﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1762	09 04 19:10 Transmitter report	ctipacti	somebody	"08:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.50 Vpp
Line Voltage 4070 VAC, 210 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.50 Vpp
Line Voltage 4080 VAC, 210 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.50 Vpp
Line Voltage 4050 VAC, 210 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 210 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 210 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 210 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.40 Vpp
Line Voltage 4020 VAC, 210 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.40 Vpp
Line Voltage 4050 VAC, 210 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.40 Vpp
Line Voltage 4000 VAC, 210 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.30 Vpp
Line Voltage 4020 VAC, 210 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.30 Vpp
Line Voltage 4050 VAC, 210 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.30 Vpp
Line Voltage 4050 VAC, 210 KW"	Transmitter	new	normal	2024_09 ISCOD - Faraday	ISR				