Opened 8 weeks ago

#1835 new Transmitter

09 14 07:18 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2024_09 HAD
Component: ISR Version:
Keywords: Cc:

Description

13/09/2024

20:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 310 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 310 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 310 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 310 KW

14/09/2024

00:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 310 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 310 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4020 VAC, 310 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4000 VAC, 310 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4050 VAC, 310 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4050 VAC, 310 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4070 VAC, 310 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 5.10 Vpp
TX3 5.30 Vpp
Line Voltage 4020 VAC, 310 KW

Change History (0)

Note: See TracTickets for help on using tickets.