Opened 18 months ago
#1307 new Transmitter
06 24 June 08:00 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | somebody |
---|---|---|---|
Priority: | normal | Milestone: | 2023_06 ISCOD (ISR+Imaging) |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
06/23/2023
20:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
21:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
22:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
23:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
06/24/2023
00:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
01:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
02:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
03:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
04:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
05:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 250 KW
06:00 Driver 2 OFF Imaging
06:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Line Voltage 4080 VAC, 250 KW
07:00 TX Power Sample (-73 dB coupling)
TX1 6.1 Vpp
TX3 6.1 Vpp
Line Voltage 4080 VAC, 250 KW
08:00 HV OFF
08:15 LV OFF