Opened 15 months ago

#1454 new Transmitter

09 25 07:15 Transmitter Report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2023_09 ISCOD ISR+Imaging
Component: ISR+Imaging Version:
Keywords: Cc:

Description

09/24/2023

20:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 280 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4020 VAC, 280 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4020 VAC, 280 KW
22:06 Screen PA3 Failure
23:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4020 VAC, 280 KW

09/25/2023

00:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 280 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 280 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4020 VAC, 280 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4020 VAC, 280 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4020 VAC, 280 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 280 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.6 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 280 KW
06:12 Driver 2 OFF
07:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 5.4 Vpp
Line Voltage 4020 VAC, 280 KW

Change History (0)

Note: See TracTickets for help on using tickets.