Opened 15 months ago

#1425 new Transmitter

09 22 07:00 Transmitter Report

Reported by: vquesada Owned by: somebody
Priority: normal Milestone: 2023_09 ISCOD ISR+Imaging
Component: ISR Version:
Keywords: Cc:

Description

09/21/2023

20:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4060 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW

09/22/2023

00:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW

03:12 Relay

K11 control screen power suppy PA4 FAILURE

04:05 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
06:15 Driver 2 OFF
07:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Line Voltage 4050 VAC, 290 KW

Change History (0)

Note: See TracTickets for help on using tickets.