Opened 17 months ago

#1249 new Transmitter

06 20 07:40 Transmitter Report

Reported by: rtadeo Owned by: somebody
Priority: normal Milestone: 2023_06 ISCOD (ISR+Imaging)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

20:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
21:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
22:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
22:45 Crowbar HV
23:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
00:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
01:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
02:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
03:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
04:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
05:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
06:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 290 KW
06:20 Imaging OFF
07:00 TX Power Sample (-73 dB coupling)
TX1 6.0 Vpp
TX3 5.6 Vpp
TX4 5.2 Vpp
Line Voltage 4050 VAC, 290 KW

Change History (0)

Note: See TracTickets for help on using tickets.