Opened 16 months ago

#1360 new Transmitter

09 06 19:50 Transmitter report

Reported by: ryaya Owned by: somebody
Priority: normal Milestone: 2023_08 ISR+Imaging+AMISR14
Component: ISR+Imaging Version:
Keywords: Cc:

Description

08:20 SCREEN PA 3 failure
09:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.6 Vpp
TX4 5.9 Vpp
Line Voltage 4010 VAC, 300 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.9 Vpp
Line Voltage 4050 VAC, 300 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.6 Vpp
TX4 5.9 Vpp
Line Voltage 4000 VAC, 300 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.6 Vpp
TX4 5.9 Vpp
Line Voltage 4020 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.9 Vpp
Line Voltage 4060 VAC, 300 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.9 Vpp
Line Voltage 4050 VAC, 300 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.9 Vpp
Line Voltage 4030 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.6 Vpp
TX4 5.8 Vpp
Line Voltage 4000 VAC, 300 KW
17:30 IMAGING ON
18:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.8 Vpp
D2 1.3 Vpp
Line Voltage 4010 VAC, 300 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.9 Vpp
D2 1.3 Vpp
Line Voltage 4020 VAC, 300 KW

Change History (0)