Opened 8 months ago

#1611 new Transmitter

03 19 19:10 Transmitter Report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2024_03 Oblique+AMISR-14
Component: ISR Version:
Keywords: Cc:

Description

07:56 LV ON
08:05 HV ON
08:15 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 260 KW
08:36 PA3 Screen Power Supply failure
09:00 TX Power Sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 260 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 260 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 260 KW

Change History (0)

Note: See TracTickets for help on using tickets.