Opened 14 months ago
#1352 new Transmitter
09 06 07:35 Transmitter report
Reported by: | rtadeo | Owned by: | somebody |
---|---|---|---|
Priority: | normal | Milestone: | 2023_08 ISR+Imaging+AMISR14 |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
20:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.9 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
00:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Dr2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
07:22 Imaging OFF