﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
2013	01 31 08:05 Transmitter Report	ctipacti	somebody	"20:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.7 Vpp
TX4 5.6 Vpp
Line Voltage 4020 VAC, 280 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4020 VAC, 300 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4000 VAC, 300 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4000 VAC, 300 KW
00:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4020 VAC, 300 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4020 VAC, 300 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4000 VAC, 300 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4000 VAC, 280 KW
03:05 DRV3 Bias power supply failure
03:30 RF ON
04:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4020 VAC, 280 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4020 VAC, 300 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4000 VAC, 300 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4000 VAC, 300 KW"	Transmitter	new	normal	2025_01 ISCOD_Dynamics	ISR				