﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2132	07 30 19:00 Transmitter Report	vquesada	somebody	"09:30  LV  ON
09:50  HV  ON
10:00 TX Power Sample (-70 dB coupling)
TX3 5.1, 3.6 Vpp
TX4 5.0, 3.7 Vpp
Line Voltage 4060 VAC, 260 KW
11:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4060 VAC, 260 KW
12:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4060 VAC, 260 KW
13:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4060 VAC, 260 KW
14:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.7 Vpp
Line Voltage 4060 VAC, 260 KW
14:20 ATRAD 3 and 4 are changed to ATRAD 1 and 2
15:00 TX Power Sample (-70 dB coupling)
TX3 5.1, 3.6 Vpp
TX4 5.0, 3.6 Vpp
Line Voltage 4060 VAC, 260 KW
16:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4080 VAC, 260 KW
17:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4080 VAC, 260 KW
18:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4080 VAC, 260 KW
19:00 TX Power Sample (-70 dB coupling)
TX3 3.6 Vpp
TX4 3.6 Vpp
Line Voltage 4080 VAC, 260 KW
"	Transmitter	new	normal	2025_07 All ISR (LP/DP Faraday + EWDrifts)	ISR				