Opened 2 years ago
#1217 new Transmitter
06 13 19:30 Transmitter report
| Reported by: | ryaya | Owned by: | somebody |
|---|---|---|---|
| Priority: | normal | Milestone: | 2023_06 Hybrid |
| Component: | ISR | Version: | |
| Keywords: | Cc: |
Description
09:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4080 VAC, 260 KW
10:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4080 VAC, 260 KW
11:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4040 VAC, 260 KW
12:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4080 VAC, 260 KW
14:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4010 VAC, 260 KW
15:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4080 VAC, 260 KW
16:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4050 VAC, 260 KW
17:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4000 VAC, 260 KW
18:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4070 VAC, 260 KW
19:00 TX Power Sample (-73 dB coupling)
TX1 4.0 Vpp
TX3 4.0 Vpp
Line Voltage 4040 VAC, 260 KW