﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1724	05 31 08:00 Transmitter report	ryaya	somebody	"30/05/2024

21:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4080 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4030 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4000 VAC, 290 KW

31/05/2024

00:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4000 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4050 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4020 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4050 VAC, 290 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4050 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4020 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4060 VAC, 290 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 4.60 Vpp
TX4 4.70 Vpp
Line Voltage 4050 VAC, 290 KW
08:00 HV OFF"	Transmitter	new	normal		ISR				