Opened 16 months ago

#1347 new Transmitter

09 05 19:35 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2023_08 ISR+Imaging+AMISR14
Component: ISR+Imaging Version:
Keywords: Cc:

Description

09:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.6 Vpp
TX4 5.7 Vpp
Line Voltage 4050 VAC, 300 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4000 VAC, 300 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4000 VAC, 300 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4020 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4000 VAC, 300 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4020 VAC, 300 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4020 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4000 VAC, 300 KW
17:05 HV OFF (Change connection in hybrid #2)
17:10 HV ON
17:36 IMAGING ON
18:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
D2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
D2 1.3 Vpp
Line Voltage 4000 VAC, 300 KW

Change History (0)

Note: See TracTickets for help on using tickets.