Opened 4 years ago
#154 new Transmitter
01 23 18:17 Transmitter report
Reported by: | ctipacti | Owned by: | ctipacti |
---|---|---|---|
Priority: | normal | Milestone: | 2021_01 COSMIC |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
05:48 LV ON
06:08 HV ON
06:25 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 350 KW
06:30 PA3 Screen power supply failure
07:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 350 KW
08:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 350 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4020 VAC, 350 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4000 VAC, 350 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4000 VAC, 350 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4020 VAC, 350 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 350 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4050 VAC, 350 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4000 VAC, 350 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.70 Vpp
TX3 5.80 Vpp
Line Voltage 4000 VAC, 350 KW
18:00 HV OFF
18:15 LV OFF