192	04 26 19:00 Transmitter report	rtadeo	somebody	"08:10 LV ON
08:40 HV ON
10:30 PA1 tuning setting
10:40 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
13:20 Power line fuse failure (Control)
14:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 320 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4010 VAC, 310 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
Line Voltage 4010 VAC, 310 KW
"	Transmitter	new	normal	2021_04 HAE	ISR				