﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1515	11 07 19:20 Transmitter report	ctipacti	somebody	"08:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 240 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.8 Vpp
Line Voltage 4000 VAC, 240 KW
09:55 PA3 Screen power supply failure
10:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 240 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.8 Vpp
Line Voltage 4000 VAC, 240 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 240 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.8 Vpp
Line Voltage 4050 VAC, 240 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 240 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 240 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.9 Vpp
Line Voltage 4020 VAC, 240 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 240 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.9 Vpp
Line Voltage 4050 VAC, 240 KW"	Transmitter	new	normal	2023_11_DPFaraday + AMISR-14	ISR				