Opened 10 hours ago
#2105 new Transmitter
07 15 19:00 Transmitter Report
Reported by: | vquesada | Owned by: | somebody |
---|---|---|---|
Priority: | normal | Milestone: | 2025_07 All ISR (LP/DP Faraday + EWDrifts) |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
08:30 LV ON
08:40 HV ON
09:00 TX Power Sample (-70 dB coupling)
TX1 4.9 Vpp
TX4 5.0 Vpp
Line Voltage 4050 VAC, 270 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.0 Vpp
TX4 5.0 Vpp
Line Voltage 4070 VAC, 270 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.0 Vpp
TX4 5.0 Vpp
Line Voltage 4050 VAC, 270 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.0 Vpp
TX4 5.0 Vpp
Line Voltage 4050 VAC, 270 KW
12:23 HV OFF,ABS Module Failure
12:49 HV ON
13:00 TX Power Sample (-70 dB coupling)
TX1 5.0 Vpp
TX4 5.0 Vpp
Line Voltage 4050 VAC, 270 KW
13:15 HV OFF,ABS Module Failure
13:30 HV ON
14:00 TX Power Sample (-70 dB coupling)
TX1 5.0 Vpp
TX4 5.0 Vpp
Line Voltage 4050 VAC, 270 KW
14:50 HV OFF, RF failure
16:10 HV ON
16:50 TX Power Sample (-70 dB coupling)
TX1 5.0 Vpp
TX4 5.0 Vpp
Line Voltage 4050 VAC, 270 KW
16:50 Sample with splitter
17:00 TX Power Sample (-70 dB coupling)
TX1 3.6 Vpp
TX4 3. Vpp
Line Voltage 4050 VAC, 270 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 3.6 Vpp
TX4 3. Vpp
Line Voltage 4050 VAC, 270 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 3.6 Vpp
TX4 3. Vpp
Line Voltage 4050 VAC, 270 KW