
TX1 3.9 Vpp
TX3 3.8 Vpp
Line Voltage 4000 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 4.0 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 4.0 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 290 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 4.0 Vpp
TX3 3.9 Vpp
Line Voltage 4050 VAC, 290 KW