﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1332	09 04 19:30 Transmitter report	ryaya	somebody	"07:50 LV ON
08:10 HV ON
09:00 TX Power Sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Line Voltage 4000 VAC, 280 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Line Voltage 3980 VAC, 300 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Line Voltage 4010 VAC, 300 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Line Voltage 4030 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Line Voltage 4020 VAC, 300 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.8 Vpp
Line Voltage 4000 VAC, 300 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4000 VAC, 300 KW
16:58 CROWBAR
17:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
Line Voltage 4000 VAC, 300 KW
17:20 IMAGING ON
18:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp
Line Voltage 4020 VAC, 300 KW
18:40 SCREEN PA 3 Failure
19:00 TX Power Sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.5 Vpp
TX4 5.7 Vpp
D2  1.3 Vpp
Line Voltage 4020 VAC, 300 KW
19:08 CROWBAR"	Transmitter	new	normal	2023_08 ISR+Imaging+AMISR14	ISR+Imaging				